91

Process control of power generation by means of a digital computer.

Cheung, Yat-sing. January 1971 (has links)
Thesis--M. Phil., University of Hong Kong. / Mimeographed.
92

Analysis and comparison of power loss and voltage drop of 15 kV and 20 kV medium voltage levels in the north substation of the Kabul power distrubution system by CYMDIST

Mehryoon, Shah M. January 2009 (has links)
Thesis (M.S.)--Ohio University, November, 2009. / Title from PDF t.p. Includes bibliographical references.
93

Electricity market reform : evidence from South America

Anaya Stucchi, Karim Lourdes January 2012 (has links)
No description available.
94

Production costing and plant dispatching for large electric utility systems

Ramirez, Federico Angel Antonio 08 1900 (has links)
No description available.
95

Design procedures for self-supporting transmission towers.

Hanna, Albert William Ghabbour. January 1971 (has links)
No description available.
96

Improved transmission line protection performance concerning high resistance faults.

Matshidza, Rhulani Daphney. January 2006 (has links)
ESKOM has relied primarily on impedance-based measurement protection relays for the protection of transmission lines. One of the main disadvantages of distance relays is the limited fault resistance measurement capability. High-resistance faults are characterised by low fault currents, therefore the impedance calculated would be much bigger and so the fault will appear to be beyond the protected line. The main aim of the study is to gain clear understanding of the capability of the existing relays used in Eskom Transmission network, to be able to give recommendations on the refinements to the transmission line protection philosophy required to improve future protection performance. Omicron relay tests, showed that the dynamic characteristics of the three selected relays which were tested covers more fault resistance than that of the normal static impedance and also that the effect of DC offset is negligible with regards to fault resistance measurement capability. Normally the relays have built in algorithms which are able to filter nuisance signals. Theoretical case study that compared the most used relays in Eskom Transmission was done and the results are documented. Settings recommendations to improve fault resistance coverage were deduced from the above study. Fault investigation by using digital simulations (Matlab simulations) has proven the lack of capability to operate for some impedance relays in some fault conditions, as the fault resistance sometimes moves fault impedance beyond relay characteristic even when actual . polarization of the relay is considered. Analysis of the protection performance in transmission proved that high resistance faults accounts for at least half of protection equipment performance index (PEPI) incidents. Finally the author made recommendations to improve the protection performance concerning high resistance faults. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2006.
97

A study of the electrical environment below HVDC transmission lines.

Govender, Dhevandhran. January 2008 (has links)
The main aim of this project was to determine the extent to which the study of electric fields and ions in a laboratory can be used to study the electrical environment below High Voltage Direct Current (HVDC) transmission lines. The focus of the study was to set up small scale laboratory experiments and to compare these results to actual line measurements and to software simulations. The laboratory tests were undertaken at the HVDC Centre at the University of KwaZulu-Natal (Westville Campus). The software simulations that were conducted as part of this study were done using EPRI TL 3.0 and Microsoft Excel. Initially tests conducted were the measurement of the induced voltage and corona leakage current on a floating object. The next set of laboratory tests conducted was the measurement of ion current density and the electric field at ground level. The ion current density was measured with a Wilson Plate (lm2) and the electric field at ground level was measured using a JCI static monitor field meter (JCI 140) and a Monroe (257D) Portable Electrostatic Fieldmeter, with an elevated earth plane. Measurements of ion current density and electric field at ground level were also taken under an operating HVDC transmission line (Cahora Bassa to Apollo), in order to compare the laboratory measurements and simulations with real line measurements. The results have shown that the electrical parameters (i.e. ion current, induced voltages, corona currents, electric field, ion density, space charge) are higher under the negative pole as compared to the positive pole. The results of the laboratory measurements show that the ion currents under the negative polarity are almost double the ion currents that were measured under positive polarity, while the electric field under negative polarity was 20 percent higher than under positive polarity. Measurements of the electric field show that the total electric field below the line is greatly enhanced when corona generated space charge is present. The results of the EPRI TL Workstation simulations show good correlation with the EXCEL® simulations. However, there was poor correlation between EPRI simulations and test line measurements in the laboratory. The EPRI simulations show good correlation to the measured electric field values below the Cahora Bassa line. The comparison between the actual measurements on the test line and the Cahora Bassa line showed poor correlation and this was attributed to factors such as scaling, laboratory size constraints, ion concentration in laboratory, line loading and wind speeds. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2008.
98

Voltage dip performance analysis.

Nzimande, Timothy M. January 2009 (has links)
The power quality performance of South African utilities has been regulated through the application of NRS 048-2 standard. The earliest edition of the power quality standard (NRS 048- 2:1996) defines compatibility levels for voltage dips in the form of annual dip limits for each voltage dip type. Actual measured utility dip performance has consistently resulted in higher dip numbers than the limits imposed in the standard. On the other hand, the dip limits were considered to be less restrictive by industrial customers. The revised power quality standard addresses the difficulties in managing voltage dip performance based on dip limits as specified in the first edition of NRS 048-2. This new philosophy does not define dip limits; instead, utilities are required to develop specific strategies to manage dip performance according to customer requirements. This research work develops an alternative approach to the management of dip performance as opposed to the application of dip limits. The study analyses measured voltage dip records for a steel-processing plant and a pulp and paper plant. The supply network for each plant is modelled to define dip influence zones as a function of fault locations. The principal results of this study are critical circuits, causes of dips, dip influence zones and the key elements of the proposed approach in communicating dip performance. The optimised approach was presented to and adopted by the customers involved. / Thesis (M.Sc.)-University of KwaZulu-Natal, Durban, 2009.
99

On power scheduling and strategic behavior in electricity markets

Nuchprayoon, Somboon 05 1900 (has links)
No description available.
100

Modeling of package and board power distribution networks using transmission matrix and macro-modeling methods

Kim, Joong-Ho 12 1900 (has links)
No description available.