• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 12
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 51
  • 51
  • 29
  • 28
  • 23
  • 20
  • 20
  • 14
  • 14
  • 13
  • 11
  • 10
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Impactos no sistema de proteção da rede de distribuição com a ligação de pequenas centrais hidrelétricas. / Impacts of small hydroeletric power plants on the distribution protection systems.

Koehler, Marcos 21 September 2006 (has links)
Geração Distribuída é uma expressão utilizada para designar a geração elétrica proveniente de locais próximos ou juntos de consumidores, não interferindo a potência, tecnologia ou fonte de energia empregada. Estudos indicam que, até o ano de 2010, 20% do total de geração (em termos mundiais) serão provenientes desta forma de obtenção, uma vez que se torna fático sua vantagem sobre a geração central, por oferecer economia em matéria de investimentos relacionados à transmissão, redução de perdas e melhoria acerca da estabilidade do serviço de energia elétrica. Exemplos de geração distribuída são observados em pequenas centrais hidrelétricas, eólicas, térmicas, fotovoltaicas e geradoras de emergência, por terem pequeno porte e serem integradas ao sistema elétrico. Voltandose por hora ao potencial hidráulico passível de exploração no país, associado por sua vez às pequenas centrais hidrelétricas, tem-se cerca de 4% da potência instalável total (parcela extremamente significativa). De acordo com o Plano 2.015 da ELETROBRÁS, centrais que atingem até 30 MW de potência instalada representam um potencial de 9.456 MW. Informações de Geração da ANEEL indicam que há cerca de 254 PCH em operação no país, totalizando 1327 MW (1,4% do total), 40 empreendimentos em construção (500 MW) e 211 projetos outorgados (construção não iniciada) que, se implantados, adicionarão ao sistema elétrico 3426 MW. O panorama da reordenação da matriz energética nacional não tem apresentado abundância no que diz respeito ao investimento público, direcionado a grandes empreendimentos. Desta forma, as quedas d´água de pequeno e médio porte representam uma evidente opção de geração. As Pequenas Centrais Hidrelétricas (PCH) surgem então como uma alternativa viável, como já especificado anteriormente. Oferece vantagens primeiramente pelo custo acessível, pelo menor prazo de implementação e maturação do investimento, pelas facilidades oferecidas pela legislação, pela disposição das concessionárias de energia elétrica de comprarem o excedente de energia gerada por autoprodutores e finalmente por disponibilizarem o acesso às suas linhas de distribuição e transmissão à longa distância. A partir do incentivo proveniente do Governo Federal para a construção de PCH e descontos nas tarifas de uso dos sistemas de transmissão e distribuição, propiciou-se a ligação de novos pontos de geração de energia no sistema de Distribuição. Com a finalidade de reduzir os custos de transportes de energia, visa-se a localização dos novos pontos de geração próxima aos pontos de consumo potencial. Sendo assim, na medida em que a rede garante a regulação de freqüência e a absorção permanente da potência total, os grupos serão equipados com geradores que não requerem controle com comando sofisticado. Há, todavia, a possibilidade da construção de interligações que devem ser estudadas mesmo quando se tratando de rede de pequeno porte. Sua vantagem está no fato de permitir a utilização de geradores assíncronos, os quais são menos onerosos e mais robustos. Os efeitos da geração nos sistemas de distribuição irão depender do tamanho, do tipo e do local onde será instalada a geração. Atualmente não se tem dado a devida importância aos impactos na proteção da rede de distribuição da concessionária - fato lamentável já que se poderia evitar a degradação da qualidade de energia, confiabilidade e operação - uma vez que se dá prioridade aos benefícios como a energia de backup, a redução dos afundamentos de tensão, a energia de ponta, dentre outras. A partir do momento em que estas PCH são instaladas nas redes de Distribuição, transforma-se um sistema anteriormente radial em um sistema em anel, com mais de uma fonte de contribuição de corrente de curtocircuito. Sendo assim, têm-se como diretrizes deste trabalho abordar temas relacionados aos problemas com falta de coordenação e sensibilidade dos equipamentos de proteção, bloqueio de religamento, necessidade de proteção de sobre-corrente com função direcional, coordenação com consumidores e ramais (gerando problemas de segurança com pessoas e equipamentos) e continuidade de energia. Portanto, é de suma importância a realização sistemática de estudos de proteção de redes com geração de PCH em paralelo, uma