1

Efeitos da emissão dos efluentes domésticos na proliferação de Aeromonas Spp em águas de superfície e pescado do estuário do Rio Bacanga, São Luís - MA / The issue of the effluents in the proliferation of Aeromonas spp in surface water and fish Bacanga River estuary, São Luís - MA

Martins, André Gustavo Lima de Almeida January 2005 (has links)
MARTINS, André Gustavo Lima de Almeida. Efeitos da emissão dos efluentes domésticos na proliferação de Aeromonas Spp em águas de superfície e pescado do estuário do Rio Bacanga, São Luís - MA. 2005. 95 f. Dissertação (Mestrado em Ciências Marinhas Tropicais) - Instituto de Ciências do Mar, Universidade Federal do Ceará, Fortaleza, 2005. / Submitted by Debora Oliveira (deby_borboletinha@hotmail.com) on 2011-11-24T14:24:55Z No. of bitstreams: 1 2005_dis_agldamartins.pdf: 920756 bytes, checksum: 66a53ba547f972bf992676592529cff5 (MD5) / Approved for entry into archive by Nadsa Cid(nadsa@ufc.br) on 2011-12-05T18:37:32Z (GMT) No. of bitstreams: 1 2005_dis_agldamartins.pdf: 920756 bytes, checksum: 66a53ba547f972bf992676592529cff5 (MD5) / Made available in DSpace on 2011-12-05T18:37:32Z (GMT). No. of bitstreams: 1 2005_dis_agldamartins.pdf: 920756 bytes, checksum: 66a53ba547f972bf992676592529cff5 (MD5) Previous issue date: 2005 / This research work was designed to detect the presence of Aeromonas in the Bacanga River estuary, São Luís, Maranhão State, Brazil. The database consisted of 90 samples of the river’s surface water and 30 samples of fish, in the period from March to October, 2004. They were amenable, simultaneously, to counting of bacteria on Agar Gelatin Phosphate Salt (GSP) plus 20μg/mL of ampicilim (UFC/mL or UFC/g) and to the determination of the Most Probable Number (MPN/100mL or MPN/g), through the multiple test-tube technique using the Tripticase Soy Broth (TSB) plus 20μg/mL of ampicilim. The analyzed fish species were: catfish (Pimelodus maculatus), mullet (Mugil cephalus), flatfish (Pleuronectes platessa), golden tetra (Hemigrammus rodwayi) and Atlantic thread-herring (Opisthonema oglinum). The results showed dissemination of Aeromonas in the estuary. The counts for the water and fish samples varied from 40 to 1.3x108 UFC/mL and from 3.2x102 to 5.8x106 UFC/g, respectively, with the highest indices being registered at points next to domestic sewages outlets. The values for the MPN/100mL in water samples varied from 2.3x104 to 1.6x107 and for the MPN/g in fish samples from 230 to 24x103. The occurrence of the greatest indices of Aeromonas in April, at the height of the rainy season, and the lowest in October, at the height of the dry season, suggests there to be a probable seasonality of bacteria density in the studied environment. Out of the 751 isolated strains from water samples, 582 were positive for Aeromonas, being 52.7% A. caviae, 23.8% A. hydrophila, 19.5% A. veronii and 3.7% A. sobria. Out of the ones isolated from the fish (245 strains) 184 were identified as Aeromonas, being 43.4% A. caviae, 28.2% A. hydrophila, 26.6% A. veronii and 1.6% A. sobria. As concerns the physical and chemical parameters measured in surface waters of the Bacanga River’s estuary, temperature, salinity and pH only showed significant correlations. In general, strains of Aeromonas sp. were found to be sensitive to most of the tested antimicrobians, except for ampicillim, to which they showed 100% resistance. / Para a detecção de Aeromonas foram coletadas 90 amostras de água de superfície e 30 de peixes no estuário do rio Bacanga em São Luís/MA, no período de março a outubro de 2004. As amostras foram submetidas, simultaneamente, ao método de plaqueamento direto em Agar Gelatina Fosfato Sal (Agar GSP acrescido de 20μg/mL de ampicilina) para a contagem (UFC/mL ou g) e a determinação do Número Mais Provável (NMP/100mL ou g) pela técnica dos tubos múltiplos, utilizando-se o Caldo Tripticase Soja (Caldo TSB com 20μg/mL de ampicilina). As espécies de peixes analisadas foram: Bagre (Pimelodus maculatus), Tainha (Mugil cephalus), Solha (Pleuronectes platessa), Prata (Hemigrammus rodwayi), Sardinha (Opisthonema oglinum). Os resultados obtidos retratam uma ampla disseminação de Aeromonas no estuário. Para as amostras de água e peixes as contagens variaram de 40 a 1,3x108 UFC/mL e de 3,2x102 a 5,8x106 UFC/g respectivamente, sendo que os maiores índices foram obtidos nos pontos próximos às emissões de esgotos domésticos. Os valores para o NMP/100mL de água oscilaram entre 2,3x104 e 1,6x107 e de 230 a 24000/g para peixe. Os maiores índices de Aeromonas foram constatados no mês de maior intensidade de chuvas, abril, e os menores em outubro, correspondente ao pico de estiagem na região, evidenciando assim uma possível sazonalidade na incidência da bactéria no ambiente estudado. Das 751 cepas isoladas das amostras de água, 582 foram positivas para Aeromonas, sendo que 52,7% eram A. caviae, 23,8% A. hydrophila, 19,5%, A. veronii e 3,7% A. sobria. Para as isoladas do pescado (245 cepas) 184 foram identificadas como Aeromonas sendo 43,4% de A. caviae, 28,2% de A. hydrophila, 26,6% A. veronii e 1,6% de A. sobria. Com relação aos parâmetros físico-químicos medidos nas águas de superfície do estuário do rio Bacanga, apenas a temperatura, a salinidade e o pH, tiveram correlações significativas. De modo geral, as cepas de Aeromonas sp. foram sensíveis a maioria dos antimicrobianos testados, com exceção de ampicilina, ao qual 100% das cepas foram resistentes.
2

