• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tratamento biológico e físico químico para reuso dos efluentes do estágio de branqueamento de polpa celulósica / not available

Nalim, Luciana 17 August 2001 (has links)
Este trabalho apresenta resultados de pesquisa realizada com objetivo de avaliar a qualidade das águas residuárias do branqueamento após aplicação de filtração por nanofiltração precedida de tratamento biológico e físico-químico para depuração inicial. Os tratamentos foram aplicados aos efluentes coletados nos estágios de extração alcalina e ácida da planta de branqueamento, sem diluição posterior. Obteve-se remoção de 83% da DQO, 95% da DBO, 80% do COT, remoção total de sólidos decantáveis, turbidez e fósforo, deixando apenas 63 mg/lPt de cor residual. Com relação aos sólidos totais, que englobam os íons cloreto e sulfato, além de outros componentes, consegui-se remoção de 70%. Não houve remoção significativa de cloretos. Comparando-se a qualidade do efluente final com os parâmetros requeridos para água fresca conclui-se que a qualidade atingida está próxima daquela requerida para preparo de produtos químicos na fabricação tanto de polpa química quanto de polpa mecânica. / This dissertation presents results from a research designed to assess kraft pulp bleaching wastewater after biological and physical-chemical treatment followed by nanofiltration filtration. The treatment was applied to effluents from the alkaline and acid extraction at the bleaching plant and were treated as collected, that is, without dilution. The overall removal efficiencies were 83% for the COD, 95% for the BOD, 80% for the TOC. The treatment system provide total removal of setteable solids, turbidity and phosphorus. The residual color was only 63 mg/lPt. Total solids removal, which encompases chloride and sulfate ions the removal efficiency reached 70%, however the removal of chloride ions was not significant. Comparing the final effluent quality with the fresh water requirements it is possible to conclude that the treatment provided a water quality close to the required for the preparation of chemicals used in chemical and mechanical pulping.
2

Tratamento biológico e físico químico para reuso dos efluentes do estágio de branqueamento de polpa celulósica / not available

Luciana Nalim 17 August 2001 (has links)
Este trabalho apresenta resultados de pesquisa realizada com objetivo de avaliar a qualidade das águas residuárias do branqueamento após aplicação de filtração por nanofiltração precedida de tratamento biológico e físico-químico para depuração inicial. Os tratamentos foram aplicados aos efluentes coletados nos estágios de extração alcalina e ácida da planta de branqueamento, sem diluição posterior. Obteve-se remoção de 83% da DQO, 95% da DBO, 80% do COT, remoção total de sólidos decantáveis, turbidez e fósforo, deixando apenas 63 mg/lPt de cor residual. Com relação aos sólidos totais, que englobam os íons cloreto e sulfato, além de outros componentes, consegui-se remoção de 70%. Não houve remoção significativa de cloretos. Comparando-se a qualidade do efluente final com os parâmetros requeridos para água fresca conclui-se que a qualidade atingida está próxima daquela requerida para preparo de produtos químicos na fabricação tanto de polpa química quanto de polpa mecânica. / This dissertation presents results from a research designed to assess kraft pulp bleaching wastewater after biological and physical-chemical treatment followed by nanofiltration filtration. The treatment was applied to effluents from the alkaline and acid extraction at the bleaching plant and were treated as collected, that is, without dilution. The overall removal efficiencies were 83% for the COD, 95% for the BOD, 80% for the TOC. The treatment system provide total removal of setteable solids, turbidity and phosphorus. The residual color was only 63 mg/lPt. Total solids removal, which encompases chloride and sulfate ions the removal efficiency reached 70%, however the removal of chloride ions was not significant. Comparing the final effluent quality with the fresh water requirements it is possible to conclude that the treatment provided a water quality close to the required for the preparation of chemicals used in chemical and mechanical pulping.
3

Aplicação do processo oxidativo avançado \'H IND.2\'O IND.2\'/UV como pós-tratamento de reator anaeróbio em efluentes de indústrias de celulose kraft branqueada / Application of the advanced oxidative process \'H IND.2\'O IND.2\'/UV as post-treatment of anaerobic reactor in bleached kraft pulp mill effluents