vez que é determinante para a segurança e melhoria dos índices de continuidade de serviço. Finalmente, são descritos e analisados detalhadamente, os impactos no sistema de proteção nas redes de distribuição com a ligação de Pequenas Centrais Hidrelétricas, sendo propostas soluções para a redução deste impacto. / Distributed Generation is an expression used to designate the electric generation source in places near or contiguous to consumers, regardless of the power, technology or energy source used. Studies show that, by the year 2010, 20% of the total amount of generation (worldwide) will be acquired this way. The advantages of distributed generation, over central generation, are obvious and include: lower investment needed for transmission, reduction of losses and better performance regarding stability in the electric energy service. Examples of distributed generation include: small hydro electrics, wind turbines, thermals, photovoltaics and emergency generators. These examples are small in size and are interconnected to the electric system. Hydraulic power, which is available through exploration in the country, could comprise about 4% of the total power to be generated (which is a verysignificant portion) in small hydro electrics. According to ELETROBRÁS´ Plan 2,015, a power station that reaches up to 30 MW of installed power represents a potential of 9,456 MW. ANEEL´ information about Generation shows that there are about 254 PCH in operation in the country, which total 1,327 MW (1.4% of the total), 40 enterprises under construction (500 MW) and 211 approved projects (construction has not yet begun) that, when finished, will add 3,426 MW to the electric system. Substantial public investments have not been directed toward the larger enterprises since the re-arrangement of the national energy center. Thus, small and medium sized waterfalls represent a very interesting generation option. The small hydro electrics (PCH) appear as a possible choice, as mentioned before. They offer advantages, such as affordable cost, a short implementation time required, return of investment, support through legislation, the willingness of the electric power utilities to buy the exceeded energy generated by selfproducers and, finally, the possibility of access to its distribution and transmission lines through long distances. The connection of new points of energy generation in the Distribution system was made possible with the support from the Federal Government, through encouragement for PCH constructions and tax discounts for use of the transmission and distribution systems. We plan on locating the new points of generation next to the points of potential consumers with the objective of decreasing energy transportation costs. Thus, as the network guarantees the regulation of frequency and the permanent absorption of the total power, groups are equipped with generators that do not require a sophisticated command control. There is, however, the possibility of building interconnections, which must be studied even when related to the small potency network. The advantage lies in the facts that asynchronous generators can be used - which are cheaper and stronger. The effects of generation on distribution systems will depend on size, type and location where the generation will be installed. The protection of the utilities distribution network should be assigned a higher priority. Instead, we prioritize the benefits of energy production, such as the backup energy, voltage sags, top-notch energy, among others. This is unfortunate, since the protection of the utilities distribution network will avoid the degradation of the energy quality, of reliability and of operations. From the moment that these PCH are installed on the Distribution networks, a radial system is turned into a ring system with more than one source of short-circuit current contribution. Thus, the guidelines for this work are the approach to topics related to problems with the lack of coordination and sensibility of protection equipment, re-connection blockage, necessity of protection of overcurrent with directional function, coordination with consumers and extension lines (causing security problems with people and equipment) and energy continuity. It is of great importance to perform systematic studies on the protection of networks with the simultaneous generation of PCH since they are essential for the security and improvement of the current levels of continuity of service. Finally, the impacts on the distribution system protection of networks with connections to Small Hydroelectric Centrals are described and analyzed in detail, followed by proposals of solutions for the reduction of such impacts.
22

