• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da eficiência do processo de coagulação/floculação e do processo combinado de coagulação/floculação/adsorção para tratamento de águas residuárias de galvanoplastia utilizando Moringa oleífera / Study on the efficiency of the process of coagulation/flocculation and the combined process of coagulation/flocculation/adsorption for treatment of electroplating wastewater using Moringa oleifera

Alves, Alvaro Cesar Dias 24 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:07:59Z (GMT). No. of bitstreams: 1 Alvaro Cesar Dias Alves.pdf: 1860253 bytes, checksum: fce25e3199fa4e1f2d24f3500c996153 (MD5) Previous issue date: 2012-02-24 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / This study aimed to evaluate the efficiency of the process of coagulation/ flocculation and coagulation/flocculation/adsorption combined process for treatment of liquid effluent from the electroplanting industry. Were used the moringa seed as a natural coagulant agent and moringa bark and string bean as adsorbents. Were evaluated the parameters COD, color, pH, turbidity and the concentration of metal ions Cr, Zn, Cu and Ni. In the stage of coagulation/ flocculation were used several concentrations of moringa in salt solution of NaCl 1 M and 0.1M. In the stage of the combined adsorbents were used moringa bark and string beans to determine which of the adsorbent had a better removal efficiency of metals. Tests were also conducted with different ranges of mass for the best adsorbent and variation of pH of the studied effluent. Tests of coagulation/flocculation showed good removal efficiency for the parameters COD, Color, Turbidity and the metals Cr, Zn, Cu and Ni using MO seed in salt solution 1M, these values being 90.49%, 78.34%, 95.13%, 25.29%, 84.30%, 51.11% and 24.74% respectively. In the tests of coagulation/flocculation/adsorption the maximum removal efficiencies were 91.41% for COD, 90.77% for color, 95.31% for Turbidity, 58.36% for Cr, 98.36% for Zn, 97,58% for Cu and 99.11% for Ni. The research showed that after the combined process the electroplanting effluent did not present the necessary characteristics for the released in to water bodies due to the high remaining concentration of Cr (1907.4 mg/L), Color (860 PtCo/L) and COD (330 mg/L). The research for the treatment process demonstrated great effectiveness for most parameters analyzed, however, its necessary to study complementary technologies for this type of treatment effluent in order to achieve an effluent within the release standards into the water bodies. / Este trabalho teve como objetivo avaliar a eficiência do processo de coagulação/floculação e do processo combinado de coagulação/floculação/adsorção para tratamento de efluente liquido da indústria galvânica. Foi utilizada a semente de moringa como coagulante natural e a casca e a vagem de moringa como adsorventes. Foram avaliados os parâmetros DQO, Cor, pH, Turbidez e a concentração dos íons metálicos Cr, Zn, Cu e Ni. Na etapa de coagulação/floculação foram utilizadas várias concentrações de moringa em solução salina de NaCl 1M e 0,1M. Na etapa do processo combinado foram utilizados os adsorventes casca e vagem de moringa para determinação do adsorvente com melhor eficiência de remoção dos metais. Também foram realizados ensaios com variação de massa do melhor adsorvente e variação do pH do efluente estudado. Os ensaios de coagulação/floculação mostraram boa eficiência de remoção dos parâmetros DQO, Cor, Turbidez e dos metais Cr, Zn, Cu e Ni utilizando semente de MO em solução salina 1M, sendo esses valores 90,49%, 78,34%, 95,13%, 25,29%, 84,30%, 51,11% e 24,74%, respectivamente. Nos ensaios de coagulação/floculação/adsorção as eficiências máximas de remoção foram 91,41% para DQO, 90,77% para Cor, 95,31% para Turbidez, 58,36% para Cr, 98,36% para Zn, 97,58% para Cu e 99,11% para Ni. Verificou-se que após o processo combinado o efluente galvânico não apresentou as características necessárias para lançamento em corpos hídricos em função da alta concentração remanescente de Cr (1907,4 mg/L), Cor (860 PtCo/L) e DQO (330 mg/L). Verificou-se que os processos de tratamento estudados demonstraram eficiência para a maioria dos parâmetros analisados, entretanto, fazem-se necessários estudar tecnologias complementares para o tratamento deste tipo de efluente com intuito de obter um efluente dentro dos padrões de lançamentos em corpos receptores.
2

Utilização da eletrocoagulação no tratamento de efluente da indústria galvânica / Use of electrocoagulation in the treatment of wastewater from galvanizing industry

