• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo para otimização do projeto de um sistema de reatores para o tratamento fotoquímico de efluentes industriais. / Study for design optimization of a system of reactors for the photochemical treatment of industrial effluents.

Silva, Débora Pereira Coutinho da 09 August 2012 (has links)
O presente trabalho objetivou estudar aspectos relacionados ao projeto de processos de tratamento de águas efluentes industriais baseados em reatores fotoquímicos. Estudou-se uma unidade de tratamento constituída por um reator solar tubular com coletores parabólicos compostos, o qual opera acoplado a um reator com lâmpadas do tipo tanque. O modelo matemático para simulação do processo foi adaptado a partir dos resultados experimentais obtidos em trabalhos anteriores da equipe de pesquisa deste Departamento, principalmente por Ribeiro (2009). O modelo matemático foi validado por meio de simulações para o sistema operando em regime transiente. O modelo matemático foi adaptado à configuração aqui estudada, de modo a poder ser aplicado ao sistema de reatores operando em regime contínuo, isto é, com alimentação e retirada de material constantes ao longo do tempo. Foi realizado, inicialmente, um estudo de sensibilidade desse modelo em relação às variáveis de processo, baseado em simulações para volumes diferentes do reator solar e reator multi-lâmpadas. A otimização do sistema teve o objetivo de selecionar as configurações do sistema que representam mínimo custo, para os diferentes cenários estudados, para uma concentração especificada de contaminante na corrente de saída. O problema de otimização foi baseado no método da função de penalidade, em que a função de restrição é inserida na função objetivo, transformando assim o problema de otimização num problema irrestrito. O procedimento de busca utiliza o Método Simplex modificado de Nelder e Mead. Para os diferentes cenários estudados, foi comprovado que o fator determinante do custo horário de tratamento fotoquímico é o custo do reagente peróxido de hidrogênio, seguido pelo custo de energia elétrica, custo de investimento do reator de lâmpadas, custo de investimento do reator e das bombas e, por último, o custo de investimento do reator solar. A imposição de limites mais rigorosos para a concentração de saída do efluente faz com que o custo de tratamento seja proibitivo. Portanto, nestes casos é mais interessante, do ponto de vista econômico, utilizar primeiro o processo foto-Fenton até o efluente atingir o limite de biodegradabilidade de 300 mgC/L e, em seguida, submeter este efluente ao tratamento biológico (de menor custo). / The aim of the present study was to investigate aspects related to the design of processes for treating industrial wastewater based on photochemical reactors. The system consisted of a solar tubular reactor with compound parabolic collectors, which operates connected to a multi-lamp stirred tank reactor. The mathematical model for simulating the process was adapted from previous results obtained by the research team of this Department, mainly by Ribeiro (2009). The model was validated by comparing simulation and experimental results obtained with a pilot plant operating in transient regime. The mathematical model was adapted to the configuration in this paper, so that it could be applied to the reactor system operating in continuous regime, i.e., with constant flow rate of the input and output streams. A sensitivity analysis of this model was carried out in relation to process variables, based on simulations for different volumes of the solar reactor and multi-lamp reactor. The optimization of the system aimed to select configurations that represent minimum cost for different scenarios studied for a specified output contaminant concentration. The optimization was based on the penalty function method, in which the restriction function was inserted in the objective function, so as to transform the optimization problem into an unconstrained one. The search procedure was based on the modified Simplex method of Nelder and Mead. For the different scenarios studied, it was verified that the determining factor affecting the treatment cost is the cost of hydrogen peroxide, followed by the electricity cost, investment cost of the lamp reactor, investment cost of pumps and of the solar reactor. The treatment cost increases significantly when lower concentration limits are specified for the output stream. Therefore, as a general recommendation, it is more advantageous from the economic point of view to use the photo-Fenton process until the pollutant concentration is decreased to the threshold of biodegradability (adopted as 300mgC/L in the present study) and then submitting it to a biological treatment.
2

Estudo para otimização do projeto de um sistema de reatores para o tratamento fotoquímico de efluentes industriais. / Study for design optimization of a system of reactors for the photochemical treatment of industrial effluents.

