• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • Tagged with
  • 41
  • 41
  • 41
  • 39
  • 36
  • 13
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Plataforma regular versus switching : estudo mecânico por meio de testes laboratoriais de fadiga e análise de elementos finitos em implantes com hexágono externo e interno /

Freitas Júnior, Amilcar Chagas. January 2011 (has links)
Orientador: Eduardo Passos Rocha / Banca: Wirley Gonçalves Assunção / Banca: Idelmo Rangel Garcia Júnior / Banca: Paulo Guilherme Coelho / Banca: Paulo Francisco César / Resumo: Proposição. O objetivo do presente trabalho foi avaliar a influência do conceito de plataforma switching na confiabilidade e modo de falha de restaurações unitárias sobre implante com hexágono externo ou interno na região anterior da maxila. Adicionalmente, análises de elementos finitos foram realizadas para avaliar o padrão de distribuição de tensão dentro do complexo pilar-implante e no tecido ósseo peri-implantar. Materiais e Métodos. 84 implantes foram divididos em 4 grupos (n = 21) para realização dos testes de fadiga: SWT-EH e REG-EH (implantes de conexão externa com plataforma switching ou regular, respectivamente); SWT-IH e REG-IH (implantes de conexão interna com plataforma switching ou regular, respectivamente). Análises estatísticas de Weibull foram realizadas considerando as missões de 50.000 ciclos a 210N e 300N. Adicionalmente, foram construídos 4 modelos de elementos finitos considerando as mesmas variáveis para obtenção das tensões equivalentes de von Mises (σvM) no complexo pilar-implante e das máximas tensões principais (σmax) no osso peri-implantar. Resultados. Os valores de Beta para os grupos SWT-EH (1,31), REG-EH (1,55), SWT-IH (1,83) e REG-IH (1,82) indicaram que a fadiga acelerou a falha em todos os grupos. Os valores de confiabilidade calculados para os grupos SWT-EH, REG-EH, SWT-IH e REH-IH foram 0,53 (0,33 - 0,70), 0,93 (0,80 - 0,97), 0,99 (0,93 - 0,99) and 0,99 (0,99 -de tensão estiveram no pilar (SWT-IH = 186 MPa e REG-IH = 88.8 MPa). No osso cortical, os implantes com plataforma switching geraram menor tensão (σmax) tanto para conexão externa (SWT-EH = 49.0 MPa e REG-EH = 56.5 MPa) como para conexão interna (SWT-IH = 37.7 MPa e REG-IH = 45.5 MPa)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose. The aim of the present study was to evaluate the effect of platform switching concept on reliability and failure modes of anterior single-unit restorations for internal and external hex implants. Additionally, finite element analysis were performed to assess the stress distribution within implant-abutment complex and peri-implant bone. Materials and Methods. 84 implants were divided in 4 groups (n=21) for fatigue tests: REG-EH and SWT-EH (regular and switched-platform implants with external connection, respectively); REG-IH and SWT-IH (regular and switched-platform implants with internal connection, respectively). Weibull analysis for a mission of 50,000 cycles at 300N was performed. Additionally, 4 three-dimensional finite element models reproducing the characteristics of specimens used in mechanical tests were created to evaluate the equivalent von Mises stress (σvM) within implant-abutment complex and the maximum principal stress (σmax) in the peri-implant bone. Results. The Beta values for groups SWT-EH (1.31), REG-EH (1.55), SWT-IH (1.83) and REG-IH (1.82) indicated that fatigue accelerated the failure of all groups. The calculated reliability for groups SWT-EH, REG-EH, SWT-IH and REH-IH were 0.53(0.33-0.70), 0.93(0.80-0.97), 0.99(0.93-0.99) and 0.99(0.99-1.00), respectively. Failure modes (screw and/or abutment fracture) were similar for regular and switched-platform implants. Within implant-abutment complex, the higher peak of stress (σvM) was observed in fixation screw (SWT-EH = 190 MPa and REG-EH = 160 MPa) for groups with external hex implants; while for groups with internal hex implants was in abutment (SWT-IH = 186 MPa and REG-IH = 88.8 MPa). In the cortical bone... (Complete abstract click electronic access below) / Doutor
2