Theodoro, Paulo Sérgio 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:14Z (GMT). No. of bitstreams: 1 Paulo Sergio Theodoro.pdf: 1744465 bytes, checksum: 132da5a46d9247da552f8a27ee087fed (MD5) Previous issue date: 2010-02-18 / The aim of this work is devoted to reduction of the environmental impact of galvanic industry effluents. An electro-coagulation (EC) laboratory scale system using iron plates electrodes was studied for the removal of organic and inorganic pollutants as a by-product from the treatment of galvanic process based-platining industry. An EC reactor consisting of a 1,5 L conical container and a set of seven firmly assembled iron electrode plates, which were parallelly arranged to each other and electrically operated in mono-polar mode, was built. A 1.0 cm gap between the anode and cathode plates using a non-conducting horizontal support was chosen in order to operate the EC reactor in a low electrical current range. A long, electrical rotating cilindrical rotor, with 2,7cm blades at the end of it, made in non-conducting material, was used to turn mechanically the effluent around the rotor axis during the EC treatment. In addition, a 225 cm2 active electrode surface area was kept during the whole EC experiments. In order to obtain optimal values of reaction time, electrical current, rotor angular velocity, and initial effluent pH, a central composite rotatable design (CCRD) was applied. A wide range of reaction time (10-60 min), electrical current (0.3-3.0 A), rotor angular velocity (50-300 rpm), and initial efluent pH (3-10) were used, performing a total of 28 runs with 24+2x4 axial points and 4 central points. Physico-chemical parameters such as chemical oxygen demand (COD), color, turbidity, total solids, and metals (Cr, Ni, Zn, and Cu) were used as response variables. The measurements of physico-chemical parameter and metal concentration values in non- and treated waste waters were carried out by applying the Standard Methodology and the Synchrotron Radiation X-Ray Fluorescence (SR-TXRF) technique, respectively. Using the Statistica software, a 95%-significance level (p<0.05) of the predicted models and interaction effects between reactor operating variables on response variables were evaluated using 3-D response surface curves and analysis of variance. With the factorial design was obtained the following optimum conditions of the reactor, 35 minutes for the time of electrolysis, 170 rpm for agitation, 2.2 A for the electric current and 6.5 for pH. Under these conditions the removal of color and turbidity reached 100%, another considerable value was the removal of around 90% of COD and total solids. Moreover, a removal of around 99% of Zn and Cu was obtained, whereas for Cr and Ni obtained a removal of 100%. Finally, the results of technical and economic analysis showed the cost obtained by the treatment, indicating clearly that the method of electro-coagulation is very promising for industrial application. / O presente trabalho tem como objetivo remover os poluentes de um efluente de galvanização, de modo a reduzir o impacto ambiental dos efluentes da indústria galvânica. Para a remoção dos poluentes, orgânicos e inorgânicos, gerado nos processos de galvanização foi aplicada a eletrocoagulação (EC) em escala de laboratório utilizando eletrodos de ferro. Foi construído um reator de EC, constituído por um recipiente cônico com capacidade de 1,5 L e um eletrodo de ferro montado firmemente com seis placas de ferro, que foram dispostas paralelamente com uma distância de 1(um) centímetro, operado em modo mono-polar. O sistema de agitação mecânico foi construído com duas pás de geometria cilíndrica de 2,7 cm e uma haste de 31,5 cm feito com material não condutor acoplado em um motor elétrico. Durante o experimento da EC foi utilizada uma área efetiva de 225 cm2 do eletrodo. A fim de obter valores ideais do tempo de eletrolise, corrente elétrica, agitação e pH inicial do efluente, foi aplicado o planejamento estatístico composto central (DCCR) com fatorial 24+2X4 pontos axiais + 4 ponto centrais, totalizando 28 ensaios experimentais. Os valores aplicados as variáveis independentes foram de 0,3 a 3 A para a corrente, de 10 a 60 min. para o tempo de eletrolise, de 3 a 10 para o pH inicial e agitação como valores entre 50 e 300 rpm. Foram utilizadas como variáveis resposta os parâmetros físico químico tais como, a demanda química de oxigênio (DQO), cor, turbidez, Sólidos totais e concentração dos metais Cr, Ni, Zn e Cu.Todos os parâmetros físico-químicos foram determinados através o Método Padrão para análise de água, enquanto que as concentrações dos metais foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF). Utilizando o software Statistica, com nível de significância de 95% (p <0,05), os modelos preditos e os efeitos de interação entre as variáveis de operação do reator e as variáveis respostas foram avaliados, utilizando as curvas 3-D de superfície de resposta e a análise de variância. Com o planejamento fatorial foi obtido as seguintes condições ótimas de trabalho do reator, 35 minutos para o tempo de eletrolise, 170 rpm para a agitação, 2,2 A para a corrente elétrica e 6,5 para o pH. Nestas condições a remoção da cor e turbidez alcançaram 100%, outro valor considerável foi a remoção em torno de 90% da DQO e sólidos totais. Além disso, uma remoção em torno de 99% de Zn e Cu também foi obtida, enquanto que para o Cr e Ni obteve-se uma remoção de 100%. Finalmente, os resultados da análise técnico-econômica mostraram o baixo custo obtido pelo tratamento, evidenciando claramente que o método da eletrocoagulação é muito promissor para aplicação industrial.

Page generated in 0.126 seconds