Cultivo de microalgas em efluentes domésticos: avanço tecnológico para produção de biocombustíveis

Cabanelas, Iago Teles Dominguez 07 March 2012 (has links) (PDF)
Submitted by Programa de Pós-graduação em Biotecnologia (mebiotec.ufba@gmail.com) on 2017-03-28T13:03:11Z No. of bitstreams: 1 DISSERTAÇÃO FINAL CABANELAS, ITD.pdf: 4803170 bytes, checksum: 7ce3e85d909a7c425ee026d9f925290d (MD5) / Approved for entry into archive by Uillis de Assis Santos (uillis.assis@ufba.br) on 2017-03-28T13:16:55Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO FINAL CABANELAS, ITD.pdf: 4803170 bytes, checksum: 7ce3e85d909a7c425ee026d9f925290d (MD5) / Made available in DSpace on 2017-03-28T13:16:55Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO FINAL CABANELAS, ITD.pdf: 4803170 bytes, checksum: 7ce3e85d909a7c425ee026d9f925290d (MD5) / CNPQ / No atual cenário energético mundial é notória a insustentabilidade do uso continuado de combustíveis fósseis, devido à projetada diminuição do suprimento de petróleo, e à contribuição destes combustíveis para o acúmulo de dióxido de carbono na atmosfera. Como, da demanda bruta por energia, no mínimo 60% é absorvida pelo setor de transportes, torna-se lógico propor a substituição dos combustíveis fósseis pelos biocombustíveis como alternativa para redução de emissões poluidoras. As microalgas são uma possibilidade versátil uma vez que podem dar origem a, além de biodiesel (óleo), etanol (fermentação de amido), bioquerosene (hidrocarbonetos líquidos), bioplásticos (biopolímeros), biohidrogênio, biogás (metano) e outros derivados químicos. O uso de resíduos domésticos vem se destacando como opções economicamente viável e efetivamente eco-compatível para o cultivo de microalgas. A presente proposta teve o objetivo de avaliar o potencial de efluentes domésticos urbanos como fonte alternativa de nutrientes para o cultivo de microalgas. O desenvolvimento do presente trabalho foi dividido em dois artigos científicos elaborados com os dados experimentais. Os artigos mostram (i) o efeito de diferentes águas residuárias sobre a microalga Chlorella vulgaris e (ii) os efeito da adição de diferentes concentrações de glicerina sobre o metabolismo das espécies Chlorella vulgaris e Botryococcus terribilis cultivadas em água residuária. A microalga Chorella vulgaris apresentou crescimento satisfatório em diferentes efluentes domésticos tratados, alcançando produtividades entre 50 e 150 mg L-1 d-1. Em todas as amostras foi observada a remoção de nutrientes. A suplementação de CO2 é uma importante variável para a produção de biomassa e eficiente remoção de nutrientes. Chlorella vulgaris foi capaz de fixar como biomassa entre 56 e 242 mg por litro por dia de CO2. Modificações artificiais da razão N/P não aumentou a produção de biomassa nem a taxa de remoção de nutrientes, para os cultivos com efluente da secagem dos lodos. Para os experimentos com adição de glicerina não foi possível estabelecer correlação linear entre as concentrações de glicerina e a produção de biomassa. Contudo, foi observado aumento significativo de biomassa com 25 e 50 mM de glicerina. Tais resultados indicam a possibilidade de aplicar a glicerina como fonte de carbono orgânico para a produção de biomassa microalgal. Também foi possível observar altos valores de remoção de nutrientes, acima de 70% para DQO, nitrogênio e fósforo. Contudo, as produtividades lipídicas, embora não correlacionadas com a disponibilidade de glicerina foram reduzidas com a disponibilidade deste nutriente. Tais resultados apontam a glicerina como indicada para produção de biomassa de microalgas, porém não visando altas produtividades lipídicas.
3

