• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito da variação do pH em modelo de ciclagem nas propriedades de materiais restauradores /

Silva, Kélio Garcia. January 2004 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da variação do pH da solução desmineralizante em modelo de ciclagem de pH na dureza de superfície, liberação de flúor e característica de superfície dos materiais restauradores: Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom e Fluorofil. Foram confeccionados, para cada material, 34 corpos-de-prova que tiveram a dureza de superfície inicial (DSI) determinada após a confecção. A seguir, foram divididos em 5 grupos (n=30) de acordo com a variação de pH (4,3; 4,6; 5,0; 5,5 e 6,2) da solução desmineralizante e submetidos a períodos cíclicos em solução desmineralizante (Des-6 horas) e remineralizante (Re-18 horas) por 15 dias. Decorrido este período, verificou-se a dureza de superfície final (DSF) e a característica de superfície (n=24). As soluções armazenadas diariamente foram utilizadas para a determinação da concentração de flúor (Des+Re). As variáveis DSI, DSF e alteração de dureza de superfície (% ADS) foram submetidas à análise de variância e a liberação de flúor ao teste de Kruskal-Wallis (p<0,05). A variação do pH proporcionou relação direta quando se comparou a dureza e inversa para a liberação de flúor nos cimentos de ionômero de vidro. Para as resinas compostas modificadas por poliácidos foi verificada relação inversa para a liberação de flúor, não havendo correlação na dureza. A característica de superfície foi influenciada pela variação do pH, ficando mais evidente nos menores pHs, exceto para as resinas compostas modificadas por poliácidos. Baseados nos resultados, concluiu-se que a variação do pH da solução desmineralizante do modelo de ciclagem influenciou a liberação de flúor dos materiais testados. Essa variação alterou a dureza e a característica de superfície dos cimentos de ionômero de vidro, mas não das resinas compostas modificadas por poliácidos. / Abstract: The aim of this study was to evaluate the effect of pH of the demineralizing solution in a cycling model on surface hardness, fluoride release and surface aspects of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty-four specimens of each material were made and surface hardness was measured. Then, the specimens were randomized in five groups (n=30), according to pH (4.3; 4.6; 5.0; 5.5; and 6.2) of the demineralizing solution and submitted to a cycling model during 15 days. The specimens remained in the demineralizing solution for 6 hours and in the remineralizing solution for 18 hours. After that, surface hardness was measured again and surface aspects were observed (n=24). Fluoride concentration was determined daily in all solutions (De+Re). Data from SMH (before and after pH-cycling) and %SMHC were analyzed by analysis of variance (p<0.05); Kruskal-Wallis test was carried out for the results of fluoride release. For glass ionomer cements, the variation of pH led to a direct relationship when hardness was compared and to an inverse relationship with regards to fluoride release. For polyacid-modified resin composites, an inverse relationship was found regarding fluoride release; no correlation was observed with regards to hardness. Surface aspect was influenced by pH variation: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. It was possible to conclude that pH of the demineralizing solution did influence fluoride release from the tested materials. The pH variation altered hardness and surface aspects of glass ionomer cements, but it did not influence polyacid-modified resin composites in those analysis. / Orientador: Denise Pedrini / Coorientador: Alberto Carlos Botazzo Delbem / Mestre
2

Estudo do controle biológico dos nematóides dos citros no Estado de São Paulo /

Martinelli, Paulo Roberto Pala. January 2008 (has links)
Orientador: Jaime Maia dos Santos / Banca: Maria Amélia dos Santos / Banca: José Carlos Barbosa / Resumo: Embora numerosas espécies de fitonematóides já tenham sido encontradas em pomares de citros em todo o mundo, poucas são consideradas pragaschave da cultura. No Brasil, apenas o nematóide dos citros (Tylenchulus semipenetrans Cobb) e o nematóide das lesões radiculares dos citros (Pratylenchus jaehni Inserra et al.) detêm esse status. Entre esses, T. semipenetrans é o mais distribuído, enquanto P. jaehni é o mais agressivo. Essa praga já foi encontrada em pomares de mais de 30 municípios paulistas, dois mineiros e três paranaenses. O objetivo deste estudo foi isolar, identificar, documentar ao microscópio fotônico e eletrônico de varredura e avaliar a eficácia de fungos nematófagos para o controle biológico dos nematóides dos citros (P. jaehni e T. semipenetrans). Foram analisadas 38 amostras coletadas em pomares de citros de municípios paulistas e goiano no Laboratório de Nematologia da UNESP/FCAV, Câmpus de Jaboticabal-SP. Dessas amostras, foram isolados Arthrobotrys robusta de 23,7% das amostras, A. musiformis de 18,4%, A. oligospora de 10,5% e A. conoides de 5,2%. Monacrosporium elegans, M. eudermatum, Dactyllela leptospora e Paecilomices lilacinus foram encontrados em 2,6% das amostras. Do total de 26 isolados dos fungos obtidos, 92,8% foram patogênicos a T. semipenetrans e 82,1% a P. jaehni. Um isolado de cada espécie desses fungos foi incluído na documentação das características mais marcantes ao microscópios fotônico e eletrônico de varredura. Em testes in vitro, foram selecionados isolados de cinco espécies de fungos nematófagos, sendo Monacrosporium eudermatum, Dactylella leptospora, Arthrobotrys musiformis, A. conoides e Paecilomyces lilacinus formulados para T. semipenetrans. Para P. jaehni, foram formulados Arthrobotrys robusta, A. oligospora, A. musiformis, Dactylella leptospora e Monacrosporium eudermatum...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Although many species of nematodes have already been found in orchards of citrus in the world, few are considered key pests of the culture. In Brazil, only the citrus nematode (Tylenchulus semipenetrans Cobb) and the lesion nematode of citrus (Pratylenchus jaehni Inserra et al.) have that status. Between these, T. semipenetrans is more distributed, but P. Jaehni is the most aggressive. This pest has been found in orchards of more than 30 counties in São Paulo State, two in Minas Gerais and three in Paraná State. The aim of this study was to isolate, identify, document and assess the effectiveness of nematophagous fungi for the biological control of the citrus nematode (P. jaehni and T. semipenetrans). Were analyzed 38 samples collected in the citrus orchards of Counties of Sâo Paulo State and one in Goiás, in Laboratório de Nematologia of UNESP/FCAV, Câmpus of Jaboticabal, SP. From these samples were isolated Arthrobotrys robusta, 23.7% of the samples, A. musiformis 18.4%, A. oligospora 10.5% in A. conoides 5.2%. Monacrosporium elegans, M. eudermatum, Dactyllela leptospora and Paecilomices lilacinus were found in 2.6% of samples. From a total of 26 isolates of the fungi obtained, 92.8% were pathogenic to T. semipenetrans and 82.1% to P. Jaehni. An isolate from each species of these fungi was included in the documentation of the most remarkable characteristics at the light microscope and scanning electron microscope. In tests in vitro were selected five isolates of nematophagous fungi being Monacrosporium eudermatum, Dactylella leptospora, Arthrobotrys musiformis, A. conoides and Paecilomyces lilacinus formulated for T. Semipenetrans. For, P. Jaehni were formulated Arthrobotrys robusta, A. oligospora, A. musiformis, Dactylella leptospora and Monacrosporium eudermatum. These fungi have been applied in doses of 1, 2, 4 and 6 liters of a formulation consisting of equal parts of mixing ...(Complete abstract, click electronic access below) / Mestre
3