Aplicação de sistemas multiagentes para gerenciamento de sistemas de distribuição tipo Smart Grids / Application of multiagent systems for management of distribution systems like Smart Grids

Filipe de Oliveira Saraiva 23 March 2012 (has links)
Os smart grids são tidos como a nova geração dos sistemas elétricos de potência, combinando avanços em computação, sistemas distribuídos e inteligência artificial para prover maiores funcionalidades sobre acompanhamento em tempo real da demanda e do consumo de energia elétrica, gerenciamento em larga escala de geradores distribuídos, entre outras, a partir de um sistema de controle distribuído sobre a rede elétrica. Esta abordagem alteraria fundamentalmente a maneira como se dá o planejamento e a operação de sistemas de distribuição, e há grandes possibilidades de pesquisa e desenvolvimento possibilitada pela busca de implementação destas funcionalidades. Com esse cenário em vista, o presente trabalho utiliza uma abordagem a partir do uso de sistemas multiagentes para estudar o gerenciamento de sistemas de distribuição, do ponto de vista da reconfiguração da topologia da rede, simulando as características de um smart grid. Nesta dissertação, foi desenvolvido um sistema multiagente para simulação computacional de um sistema de distribuição elétrico do tipo smart grid, buscando executar a reconfiguração topológica do sistema a partir de dados de carga capturados de forma distribuída pelos agentes dispersos na rede elétrica. Espera-se que o desenrolar da pesquisa conduza à vários estudos sobre algoritmos e técnicas que melhor implementem tais funcionalidades a serem transpostas para um ambiente de produção. / Smart grids are taken as the new generation of electric power systems, combining advances in computing, distributed systems and artificial intelligence to provide more features on real-time monitoring of demand and consumption of electricity, managing large-scale distributed generators, among others, from a distributed control system on the grid. This approach fundamentally alter the way how is the planning and operation of distribution systems, and there are great possibilities for research and development offered in the quest to implement these features. With that environment, this text uses an approach through the use of multi-agent systems to study the management of the distribution system, from the reconfiguration of grid topology, simulating the characteristics of a smart grid. In this text, was developed a multiagent system to computational simulation of a distribution system like smart grid to topological reconfiguration, from datas collected for agents in electrical grid. It is expected that the conduct of research leads to several studies about better algorithms and techniques that would implement such functionality in a production environment.
23