Ruas, Diego Botelho 11 April 2008 (has links)
A proposta desta pesquisa foi avaliar a aplicação do processo oxidativo avançado (POA), peróxido de hidrogênio (\'H IND.2\'O IND.2\') e radiação ultravioleta (UV), como pós-tratamento de um reator anaeróbio utilizado para tratar efluentes de branqueamento de indústrias de celulose kraft. O principal objetivo do pós-tratamento químico foi aumentar a biodegradabilidade e a remoção de compostos recalcitrantes nos efluentes. O tratamento biológico foi realizado por meio de reator anaeróbio horizontal de leito fixo (RAHLF), em escala de bancada, seguido pelo tratamento \'H IND.2\'O IND.2\'/UV dos efluentes. As doses do agente oxidante variaram de 50 a 500 mg \'H IND.2\'O IND.2\'/L e as aplicações de energia pela lâmpada de radiação ultravioleta foram variadas, principalmente, de 3,8 a 15,0 kWh por \'M POT.3\' de efluente tratado. Desta forma, amostras de efluentes foram coletadas de duas indústrias brasileiras de celulose kraft branqueada, originando respectivamente duas fases experimentais. Na primeira fase, o RAHLF apresentou boa estabilidade de operação, obtendo adequadas eficiências de remoção de DQO (61 ± 3%), COT (69 ± 9%), \'DBO IND.5\' (90 ± 5%) e AOX (55 ± 14%). Todavia, não ocorreu boa remoção dos compostos de absorbância na \'UV IND.254\'. Além disso, houve aumento de constituintes da lignina do afluente para o efluente do RAHLF. Por sua vez, o pós-tratamento com \'H IND.2\'O IND.2\'/UV no efluente anaeróbio proporcionou eficiência de remoção variada nos parâmetros DQO (0 a 11%), \'UV IND.254\' (16 a 35%), lignina (0 a 29%) e AOX (23 a 54%). Em relação a melhoria da biodegradabilidade, todas as dosagens de \'H IND.2\'O IND.2\' estudadas promoveram aumento na relação \'DBO IND.5\'/DQO. Para uma relação \'DBO IND.5\'/DQO média inicial igual a 0,09, correspondente ao efluente do RAHLF, o maior aumento obtido foi de 131% aplicando 500 mg \'H IND.2\'O IND.2\'/L e 7,5 kWh/\'M POT.3\'. O tratamento conjugado biológico e químico foi necessário para atingir ao padrão europeu de emissão de AOX (< 0,4 kg AOX por tonelada de polpa de celulose seca produzida). Na segunda fase, o RAHLF apresentou alguns problemas operacionais, tais como entupimento nas conexões e quebras do reator de vidro, pelo possível aumento da carga orgânica volumétrica aplicada presente nos efluentes coletados na segunda indústria de celulose. O pós-tratamento com \'H IND.2\'O IND.2\'/UV mostrou menor desempenho nessa fase experimental, o que pode ser explicado também pelo maior teor de matéria orgânica residual, lignina, alcalinidade e íons cloretos ainda remanescentes nos efluentes tratados biologicamente. Visando complementar os estudos, testes em reatores aeróbios nos efluentes do RAHLF, tratados e não tratados pelos processos \'H IND.2\'O IND.2\'/UV, foram avaliados. Os resultados demonstraram que os melhores resultados (menor tempo de aeração necessário para atingir a mesma concentração dos parâmetros avaliados) foram alcançados pelos reatores que receberam efluentes previamente tratados pelo POA. Uma avaliação simplificada do custo operacional associado com a aplicação do tratamento \'H IND.2\'O IND.2\'/UV, em escala plena, indicou um custo de R$ 1,87 por \'M POT.3\' de efluente tratado. / The purpose of this research was to assess the application of the advanced oxidation processes (AOP), hydrogen peroxide (\'H IND.2\'O IND.2\') and ultraviolet radiation (UV), as post-treatment for an anaerobic reactor used to treat bleaching effluents from kraft pulp mills. The main objective of the chemical post-treatment was to increase the biodegradability and remove recalcitrant compounds from the wastewater. The biological treatment was performed in a fixed bed anaerobic horizontal reactor (FBAHR), in bench scale, followed by \'H IND.2\'O IND.2\'/UV treatment of the effluents. The oxidizer dosage varied from 50 to 500 mg \'H IND.2\'O IND.2\'/L while the energy applied by the UV lamp ranged, mainly, from 3.8 to 15.0 kWh per \'M POT.3\' of treated effluent. This way, wastewater samples were collected from two brazilian bleached kraft pulp mills thus the results were reported as two different experimental phases. In the first phase the FBAHR showed good operational stability and reached the expected removal efficiencies for COD (61 ± 3%), TOC (69 ± 9%), \'BOD IND.5\' (90 ± 5%) and AOX (55 ± 14%). However, the anaerobic treatment did not provide good removal of compounds indicated by \'UV IND.254\' absorbency. Furthermore, there was an increase of lignin from the affluent to effluent of the FBAHR. In its turn the \'H IND.2\'O IND.2\'/UV post-treatment provided a wide range of removal depending upon the dosage: COD (0 to 11%), \'UV IND.254\' (16 to 35%), lignin (0 to 29%) and AOX (23 to 54%). Regarding to the improvement in biodegradability, all dosages of \'H IND.2\'O IND.2\' applied in this work promoted an increase in the \'BOD IND.5\'/COD ratio. For an average initial \'BOD IND.5\'/COD ratio equal to 0.09, which corresponds to the FBAHR effluent, the greatest increase was 131% with 500 mg \'H IND.2\'O IND.2\'/L and 7.5 kWh/\'M POT.3\'. It was necessary to couple the anaerobic and the oxidative treatment to reach the current European allowable AOX emission load (< 0.4 kg AOX per ton of produced dried cellulose pulp). During the second phase of the experiments, the FBAHR had operational problems as plugging of the tubes and cracking of the reactor wall that may be partially attributed to the higher organic load applied, as the effluents from the second mill were stronger. The AOP post-treatment also had lower performance during this experimental phase, which may be explained by the higher concentration of the organic matter, lignin, alkalinity and chloride ions, still present in the biologically treated effluents. To complete the experiments samples from effluents of the FBAHR and AOP process were submitted to aerobic assays. By tests done in aerobic reactors in the FBAHR effluents, treated and non-treated by the processes \'H IND.2\'O IND.2\'/UV, it was verified that the best results, shorter aeration time requirement to reach the same concentration of the evaluated parameters, were obtained from reactors that received previously treated by AOP effluents. A simplified evaluation of the operational cost associated with the use of the tested AOP, in full scale, indicated a cost of R$ 1.87 per \'M POT.3\' of treated effluent.
4