Ozonização como pós-tratamento de efluente de esgoto doméstico

Camilo Júnior, Osli Barreto 22 February 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Agronomia e Medicina Veterinária, Programa de Pós-Graduação em Agronomia, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-20T19:43:11Z No. of bitstreams: 1 2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-20T20:17:50Z (GMT) No. of bitstreams: 1 2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) / Made available in DSpace on 2018-08-20T20:17:50Z (GMT). No. of bitstreams: 1 2018_OsliBarretoCamiloJúnior.pdf: 1184807 bytes, checksum: b209ead832966f07a75cb8760bfbb64e (MD5) Previous issue date: 2018-08-20 / Dentre as várias opções de tratamento secundário de esgoto, o uso de tanques sépticos seguidos do Sistema de Zona de Raízes (SZR) apresentam características favoráveis, como eficiente remoção de microrganismos, sais e compostos tóxicos. Entretanto, persistem atributos como a cor, turbidez, dentre outros que podem ser reduzidos com tratamento terciário, como a ozonização. Diante do exposto, o objetivo deste trabalho foi avaliar a aplicação da ozonização em efluente de esgotos doméstico tratado em tanques sépticos em série seguidos de SZR. Foram aplicados os tempos de exposição ao ozônio de 0, 30, 60, 90, 120 e 150 min. na dosagem constante de 12 mg L-1 de O3, bem como dosagens de 0, 4, 10, 17, 25 e 35 mg L-1 de O3 durante tempo de exposição de 30 min. Em todos os ensaios, a vazão de ozônio foi ajustada em 1 L min.-1. Foram realizadas sete campanhas de coleta de efluente de diferente composição, sendo que em cada amostra foi analisado o Potencial Hidrogeônico (pH); Condutividade Elétrica (CE), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Oxigênio Dissolvido (OD) Alcalinidade Total (Atotal), Sódio (Na+), Potássio (K+), Amônia (NH3), Turbidez, Cor, Escheria coli, Coliformes Totais, Sólidos Suspensos, Sólidos Dissolvidos e Sólidos Totais. A ozonização promoveu redução significativa de cor e turbidez do efluente até o tempo de 120 min de exposição na dosagem de 12 mg L-1 de O3 e até a concentração de 17 mg L-1 de O3 por 30 min. A condutividade elétrica reduziu 7,0% no tempo de esposição de 120 min. sendo que, de maneira geral, o tempo de exposição é mais efetivo na alteração da CE do que o aumento na dosagem de ozônio. O pH se elevou 12,30% no tempo de 120 e 150 min. e 9,4% na dosagem de 4 mg L-1 de O3; já a alcalinidade se elevou 22,2% na dosagem de 17 mg L-1 de O3 e oxigênio dissolvido de 351% no tempo de 90 min. e 424% na dosagem de 17 mg L-1 de O3. A ozonização não promoveu alterações nos teores de potássio, sódio, amônia, sólidos suspensos, sólidos dissolvidos e sólidos totais. A Escheria coli, coliformes totais, DQO e DBO não apresentaram correlação consistente entre os diferentes tempos de exposição e dosagens de ozônio. / There are several options to treat sewage and the use of septic tanks and the Root Zone System (RZS) presents valuable characteristics, as the remotion of microorganisms, salts and toxic compounds. However, there are persistent attributes such as color, turbidity, among others that can be removed with tertiary treatment, such as ozonization. In view of the above, the objective of this work was to evaluate the application of ozonation in treated domestic sewage effluent in septic tanks in series. Exposure times of 0, 30, 60, 90, 120 and 150 min were applied in the constant dosage of 12 mg L-1 of O3, as well as dosages of 0, 4, 10, 17, 25 and 35 mg L-1 of O3 during the exposure time of 30 min. In all tests, the ozone flow rate was adjusted to 1 L min -1. Seven campaigns of collection of different effluent composition were carried out. In each sample of effluent were analyzed the Potention Hydrogen (pH), Electrical Conductivity (EC), Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD), Dissolved Oxygen (DO), Total Alkalinity (totalA), Sodium (Na+), Potassium (K+), Ammonia (NH3), Turbidity, Color, Escheria coli, Total Coliforms, Suspended Solids, Dissolved Solids and Total Solids. At the exposure time of 120 min and 17 mg L-1 of O3, there was reduction of turbidity of 40.6% and 58.9%; color reduction of 76.2% and 81.5%; and reduction of the electrical conductivity of 7.0% in the time of 120 min. The pH increased by 12.30% in the time of 120 and 150 min and 9.4% in the dosage of 4 mg L-1 of O3; Alkalinity rose 22.2% at the dose of 17 mg L-1 of O3 and dissolved oxygen of 351% at 90 min of exposure and 424% at the dose of 17 mg L-1 of O3. The ozonization does not promote any changes in the contents of potassium, sodium, ammonia, suspended solids, dissolved solids and total solids. E. coli, Total Coliforms, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD) did not present a consistent relation between the exposure time and the ozon doses.
4

Estudo dos Aportes Continentais de Carbono Orgânico Total Em Águas Estuarinas do Litoral Sul de Pernambuco, Brasil

SANTOS JÚNIOR, Antonio de Castro 17 February 2012 (has links)
Submitted by Eduarda Figueiredo (eduarda.ffigueiredo@ufpe.br) on 2015-03-12T13:28:37Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação_ Antonio Castro.pdf: 709979 bytes, checksum: 4af3582f9c386d95a0eed2e33a82cfa7 (MD5) / Made available in DSpace on 2015-03-12T13:28:37Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação_ Antonio Castro.pdf: 709979 bytes, checksum: 4af3582f9c386d95a0eed2e33a82cfa7 (MD5) Previous issue date: 2012-02-17 / CNPq / O carbono orgânico total possui um papel importante na quantificação da matéria orgânica carbonácea, principalmente em ambientes sujeitos à poluição orgânica, sendo um bom indicador da qualidade ambiental nos meios hídricos. Foi realizado um estudo sobre os aportes continentais de carbono orgânico total (COT) em águas estuarinas do litoral sul de Pernambuco, com diferentes tipos de intervenção antrópica, a fim de diagnosticar os processos de alteração ambiental da qualidade das águas. Realizaram-se seis campanhas para coletas hidrológicas, durante os períodos de estiagem (setembro, novembro/2008 e janeiro/2009) e chuvoso (março, maio e julho/2009), na baixa-mar e preamar, e em seis pontos fixos de coleta: três nos estuários dos rios Ipojuca/Merepe e três no estuário do rio Massangana. No estuário do rio Ipojuca, as concentrações de COT variaram entre 1,39 e 14,00 mg.L-1, com mediana de 5,66 mg.L-1. Segundo os resultados da ANOVA, essas concentrações apresentaram diferenças significativas quando comparadas com os períodos do ano (F=13,39; p<0,001) e marés (F=4,23; p=0,047). Não foram observadas diferenças significativas entre os pontos de coleta (F=0,39; p=0,677). No estuário do rio Massangana, as concentrações oscilaram entre 1,43 e 14,11 mg.L-1, com mediana de 7,90 mg.L-1. Não foram verificadas diferenças significativas quando comparadas com os períodos do ano (F=0,76; p=0,389), pontos de coleta (F=1,02; p=0,372) e marés (F=0,60; p=0,443). Constatou-se que, as áreas de estudo apresentaram em alguns pontos de coleta e períodos do ano, concentrações de COT superiores ao limite máximo permitido pela Resolução CONAMA no 357/2005 para águas salobras de Classe 2 que é de 5,00 mg.L-1. Os estuários ultrapassaram seu suporte de carga, devido à elevada quantidade de efluentes ricos em matéria orgânica, relacionados com as atividades agroindustriais e efluentes domésticos, caracterizando fontes de poluição orgânica nas regiões.
5