Débora Pereira Coutinho da Silva 09 August 2012 (has links)
O presente trabalho objetivou estudar aspectos relacionados ao projeto de processos de tratamento de águas efluentes industriais baseados em reatores fotoquímicos. Estudou-se uma unidade de tratamento constituída por um reator solar tubular com coletores parabólicos compostos, o qual opera acoplado a um reator com lâmpadas do tipo tanque. O modelo matemático para simulação do processo foi adaptado a partir dos resultados experimentais obtidos em trabalhos anteriores da equipe de pesquisa deste Departamento, principalmente por Ribeiro (2009). O modelo matemático foi validado por meio de simulações para o sistema operando em regime transiente. O modelo matemático foi adaptado à configuração aqui estudada, de modo a poder ser aplicado ao sistema de reatores operando em regime contínuo, isto é, com alimentação e retirada de material constantes ao longo do tempo. Foi realizado, inicialmente, um estudo de sensibilidade desse modelo em relação às variáveis de processo, baseado em simulações para volumes diferentes do reator solar e reator multi-lâmpadas. A otimização do sistema teve o objetivo de selecionar as configurações do sistema que representam mínimo custo, para os diferentes cenários estudados, para uma concentração especificada de contaminante na corrente de saída. O problema de otimização foi baseado no método da função de penalidade, em que a função de restrição é inserida na função objetivo, transformando assim o problema de otimização num problema irrestrito. O procedimento de busca utiliza o Método Simplex modificado de Nelder e Mead. Para os diferentes cenários estudados, foi comprovado que o fator determinante do custo horário de tratamento fotoquímico é o custo do reagente peróxido de hidrogênio, seguido pelo custo de energia elétrica, custo de investimento do reator de lâmpadas, custo de investimento do reator e das bombas e, por último, o custo de investimento do reator solar. A imposição de limites mais rigorosos para a concentração de saída do efluente faz com que o custo de tratamento seja proibitivo. Portanto, nestes casos é mais interessante, do ponto de vista econômico, utilizar primeiro o processo foto-Fenton até o efluente atingir o limite de biodegradabilidade de 300 mgC/L e, em seguida, submeter este efluente ao tratamento biológico (de menor custo). / The aim of the present study was to investigate aspects related to the design of processes for treating industrial wastewater based on photochemical reactors. The system consisted of a solar tubular reactor with compound parabolic collectors, which operates connected to a multi-lamp stirred tank reactor. The mathematical model for simulating the process was adapted from previous results obtained by the research team of this Department, mainly by Ribeiro (2009). The model was validated by comparing simulation and experimental results obtained with a pilot plant operating in transient regime. The mathematical model was adapted to the configuration in this paper, so that it could be applied to the reactor system operating in continuous regime, i.e., with constant flow rate of the input and output streams. A sensitivity analysis of this model was carried out in relation to process variables, based on simulations for different volumes of the solar reactor and multi-lamp reactor. The optimization of the system aimed to select configurations that represent minimum cost for different scenarios studied for a specified output contaminant concentration. The optimization was based on the penalty function method, in which the restriction function was inserted in the objective function, so as to transform the optimization problem into an unconstrained one. The search procedure was based on the modified Simplex method of Nelder and Mead. For the different scenarios studied, it was verified that the determining factor affecting the treatment cost is the cost of hydrogen peroxide, followed by the electricity cost, investment cost of the lamp reactor, investment cost of pumps and of the solar reactor. The treatment cost increases significantly when lower concentration limits are specified for the output stream. Therefore, as a general recommendation, it is more advantageous from the economic point of view to use the photo-Fenton process until the pollutant concentration is decreased to the threshold of biodegradability (adopted as 300mgC/L in the present study) and then submitting it to a biological treatment.
3

Estudo da degradação fotoquímica de soluções aquosas de polietilenoglicol, poliacrilamida e polivinilpirrolidona. / Photochemical degradation study of aqueous solutions of polyrthyleneglicol, polyacrylamide and polyvinylpyrrolidone.