Aplicação do processo oxidativo avançado \'H IND.2\'O IND.2\'/UV como pós-tratamento de reator anaeróbio em efluentes de indústrias de celulose kraft branqueada / Application of the advanced oxidative process \'H IND.2\'O IND.2\'/UV as post-treatment of anaerobic reactor in bleached kraft pulp mill effluents

Diego Botelho Ruas 11 April 2008 (has links)
A proposta desta pesquisa foi avaliar a aplicação do processo oxidativo avançado (POA), peróxido de hidrogênio (\'H IND.2\'O IND.2\') e radiação ultravioleta (UV), como pós-tratamento de um reator anaeróbio utilizado para tratar efluentes de branqueamento de indústrias de celulose kraft. O principal objetivo do pós-tratamento químico foi aumentar a biodegradabilidade e a remoção de compostos recalcitrantes nos efluentes. O tratamento biológico foi realizado por meio de reator anaeróbio horizontal de leito fixo (RAHLF), em escala de bancada, seguido pelo tratamento \'H IND.2\'O IND.2\'/UV dos efluentes. As doses do agente oxidante variaram de 50 a 500 mg \'H IND.2\'O IND.2\'/L e as aplicações de energia pela lâmpada de radiação ultravioleta foram variadas, principalmente, de 3,8 a 15,0 kWh por \'M POT.3\' de efluente tratado. Desta forma, amostras de efluentes foram coletadas de duas indústrias brasileiras de celulose kraft branqueada, originando respectivamente duas fases experimentais. Na primeira fase, o RAHLF apresentou boa estabilidade de operação, obtendo adequadas eficiências de remoção de DQO (61 ± 3%), COT (69 ± 9%), \'DBO IND.5\' (90 ± 5%) e AOX (55 ± 14%). Todavia, não ocorreu boa remoção dos compostos de absorbância na \'UV IND.254\'. Além disso, houve aumento de constituintes da lignina do afluente para o efluente do RAHLF. Por sua vez, o pós-tratamento com \'H IND.2\'O IND.2\'/UV no efluente anaeróbio proporcionou eficiência de remoção variada nos parâmetros DQO (0 a 11%), \'UV IND.254\' (16 a 35%), lignina (0 a 29%) e AOX (23 a 54%). Em relação a melhoria da biodegradabilidade, todas as dosagens de \'H IND.2\'O IND.2\' estudadas promoveram aumento na relação \'DBO IND.5\'/DQO. Para uma relação \'DBO IND.5\'/DQO média inicial igual a 0,09, correspondente ao efluente do RAHLF, o maior aumento obtido foi de 131% aplicando 500 mg \'H IND.2\'O IND.2\'/L e 7,5 kWh/\'M POT.3\'. O tratamento conjugado biológico e químico foi necessário para atingir ao padrão europeu de emissão de AOX (< 0,4 kg AOX por tonelada de polpa de celulose seca produzida). Na segunda fase, o RAHLF apresentou alguns problemas operacionais, tais como entupimento nas conexões e quebras do reator de vidro, pelo possível aumento da carga orgânica volumétrica aplicada presente nos efluentes coletados na segunda indústria de celulose. O pós-tratamento com \'H IND.2\'O IND.2\'/UV mostrou menor desempenho nessa fase experimental, o que pode ser explicado também pelo maior teor de matéria orgânica residual, lignina, alcalinidade e íons cloretos ainda remanescentes nos efluentes tratados biologicamente. Visando complementar os estudos, testes em reatores aeróbios nos efluentes do RAHLF, tratados e não tratados pelos processos \'H IND.2\'O IND.2\'/UV, foram avaliados. Os resultados demonstraram que os melhores resultados (menor tempo de aeração necessário para atingir a mesma concentração dos parâmetros avaliados) foram alcançados pelos reatores que receberam efluentes previamente tratados pelo POA. Uma avaliação