Análise de corrosão, dureza e fratura de conjuntos implantes / componentes protético de Titânio c.p., após serem submetidos a ciclos de fadiga em um meio fluoretado com diferentes PH /

Vaz, Luis Geraldo. January 2007 (has links)
Resumo: Atualmente o titânio é empregado como biomaterial devido à sua biocompatibilidade e resistência à corrosão. Entretanto, íons fluoretos, freqüentemente empregados em dentifrícios bucais, podem interferir no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de fadiga, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, 7,4 e 5,3, mediante imersão das amostras nesses meios durante 184 horas e também em água destilada, grupo controle. As amostras foram testadas num durômetro Micromet 2001 (500gf/30s). Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de fadiga realizados em uma máquina de ensaios mecânicos MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV foram constatadas evidências de corrosão na superfície das amostras após ação de íons fluoretos, entretanto pelo EDS não se verificou incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas. / Abstract: Titanium has been widely used as biomaterial owing to its excellent corrosion resistance, mechanical properties and biocompatibility. However, it has been reported that fluoride-containing environments can attack titanium. The aim of this study was evaluated fluoride environments influence with different pH values in the implant/abutment sets. The implants were separated into 3 groups containing 7 implants/brand: one was submerged in acid fluoride environment (NaF 1500ppm 184h pH 5.3), one in neutral fluoride environment (NaF 1500ppm 184h pH 7.4), and other group in distillated water, simulating five years of dental hygiene. Hardness and surface texture were evaluated before and after fluoride exposition by Vickers method (500gf/30s) and scanning electron microscopy (SEM), respectively. The fatigue test was performed with 100.000 load cycles, 15 Hz and 150 N. There was decrease in hardness in implants submitted to the fluoride environment. SEM and EDS evaluation showed dark stains in all implants, irrespective of fluoride pH, resulting from pitting corrosion process. All sets supported the fatigue test until 100.000 load cycles. The results demonstrated that fluoride environment there was no influence in mechanical properties of the implant/abutment sets.
3

Estudo comparativo in vivo de implantes Ti-cp com superfícies comerciais e modificadas por laser sem e com depósito de sílica : análises biomecânica, topográfica e histomorfométrica /