Aproveitamento dos efluentes domésticos para geração de energia em condomínios residenciais de baixa renda / Utilization of domestic wastewater paragraph power generation in low-income residential condominiums

Menezes, Mayara Beuttenmuller Castro de 31 March 2016 (has links)
The study aims to assess the energy potential of the sewage treatment plant, residential condominiums low income Programa Minha Casa Minha Vida (PMCMV), by performing the following estimates: biogas production, production of electric and thermal energy, energy needs the common area of the condominium and economic evaluation of the project. This work shows the possibility of using methane That is the aggressive environment in the Energy Recovery, encouraging application of this paragraph Service Sustainable Use of Renewable Natural Resources and Energy Efficiency. Were done calculations to estimate the biogas and methane accounting YOUR Losses During the anaerobic treatment process. The production of biogas Estimated Average was 58.78 m³ / d resulting in a possible Availability of Electricity 86.61 kWh / d Able to supply a lighting of the posts of Internal Streets and condominium recreation area (sports court + gourmet space) through the hum Generator 18 hp no EXISTING iN biogas fueled market having Integrated filter System That allows connection directly to the generator biodigester canvas. It was taking a interest rate of 17.88% pa Investment. Besides the possibility to meet the local population, can earn credits reversing the Electricity Generated in Distribution Network through the Electric Power Compensation System ANEEL. The use of biogas as Electricity Generation And Important For the environment, it avoids it be released methane gas and STILL diversification of energy matrix. / O estudo busca avaliar o potencial energético, da estação de tratamento de esgoto, de condomínios residenciais de baixa renda do programa minha casa minha vida (PMCMV), realizando as seguintes estimativas: produção de biogás, produção de energia elétrica e térmica, necessidades de energia da área comum do condomínio e avaliação econômica do projeto. Este trabalho aponta a possibilidade de utilizar o metano que é agressivo ao meio ambiente na recuperação de energia, incentivando a aplicação deste serviço para uso sustentável dos recursos naturais renováveis e eficiência energética. Foram realizados cálculos para a estimativa do biogás e do metano contabilizando suas perdas durante o processo de tratamento anaeróbico. A produção média de biogás estimado foi de 58,78 m³/d resultando em uma possível disponibilidade de energia elétrica de 86,61 kWh/d capaz de abastecer a iluminação dos postes das ruas internas e a área de lazer do condomínio (quadra poliesportiva + espaço gourmet) através de um gerador de 18 cv existente no mercado abastecido por biogás possuindo Sistema de filtro integrado que permite a conexão do gerador diretamente na lona do biodigestor. Foi adotando uma taxa de juros de 17,88 % a.a. para investimento. Além da possibilidade de atender a população local, pode-se ganhar créditos revertendo a energia elétrica gerada na rede de distribuição através do sistema de compensação de energia elétrica da ANEEL. A utilização do biogás como geração de energia elétrica é importante para o meio ambiente, pois evita que seja lançado gás metano e ainda diversifica a matriz energética.
6

Uso de esteróides na avaliação de aportes antrópicos e naturais da matéria orgânica no complexo estuarino de Paranaguá

Braun, Juliana Aguilar Fuhrmann January 2006 (has links)
Dissertação(mestrado) - Universidade Federal do Rio Grande, Programa de Pós-Graduação em Oceanografia Física, Química e Geológica, Instituto de Oceanografia, 2006. / Submitted by Cristiane Silva (cristiane_gomides@hotmail.com) on 2013-02-11T23:17:32Z No. of bitstreams: 1 2006_juliana_braun.pdf: 1619378 bytes, checksum: 75d9d7dd8973d75d6d9d22ee9e2b139e (MD5) / Approved for entry into archive by Bruna Vieira(bruninha_vieira@ibest.com.br) on 2013-06-11T22:00:40Z (GMT) No. of bitstreams: 1 2006_juliana_braun.pdf: 1619378 bytes, checksum: 75d9d7dd8973d75d6d9d22ee9e2b139e (MD5) / Made available in DSpace on 2013-06-11T22:00:40Z (GMT). No. of bitstreams: 1 2006_juliana_braun.pdf: 1619378 bytes, checksum: 75d9d7dd8973d75d6d9d22ee9e2b139e (MD5) Previous issue date: 2006 / As regiões costeira do Complexo da Baía de Paranaguá têm sofrido um crescente desenvolvimento industrial, comercial e turístico, que acarreta em aportes de origem industrial, rural e urbana. A determinação da contaminação por esgoto urbano é normalmente realizada por indicadores microbiológicos (ex.: coliformes fecais), mas existem indicadores químicos como os esteróides (ex.: coprostanol) que são menos sensíveis a variações ambientais. Visando avaliar a introdução de matéria orgânica de origem antrópica e biogênica, 9 esteróides fecais foram analisados em 39 sedimentos coletados ao longo do Complexo Estuarino de Paranaguá (PR) entre 2003 e 2005. As concentrações de coprostanol variaram entre 0,02 e 2222 ng.g-1, sendo que o eixo leste-oeste foi a mais contaminado por esteróis de origem antrópica. Os esteróis campesterol, estigmasterol e β-sitosterol, normalmente associados ao aporte de matéria orgânica de origem biogênica, foram identificados em todos os sedimentos analisados. β-sitosterol foi o mais abundante entre os marcadores biogênicos, chegando a representar 58% dos esteróides totais. Isso indica que aportes biogênicas (principalmente terrígenas) são importantes fontes de matéria orgânica para o Complexo Estuarino de Paranaguá, principalmente onde não foi encontrada contaminação antropogênica. / The coastal area of Paranaguá Bay (PR) has been receiving an increasing industrial, commercial and tourist development. As a consequence, its waters have been receiving different sorts of industrial, rural and urban inputs. The determination of the contamination from urban sewage is normally evaluated using microorganisms such as fecal coliforms, but molecular markers such as coprostanol are less sensitive to environmental variability. Thus, the present work aimed to evaluate the introduction of organic matter from anthropogenic and natural sources by analyzing 9 sterols (fecal and biogenic) in 39 sediments sampled from the Paranaguá Bay between 2003 and 2005. The concentrations of coprostanol varied between 0.02 and 2222 ng.g-1, and the east-west axis of the Paranaguá Bay was more contaminated by fecal sterols. The sterols campesterol, estigmasterol and β-sitosterol, normally associated with biogenic inputs, were detected in all sediments analyzed. β-sitosterol was dominant, reaching up to 58% of the total sterols. Thus, biogenic inputs are an important source of organic matter to the Paranaguá Bay, mainly where anthropogenic contamination is less important.
7