Impactos no sistema de proteção da rede de distribuição com a ligação de pequenas centrais hidrelétricas. / Impacts of small hydroeletric power plants on the distribution protection systems.

Marcos Koehler 21 September 2006 (has links)
Geração Distribuída é uma expressão utilizada para designar a geração elétrica proveniente de locais próximos ou juntos de consumidores, não interferindo a potência, tecnologia ou fonte de energia empregada. Estudos indicam que, até o ano de 2010, 20% do total de geração (em termos mundiais) serão provenientes desta forma de obtenção, uma vez que se torna fático sua vantagem sobre a geração central, por oferecer economia em matéria de investimentos relacionados à transmissão, redução de perdas e melhoria acerca da estabilidade do serviço de energia elétrica. Exemplos de geração distribuída são observados em pequenas centrais hidrelétricas, eólicas, térmicas, fotovoltaicas e geradoras de emergência, por terem pequeno porte e serem integradas ao sistema elétrico. Voltandose por hora ao potencial hidráulico passível de exploração no país, associado por sua vez às pequenas centrais hidrelétricas, tem-se cerca de 4% da potência instalável total (parcela extremamente significativa). De acordo com o Plano 2.015 da ELETROBRÁS, centrais que atingem até 30 MW de potência instalada representam um potencial de 9.456 MW. Informações de Geração da ANEEL indicam que há cerca de 254 PCH em operação no país, totalizando 1327 MW (1,4% do total), 40 empreendimentos em construção (500 MW) e 211 projetos outorgados (construção não iniciada) que, se implantados, adicionarão ao sistema elétrico 3426 MW. O panorama da reordenação da matriz energética nacional não tem apresentado abundância no que diz respeito ao investimento público, direcionado a grandes empreendimentos. Desta forma, as quedas d´água de pequeno e médio porte representam uma evidente opção de geração. As Pequenas Centrais Hidrelétricas (PCH) surgem então como uma alternativa viável, como já especificado anteriormente. Oferece vantagens primeiramente pelo custo acessível, pelo menor prazo de implementação e maturação do investimento, pelas facilidades oferecidas pela legislação, pela disposição das concessionárias de energia elétrica de comprarem o excedente de energia gerada por autoprodutores e finalmente por disponibilizarem o acesso às suas linhas de distribuição e transmissão à longa distância. A partir do incentivo proveniente do Governo Federal para a construção de PCH e descontos nas tarifas de uso dos sistemas de transmissão e distribuição, propiciou-se a ligação de novos pontos de geração de energia no sistema de Distribuição. Com a finalidade de reduzir os custos de transportes de energia, visa-se a localização dos novos pontos de geração próxima aos pontos de consumo potencial. Sendo assim, na medida em que a rede garante a regulação de freqüência e a absorção permanente da potência total, os grupos serão equipados com geradores que não requerem controle com comando sofisticado. Há, todavia, a possibilidade da construção de interligações que devem ser estudadas mesmo quando se tratando de rede de pequeno porte. Sua vantagem está no fato de permitir a utilização de geradores assíncronos, os quais são menos onerosos e mais robustos. Os efeitos da geração nos sistemas de distribuição irão depender do tamanho, do tipo e do local onde será instalada a geração. Atualmente não se tem dado a devida importância aos impactos na proteção da rede de distribuição da concessionária - fato lamentável já que se poderia evitar a degradação da qualidade de energia, confiabilidade e operação - uma vez que se dá prioridade aos benefícios como a energia de backup, a redução dos afundamentos de tensão, a energia de ponta, dentre outras. A partir do momento em que estas PCH são instaladas nas redes de Distribuição, transforma-se um sistema anteriormente radial em um sistema em anel, com mais de uma fonte de contribuição de corrente de curtocircuito. Sendo assim, têm-se como diretrizes deste trabalho abordar temas relacionados aos problemas com falta de coordenação e sensibilidade dos equipamentos de proteção, bloqueio de religamento, necessidade de proteção de sobre-corrente com função direcional, coordenação com consumidores e ramais (gerando problemas de segurança com pessoas e equipamentos) e continuidade de energia. Portanto, é de suma importância a realização sistemática de estudos de proteção de redes com geração de PCH em paralelo, uma vez que é determinante para a segurança e melhoria dos índices de continuidade de serviço. Finalmente, são descritos e analisados detalhadamente, os impactos no sistema de proteção nas redes de distribuição com a ligação de Pequenas Centrais Hidrelétricas, sendo propostas soluções para a redução deste impacto. / Distributed Generation is an expression used to designate the electric generation source in places near or contiguous to consumers, regardless of the power, technology or energy source used. Studies show that, by the year 2010, 20% of the total amount of generation (worldwide) will be acquired this way. The advantages of distributed generation, over central generation, are obvious and include: lower investment needed for transmission, reduction of losses and better performance regarding stability in the electric energy service. Examples of distributed generation include: small hydro electrics, wind turbines, thermals, photovoltaics and emergency generators. These examples are small in size and are interconnected to the electric system. Hydraulic power, which is available through exploration in the country, could comprise about 4% of the total power to be generated (which is a verysignificant portion) in small hydro electrics. According to ELETROBRÁS´ Plan 2,015, a power station that reaches up to 30 MW of installed power represents a potential of 9,456 MW. ANEEL´ information about Generation shows that there are about 254 PCH in operation in the country, which total 1,327 MW (1.4% of the total), 40 enterprises under construction (500 MW) and 211 approved projects (construction has not yet begun) that, when finished, will add 3,426 MW to the electric system. Substantial public investments have not been directed toward the larger enterprises since the re-arrangement of the national energy center. Thus, small and medium sized waterfalls represent a very interesting generation option. The small hydro electrics (PCH) appear as a possible choice, as mentioned before. They offer advantages, such as affordable cost, a short implementation time required, return of investment, support through legislation, the willingness of the electric power utilities to buy the exceeded energy generated by selfproducers and, finally, the possibility of access to its distribution and transmission lines through long distances. The connection of new points of energy generation in the Distribution system was made possible with the support from the Federal Government, through encouragement for PCH constructions and tax discounts for use of the transmission and distribution systems. We plan on locating the new points of generation next to the points of potential consumers with the objective of decreasing energy transportation costs. Thus, as the network guarantees the regulation of frequency and the permanent absorption of the total power, groups are equipped with generators that do not require a sophisticated command control. There is, however, the possibility of building interconnections, which must be studied even when related to the small potency network. The advantage lies in the facts that asynchronous generators can be used - which are cheaper and stronger. The effects of generation on distribution systems will depend on size, type and location where the generation will be installed. The protection of the utilities distribution network should be assigned a higher priority. Instead, we prioritize the benefits of energy production, such as the backup energy, voltage sags, top-notch energy, among others. This is unfortunate, since the protection of the utilities distribution network will avoid the degradation of the energy quality, of reliability and of operations. From the moment that these PCH are installed on the Distribution networks, a radial system is turned into a ring system with more than one source of short-circuit current contribution. Thus, the guidelines for this work are the approach to topics related to problems with the lack of coordination and sensibility of protection equipment, re-connection blockage, necessity of protection of overcurrent with directional function, coordination with consumers and extension lines (causing security problems with people and equipment) and energy continuity. It is of great importance to perform systematic studies on the protection of networks with the simultaneous generation of PCH since they are essential for the security and improvement of the current levels of continuity of service. Finally, the impacts on the distribution system protection of networks with connections to Small Hydroelectric Centrals are described and analyzed in detail, followed by proposals of solutions for the reduction of such impacts.
24