Souza, Francisley Ávila. January 2010 (has links)
Resumo: Proposição: O objetivo deste estudo foi comparar o comportamento biológico e mecânico do tecido ósseo ao redor de implantes de superfícies comerciais modificada por condicionamento ácido (SA), e usinada (SU), com implantes de superfícies experimentais modificada por laser (SL), e modificada por laser com depósito de sílica (SS), empregando-se as análises biomecânica, topográfica e histométrica. Material e Métodos: Trinta coelhos receberam 120 implantes de 3,75x10mm em suas tíbias direita e esquerda, sendo dois implantes de cada superfície por tíbia. O implante localizado mais superior, instalado na metáfise tibial foi utilizado para o ensaio biomecânico, descrito no capítulo I; e o implante localizado abaixo deste, instalado na epífise tibial foi utilizado para o estudo histométrico, descrito no capítulo II. A morfologia das superfícies dos implantes foi analisada por microscopia eletrônica de varredura (MEV), e por espectroscopia de energia dispersiva de raios X (EDS) antes, e após 4 semanas de implantação e remoção por torque reverso. Medidas de rugosidade e secção transversal foram obtidas. Após períodos de 4, 8, e 12 semanas realizou-se o ensaio biomecânico, e após os animais sofreram eutanásia. As peças do implante localizado na epífise tibial foram levadas ao micrótomo para corte sem descalcificação. A análise histométrica foi realizada empregando-se microscopia óptica. Foi mensurada a extensão linear de contato entre osso e implante (ELCOI), e a área óssea (AO). Uma lâmina de cada superfície do período de 4 semanas foi metalizada para realização da análise do mapeamento elementar por MEV-EDS. Resultados: A caracterização topográfica mostrou diferenças entre as superfícies analisadas, e os valores de rugosidade média das SL e SS foram estatisticamente superiores (p<0,05) a SA. Na comparação estatística dos valores obtidos... (resumo completo, clicar acesso eletrônico abaixo) / Abstract: Purpose: The aim of this study was to compare the biologic and mechanical behavior of bone tissue around implants with commercially available surfaces, modified by acid etching (SA), and machined surfaces (SU), with the experimental surfaces modified by laser (SL), and modified by laser with silica deposition (SS), using biomechanical, topographic and histometric analyses. Materials and Methods: Thirty rabbits received 120 implants measuring 3,75x10mm in their right and left tibias, being two implants of each type of surface per tibia. The implant located in the uppermost position, inserted in the tibial metaphysis, was used for the biomechanical test, described in Chapter I; and the implant located below this, inserted in the tibial epiphysis, was used for the histometric study, described in Chapter II. The morphology of the implant surfaces was analyzed by scanning electron microscopy (SEM) and by energy dispersive X-ray spectrometry (EDS) before and after 4 weeks of implantation and removal by reverse torque. Mean roughness and cross-sectional measurements were obtained. After periods of 4, 8, and 12 weeks the biomechanical test was performed, and after this the animals were euthanized. The parts of the implant located in the tibial epiphysis were taken for cutting nondecalcified on a microtome. Histometric analysis was performed using an optical microscope. The bone interface contact (BIC), and the bone area (AO) were measured in percentages. A slide of each surface in the period of 4 weeks was metalized in order to analyze the element mapping by means of SEM-EDS. Results: The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of SL and SS were statistically higher (p<0,05) than those of SA. In the statistical comparison of the values obtained by the biomechanical test, it was... (Complete abstract click electronic access below) / Orientador: Celso Koogi Sonoda / Coorientador: Roberta Okamoto / Banca: Antônio Carlos Guastaldi / Banca: Renato Sussumu Nishioka / Banca: Sérgio Bruzadelli Macedo / Banca: Idelmo Rangel Garcia Júnior / Banca: Osvaldo Magro Filho / Doutor
4

Avaliação clínica e da freqüência de ressonância, de implantes instalados por meio de técnica cirúrgica modificada na maxila e submetidos à função imediata /

Vasconcelos, Laércio Wonhrath. January 2005 (has links)
Orientador: Paulo Sérgio Perri de Carvalho / Banca: Marco Antonio Bottino / Banca: Carlos Eduardo Francischone / Banca: Waldyr Antonio Janson / Banca: Per-Ingvar Branemark / Resumo: Brånemark et al. (1969) introduziram os implantes osseointegrados como forma de ancoragem para próteses com intuito de substituir os dentes perdidos, tanto na mandíbula como na maxila. Desde então, foram instituídas modificações no protocolo clássico. Entre elas, a submissão dos implantes à função imediatamente após a sua instalação. Esse procedimento tem sido largamente estudado na mandíbula, com altos índices de sucesso, contudo, a literatura é escassa quanto à aplicação desta técnica na maxila. Propôs-se, então, avaliar a função imediata em implantes instalados em maxilas desdentadas totais, no momento da cirurgia e após seis e 12 meses de função. Para tanto foi utilizada uma técnica cirúrgica modificada e a avaliação da estabilidade dos implantes foi feita por meio da análise da freqüência de ressonância. Foram selecionados 10 pacientes, nos quais foram instalados seis implantes na maxila com a submissão dos mesmos à função imediata mediante a instalação de uma prótese fixa, com infra-estrutura metálica, 24 horas após a cirurgia. Estes pacientes foram acompanhados por um período de 12 meses. As medidas da estabilidade do implante foram realizadas no momento da instalação dos implantes (M0) e após seis (M6) e 12 meses (M12). Após o período de acompanhamento, foram obtidos índices de sucesso de 95% para os implantes e 90% para as próteses. Quanto aos valores da estabilidade dos implantes, foi observada uma diferença estatisticamente significativa entre os valores de M0 e M6, e, M0 e M12. Sendo o M0, o momento com maior valor do coeficiente de estabilidade. Não houve diferença estatisticamente significativa entre os valores da estabilidade obtidos no M6 e M12. Quando comparados, o valor da estabilidade para cada implante, não apresentaram diferença estatisticamente significativa no mesmo período de avaliação...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brånemark et al. (1969) presented the osseointegrated implants as a way to anchorage prosthesis for missing teeth substitution in the jaws. Ever since, modifications in the classical protocol were instituted. Among them, the functional loading of the implants, immediately after their installation. This procedure have been well documented in mandibles, with high success levels, however, literature is scarce about the application of this technique in maxilla. The purpose of this study is to evaluate the immediate function in implants installed in totally edentulous maxillas, at the surgical moment and after six and 12 months of function. For so much, a modified surgical technique was used and implant stability was evaluated through the resonance frequency analysis. Ten patients were selected, who received six implants installed in the maxilla and submitted to immediate function. A metallic infra-structure fixed prosthesis was installed 24 hours after the surgery. The follow-up period was of 12 months. Implant stability measurements were taken at the surgical moment (M0) and after six (M6) and 12 months (M12). After the follow-up period, success rates of 95% for implants and 90% for prosthesis were achieved. As for the implant stability values, significant statistical difference were observed between M0 and M6, and M0 e M12, and no significant statistical difference was observed between M6 and M12. When the stability values of each implant was compared, no significant statistical difference was observed between them for different evaluation periods. It is concluded that the submission of implants, installed in the maxilla through a modified technique, to immediate function is a well predictable procedure, ever since well selected and executed. The resonance frequency analysis is an efficient method for the evaluation of the initial and late implants' stability. / Doutor
5