Giroto, Jeanne Aparecida 13 July 2007 (has links)
Este trabalho visa estudar a viabilidade do emprego de processos oxidativos avancados na degradacao de solucoes aquosas de polimeros que sao comumente utilizados em aplicacoes industriais e estao presentes em seus efluentes. Para maior entendimento das reacoes envolvidas no processo oxidativo utilizou-se modelagem molecular nos calculos de constantes cineticas. Na parte experimental estudou-se a degradacao de polietilenoglicol (PEG), polivinilpirrolidona (PVP) e poliacrilamida (PAM) pelos processos foto-Fenton e UV/H2O2. Realizaram-se analises de carbono organico dissolvido (COD), cromatografia liquida de alto desempenho (HPLC) e cromatografia de permeacao em gel (GPC). Observou-se separacao de fases para PVP e PAM, o que contribuiu para uma remocao final de COD de ate 85%. Nas analises de HPLC foram detectados como intermediarios da reacao os acidos: oxalico, formico, malonico e acetico. Os resultados de GPC indicaram comportamentos distintos das distribuicoes de pesos moleculares em funcao do tempo de reacao para os processos UV/H2O2 e foto- Fenton. No conjunto, os resultados comprovam a viabilidade dos processos estudados na degradacao destes polimeros, embora a analise de intermediarios para PAM nao tenha sido conclusiva quanto a formacao de acrilamida. A modelagem molecular confirma que a reacao de abstracao de hidrogenio de uma cadeia polimerica pelos radicais alquilperoxila e de fato a etapa mais lenta do processo oxidativo para PEG e PAM. Para PAM os resultados da modelagem mostram que o ataque dos radicais hidroxila acontece preferencialmente no hidrogenio ligado ao carbono terciario e que a abstracao de hidrogenio do grupo lateral amida parece pouco viavel, ou acontece por um mecanismo diferente do modelado. A reacao de formacao da acrilamida de acordo com o mecanismo proposto tambem apresentou uma constante cinetica muito baixa, o que esta de acordo com os resultados experimentais, ja que nao foi detectada acrilamida como produto da degradacao de poliacrilamida pelos processos foto-Fenton e UV/H2O2, com limite de deteccao de 50 ppb. / The aim of this work is to apply advanced oxidative processes to study the degradation of industrial wastewater containing water-soluble polymers. Kinetic constants of reactions involved in the oxidation processes were calculated by molecular modeling. In the experimental part the degradation of polyvinylpirrolidone (PVP), polyacrylamide (PAM) and polyethyleneglycol (PEG) was studied by photo-Fenton and UV/H2O2 processes. Intermediates of the degradation processes were identified by HPLC and the molecular weight distribution was monitored by GPC. In the experiments with PAM and PVP phase separation was observed, and more than 85% of the DOC was removed. The following intermediate acids were identified: acetic, malonic, formic and oxalic. The molecular weight distribution curves measured by GPC indicate that distinct reaction paths exist for each process studied, although the analysis of intermediates formed during the degradation of PAM was not conclusive with respect to acrylamide formation. The kinetic constants for the reactions involving hydrogen abstraction from PEG chain by hydroxyl and alkylperoxy radicals were calculated. The molecular modeling results confirm that hydrogen abstraction from polymeric chain by alkylperoxy radicals is the determinant step in the oxidation process for PEG and PAM. Polyacrylamide possesses three sites for attack by hydroxyl radicals and the favored path is the abstraction of tertiary hydrogen atom, followed by secondary hydrogen. The abstraction of the amide hydrogen was more difficult. The mechanism proposed for acrylamide formation was not the preferential reaction path. This was expected since acrylamide was not detected in the experiments with a limit detection of 50 ppb.
4

Estudo da degradação fotoquímica de soluções aquosas de polietilenoglicol, poliacrilamida e polivinilpirrolidona. / Photochemical degradation study of aqueous solutions of polyrthyleneglicol, polyacrylamide and polyvinylpyrrolidone.