Avaliação ambiental da microbacia do córrego Embauval e influência da ETE do condomínio residencial Terra Nova em Várzea Grande-MT

Mattos, Thayana Alves 04 December 2014 (has links)
Submitted by Valquíria Barbieri (kikibarbi@hotmail.com) on 2018-04-06T21:41:13Z No. of bitstreams: 1 DISS_2014_Thayana Alves Mattos.pdf: 4395808 bytes, checksum: 9adef294170640a916aa86281dff3a47 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2018-04-23T18:36:20Z (GMT) No. of bitstreams: 1 DISS_2014_Thayana Alves Mattos.pdf: 4395808 bytes, checksum: 9adef294170640a916aa86281dff3a47 (MD5) / Made available in DSpace on 2018-04-23T18:36:20Z (GMT). No. of bitstreams: 1 DISS_2014_Thayana Alves Mattos.pdf: 4395808 bytes, checksum: 9adef294170640a916aa86281dff3a47 (MD5) Previous issue date: 2014-12-04 / Sérios problemas ambientais são advindos de alguns tipos de uso e ocupação inadequada do solo. Exemplo disso são as estações de tratamento de efluentes que tem a finalidade de reduzir a carga contaminante ou poluente de esgotos, a um nível compatível com o corpo receptor, ou seja, de modo que o efluente final tratado possa ser despejado sem provocar a degradação da água e sem gerar riscos à saúde do homem. Entretanto, em muitos casos, esta função não é atendida. Assim, o objetivo deste trabalho foi realizar o diagnóstico ambiental da Microbacia Hidrográfica do córrego Embauval, afluente do rio Cuiabá, dando ênfase aos possíveis impactos que podem ser ocasionados nela em virtude do lançamento do efluente doméstico do condomínio Residencial Terra Nova no manancial superficial. O estudo é relativo aos meses de maio, agosto, setembro, outubro e dezembro de 2013 e janeiro 2014. Para o desenvolvimento do referido diagnóstico, a Microbacia foi caracterizada através de análises laboratoriais de amostras de água do corpo d’ água além da utilização do Sistema de Informações Geográficas - SIG. Foram coletadas amostras de efluente bruto e tratado da estação de tratamento de esgoto - ETE, amostras do córrego Embauval próximo a sua nascente, montante e a jusante do lançamento do efluente tratado. As variáveis analisadas foram: pH, demanda bioquímica de oxigênio (DBO5), demanda química de oxigênio (DQO), sólidos totais, sólidos totais fixos, sólidos totais voláteis, sólidos sedimentáveis, nitrato, nitrito, nitrogênio amoniacal, nitrogênio total kjeldahl, fósforo total, coliformes totais e coliformes termotolerantes. Os resultados analíticos da água do córrego Embauval mostraram que o Índice de Qualidade da Água – IQA nos três pontos é Ruim, apresentado resultados que não atendem a qualidade especificada para corpos d’ água de água doce de classe 2. Na Microbacia as áreas de preservação permanente foram ocupadas por residências, grande parte das habitações que estão locadas a beira do córrego lançam seus esgotos sem tratamento no meio ambiente, há disposição de resíduos sólidos em terrenos baldios e nos mananciais superficiais. A ETE estudada apresentou problemas operacionais necessitando adequação, mas esta alcançou eficiência no tratamento de DBO5 e DQO de 85%. / Serious environmental problems are arising from some types of use and inappropriate land use. Examples are wastewater treatment plants which aims to reduce the contaminant or pollutant load of wastewater to a level compatible with the receiving body, or so that the final treated effluent can be discharged without causing the degradation of water and without any risk to human health. However in many cases, this function is not answered. The objective of this study was the environmental assessment of Watershed River stream Embauval, tributary of the Rio Cuiabá, emphasizing the potential impacts that may be caused in it by virtue of the release of wastewater from Newfoundland Residential condominium in surface source. The study is for the months of May, August, September, October and December 2013 and January 2014. For the development of this diagnosis, Watershed was characterized by laboratory analysis of water samples from the body of water than the use of Geographic Information System - GIS. Raw wastewater samples were collected and treated in the sewage treatment plant - ETE, Embauval stream samples near its source, upstream and downstream of the release of treated effluent. The variables analyzed were: pH, biochemical oxygen demand (BOD5), chemical oxygen demand (COD), total solids, fixed total solids, total volatile solids, sediments, nitrate, nitrite, ammonia, nitrogen full kjeldahl, total phosphorus , total coliforms and fecal coliforms. The analytical results of Embauval stream water showed that the Water Quality Index - IQA the three points Bad, presented results that do not meet the specified quality for bodies of freshwater water class 2. Watershed in the permanent preservation areas were occupied by residences, most of the units that are leased to stream edge release their untreated sewage into the environment, there is disposal of solid waste in vacant lots and surface waters. TEE studied had operational problems requiring adequacy, but this achieved efficiency in the treatment of BOD5 and COD of 85%.
8