Estudo das dimensões da papila gengival em áreas ântero superiores adjacentes a implantes unitários /

Perez, Fabiano. January 2006 (has links)
Resumo: O objetivo deste trabalho foi o de comparar as dimensões da papila gengival em áreas restauradas com implantes unitários e áreas com a dentição natural hígida. Além disso, verificou-se a influência da distância da crista óssea até o ponto de contato e da distância da plataforma do implante até a parede axial do dente adjacente sobre a extensão da papila gengival. Para isso, foram selecionados um total de 45 áreas proximais entre dentes naturais e 46 áreas proximais com a presença de implantes unitários. Os pacientes eram, então, submetidos a um exame clínico que tinha por objetivo a constatação da presença total, parcial, ou a ausência da papila gengival nas áreas examinadas. A papila gengival era então classificada em 4 níveis de altura: 0, quando estava totalmente ausente; 1 quando a papila ocupava menos da metade da distância da sua base até o ponto de contato; 2 quando a papila ocupava mais da metade dessa mesma distância, porém não preenchia totalmente o espaço interproximal; e 3 quando todo o espaço interproximal era ocupado pela papila gengival. Depois do exame clínico, os pacientes eram submetidos a tomadas radiográficas sendo que uma tela milimetrada era adaptada junto ao filme para que a imagem radiográfica obtida pudesse ser mensurada mais satisfatoriamente. Depois de obtidas as radiografias, as radiografias foram digitalizadas e as distâncias referentes ao estudo foram feitas por meio de um programa de computador. Com a análise dos dados obtidos, permitiu-se concluir que áreas anteriores superiores restauradas com implantes tendem a apresentar uma papila gengival com menor dimensão do que áreas de dentição natural. / Abstract: The purpose of this work was to compare the interproximal dental papilla dimension in areas restored with single implants and in areas of natural dentition. The effect of the distance from the contact point to the bone crest and of the distance from the implant platform to the axial face of the adjacent tooth on the papilla extension was also evaluated. Forty five interdental areas and 46 inter-implant areas were selected for the study. The presence (total or partial) or the absence of the interproximal papilla were examined and the following punctuations were made: 0 when the papilla was completely absence; 1 when the papilla filled less then half of the distance between its base and the contact point; 2 when the papilla filled more then half of that distance but not filled the entire of the interdental space; 3 when the whole interdental space was filled by the papilla. After the clinical examination, the patients were submitted to radiographic exams, using a radiographic grid adapted to the film to improve the measurements. The radiographs images were then digitized and the distances related to the study were measured using a computer software. From the data obtained, it was concluded that maxillary anterior areas restored with implants tend to present a smaller interdental papilla then areas of natural dentition. The distance from the contact point to the bone crest (height), the distance between adjacent roots in the natural dentition and the distance between the implant platform and the adjacent root (width) had significant influence on the presence or absence of the interproximal papilla in both groups evaluated. / Orientador: José Cláudio Martins Segalla / Coorientador: Elcio Marcantonio Junior / Banca: Paulo Martins Ferreira / Banca: José Mondelli / Banca: Regina Helena Barbosa T. da Silva / Banca: Francisco de Assis Mollo Junior / Doutor
6

