• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Microfiltração tangencial como alternativa de pós-tratamento de efluente de reator anaeróbio de leito expandido alimentado com esgoto sanitário / Crossflow microfiltration as an alternative for advanced treatment of effluent of anaerobic reactor expanded bed feed with sewage

Vidal, Carlos Magno de Sousa 01 March 2001 (has links)
A constante exploração dos recursos hídricos para os mais diferentes usos sem um planejamento adequado, tem levado ao comprometimento desses recursos, verificando-se cada vez mais aumento no número de pesquisas e investimentos, visando o estudo de alternativas que viabilizem o tratamento avançado de águas residuárias e sua reutilização. Entre essas alternativas, estão as técnicas de separação dos materiais contaminantes por membranas. Neste trabalho estudou-se a viabilidade da utilização da microfiltração tangencial como alternativa de pós-tratamento de efluente de Reator Anaeróbio de Leito Expandido alimentado com esgoto sanitário, analisando-se a influência da utilização de cloreto férrico como coagulante, bem como, membranas com diferentes tamanhos de poro (0,2 e 1,0 &#956m), no desempenho da microfiltração tangencial. Os ensaios no sistema de microfiltração tangencial foram realizados em batelada, com amostras de efluente do reator anaeróbio de leito expandido (RALEX). Verificou-se que para os ensaios realizados com a membrana de 0,2 &#956m, o aumento das dosagens de cloreto férrico, contribuiu para diminuição nos valores de luxo de permeado. Esta relação não ocorreu de forma direta com a membrana de 1,0 &#956m. Os processos de coagulação e floculação foram essenciais para ambas membranas no aumento na eficiência de remoção da demanda química total de oxigênio (mg/l), fosfato total (mg P/l) e turbidez, no entanto, em relação aos valores de fluxo do permeado,foi prejudicial, pois nos ensaios em que as amostras de efluente do RALEX não foram previamente coaguladas e floculadas, a permeabilidade das membranas foi bem maios. O sistema de microfiltração tangencial operando com a membrana de 0,2 &#956m apresentou melhor desempenho, com valores de fluxo do permeado, em geral superiores a 100 L/m2.h, eficiência de 100% na remoção de coliformes totais e fecais, e a dosagem de 40 mg/l de cloreto férrico, já foi suficiente para uma eficiência média de remoção de DQOt de 95%; P.PO4-3 (89,5%) e Turbidez (96,4%). Portanto, a microfiltração tangencial pode ser considerada uma alternativa eficaz como unidade de pós-tratamento de efluente de reator anaeróbio de leito expandido, produzindo efluente que atende os padrões de reuso na agricultura, para coliforme totais e fecais. / The constant exploration of water resources for the most different uses, without an appropriate planning, has lead to the exhaustion of this resources. This scenery has showed the need of increasing researches and investments on alternative forms of wastewater treatment. This work studied the viability of using crossflow microfiltration as an alternative form of advanced treatment of effluents of Anaerobic Reactor Expanded Bed feed with sewage, examining the effect of the use of ferric chloride as coagulam, as well as of different pore size membranes (0,2 and 1,0 &#956m) on the performance of crossflow microfiltration. The experiments on crossflow microfiltration system were carried out in batch, using effluent samples of anaerobic reactor expanded bed. The results obtained with the 0,2 &#956m membrane showed that the increase of ferric chloride dosages contributed for the reduction on flux values. The 1,0 &#956m membrane did not presented this relation. The flocculation and coagulation processes were essentials for increasing the removal efficiency of Total Chemical Oxygen Demand, Total Phosphorus and Turbidity for both membranes, however, for the flux values the effect was harmful, because when the samples of the Anaerobic Reactor Expanded Bed were not previously coagulated and flocculated, the membranes penneability were higher. The Crossflow Microfiltration System, operating with the 0,2 &#956m membrane, presented better performance, with flux values generally superior than 100 L/m2.h, efficiency around 100% on the removal of Total and Fecal Coliforms. For this membrane (0,2 &#956m) the dosage of 40 mg/l of FeCl3 (first stage) was enough for an average of removal efficiency of Total Chemical Oxygen Demand (95%); Turbidity (96.4%); and P.PO4-3 (89,5%). Therefore, crossflow mocrofiltration can be considered an effective alternative for advanced treatment of effluents of Anaerobic Reactor Expanded Bed, producing a final effluent with large potentiality to be used in agriculture.