Tillförlitlighet i Stockholms elnät : En analys med hjälp av Tekla NIS

Lundh, Lisa January 2015 (has links)
Outages in the electric grid can be costly for society. Because of this, reliability is one of the parameters used to regulate network companies. Reliability in electrical grids can be measured with SAIDI, system average interruption duration index, which for Fortum Distribution has increased in Stockholm’s distribution network (11 kV) in the early 2000’s. By using outage data for Stockholm from 2011-2013, sets of parameters to be used for reliability calculations in the network information program Tekla NIS were derived. Two different options for investment were then analysed: changing old cables with high fault frequencies, and installing automatic switching in distribution substations. These options were also analysed in a simplified model built in Microsoft Excel. The model calculates the reliability of Stockholm’s distribution network using Markov chains and the network’s average line from a transmission substation’s feeder. The Excel model is faster than Tekla NIS but is limited and less detailed, however the results from Tekla NIS and the Excel model were found to be almost equivalent. The priority for reliability investments in Stockholm should be to change old cables of the type FCJJ since it increases the fault frequencies in the network, while an ageing network decreases the grid fees Fortum Distribution can charge. Simplifications and assumptions, due to insufficient outage data and some problems with Tekla NIS, had to be made when deriving parameters for reliability calculations in both Tekla NIS and the Excel model. However, Tekla NIS can be used to incorporate reliability analysis in network planning, but since Fortum Distribution currently only uses it sparsely, further testing and analysis of the programme is recommended if the usage is to increase. The Excel model can be used for making fast and rough estimates of the result of the two analysed options of investment. / <p>I den tillgängliga fulltexten är tre figurer med tillhörande information i kapitel 2.4 borttagna från originalrapporten efter önskemål från samarbetspartner.</p>
25

Análise do impacto da utilização do transporte elétrico coletivo no sistema elétrico de distribuição / Analysis of the impact of the use of the collective electric transport in the electrical distribution system

Baldissera, Luciano Bonato 26 August 2016 (has links)
The collective electric transport can be considered as one of the best alternatives to reduce the concentration of pollutants in urban centers, because it reduces the number of vehicles in circulation and eliminates most of the problems arising from the use of fossil fuels. Currently, in this alternative, there is a wide range of options available, however, with the advancement occurred in recent years in terms of battery technology, the pure electric bus has stood out due to advantages related to its flexibility, sustainability and adaptability to the existing infrastructure. However, the use of these vehicles requires special recharging stations, which drain a lot of energy of the grid, in a short time, a feature that generates a significant impact on electrical systems. Moreover, the high amount of energy required for the operation of these vehicles precludes the use of technology in certain places, because it requires large investments in infrastructure for power supply, which often do not is available locally in the short term. Based on this, this dissertation presents a study of the impact generated in the electrical distribution system caused by the replacement of a diesel bus fleet by electric buses in a small town in southern Brazil. The study was based on the measurement of energy consumption through data related to the lines and the vehicle driving cycle, applied to an electric bus model, it was developed with Matlab software. Actual data of the lines was used, as distance, speeds, tilt, number of passengers, among others, obtained through a GPS equipment and information provided by the company analyzed. At the end were generated values related to the energy consumption of vehicles in each of the lines, the electricity consumption increase generated by the substitution in question and an estimate of the daily load curves based on the operating hours of the analyzed lines. / O transporte elétrico coletivo atualmente pode ser considerado como uma das melhores alternativas para a redução da concentração de poluentes em centros urbanos, pois reduz o número de veículos em circulação e elimina a maioria dos problemas decorrentes do uso de combustíveis fósseis. Atualmente, neste tipo de alternativa existe uma vasta gama de opções disponíveis, entretanto, com o avanço ocorrido nos últimos anos em termos de tecnologia de baterias, os ônibus elétricos puros vem se destacando devido a vantagens relacionadas a sua flexibilidade, sustentabilidade e adaptabilidade as infraestruturas existentes. Porém a utilização destes veículos requer estações de recarga especiais, as quais causam um impacto significativo nos sistemas elétricos, pois geram um grande acréscimo de demanda de energia, o que em alguns casos pode sobrecarregar os sistemas. Além disso, a elevada quantidade de energia necessária para a operação destes veículos inviabiliza o uso da tecnologia em determinados locais, pois requer um alto investimento em infraestrutura para o fornecimento seguro e confiável de energia. Baseado nisto, esta dissertação apresenta um estudo do impacto gerado no sistema elétrico de distribuição ocasionado pela substituição de uma frota de ônibus a diesel por ônibus elétricos em uma cidade de pequeno porte situada no sul do Brasil. O estudo foi baseado na mensuração do consumo energético através de dados relacionados às linhas e ao ciclo de condução dos veículos, aplicados em um modelo de ônibus elétrico, o qual foi elaborado através do software Matlab®. Foram utilizados dados reais das distâncias nas linhas, velocidades, relevo das vias, número de passageiros, entre outros, obtidos através de um equipamento de GPS e informações fornecidas pela empresa analisada. Ao final foram gerados valores relacionados ao consumo dos veículos em cada uma das linhas, o acréscimo de consumo de energia elétrica gerado pela substituição em questão e uma estimativa das curvas de carga diárias baseadas nos horários de operação das linhas analisadas.
26

Electrical Power and Storage for NASA Next Generation Aircraft.