Análise de corrosão e fratura de implantes/componentes protéticos de titânio comercialmente puro, após serem submetidos a ciclos de fadiga em um meio fluoretado com diferentes Ph /

Sartori, Rafael. January 2006 (has links)
Resumo: Atualmente o titânio é empregado como biomaterial devido sua biocompatibilidade e resistência à corrosão, entretanto os íons fluoretos são efetivos no processo de corrosão. O objetivo deste estudo foi analisar a influência de um meio fluoretado com diferentes pH nas propriedades mecânicas e na resistência à corrosão dos conjuntos implantes/componentes protéticos à base de Ti c.p., a partir dos testes de ciclagem mecânica, microscopia eletrônica de varredura (MEV) e dureza. Foram simulados cinco anos de uso regular de meios de higiene oral com conteúdo de 1500 ppm de NaF, com dois diferentes pH, mediante imersão das amostras nesse meio durante 184 horas. As amostras foram testadas num durômetro Micromet 2001. Os dados dos testes de dureza foram analisados pelo teste de Wilcoxon, demonstrando que as amostras sofreram influência negativa na dureza após a ação dos íons fluoreto. Entretanto, essa influência não ocorreu nos testes de ciclagem mecânica realizados em uma máquina de ensaios universais MTS-810, fixada a 100.000 ciclos, 15Hz e programada com força de fadiga a 150 N. Pela análise de MEV e EDS não foi contatado evidências de corrosão na superfície das amostras após ação de íons fluoretos, nem incorporação de íons fluoretos sobre a superfície dos conjuntos. Concluiu-se que a concentração de flúor e o pH das soluções não exerceram influência nas propriedades mecânicas e na resistência à corrosão. / Abstract: Titanium has been widely used as biomaterial owing to its excellent corrosion resistance, mechanical properties and biocompatibility. However, it has been reported that fluoride-containing environments can attack titanium. The aim of this study was evaluated fluoride environments influence with different pH values in the implant/abutment sets. The implants were separated into 3 groups containing 7 implants/brand: one was submerged in acid fluoride environment (NaF 1500ppm 184h pH 5.3), one in neutral fluoride environment (NaF 1500ppm 184h pH 7.4), and other group in distillated water, simulating five years of dental hygiene. Hardness and surface texture were evaluated before and after fluoride exposition by Vickers method (500gf 30s) and scanning electron microscopy (SEM), respectively. The fatigue test was performed with 100.000 load cycles, 15 Hz and 150 N. There was decrease in hardness in implants submitted to the fluoride environment. SEM and EDS evaluation showed dark stains in all implants, irrespective of fluoride pH, resulting from pitting corrosion process. All sets supported the fatigue test until 100.000 load cycles. The results demonstrated that fluoride environment there was no influence in mechanical properties and corrosion resistence of the implant/abutment sets. / Orientador: Luis Geraldo Vaz / Coorientador: Elcio Marcantonio Junior / Banca: Valfrido Antonio Pereira Filho / Banca: Gibson Luiz Pilatti / Mestre
7

Estudo da precisão da análise de tomografias espirais de mandíbulas humanas secas realizadas pelo tomógrafo X-Mind Tome /