2

Microfiltração tangencial como alternativa de pós-tratamento de efluente de reator anaeróbio de leito expandido alimentado com esgoto sanitário / Crossflow microfiltration as an alternative for advanced treatment of effluent of anaerobic reactor expanded bed feed with sewage

Carlos Magno de Sousa Vidal 01 March 2001 (has links)
A constante exploração dos recursos hídricos para os mais diferentes usos sem um planejamento adequado, tem levado ao comprometimento desses recursos, verificando-se cada vez mais aumento no número de pesquisas e investimentos, visando o estudo de alternativas que viabilizem o tratamento avançado de águas residuárias e sua reutilização. Entre essas alternativas, estão as técnicas de separação dos materiais contaminantes por membranas. Neste trabalho estudou-se a viabilidade da utilização da microfiltração tangencial como alternativa de pós-tratamento de efluente de Reator Anaeróbio de Leito Expandido alimentado com esgoto sanitário, analisando-se a influência da utilização de cloreto férrico como coagulante, bem como, membranas com diferentes tamanhos de poro (0,2 e 1,0 &#956m), no desempenho da microfiltração tangencial. Os ensaios no sistema de microfiltração tangencial foram realizados em batelada, com amostras de efluente do reator anaeróbio de leito expandido (RALEX). Verificou-se que para os ensaios realizados com a membrana de 0,2 &#956m, o aumento das dosagens de cloreto férrico, contribuiu para diminuição nos valores de luxo de permeado. Esta relação não ocorreu de forma direta com a membrana de 1,0 &#956m. Os processos de coagulação e floculação foram essenciais para ambas membranas no aumento na eficiência de remoção da demanda química total de oxigênio (mg/l), fosfato total (mg P/l) e turbidez, no entanto, em relação aos valores de fluxo do permeado,foi prejudicial, pois nos ensaios em que as amostras de efluente do RALEX não foram previamente coaguladas e floculadas, a permeabilidade das membranas foi bem maios. O sistema de microfiltração tangencial operando com a membrana de 0,2 &#956m apresentou melhor desempenho, com valores de fluxo do permeado, em geral superiores a 100 L/m2.h, eficiência de 100% na remoção de coliformes totais e fecais, e a dosagem de 40 mg/l de cloreto férrico, já foi suficiente para uma eficiência média de remoção de DQOt de 95%; P.PO4-3 (89,5%) e Turbidez (96,4%). Portanto, a microfiltração tangencial pode ser considerada uma alternativa eficaz como unidade de pós-tratamento de efluente de reator anaeróbio de leito expandido, produzindo efluente que atende os padrões de reuso na agricultura, para coliforme totais e fecais. / The constant exploration of water resources for the most different uses, without an appropriate planning, has lead to the exhaustion of this resources. This scenery has showed the need of increasing researches and investments on alternative forms of wastewater treatment. This work studied the viability of using crossflow microfiltration as an alternative form of advanced treatment of effluents of Anaerobic Reactor Expanded Bed feed with sewage, examining the effect of the use of ferric chloride as coagulam, as well as of different pore size membranes (0,2 and 1,0 &#956m) on the performance of crossflow microfiltration. The experiments on crossflow microfiltration system were carried out in batch, using effluent samples of anaerobic reactor expanded bed. The results obtained with the 0,2 &#956m membrane showed that the increase of ferric chloride dosages contributed for the reduction on flux values. The 1,0 &#956m membrane did not presented this relation. The flocculation and coagulation processes were essentials for increasing the removal efficiency of Total Chemical Oxygen Demand, Total Phosphorus and Turbidity for both membranes, however, for the flux values the effect was harmful, because when the samples of the Anaerobic Reactor Expanded Bed were not previously coagulated and flocculated, the membranes penneability were higher. The Crossflow Microfiltration System, operating with the 0,2 &#956m membrane, presented better performance, with flux values generally superior than 100 L/m2.h, efficiency around 100% on the removal of Total and Fecal Coliforms. For this membrane (0,2 &#956m) the dosage of 40 mg/l of FeCl3 (first stage) was enough for an average of removal efficiency of Total Chemical Oxygen Demand (95%); Turbidity (96.4%); and P.PO4-3 (89,5%). Therefore, crossflow mocrofiltration can be considered an effective alternative for advanced treatment of effluents of Anaerobic Reactor Expanded Bed, producing a final effluent with large potentiality to be used in agriculture.