Bioensaio toxicológico com cianobactérias do efluente da lagoa de estabilização e do Igarapé Grande, Boa Vista, Roraima

Eliana Fernandes Furtado 28 March 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A pesquisa teve o objetivo de averiguar a presença de toxicidade nas cianobactérias planctônicas no deságue da Lagoa de estabilização no igarapé Grande, em Boa Vista, por meio de bioensaio em camundongos de linhagem Swiss albino. O corpo hídrico em estudo está localizado na área urbana de Boa Vista, recebe influência resultante da descarga final dos esgotos domésticos dos moradores próximos e de efluentes do sistema de tratamento de esgotos sanitários da cidade, apresentando florações em alguns trechos. Pesquisas anteriores constataram a presença de florações de cianobactéria planctônica nesse ambiente. No entanto, havia a ausência de estudos sobre a toxicidade das florações de cianobactéria planctônicas existentes no igarapé Grande. A área escolhida foi georeferenciada e denominada como: E1 (montante do deságue da ETE), situada no igarapé grarde; E2 (desague/calha); E3 (jusante do deságue). Foram realizadas três coletas amostrais no período seco e três no período das chuvas. No momento da coleta, foram feitas medidas do pH e temperatura da água. Em seguida, foram realizadas as análises das concentrações de clorofila-a, nitrogênio amoniacal, fósforo total, turbidez e estimativa de densidade celular. Foi observado a presença de cianobactérias da espécie Planktothrix agardhii (Gomont) Anagnostidis et Komárek durante todos os meses de coletas, nos períodos sazonais (seco e chuvoso) e confirmou-se que a Estação de Tratamento de Esgoto Sanitário do município de Boa Vista ETE/BV - é a fonte de entrada dessa espécie de cianobactéria no igarapé Grande. Foi observada a distribuição dos organismos na superfície da água afetando a qualidade físico-química do igarapé Grande. Também o teste estatístico possibilitou a identificação da amônia (NH3) como a variável de maior contribuição para a toxicidade nas estações. Além disso, o resultado foi ratificado pelos testes quimiométricos PCA; FA. O teste (DL50 -24 horas), realizado por meio de bioensaio em camundongos no período seco, do material algáceo da estação E3, apresentou a toxicidade em doses acima de 2.500 mg kg mL- (p.c), com a maior mortalidade de 75% dos indivíduos do grupo que recebeu as concentrações de 100 mg mL-. Os resultados da estação de coleta E2, mostram mortalidade de 25% dos indivíduos na concentração de extrato de 50 mg mL-, 25% de indivíduos e 100 mg mL- dos individuo e 75% de indivíduos com a concentração de 150 mg mL- das amostras coletadas durante o período das chuvas. / The study aimed to access the presence of toxic planktonic cyanobacteria by mouse bioassay in the outflow of the stabilization pond and in the Igarapé Grande, Boa Vista, RR. The waterbodies under study are located in the urban area of Boa Vista, and are influenced by the final discharge of the domestic sewage from nearby residents and effluents of the sewage treatment plant from the city. Previous research has established the presence of cyanobacterial blooms in this environment. However, there was a lack of studies on the toxicity of the cyanobacteria that bloom in the stabilization pond system and adjacent Igarapé Grande. The study area was geo-referenced and named as E1 (upstream of the sewage treatment plant outflow), located in the Igarapé Grande, E2 (outflow/gutter), and E3 (downstream of the outflow), also in the Igarapé Grande. It was performed three sample collections during the dry season and three during the rainy season. At the time of the samplings measurements of pH and water temperature were carried out. It was also collected samples for the estimation of chlorophyll-a, ammonia nitrogen, total phosphorus, turbidity and cell density evaluation. We observed the presence of the cyanobacteria of the genus Planktothrix agardhii during all the sampled months in both seasons (dry and rainy), confirming the city sewage treatment plant as the main source of entry of this species in the Igarapé Grande. It was also confirmed that the distribution of the organisms on the water surface affects the physico-chemical quality of the Igarapé Grande. Statistical analysis enabled the identification of ammonia as the parameter of greatest contribution to the toxicity in the sampled locations. In addition, confirmation was obtained by the chemometric tests PCA, FA, HCA and PLS. The mouse bioassay tests (LD50 - 24h) showed toxicity at doses above 2,500 mg.Kg-1 b.w. and at concentrations of cell extract over 50 mg mL-. The higher mortality occurred in 75% of individuals in the group that received concentrations of 100 mg mL- of the material collected at E3 during the dry season. The results of E2 sampling station showed mortality of 25% of individuals at extract concentration of 50 mg mL-; 25% of individuals at 100 mg mL- and 75% of individuals at concentration of 150 mg mL- from the samples collected during the rainy season.
9

