• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Performance do processo de coagulação/floculação no tratamento do efluente líquido gerado na galvanoplastia / Performance process coagulation/flocculation in the treatment of effluent generated in electroplating

Vaz, Luiz Gustavo de Lima 17 February 2009 (has links)
Made available in DSpace on 2017-07-10T18:08:14Z (GMT). No. of bitstreams: 1 Luiz G de Lima Vaz.pdf: 2121268 bytes, checksum: 8362ccb905b9c1c473a10787d8b74866 (MD5) Previous issue date: 2009-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The process of electroplating effluents with high levels of heavy metals and large amounts of dissolved and suspended materials, resulting in high values of color and turbidity, respectively. Because of these characteristics, the effluent of electroplating industries require efficient processes to achieve the levels of concentration and physical and chemical parameters recommended by the environmental legislation. In this context we evaluated the efficiency of organic coagulants (seeds of Moringa oleifera Lam, chitosan, Tanfloc SG and Acquapol C1) and inorganic (aluminum sulfate and ferric chloride) in the first stage of wastewater treatment of electroplating through a planning saturated Plackett and Burman (PB12) followed by a central composite rotational design (DCCR). The following variables were studied: concentration (C), velocity of rapid mixing (VMR) and slow (VML) and time of rapid mix (TMR) and slow (TML), with 30 min of sedimentation, and the response variables analyzed for each coagulant: color, turbidity, settleable solids and COD. Among the agents coagulants/flocculants tested after the completion of PB12, the best combination of results for the removal of the studied parameters occurred with chitosan. The operating conditions were optimized by the statistical program: TMR of 100 rpm, TML of 20 rpm, VMR and VML of 6 and 30 min, respectively, concentration of 12.67 ppm and sedimentation time of 30 min. These conditions it is expected to remove 89.44% of color, 96.87% of turbidity and 35.81% of COD. Based on the results obtained chitosan presented a promising coagulant to the wastewater treatment of electroplating. / Os processos de galvanização geram efluentes com elevados teores de metais pesados e grande quantidade de materiais dissolvidos e suspensos, ocasionando altos valores de cor e turbidez, respectivamente. Devido a estas características o efluente das indústrias de galvanoplastia requerem processos eficientes para alcançar os níveis de concentração e parâmetros físico-químicos recomendados pela legislação ambiental. Neste contexto o presente trabalho avaliou a eficiência de coagulantes orgânicos (sementes de Moringa oleifera Lam, quitosana, Tanfloc SG e Acquapol C1) e inorgânicos (sulfato de alumínio e cloreto férrico) na primeira etapa de tratamento de efluente de galvanoplastia, por meio de um planejamento de Plackett e Burman (PB12) seguido de um Delineamento Composto Central Rotacional (DCCR). As seguintes variáveis foram estudadas: concentração (C), velocidade de mistura rápida (VMR) e lenta (VML) e tempo de mistura rápida (TMR) e lenta (TML), com 30 min de sedimentação, sendo as variáveis de resposta analisadas para cada coagulante: cor, turbidez, sólidos sedimentáveis e DQO. Dentre os agentes coagulantes/floculantes testados, após a realização do PB12, a melhor combinação de resultados para a remoção dos parâmetros estudados ocorreu com a quitosana. As condições operacionais otimizadas pelo programa estatístico foram: TMR de 100 rpm, TML de 20 rpm, VMR e VML de 6 e 30 min, respectivamente, concentração de 12,67 ppm e tempo de sedimentação de 30 min. Nestas condições espera-se remover 89,44% de cor, 96,87% de turbidez e 35,81% de DQO. Com base nos resultados obtidos a quitosana se apresentou um coagulante promissor para o tratamento do efluente de galvanoplastia.
2

Utilização da eletrocoagulação no tratamento de efluente da indústria galvânica / Use of electrocoagulation in the treatment of wastewater from galvanizing industry