Jeanne Aparecida Giroto 13 July 2007 (has links)
Este trabalho visa estudar a viabilidade do emprego de processos oxidativos avancados na degradacao de solucoes aquosas de polimeros que sao comumente utilizados em aplicacoes industriais e estao presentes em seus efluentes. Para maior entendimento das reacoes envolvidas no processo oxidativo utilizou-se modelagem molecular nos calculos de constantes cineticas. Na parte experimental estudou-se a degradacao de polietilenoglicol (PEG), polivinilpirrolidona (PVP) e poliacrilamida (PAM) pelos processos foto-Fenton e UV/H2O2. Realizaram-se analises de carbono organico dissolvido (COD), cromatografia liquida de alto desempenho (HPLC) e cromatografia de permeacao em gel (GPC). Observou-se separacao de fases para PVP e PAM, o que contribuiu para uma remocao final de COD de ate 85%. Nas analises de HPLC foram detectados como intermediarios da reacao os acidos: oxalico, formico, malonico e acetico. Os resultados de GPC indicaram comportamentos distintos das distribuicoes de pesos moleculares em funcao do tempo de reacao para os processos UV/H2O2 e foto- Fenton. No conjunto, os resultados comprovam a viabilidade dos processos estudados na degradacao destes polimeros, embora a analise de intermediarios para PAM nao tenha sido conclusiva quanto a formacao de acrilamida. A modelagem molecular confirma que a reacao de abstracao de hidrogenio de uma cadeia polimerica pelos radicais alquilperoxila e de fato a etapa mais lenta do processo oxidativo para PEG e PAM. Para PAM os resultados da modelagem mostram que o ataque dos radicais hidroxila acontece preferencialmente no hidrogenio ligado ao carbono terciario e que a abstracao de hidrogenio do grupo lateral amida parece pouco viavel, ou acontece por um mecanismo diferente do modelado. A reacao de formacao da acrilamida de acordo com o mecanismo proposto tambem apresentou uma constante cinetica muito baixa, o que esta de acordo com os resultados experimentais, ja que nao foi detectada acrilamida como produto da degradacao de poliacrilamida pelos processos foto-Fenton e UV/H2O2, com limite de deteccao de 50 ppb. / The aim of this work is to apply advanced oxidative processes to study the degradation of industrial wastewater containing water-soluble polymers. Kinetic constants of reactions involved in the oxidation processes were calculated by molecular modeling. In the experimental part the degradation of polyvinylpirrolidone (PVP), polyacrylamide (PAM) and polyethyleneglycol (PEG) was studied by photo-Fenton and UV/H2O2 processes. Intermediates of the degradation processes were identified by HPLC and the molecular weight distribution was monitored by GPC. In the experiments with PAM and PVP phase separation was observed, and more than 85% of the DOC was removed. The following intermediate acids were identified: acetic, malonic, formic and oxalic. The molecular weight distribution curves measured by GPC indicate that distinct reaction paths exist for each process studied, although the analysis of intermediates formed during the degradation of PAM was not conclusive with respect to acrylamide formation. The kinetic constants for the reactions involving hydrogen abstraction from PEG chain by hydroxyl and alkylperoxy radicals were calculated. The molecular modeling results confirm that hydrogen abstraction from polymeric chain by alkylperoxy radicals is the determinant step in the oxidation process for PEG and PAM. Polyacrylamide possesses three sites for attack by hydroxyl radicals and the favored path is the abstraction of tertiary hydrogen atom, followed by secondary hydrogen. The abstraction of the amide hydrogen was more difficult. The mechanism proposed for acrylamide formation was not the preferential reaction path. This was expected since acrylamide was not detected in the experiments with a limit detection of 50 ppb.

Page generated in 0.1335 seconds