Al-Agele, Saif January 2017 (has links)
No description available.
27

Reconfiguração ótima de sistemas de distribuição de energia elétrica baseado no comportamento de colônias de formigas / Optimal reconfiguration of the electric power distribution systems using a modified ant colony system algorithm

Pereira, Fernando Silva 26 February 2010 (has links)
O objetivo deste trabalho é apresentar uma nova abordagem para obtenção de configurações para sistemas de distribuição de energia elétrica com o intuito de minimizar o valor de perdas ativas sem violar as restrições operacionais. Para isso, considera-se que os sistemas de distribuição estão operando em regime permanente e que suas fases estão equilibradas e simétricas, podendo o sistema ser representado por um diagrama unifilar. A reconfiguração é feita de forma a redistribuir os fluxos de corrente nas linhas, transferindo cargas entre os alimentadores e melhorando o perfil de tensão ao longo do sistema. O problema de reconfiguração do sistema pode ser formulado como um problema de programação não-linear inteiro misto. Devido à explosão combinatorial inerente a este tipo de problema, a resolução do mesmo por técnicas de otimização clássicas torna-se pouco atraente, dando espaço para técnicas heurísticas e metaheurísticas. Essas outras, mesmo não garantindo o ótimo global, são capazes de encontrar boas soluções em um espaço de tempo relativamente curto. Para a resolução do problema de reconfiguração, utilizou-se uma nova metodologia baseada no comportamento de colônias de formigas em busca de alimento na natureza. Nesta, formigas artificiais (agentes) exploram o meio ambiente (sistema de distribuição) e trocam informações para tentar encontrar a topologia que apresente os menores valores de perdas ativas. Para o cálculo das perdas, este trabalho também apresenta uma nova abordagem para resolução do problema de fluxo de potência (FP) em sistemas de distribuição radial. O fluxo de potência é uma ferramenta básica utilizada pelos centros de controle para determinar os estados e condições operacionais desses sistemas de potência. Basicamente, as metodologias empregadas para o cálculo do fluxo de potência são baseadas nos métodos clássicos de Newton ou Gauss. Mas em sistemas de distribuição de energia, devido a particularidades inerentes a estes, como a alta relação entre resistência e reatância das linhas (r/x) e a operação radial, estes métodos apresentam problemas de convergência e se tornam ineficientes na maioria das vezes. A abordagem consiste na associação dos métodos da função penalidade e de Newton. O mal-condicionamento da matriz Jacobiana de Newton é resolvido pela associação com o método da função penalidade. São apresentados testes realizados em sistemas de 5 barras, 16 barras, 33 barras, 69 barras e 136 barras para avaliar a potencialidade das técnicas propostas. Os resultados são considerados bons ou muito bons quando comparado com as técnicas existentes atualmente. / The objective of this work is to present a novel methodology for obtaining new configurations of the distribution system in order to minimize the active power losses without violating operational constraints. For this, it is considered that any distribution system is operating in a steady state and that it is balanced, therefore it can be represented by a one-line diagram. The reconfiguration is done in order to redistribute de current flows on the distribution power lines, transferring loads among the feeders and improving the voltage profile along the system. Such problem can be formulated as a mixed integer nonlinear programming problem. Due to its inherent combinatorial characteristic and since its solution by classic optimization techniques is not appealing, heuristic and metaheuristic techniques are thus better suited for its solution. Although these latter do not guarantee a global optimum, they are able to find good solutions in a relatively short time. The solution of the reconfiguration problem in this approach makes use of a novel methodology based on ant colony behavior, when these search for victuals in nature. In this technique, the artificial ants (agents) explore the environment (distribution system) and exchange information among them in order to find the topology that provides the smallest active losses. For the active losses calculation, this work also presents a novel approach for the solution of the power flow problem for radial distribution systems. The solution of the power flow problem is used by system operators in order to determine the state and operational conditions of power systems. Basically, the most common techniques used in the power flow solution are based on either Newton\'s or Gauss\' approaches. However, due to particular characteristics of distribution systems such as the high ratio of r/x and the radial topology, these methods present convergence problems and are not efficient in most of the cases. Thus, this novel technique consists in associating Newton\'s and the penalty function approaches. The matter of the ill-conditioned Jacobian matrix in Newton\'s method is overcome with the penalty function method. Some tests performed in different systems are then presented in order to assess the effectiveness of both proposed techniques.
28