3

Performance do processo de coagulação/floculação no tratamento do efluente líquido gerado na galvanoplastia / Performance process coagulation/flocculation in the treatment of effluent generated in electroplating

Vaz, Luiz Gustavo de Lima 17 February 2009 (has links)
Made available in DSpace on 2017-07-10T18:08:14Z (GMT). No. of bitstreams: 1 Luiz G de Lima Vaz.pdf: 2121268 bytes, checksum: 8362ccb905b9c1c473a10787d8b74866 (MD5) Previous issue date: 2009-02-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The process of electroplating effluents with high levels of heavy metals and large amounts of dissolved and suspended materials, resulting in high values of color and turbidity, respectively. Because of these characteristics, the effluent of electroplating industries require efficient processes to achieve the levels of concentration and physical and chemical parameters recommended by the environmental legislation. In this context we evaluated the efficiency of organic coagulants (seeds of Moringa oleifera Lam, chitosan, Tanfloc SG and Acquapol C1) and inorganic (aluminum sulfate and ferric chloride) in the first stage of wastewater treatment of electroplating through a planning saturated Plackett and Burman (PB12) followed by a central composite rotational design (DCCR). The following variables were studied: concentration (C), velocity of rapid mixing (VMR) and slow (VML) and time of rapid mix (TMR) and slow (TML), with 30 min of sedimentation, and the response variables analyzed for each coagulant: color, turbidity, settleable solids and COD. Among the agents coagulants/flocculants tested after the completion of PB12, the best combination of results for the removal of the studied parameters occurred with chitosan. The operating conditions were optimized by the statistical program: TMR of 100 rpm, TML of 20 rpm, VMR and VML of 6 and 30 min, respectively, concentration of 12.67 ppm and sedimentation time of 30 min. These conditions it is expected to remove 89.44% of color, 96.87% of turbidity and 35.81% of COD. Based on the results obtained chitosan presented a promising coagulant to the wastewater treatment of electroplating. / Os processos de galvanização geram efluentes com elevados teores de metais pesados e grande quantidade de materiais dissolvidos e suspensos, ocasionando altos valores de cor e turbidez, respectivamente. Devido a estas características o efluente das indústrias de galvanoplastia requerem processos eficientes para alcançar os níveis de concentração e parâmetros físico-químicos recomendados pela legislação ambiental. Neste contexto o presente trabalho avaliou a eficiência de coagulantes orgânicos (sementes de Moringa oleifera Lam, quitosana, Tanfloc SG e Acquapol C1) e inorgânicos (sulfato de alumínio e cloreto férrico) na primeira etapa de tratamento de efluente de galvanoplastia, por meio de um planejamento de Plackett e Burman (PB12) seguido de um Delineamento Composto Central Rotacional (DCCR). As seguintes variáveis foram estudadas: concentração (C), velocidade de mistura rápida (VMR) e lenta (VML) e tempo de mistura rápida (TMR) e lenta (TML), com 30 min de sedimentação, sendo as variáveis de resposta analisadas para cada coagulante: cor, turbidez, sólidos sedimentáveis e DQO. Dentre os agentes coagulantes/floculantes testados, após a realização do PB12, a melhor combinação de resultados para a remoção dos parâmetros estudados ocorreu com a quitosana. As condições operacionais otimizadas pelo programa estatístico foram: TMR de 100 rpm, TML de 20 rpm, VMR e VML de 6 e 30 min, respectivamente, concentração de 12,67 ppm e tempo de sedimentação de 30 min. Nestas condições espera-se remover 89,44% de cor, 96,87% de turbidez e 35,81% de DQO. Com base nos resultados obtidos a quitosana se apresentou um coagulante promissor para o tratamento do efluente de galvanoplastia.