O balanço de massa das unidades componentes de uma estação de tratamento de esgoto e a utilização da estatística multivariada como ferramenta de verificação do comportamento físico, químico, bacteriólogico e de metais no esgoto bruto e tratado. Estudo de caso: estação de tratamento de esgoto doméstico – ETE Sideral - Belém - PA

FARIAS, Flavia da Silva 04 October 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:36:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_BalancoMassaUnidades.pdf: 3176538 bytes, checksum: 17d2dc7e6c829993e2dc72066b1fb750 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T12:00:24Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_BalancoMassaUnidades.pdf: 3176538 bytes, checksum: 17d2dc7e6c829993e2dc72066b1fb750 (MD5) / Made available in DSpace on 2017-03-20T12:00:24Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_BalancoMassaUnidades.pdf: 3176538 bytes, checksum: 17d2dc7e6c829993e2dc72066b1fb750 (MD5) Previous issue date: 2013-10-04 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / O estudo sobre o Balanço de massa das unidades componentes de uma estação de tratamento de esgoto e a utilização da estatística multivariada como ferramenta de verificação do comportamento do esgoto bruto e tratado foi realizado na ETE Sideral no Munícipio de Belém Pará Brasil. Neste estudo foiobservado todo o fluxograma constituinte da estação que foi projetada para receber uma vazão máxima de esgoto bruto de 73 l/s., como em verificação local se constatou que a vazão para qual a estação foi projetada é consideravelmente menor o balanço de massa e todo o resto do estudo foi trabalhado em cima da vazão de projeto. Na verificação das partes físicas constituintes da estação verificaram-se não conformidades nas medidas que foram sugeridas no projeto executivo.Na caracterização dos metais presentes no esgoto bruto e tratado verificou-se que na Analisedas Componentes Principais o Boro (B) com (63,5%) e seguido do Bário (Ba) com (21,9%) justificam 84,48% o coeficiente de variação que os determinam como os metais predominantes no Afluente. No Efluente o Boro (B) apresentou um coeficiente de variação de 73,7% o que o justifica como sendo o principal componente no afluente da ETE. Na caracterização dos metais no lodo observou-se que com uma porcentagem de 98,8% o Bário (Ba) é o principal elemento encontrado. Os resultados obtidos com a análise de componentes principais para a caracterização físico-químicas e bacteriológicas do esgoto bruto e tratado da ETE observou-se que a variável ―DQO total‖ encontra-se positivamente relacionada com a componente DBO e negativamente correlacionado com a Alcalinidade Total. Em relação às características físico-químicas e bacteriológicas, elevados teores de DBO, Coliformes termotolerantes, SST e SSV, oriundos dos lançamentos dos efluentes domésticos, fazendo com que apresentassem as maiores concentrações de carga orgânica remanescente. / The mass balance of the component units of a wastewater sewage treatment and use of multivariate statistics as a tool for verifying the behavior of raw sewage and treated, was implemented in ETE Sidereal Municipality of Belem do Para in Brazil. This study observed the entire flowchart constituent of the station that is designed to receive a maximum flow of raw sewage of 73 l / s. and now serves a flow of only 1.7 l / so that decreases in 96% of the station was designed, realizing then that today the Sidereal ETE is oversized. In verifying the constituent physical parts of the station there were not in compliance measures that have been suggested in the executive project and were perceived as "in situ". In the mass held for three types of flows: maximum (73 l / s) averaged 43 l / if current 1.7 l / s realized that the decrease in attendance constituent units of the system decreases somewhere around 97.5% the volume to which the components are designed for and found in the Sewage Treatment Station Sidereal. In the characterization of the metals present in the raw sewage treated and it was found that the Principal Component Analysis of the boron (B) (63.5%) and followed by barium (Ba) with (21.9%) justify 84.48% the coefficient of variation that determine how prevalent metal in the influent. In Effluent Boron (B) showed a coefficient of variation of 73.7% which justifies as the main component in the influent of WWTP. In the characterization of metals in the sludge was observed that with a percentage of 98.8% the Barium (Ba) is the main element found. The results obtained with principal component analysis to characterize the physic-chemical and bacteriological analyzes of raw sewage and treated ETE observed that the variable "total COD" is positively related to component BOD and negatively correlated with the Total Alkalinity . Regarding physic-chemical and bacteriological, high levels of BOD, Fecal coliform, TSS and VSS, from the releases of effluents, making present the highest concentrations of organic load remaining.
10

Uso de modflow para simulação da hidrodinâmica de meios porosos em wetlands construídos / Modflow for hydrodynamic simulation of the porous media in constructed wetlands