Modelo estocástico parametrizável para o estudo de faltas de alta impedância em sistemas de distribuição de energia elétrica / Parameterizable stochastic model for high impedance fault study on electrical distribution systems

Trondoli, Luiz Henrique Pessôa da Costa 22 March 2017 (has links)
As Faltas de Alta Impedância (FAI) causadas pelo rompimento de um condutor da rede primária podem trazer risco à segurança pessoal e ao patrimônio. A detecção deste defeito se faz, portanto, necessária. Não há na literatura um método que estabeleça a solução definitiva para este problema. Ainda, os estudos, quando não baseados em sinais reais, utilizam, por vezes, modelos determinísticos ou que não representam por completo as características geradas pelo defeito. Por este motivo, este trabalho propõe um modelo de falta de alta impedância que visa representar, com elevado detalhamento, a natureza do evento. O modelo desenvolvido é parametrizável para que possa representar as características dos sinais de falta e suas variações, inclusive as não determinísticas, as quais se referenciam na literatura, reproduzindo o comportamento típico de uma falta de alta impedância. O programa de simulação computacional empregado para este fim foi o ATPDraw. Para a validação do sinal gerado pelo modelo, além da comparação visual com sinais de falta reais, foi elaborado um algoritmo de detecção de FAI, o qual busca por características do fenômeno já conceituadas na literatura, com o propósito de analisar o sinal da corrente de falta gerado pelo modelo quando inserido em um sistema de distribuição de energia elétrica. Foi observada a progressão temporal do fenômeno, desde o rompimento do condutor até a formação dos arcos voltaicos. Do sinal de falta, em síntese, foram observadas características como: assimetria, variação de assimetria, ocorrência de buildup, presença e variação dos componentes harmônicos e inter-harmônicos. A observação dessa variedade de características é necessária na detecção de FAI e é coerente com o modelo proposto, já que este é o único presente na literatura capaz de reproduzi-las simultaneamente. Dos casos de falta simulados, todos foram detectados pelo algoritmo de detecção, indicando que os sinais de falta de alta impedância produzidos pelo modelo possuem as características que ele foi projetado para gerar. / High Impedance Faults (HIF) caused by primary conductor rupture can pose personal safety risk and danger to property. Detection of this event is, therefore, required. There is no proposed method in the literature that establishes a decisive solution to this problem. Studies, when not based on real signals, sometimes use deterministic models or models that do not entirely represent the event\'s characteristics. For this reason, this research proposes a high impedance fault model that intend to represent, with high level of details, the nature of this event. The developed model is parametrizable so it can represent fault signal characteristic and its variations, reproducing the typical high impedance fault behavior. The software ATPDraw was used for this purpose. For model\'s behavior and signal validation, in addition to visual comparison with real HIF signals, a detection algorithm was developed, which searches for HIF characteristics presented on literature, with the intent of analyzing the fault current signal generated by the model when inserted on an electrical distribution system. The temporal progression of the event was observed from the conductor rupture until electric arc ignition. From the fault current, characteristics such as: asymmetry, asymmetry variation, buildup, presence and variation of harmonic and inter-harmonic frequencies were analyzed. The evaluation of this variety of characteristics is needed for HIF detection and it only makes sense because the proposed model is the only one presented in literature capable of reproducing of all them simultaneously. All detection tests resulted in positive identification, confirming that the proposed HIF model possesses the intended characteristics.
29

A detecção e a localização de faltas de alta impedância em sistemas de distribuição utilizando transformadas wavelets e redes neurais artificiais / Detection and location of high impedance faults in distribution systems using wavelets transforms and artificial neural networks