4

Aplicação da técnica de eletro-floculação no tratamento de efluentes de curtume / Application of electroflocculation technique for the tannery effluent treatment

Fornari, Marilda Menchon Tavares 12 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:07Z (GMT). No. of bitstreams: 1 Marilda M T Fornari.pdf: 813038 bytes, checksum: 1672b5ca9a95a70d2125540cf442fb8a (MD5) Previous issue date: 2008-02-12 / In the present work has been studied the electro-flocculation efficiency on the reduction of organic and inorganic material concentrations such as Chemical Oxygen Demand (COD), turbidity, total solids and metal, mainly chromium, on an untreated tannery effluent using a pair of electrodes. For this purpose, a lab scale Electro-Flocculation (EF) reactor was constructed using an 8-L plastic cylindrical container, containing a valve in its lower part for sludge evacuation and a horizontal support in its upper part for fixing a pair of electrolytic cell in upright position into a 5-L available reactor volume. The electrodes plates, made of iron or aluminum, were connected to terminals of direct current power supply. All the physical-chemistry parameters were measured following the Standard Methods for water analysis, while metal concentrations were determined using the Synchrotron X-Ray Fluorescence technique, available in the Brazilian Synchrotron Light Laboratory. In order to determine optimal operating conditions, the effects of current intensity, electrodes distance, effluent initial pH, and EF time have been experimentally examined, according to a statistic planning and correlation analysis. For each electrode, a total of 11 EF experiments were carried out for maximum and minimum values of EF reactor operating parameters. Applying a 95% confidence level into the correlation analysis between EF parameters, the physical-chemistry parameters and metal concentrations were reduced in all of them when the effluent initial pH was increased, while the EF time and the applied voltage were reduced for small electrodes distances. Moreover, the EF treatment efficiencies tend towards higher values with an increasing on the current intensity. In order to determine the best reactor operating values, other EF experiments were performed varying the effluent initial pH from 6.5 to 9.0 and from 6.0 to 8.5 for iron and aluminum electrodes, respectively, fixing the distance between the electrodes in 4.0 cm, the current intensity in 5.5 A and the EF time in 30 minutes. Nevertheless, these EF experiments have shown that the reduction factor on parameter concentrations due to an increasing of effluent initial pH was not significant compared to prior experiments. Henceforth, the effluent pH value was maintained near to the original one for the next EF treatments, avoiding introducing other substances into the effluent. Keeping effluent pH value in 7.5, other EF experiments were performed changing the EF time from 15 to 120 min., fixing current intensities and electrode distances in 5.5 A and 4.0 cm, respectively. For these reactor conditions, the EF time setting up in 30 min. was enough to get a good efficiency according the reduction factor in the most of parameters examined, without increasing a lot the reactor electrical power, for both kinds of electrodes. The EF reactor purpose and examined has shown a high efficiency on turbidity and chromium concentration reduction factor (98%). Furthermore, this system can be also used to reduce other elementary concentrations such as calcium, potassium and zinc, for both kinds of electrodes (Fe/Al). In comparison with iron electrodes, aluminum one has reported a better reduction factor (80%) on COD values and a good reduction factor (50%) on iron concentration. On the other hand, the EF method for tanneries effluent treatment system was also compared with conventional method using coagulating and flocculating agents, showing a great similarity between them in the reduction factor. In the EF method is not necessary to introduce substances to start the coagulation and flocculation process in