Theodoro, Paulo Sérgio 18 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:14Z (GMT). No. of bitstreams: 1 Paulo Sergio Theodoro.pdf: 1744465 bytes, checksum: 132da5a46d9247da552f8a27ee087fed (MD5) Previous issue date: 2010-02-18 / The aim of this work is devoted to reduction of the environmental impact of galvanic industry effluents. An electro-coagulation (EC) laboratory scale system using iron plates electrodes was studied for the removal of organic and inorganic pollutants as a by-product from the treatment of galvanic process based-platining industry. An EC reactor consisting of a 1,5 L conical container and a set of seven firmly assembled iron electrode plates, which were parallelly arranged to each other and electrically operated in mono-polar mode, was built. A 1.0 cm gap between the anode and cathode plates using a non-conducting horizontal support was chosen in order to operate the EC reactor in a low electrical current range. A long, electrical rotating cilindrical rotor, with 2,7cm blades at the end of it, made in non-conducting material, was used to turn mechanically the effluent around the rotor axis during the EC treatment. In addition, a 225 cm2 active electrode surface area was kept during the whole EC experiments. In order to obtain optimal values of reaction time, electrical current, rotor angular velocity, and initial effluent pH, a central composite rotatable design (CCRD) was applied. A wide range of reaction time (10-60 min), electrical current (0.3-3.0 A), rotor angular velocity (50-300 rpm), and initial efluent pH (3-10) were used, performing a total of 28 runs with 24+2x4 axial points and 4 central points. Physico-chemical parameters such as chemical oxygen demand (COD), color, turbidity, total solids, and metals (Cr, Ni, Zn, and Cu) were used as response variables. The measurements of physico-chemical parameter and metal concentration values in non- and treated waste waters were carried out by applying the Standard Methodology and the Synchrotron Radiation X-Ray Fluorescence (SR-TXRF) technique, respectively. Using the Statistica software, a 95%-significance level (p<0.05) of the predicted models and interaction effects between reactor operating variables on response variables were evaluated using 3-D response surface curves and analysis of variance. With the factorial design was obtained the following optimum conditions of the reactor, 35 minutes for the time of electrolysis, 170 rpm for agitation, 2.2 A for the electric current and 6.5 for pH. Under these conditions the removal of color and turbidity reached 100%, another considerable value was the removal of around 90% of COD and total solids. Moreover, a removal of around 99% of Zn and Cu was obtained, whereas for Cr and Ni obtained a removal of 100%. Finally, the results of technical and economic analysis showed the cost obtained by the treatment, indicating clearly that the method of electro-coagulation is very promising for industrial application. / O presente trabalho tem como objetivo remover os poluentes de um efluente de galvanização, de modo a reduzir o impacto ambiental dos efluentes da indústria galvânica. Para a remoção dos poluentes, orgânicos e inorgânicos, gerado nos processos de galvanização foi aplicada a eletrocoagulação (EC) em escala de laboratório utilizando eletrodos de ferro. Foi construído um reator de EC, constituído por um recipiente cônico com capacidade de 1,5 L e um eletrodo de ferro montado firmemente com seis placas de ferro, que foram dispostas paralelamente com uma distância de 1(um) centímetro, operado em modo mono-polar. O sistema de agitação mecânico foi construído com duas pás de geometria cilíndrica de 2,7 cm e uma haste de 31,5 cm feito com material não condutor acoplado em um motor elétrico. Durante o experimento da EC foi utilizada uma área efetiva de 225 cm2 do eletrodo. A fim de obter valores ideais do tempo de eletrolise, corrente elétrica, agitação e pH inicial do efluente, foi aplicado o planejamento estatístico composto central (DCCR) com fatorial 24+2X4 pontos axiais + 4 ponto centrais, totalizando 28 ensaios experimentais. Os valores aplicados as variáveis independentes foram de 0,3 a 3 A para a corrente, de 10 a 60 min. para o tempo de eletrolise, de 3 a 10 para o pH inicial e agitação como valores entre 50 e 300 rpm. Foram utilizadas como variáveis resposta os parâmetros físico químico tais como, a demanda química de oxigênio (DQO), cor, turbidez, Sólidos totais e concentração dos metais Cr, Ni, Zn e Cu.Todos os parâmetros físico-químicos foram determinados através o Método Padrão para análise de água, enquanto que as concentrações dos metais foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF). Utilizando o software Statistica, com nível de significância de 95% (p <0,05), os modelos preditos e os efeitos de interação entre as variáveis de operação do reator e as variáveis respostas foram avaliados, utilizando as curvas 3-D de superfície de resposta e a análise de variância. Com o planejamento fatorial foi obtido as seguintes condições ótimas de trabalho do reator, 35 minutos para o tempo de eletrolise, 170 rpm para a agitação, 2,2 A para a corrente elétrica e 6,5 para o pH. Nestas condições a remoção da cor e turbidez alcançaram 100%, outro valor considerável foi a remoção em torno de 90% da DQO e sólidos totais. Além disso, uma remoção em torno de 99% de Zn e Cu também foi obtida, enquanto que para o Cr e Ni obteve-se uma remoção de 100%. Finalmente, os resultados da análise técnico-econômica mostraram o baixo custo obtido pelo tratamento, evidenciando claramente que o método da eletrocoagulação é muito promissor para aplicação industrial.

Page generated in 0.097 seconds