Spelling suggestions: "subject:"alectric circuitbreakers"" "subject:"alectric circuitbreaker""
1 |
Overload protection using solid state devicesMeans, James Andrew, 1937- January 1966 (has links)
No description available.
|
2 |
A solid state AC circuit breaker with a selective trip timeCarter, David William, January 1969 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1969. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
3 |
Ground fault detection for human safety utilizing a differential transformer sensorWilliams, Lynn Edward, January 1968 (has links)
Thesis (M.S.)--University of Wisconsin--Madison, 1969. / eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references.
|
4 |
High voltage direct current interruptionRashid, Parvez. January 1979 (has links)
Thesis (M.S.)--University of Wisconsin--Madison. / Typescript. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 125-127).
|
5 |
Analysis of medium voltage vacuum switchgear through advanced condition monitoring, trending and diagnostic techniquesO'Reilly, Jan-Thomas January 2016 (has links)
A research report submitted to the Faculty of Engineering and the Built Environment, University of the Witwatersrand, Johannesburg, in partial fulfilment of the requirements for the degree of Master of Science in Engineering, 2015 / Electrical utilities are tasked with managing large numbers of assets that have long useful lives and are fairly expensive to replace. With emphasis on medium voltage vacuum circuit breakers, a key challenge is determining when circuit breakers are close to their end-of-life and what the appropriate action at that point in time should be. Condition-based maintenance, intended to “do only what is required, when it is required,” has been reported as the most effective maintenance strategy for circuit breakers. This dissertation provides an overview, together with laboratory measurements, on non-intrusive technologies and analytics that could reduce maintenance costs, unplanned outages, catastrophic failures and even enhance the reliability and lifetime of circuit breakers by means of a real-time condition monitoring and effective failure prevention maintenance approach. The key areas of research are the condition assessment of the mechanical mechanism based on coil current signature diagnosis, degradation detection of the main interrupting contacts through thermal monitoring and interrupter vacuum integrity assessment based on magnetron atmospheric condition (MAC) testing. The information from test results allows both immediate onsite analysis and trending of key parameters which enables informed asset management decisions to be taken. / GS2016
|
6 |
Effects of EHV power circuit breaker reclosing on power system stabilityRoumillat, Ulysses Charles 05 1900 (has links)
No description available.
|
7 |
A low-voltage high-resolution audio delta-sigma modulatorÇoban, Abdulkerim Levent 05 1900 (has links)
No description available.
|
8 |
A novel fault current limiterOtete, Andrew. Li, Hui. January 1900 (has links)
Thesis (M.S)--Florida State University, 2004. / Advisor: Dr. Hui Li, Florida State University, College of Engineering, Dept. of Electrical and Computer Engineering. Title and description from dissertation home page (viewed May 20, 2005). Includes bibliographical references.
|
9 |
Modeling of AC circuit breakers in the electromagnetic transients programPhaniraj, Viruru January 1986 (has links)
The objective of this research project was to develop and implement a model for an A.C circuit breaker in the Electromagnetic Transients Program (EMTP). Various models for the arcing process were evaluated, and the modified Mayr equation was chosen for the model. Other equations were added to demonstrate the generality of the algorithm developed.
Since the Electromagnetic Transients Program was not designed to accommodate directly elements whose resistance varies with time, such as an electric arc, several strategies for interfacing the model with the program were studied. The compensation method was selected, and was used for interfacing the circuit breaker model with the program.
After implementation of the model, it was validated by comparing its performance with experimentally verified results reported previously. In order to render the model more practical, an auxiliary breaker parameter estimation routine was developed and tested. / M.S.
|
10 |
Operating strategies to preserve the adequacy of power systems circuit breakersDam, Quang Binh. January 2009 (has links)
Thesis (M. S.)--Electrical and Computer Engineering, Georgia Institute of Technology, 2009. / Committee Chair: Meliopoulos, A. P. Sakis; Committee Member: Divan, Deepakraj M.; Committee Member: Harley, Ronald G.; Committee Member: Johnson, Ellis L.; Committee Member: Taylor, David G.
|
Page generated in 0.0474 seconds