effluent treatment. / Este trabalho tem por objetivo o estudo da eficiência da eletro-floculação na redução das concentrações de substâncias orgânicas e inorgânicas expressas através dos parâmetros: Demanda Química de Oxigênio (DQO), turbidez, sólidos totais e metais, principalmente o cromo, em efluente de curtume não tratado, utilizando um par de eletrodos. Para esse propósito foi construído, em escala laboratorial, um reator confeccionado a partir de um recipiente plástico de 8 litros, contendo uma válvula na parte inferior, para a retirada dos sedimentos, e um suporte horizontal na parte superior para a fixação do par de células eletrolíticas, em posição perpendicular dentro do reator com volume útil de 5 litros. As placas de eletrodos, de ferro e alumínio, foram conectadas a uma fonte de alimentação de energia.Todos os parâmetros físico-químicos foram determinados seguindo o Método Padrão para análise de água, enquanto que as concentrações de metal foram determinadas através da técnica de Fluorescência de Raios X por Reflexão Total, (SR-TXRF), disponível no Laboratório Nacional de Luz Síncroton. A fim de determinar as condições ótimas de operação, os efeitos da intensidade da corrente, distância entre eletrodos, pH inicial do efluente e tempo de eletrólise foram avaliados experimentalmente, de acordo com um planejamento estatístico e análise de correlação. Para cada eletrodo, foram realizados 11 experimentos de EF com valores máximos e mínimos para os parâmetros de operação do reator. Empregando um nível de 95% de confiança na correlação de análises dos parâmetros a análise de correlação entre os parâmetros de EF, os modelos mostraram tendência de redução nas concentrações dos parâmetros físico-químicos e de metais, quando o pH inicial do efluente foi elevado, enquanto o tempo de EF e a voltagem aplicada apresentaram tendência de redução nos valores para uma menor distância entre os eletrodos.. Além disso, a eficiência do tratamento de EF tende a valores mais elevados com o aumento na intensidade de corrente. A fim de determinar as melhores condições de operação do reator, outros experimentos EF foram feitos variando o pH inicial de 6.5 a 9.0 e de 6.0 a 8.5 para eletrodos de ferro e alumínio, respectivamente, fixando a distância entre os eletrodos em 4.0 cm, a intensidade da corrente em 5.5 A e o tempo de EF em 30 minutos. Entretanto, esses experimentos mostraram que o fator de redução percentual na concentração dos parâmetros, causada pelo aumento no pH inicial do efluente, não foi significativo comparado aos experimentos anteriores. Nos tratamentos posteriores de EF, o pH do efluente foi mantido próximo ao original, evitando a introdução de outras substâncias no efluente. Mantendo o valor do pH do efluente em 7.5, outros experimentos de EF foram realizados variando o tempo de eletrólise de 15 a 120 min., e fixando a intensidade da corrente e distância entre os eletrodos em 5.5 A e 4.0 cm., respectivamente. Nessas condições, o tempo de EF fixado em 30 min. foi suficiente para alcançar uma boa eficiência, de acordo com o fator de redução, para maioria dos parâmetros analisados, sem aumentar muito a potência elétrica do reator, para os dois tipos de eletrodos. Os experimentos realizados com reator de EF mostraram uma alta eficiência na redução da turbidez e concentração de cromo (98%). Ademais, esse sistema também pode ser utilizado na redução de outras concentrações elementares como cálcio, potássio e zinco, para ambos os tipos de eletrodos (Fe/Al). Em comparação com os eletrodos de ferro, o eletrodo de alumínio apresentou um melhor fator de redução nos valores de DQO (80%) e um bom fator de redução de ferro (50%). Por outro lado, o método de EF para o tratamento de sistema de efluentes de curtumes foi também comparado ao método convencional utilizando agentes coagulantes e floculantes, mostrando uma grande semelhança entre eles no fator de redução. No método EF não é necessário introduzir substâncias para iniciar o processo de coagulação e floculação no tratamento de efluente.

Page generated in 0.0676 seconds