• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] THE STUDY OF ELECTRO-OSMOSIS IN RESIDUAL SOILS: DEVELOPMENT OF TEST EQUIPMENT AND METHODOLOGY / [pt] ESTUDO DA ELETRO-OSMOSE EM SOLOS RESIDUAIS DESENVOLVIMENTO DE EQUIPAMENTO E METODOLOGIA DE ENSAIO

BIDKAR MANUEL MONTERROSO RIVAS 09 September 2002 (has links)
[pt] A presente dissertação apresenta o estudo da eletro- osmose em um solo residual gnaissico em ambiente laboratorial. O foco do trabalho foi direcionado ao desenvolvimento de equipamento e metodologia de ensaio. Duas células foram desenvolvidas, uma para amostras indeformadas e outra para amostras reconstituídas em laboratório.Os resultados do programa experimental não contrastaram muito com os disponíveis na literatura técnica. Observou-se que o fluxo eletro-osmótico é proporcional ao gradiente elétrico aplicado e que apresentava um comportamento errático durante o decorrer do ensaio,possivelmente devido às reações causadas pela eletrocinese. A variação no teor de umidade através dos corpos de provas foram ínfimas. Um fato curioso foi a indepedência dos parâmetros que avaliam a eficiência eletro-osmótica em relação ao gradiente elétrico aplicado.Em relação ao consumo energético, verificou-se que o mesmo é maior durante os instantes iniciais do ensaio e tende a se estabilizar com o passar do tempo. Observou-se ainda, uma relação direta com o gradiente elétrico aplicado. Para fins de projeto, o consumo enérgético pode ser estimado como US$ 0,30 por kW.h/m3. / [en] The present dissertation presents a laboratory study of electro-osmosis in a residual soil from gneiss. The objective of this study was to develop test equipment and methodology. Two different cells were constructed,one for natural and the other for reconstituted material. The experimental results are consistent with technical literature values. It was observed that the electro-osmotic flow is proportional to the magnitude of the eletrical potential gradient and shoewd a some what erratic behaviour during the test, which could be due to the physical- chemical reactions through the soil caused by electrolysis. The variation of water content in the specimens was minimal. One curious fact was that the electroosmotic efficiency coefficient, which evaluates the electroosmotic efficiency , turned out to be independent from the eletrical potential gradient. The power expenditure was greater during the initial stages of the tests and tended to stabilise over the remaining time.It was observed a direct relation between the power expenditure and the eletrical potential gradient. For design purposes, the current cost of energy expenditure could be assumed as U21730 0,30 per KW.h/m³. There is a little variation in the temperature of electrolytes during tests. It was also observed that eletroosmotic flow can be improved by acidification of the solution.
2

Etude théorique et expérimentale de pompes électro-osmotiques et de leur utilisation dans une boucle de refroidissement de l'électronique de puissance

Berrouche, Youcef 21 October 2008 (has links) (PDF)
Cette thèse a pour objectif d'étudier les potentialités des pompes électrocinétiques pour des applications de type refroidissement de composants de l'électronique de puissance. En effet, les pompes mécaniques utilisées aujourd'hui présentent des problèmes en terme de fiabilité, de bruit, de coût et de volume. Après une étude bibliographique et comparative entre les différentes pompes statiques fonctionnant à partir d'un champ électrique, nous avons choisi d'étudier plus en détail les pompes électro-osmotiques poreuses. Une modélisation de ce type de pompe a été proposée et validée expérimentalement. Nous avons également développé une formulation analytique de l'efficacité thermodynamique optimale d'une pompe électroosmotique poreuse. Deux types de fonctionnement ont été abordés dans cette thèse : une étude avec une tension continue et une autre étude avec une tension alternative. Nous avons mis en oeuvre la pompe fonctionnant en alternatif dans une boucle de refroidissement diphasique. Une densité de flux de 100W/cm2 a pu être évacuée. D'autres applications industrielles de la pompe électro-osmotique ont également été envisagées.
3

Étude rhéologique des électrolytes confinés en appareil à forces de surfaces dynamique / Rheological behavior of confined electrolytes with dynamic surface forces apparatus