Fioreze, Mariele 27 January 2017 (has links)
Constructed wetlands (CWs) are artificial systems used for wastewater treatment, whose objective is to reproduce, under controlled conditions, the treatment mechanisms that occur in natural environments, through the exploration and improve the processes that involve the vegetation, porous media and microbial assemblages. Horizontal subsurface flow constructed wetlands (HSSF-CWs) is characterized by flow in a horizontal direction, in a gravel or sand beds planted or unplanted with emergent macrophytes whose the inlet and outlet are horizontally opposed, which allows the wastewater flow through the rhizosphere and have contact with the biofilm formed in subsurface. Traditional studies about CWs focuses on the efficiency of contaminants removal look at systems as a "black-boxes" from empirical approaches and do not distinguish between the different active removals processes. The development of numerical models, in order to helping to identify and improve the role of each element acting in the treatment, whether the properties of the porous media, constructive geometry, flow characteristics, among others, appears as an alternative to reach a more detailed understanding of the internal processes involved in CWs. In general, numerical models consist of governing equations (derived from the mathematical combination of the water balance and Darcy's law), initial conditions (they refer to the distribution of the hydraulic head in the model domain) and boundaries conditions (define the hydraulic or physical boundaries that delimit the model domain). In the last decade, different 1D and 2D numerical models have been developed and applied for the simulation of subsurface flow CWs under conditions of saturated horizontal flow (CWM1-RETRASO and PHWAT), variably saturated vertical flow (FITOVERT and HYDRUS-CW2D) and vertical or horizontally saturated flow (HYDRUS-CWM1). However, few studies regarding the application of 3D numerical models for CWs simulation are reported in the scientific literature. In this study, the hydrodynamic simulation of the porous media in a horizontal subsurface flow constructed wetland was run through the application of a 3D numerical model. The flow patterns were simulated according to the project design and scenarios with changes in the porous media hydrodynamic (hydraulic conductivity) and in the positioning of the wastewater distribution mechanisms (distribution along the cross section with two pipes) in order to verify the influence of these factors in the flow pattern and also to indicate advantages and disadvantages that contribute to the design. The softwares MODFLOW and MODPATH, in the GMS family code, were used for to simulate the direction and flow velocity, hydraulic head and pathlines. The model proved to be a powerful tool to simulation, allowing observing the interdependence between the hydrodynamic parameters and the hydraulic characteristics in the porous media. The simulated scenarios showed the possibility of improving the flow patterns, mainly using two pipes to distribute the wastewater in a more homogeneous way along the cross section of the bed. The use of a porous media with lower hydraulic conductivity also showed improvement in flow characteristics evaluated. However, the general context of wastewater treatment facilities (pretreatment units and tributary loads) should be considered, since materials with low hydraulic conductivity are more susceptible to clogging. Proper design is crucial to improving the treatment conditions in the HSSF-CWs and also to avoid the occurrence of hydraulic problems and damage to the treatment, such as the clogging. / Wetlands construídos (WCs) são tecnologias empregadas para o tratamento de águas residuárias, cujo objetivo é reproduzir, sob condições controladas, os mecanismos de depuração que ocorrem em meios naturais, através da exploração e aperfeiçoamento dos processos que envolvem a vegetação, o substrato e os microrganismos. Wetlands construídos de escoamento subsuperficial de fluxo horizontal (WCFH) são caracterizados pelo fluxo em direção horizontal através de um leito de cascalho ou areia, vegetado ou não com macrófitas emergentes, cujas entrada e saída dos efluentes são horizontalmente opostas, o que permite que as águas residuárias fluam através da rizosfera e tenham contato com o biofilme formado em subsuperfície. Tradicionalmente, os estudos sobre WCs incidem apenas sobre a remoção das concentrações de contaminantes, considerando esses sistemas como “black-boxes” a partir de abordagens empíricas, sem fazer distinção entre os diferentes processos atuantes. O desenvolvimento de modelos numéricos, como forma de auxiliar a identificar e aperfeiçoar o papel de cada elemento atuante no tratamento, quer sejam as propriedades do meio poroso, a geometria construtiva, as características de fluxo, entre outros, surge como alternativa para o alcance de uma compreensão mais detalhada dos processos internos intervenientes nos WCs. De uma forma geral, os modelos numéricos são constituídos por equações governantes (derivada da combinação matemática da equação de balanço de água e da lei de Darcy), por condições iniciais (dizem respeito à distribuição da carga hidráulica no domínio do modelo) e por condições de contorno (definem as fronteiras hidráulicas ou físicas que delimitam o domínio do modelo). Na última década, diferentes modelos 1D e 2D foram desenvolvidos e aplicados para a simulação de WCs de escoamento subsuperficial em condições de fluxo horizontal saturado (CWM1-RETRASO e PHWAT), vertical variavelmente saturado (FITOVERT e HYDRUS-CW2D) e vertical ou horizontal variavelmente saturado (HYDRUS-CWM1). Porém, poucas experiências relativas à aplicação de modelos 3D para simulação de WCs são relatadas pela literatura científica. Neste trabalho, a simulação da hidrodinâmica do meio poroso de um sistema de tratamento de efluentes do tipo wetlands construídos de escoamento subsuperficial de fluxo horizontal foi realizada por meio da aplicação de um modelo numérico 3D. Foram simuladas as condições de fluxo conforme as especificações de um projeto de engenheria, e também cenários com mudanças nas características hidrodinâmicas do meio poroso (condutividade hidráulica) e no posicionamento dos mecanismos de distribuição das águas residuárias (distribuição ao longo da seção transversal por meio de duas tubulações) visando verificar a influência desses fatores no sistema de fluxo e também indicar vantagens e desvantagens que contribuam para a elaboração de projetos. Os softwares MODFLOW e MODPATH, executados por meio da interface GMS, foram utilizados para a simulação da direção e velocidade de fluxo, nível hidráulico e linhas de trajetória das partículas transportadas por advecção. O modelo provou ser uma ferramenta poderosa para a simulação, permitindo visualizar a interdependência entre os parâmetros hidrodinâmicos e as características hidráulicas do meio poroso. Os cenários simulados mostraram a possibilidade de melhoria dos padrões de fluxo, principalmente por meio do uso de duas tubulações para distribuição dos efluentes de forma mais homogênea ao longo da seção transversal do leito. O uso de materiais com menor condutividade hidráulica também apresentou melhoria nas características de fluxo avaliadas. Porém, deve-se considerar o contexto geral das instalações de tratamento das águas residuárias (unidades de tratamento preliminar e cargas afluentes), visto que materiais com baixa condutividade hidráulica são mais susceptíveis ao entupimento. A concepção adequada é crucial para melhorar as condições de tratamento verificadas nos WCFH e também para evitar a ocorrência de danos e problemas hidráulicos, como a estagnação de fluxo em zonas de baixa velocidade de escoamento.