Novo formato de pilar protético em zircônia estabilizada por Itría (Y-Tzp) para implantodontia desenvolvido pela técnica de slip casting /

Silva, Lucas Hian da. January 2011 (has links)
Orientador: Rubens Nisie Tango / Banca: Alexandre Luíz Souto Borges / Banca: Sebastião Ribeiro / Resumo: O objetivo deste estudo foi desenvolver um novo formato de pilar protético estético em zircônia (3Y-TZP) visando suprimir a utilização do parafuso trespassante utilizado no formato convencional de pilares protéticos em zircônia. Inicialmente foi feita a caracterização do material utilizado na técnica de colagem de barbotina (slip casting) através da confecção de uma barra que teve suas propriedades mecânicas, módulo de elasticidade (E) e coeficiente de Poisson (), grau de contração e dimensão de suas partículas após sinterização avaliados pelos métodos de frequências naturais de vibração e microscopia eletrônica de varredura (MEV), respectivamente. Previamente à confecção do pilar protótipo, este teve seu comportamento mecânico avaliado e comparado a um pilar de 3YTZP convencional com parafuso trespassante pela análise por elementos finitos (FEA) durante sua instalação em implante e recebendo carga oblíqua simulando força de mastigação (210,5 N). O protótipo foi confeccionado pela técnica de colagem de barbotina em um molde de gesso obtido a partir de uma duplicata ampliada em cera. A densidade final foi avaliada pelo método de Archimedes em água. Obteve-se o módulo de elasticidade de 187,97 ± 4,84 GPa e coeficiente de Poisson de 0,19 ± 0,04 para o material. O grau de contração de sinterização foi de 58 vol% e o tamanho do grão foi de 0,705 ± 0,424 μm. Na análise por FEA verificou-se concentrações de tensões na região inicial da rosca para ambos os pilares, e durante o carregamento foram observadas tensões de tração no lado em que incidiu a carga, com presença de tensões de compressão no lado oposto. Ainda, observou-se durante o carregamento do pilar protético convencional concentração de tensão na região do pescoço do parafuso trespassante. A densidade final obtida para o pilar protótipo em 3Y-TZP foi de 95,68% em ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to develop a new esthetic zirconia (3YYTZP) implant abutment shape to suppress the use of the fixing screw commonly used by the conventional zirconia abutments. A material characterization, Young's modulus (E), Poisson's rate (), shrinkage and particles dimensions after sintering was performed for a bar shape specimen obtained by slip casting evaluated by the natural torsional and flexural vibration frequencies and scanning electron microscope (SEM), respectively. Previously to the prototype abutment confection, its mechanical behavior was evaluated and compared to a conventional zirconia abutment with a fixing screw by finite element analisys (FEA) simulating the abutment installation and oblique loading (210.5 N). The prototype was confectioned by the slip casting technique using a gypsum mould obtained from a wax expanded replica. The abutment had its density measured by Archimedes' method. Through the natural vibration frequencies a Young's modulus of 187.97 ± 4.84 GPa and a Poisson's rate of 0.19 ± 0.04 were obtained for the material. The shrinkage was 58 vol% and the grain size was 0,705 ± 0,424 μm . The FEA showed stress concentration at the first thread pitch for both abutments, and tensile stress concentration were observed at the side that received the oblique load with compressive stress at the opposite side. Whereas, for the conventional abutment model a stress concentration was observed at the screw's stem. The final density for the zirconia prototype abutment was 95.68% from the theoretical density (6.12 g.cm-3). The zirconia abutment obtained by slip casting presented satisfactory physical properties. The suppressing of the fixing screw could provide better performance to the abutment due to the lack of stress concentration in the screw when an oblique load is applied, when evaluated by FEA / Mestre

Page generated in 0.0841 seconds