simplificada do custo operacional associado com a aplicação do tratamento \'H IND.2\'O IND.2\'/UV, em escala plena, indicou um custo de R$ 1,87 por \'M POT.3\' de efluente tratado. / The purpose of this research was to assess the application of the advanced oxidation processes (AOP), hydrogen peroxide (\'H IND.2\'O IND.2\') and ultraviolet radiation (UV), as post-treatment for an anaerobic reactor used to treat bleaching effluents from kraft pulp mills. The main objective of the chemical post-treatment was to increase the biodegradability and remove recalcitrant compounds from the wastewater. The biological treatment was performed in a fixed bed anaerobic horizontal reactor (FBAHR), in bench scale, followed by \'H IND.2\'O IND.2\'/UV treatment of the effluents. The oxidizer dosage varied from 50 to 500 mg \'H IND.2\'O IND.2\'/L while the energy applied by the UV lamp ranged, mainly, from 3.8 to 15.0 kWh per \'M POT.3\' of treated effluent. This way, wastewater samples were collected from two brazilian bleached kraft pulp mills thus the results were reported as two different experimental phases. In the first phase the FBAHR showed good operational stability and reached the expected removal efficiencies for COD (61 ± 3%), TOC (69 ± 9%), \'BOD IND.5\' (90 ± 5%) and AOX (55 ± 14%). However, the anaerobic treatment did not provide good removal of compounds indicated by \'UV IND.254\' absorbency. Furthermore, there was an increase of lignin from the affluent to effluent of the FBAHR. In its turn the \'H IND.2\'O IND.2\'/UV post-treatment provided a wide range of removal depending upon the dosage: COD (0 to 11%), \'UV IND.254\' (16 to 35%), lignin (0 to 29%) and AOX (23 to 54%). Regarding to the improvement in biodegradability, all dosages of \'H IND.2\'O IND.2\' applied in this work promoted an increase in the \'BOD IND.5\'/COD ratio. For an average initial \'BOD IND.5\'/COD ratio equal to 0.09, which corresponds to the FBAHR effluent, the greatest increase was 131% with 500 mg \'H IND.2\'O IND.2\'/L and 7.5 kWh/\'M POT.3\'. It was necessary to couple the anaerobic and the oxidative treatment to reach the current European allowable AOX emission load (< 0.4 kg AOX per ton of produced dried cellulose pulp). During the second phase of the experiments, the FBAHR had operational problems as plugging of the tubes and cracking of the reactor wall that may be partially attributed to the higher organic load applied, as the effluents from the second mill were stronger. The AOP post-treatment also had lower performance during this experimental phase, which may be explained by the higher concentration of the organic matter, lignin, alkalinity and chloride ions, still present in the biologically treated effluents. To complete the experiments samples from effluents of the FBAHR and AOP process were submitted to aerobic assays. By tests done in aerobic reactors in the FBAHR effluents, treated and non-treated by the processes \'H IND.2\'O IND.2\'/UV, it was verified that the best results, shorter aeration time requirement to reach the same concentration of the evaluated parameters, were obtained from reactors that received previously treated by AOP effluents. A simplified evaluation of the operational cost associated with the use of the tested AOP, in full scale, indicated a cost of R$ 1.87 per \'M POT.3\' of treated effluent.

Page generated in 0.0987 seconds