Fanucchi, Rodrigo Zempulski 01 September 2014 (has links)
A ocorrência de faltas em sistemas elétricos de distribuição de energia é algo indesejável, porém, inerente ao mesmo devido a sua topologia normalmente aérea. Entre essas faltas, destacam-se as de alta impedância devido às características de corrente de baixa magnitude que surgem quando de sua ocorrência. No presente trabalho, um método baseado em três módulos é apresentado para a detecção e localização de faltas de alta impedância (FAI). No Módulo 1, é realizado um monitoramento contínuo dos sinais de corrente de forma a detectar a ocorrência de uma descontinuidade que pode estar vinculada a ocorrência de uma FAI. Caso haja essa detecção, o Módulo 2 é ativado de forma a analisar se o evento é realmente uma FAI. Por último, depois de detectada a FAI, o Módulo 3 é inicializado e a localização da falta, estimada. Para possibilitar a análise do método proposto e validar os resultados obtidos, um sistema de distribuição real, em conjunto com todas as etapas do sistema de aquisição de dados, foi modelado no software ATP/EMTP. Essa modelagem foi validada a partir de dados reais obtidos quando da ocorrência em campo de um curto-circuito bifásico. Vale ressaltar que um estudo de caso referente à importância da detecção e localização de um evento relacionado a uma FAI em uma concessionária de energia foi também analisado no início do trabalho de forma a mostrar o possível impacto da localização de FAIs nos indicadores de qualidade de serviço na mesma. Pelos resultados observados, a abordagem como um todo se mostra promissora e passível de aplicação no sistema real simulado e avaliado. / The occurrence of faults in overhead distribution networks is undesirable but common based on its topology. Among these events, High Impedance Faults (HIF) is one of the most important due to the fact that it has a small magnitude current. In this dissertation, a modular three-phase method is presented to enable HIF´s detection and location in a distribution system. In the Module 1, the phase currents are monitored in order to detect a discontinuity that can be associated with a HIF´s occurrence. If the Module 1 detected a discontinuity, the Module 2 is initiated and it analyses if the event can be classified as a HIF. Finally, if the Module 2 returns the event as a HIF, the Module 3 is initiated and the possible location of the HIF is estimated. To enable analysis of the proposed method and to validate the results, a real-based distribution system and the acquisition system of a digital relay were modeled in ATP/EMTP software. In order to validate the model, a simulated twophase fault were compared with the data obtained in a real event occurred in the analyzed distribution system. In order to present the importance of detecting and locating a HIF to a distribution utility, a case study was developed in the beginning of its work. Its importance is based on the improvement of the service quality indicators. Based on the results, the proposed method seems to be promising and applicable in a real distribution system.
30

A detecção e a localização de faltas de alta impedância em sistemas de distribuição utilizando transformadas wavelets e redes neurais artificiais / Detection and location of high impedance faults in distribution systems using wavelets transforms and artificial neural networks

Rodrigo Zempulski Fanucchi 01 September 2014 (has links)
A ocorrência de faltas em sistemas elétricos de distribuição de energia é algo indesejável, porém, inerente ao mesmo devido a sua topologia normalmente aérea. Entre essas faltas, destacam-se as de alta impedância devido às características de corrente de baixa magnitude que surgem quando de sua ocorrência. No presente trabalho, um método baseado em três módulos é apresentado para a detecção e localização de faltas de alta impedância (FAI). No Módulo 1, é realizado um monitoramento contínuo dos sinais de corrente de forma a detectar a ocorrência de uma descontinuidade que pode estar vinculada a ocorrência de uma FAI. Caso haja essa detecção, o Módulo 2 é ativado de forma a analisar se o evento é realmente uma FAI. Por último, depois de detectada a FAI, o Módulo 3 é inicializado e a localização da falta, estimada. Para possibilitar a análise do método proposto e validar os resultados obtidos, um sistema de distribuição real, em conjunto com todas as etapas do sistema de aquisição de dados, foi modelado no software ATP/EMTP. Essa modelagem foi validada a partir de dados reais obtidos quando da ocorrência em campo de um curto-circuito bifásico. Vale ressaltar que um estudo de caso referente à importância da detecção e localização de um evento relacionado a uma FAI em uma concessionária de energia foi também analisado no início do trabalho de forma a mostrar o possível impacto da localização de FAIs nos indicadores de qualidade de serviço na mesma. Pelos resultados observados, a abordagem como um todo se mostra promissora e passível de aplicação no sistema real simulado e avaliado. / The occurrence of faults in overhead distribution networks is undesirable but common based on its topology. Among these events, High Impedance Faults (HIF) is one of the most important due to the fact that it has a small magnitude current. In this dissertation, a modular three-phase method is presented to enable HIF´s detection and location in a distribution system. In the Module 1, the phase currents are monitored in order to detect a discontinuity that can be associated with a HIF´s occurrence. If the Module 1 detected a discontinuity, the Module 2 is initiated and it analyses if the event can be classified as a HIF. Finally, if the Module 2 returns the event as a HIF, the Module 3 is initiated and the possible location of the HIF is estimated. To enable analysis of the proposed method and to validate the results, a real-based distribution system and the acquisition system of a digital relay were modeled in ATP/EMTP software. In order to validate the model, a simulated twophase fault were compared with the data obtained in a real event occurred in the analyzed distribution system. In order to present the importance of detecting and locating a HIF to a distribution utility, a case study was developed in the beginning of its work. Its importance is based on the improvement of the service quality indicators. Based on the results, the proposed method seems to be promising and applicable in a real distribution system.

Page generated in 0.1209 seconds