Garcia, Léo 29 September 2016 (has links)
Cette thèse de doctorat présente une étude expérimentale des propriétés rhéologiques d’électrolytes confinés et de la mécanique des doubles couches électrostatiques.Afin d’étudier simultanément les propriétés d’équilibre et de transport d’électrolytes confinés proches de parois électriquement chargées, nous avons développé un appareil à forces de surfaces dynamique. Cette technique combine à la fois des mesures à l’équilibre, à l’instar des appareils à forces de surfaces classiques, et des mesures dynamiques permettant de caractériser les phénomènes de transport.Nous avons tout d’abord étudié le cas d’électrolytes très dilués. Nous avons montré l’existence d’une sur-dissipation induite par les ions issus des électrolytes par rapport à un comportement newtonien classique. De plus, nous avons mis en évidence un comportement élastique des doubles couches électrostatiques dépendant de la fréquence. Une approche théorique vient compléter et expliquer en partie les résultats expérimentaux.Enfin nous nous sommes intéressés à la dynamique d’électrolytes concentrés : les liquides ioniques. Nous avons étudié l’influence, sur la viscosité et les propriétés du liquide à l’interface solide-liquide, d’un champ électrique intense appliqué perpendiculairement à l’écoulement, comme rencontré dans les super-condensateurs. / This thesis presents an experimental study of rheological properties of confined electrolytes and mechanics of electric double layer.In order to study simultaneously equilibrium and transport of confined electrolytes nearby charged surfaces, we developed a dynamic surface force apparatus. This technique enables both steady state measurements, as provided by common surface forces apparatus, and dynamic measurements that allow characterizing the transport phenomenona.First, we showed the existence of an over-dissipative behavior of weak electrolytes compared to a classical newtonian fluid. Furthermore we highlighted a frequency dependence of the EDL elastic behavior. Alongside, a theoretical approach completes and explains partially the experimental observations.Finally we studied the dynamics of ionic liquid, a type of concentrated electrolytes. We looked at the influence of a huge electric field, applied perpendicularly to the surfaces, on the viscosity and the properties of the liquid nearby the surfaces, as found in super-capacitors.
4

Intégration d’une méthode d’actuation électrocinétique sur biocapteur plasmonique / Integrating an electrokinetic actuation method on a plasmonic biosensor

Avenas, Quentin 20 December 2018 (has links)
Cette thèse porte sur le développement d’un capteur plasmonique intégrant une fonction d’actuation des objets visés. L’objectif est de passer outre la limite de diffusion rencontrée à basse concentration en piégeant les particules sur la surface de détection. La stratégie adoptée est de structurer le film d’or servant à la détection de manière à pouvoir l’utiliser pour mettre en mouvement le fluide et les molécules par le biais de champs électriques. Le transfert de masse est réalisé par diélectrophorèse et électroosmose, deux effets électrocinétiques mis en oeuvre par des électrodes servant à la fois d’actuateur et de capteur plasmonique. Un état de l’art exhaustif et des simulations multiphysiques ont permis de concevoir un prototype de capteur intégré constitué d’électrodes interdigitées en or permettant la détection plasmonique. Le dispositif proposé a été obtenu par microfabrication en salle blanche puis caractérisé avant l’étude de ses performances. Une première phase de tests sur un système modèle, des billes de polystyrène dans de l’eau, a permis d’apporter la preuve de concept du fonctionnement du capteur, qui est effectivement capable de piéger rapidement les objets visés à sa surface afin de les détecter. Les mécanismes de transfert de masse ont été expliqués et la preuve de l’amélioration de la limite de détection par un facteur supérieur à 100 a été apportée. Dans un second temps, les performances du capteur appliqué à des objets biologiques ont été évaluées. Celui-ci piège efficacement des levures et des protéines, mais aucune amélioration n’a été observée dans le cas de la détection spécifique de l’hybridation entre deux brins d’acide désoxyribonucléique (ADN). Les causes de ce résultat ont été discutées et comprises et deux solutions différentes ont été explorées : l’adaptation de la fréquence d’opération et l’optimisation de la géométrie des électrodes. Ainsi, cette étude a permis de souligner la problématique de la mise en oeuvre d’effets électrocinétiques dans des milieux biologiques et de réfléchir aux pistes pertinentes pour sa résolution. / This thesis focuses on the development of an integrated plasmonic sensor capable to perform mass transport on targeted objects. The goal is to overcome the diffusion limit by trapping particules directly on the sensing surface. The adopted strategy was to structure the gold layer used for plasmonic detection in order to use the sofabricated structures to set the fluid and the molecules in motion by applying electric fields in the fluid. The mass transfer is realized through dielectrophoresis and electroosmosis, those two electrokinetic effects being operated by electrodes acting as sensor and actuator at the same time. An exhaustive state of the art as well as multiphysical simulations allowed us for designing a prototype for an integrated sensor consisting in gold interdigitated electrodes enabling plasmoninc sensing. The proposed device was obtained through microfabrication in clean room facilities and was characterized before the study of its performances. A first sequence of tests on a model system – polystyrene microbeads in water – brought the proof of concept we needed to validate the correct operation of the sensor, which is indeed capable of quickly trapping targeted objects on its surface and detecting them. The mass transfer mechanisms were explained and we showed the enhancement of the limit of detection by a factor greater than 100. In a second phase, performances of the sensor applied to biological objects were evaluated. It can effectively trap yeasts and proteins but no enhancement has been observed while detecting DNA hybridization events. Causes for this result were discussed and understood and two different solutions were explored: the adaptation of the operating frequency and the optimization of the electrodes geometry. Thus, this study highlighted the problematic of operating electrokinetic effects in biological media and suggested relevant leads towards its resolution.

Page generated in 0.058 seconds