Munhoz, Felipe Camargo. January 2008 (has links)
Orientador: Gilberto Aparecido Coclete / Banca: Alvimar Lima de Castro / Banca: Cleverson Luciano Trento / Resumo: O sucesso dos implantes dentários depende de um cuidadoso planejamento préoperatório. O exame radiográfico é de fundamental importância na avaliação da morfologia, inclinação óssea e localização de estruturas anatômicas críticas durante os procedimentos de implantação, quando é necessário medir a quantidade de osso disponível. A Tomografia convencional é um exame de extrema importância, pois permite a mensuração da altura e espessura do rebordo alveolar, determinantes na escolha do tamanho do implante. Poucos autores estudaram a influência da variação do movimento tomográfico na qualidade da imagem. O objetivo deste trabalho foi elucidar precisamente as áreas avaliadas pelas imagens fornecidas por tomografias realizadas pelo tomógrafo espiral X-MIND TOME, fabricado em 2005 pela SOREDEX, Helsink, Finlândia. Foram utilizadas dez mandíbulas humanas secas, desdentadas na região dos pré-molares e molares. Os implantes foram posicionados bilateralmente em oito mandíbulas e unilateralmente em duas, com a distância de 4 mm um do outro. Em seguida, cada mandíbula foi adaptada ao tomógrafo, onde foi realizada uma radiografia panorâmica prévia, com magnificação de 50%. Sobre esta radiografia foi colocado um template que determina a região a ser avaliada, sendo realizados cortes de 4mm de largura, nos dois lados da mandíbula. Comparou-se então a solicitação ao tomógrafo com os resultados obtidos, quanto à distância e a ordem dos cortes solicitados. Foram realizadas 19 tomografias que foram avaliadas utilizando-se o programa Radioimp RADIO MEMORY - Belo Horizonte - Brasil. Em seguida, os dados foram tabulados, analisados e estudados estatisticamente, com nível de significância 5%. Através do teste de Wilcoxon, não foram evidenciadas diferenças estatisticamente significantes nos dados obtidos pelas tomografias, sendo, portanto, precisas. / Abstract: The success of dental implants depends on a carefull pre-opertative planning. The radiographic exam is of main importance for a correct evaluation of morphology, bone inclination and location of critical anatomical structures during the surgical procedures for dental implants, when it's necessary to measure the amount of available bone. The conventional Tomography is a very important exam, because it allows the measurement of height and thickness of the alveolar bone for the determination of the implant's size. Few authors studied the influence of the tomographic movement variation in the quality of the image. The aim of the present paper is to clarify the precision of the areas evaluated by the images given by the spiral scanning X-MIND TOME, made in 2005 by SOREDEX, Helsink, Finland. There were used 10 dried mandibles, toothless in the region of pre-molars and molars. The implants were placed in both sides in eight mandibles and in one side in two, with the distance of 4mm one from another. After this, each mandible was placed in the scanning, where a previous panoramic radiograph was taken, with magnification of 50%. Upon this radiograph, it was placed a template to determine the region to be evaluated, where there were made cuts of 4mm of width, in both sides of the mandible. The scanning request was then compared to the obtained results. It was made 19 radiographs that were evaluated using the Radioimp program (RADIO MEMORY - Belo Horizonte - Brazil). The data were then analyzed and studied statistically, with significance of 5%. Throught wilcoxon test, there were not noticed statistical differences in the data obtained in the tomographies, that showed to be precise. / Mestre
8

Estudo da influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos /

Oliveira, Sérgio Ricardo de. January 2008 (has links)
Orientador: Valdir Gouveia Garcia / Banca: Maria José Hitomi Nagata / Banca: Álvaro Francisco Bosco / Banca: Ariel Lenharo / Banca: Jamil Awad Shibli / Resumo: As modalidades terapêuticas que envolvem implantes dentais têm se expandido gradativamente, sendo implantados em uma variedade de estruturas ósseas. Dessa forma, o propósito do presente trabalho foi estudar a influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos. Foram utilizados implantes de titânio c.p., grau II, cônico de 1,4mm de diâmetro e 2,7mm de comprimento, com superfície tratada. Trinta e oito ratos wistar tiveram seus primeiros molares superiores esquerdo e direito extraídos. Após 30 dias de reparo alveolar, dois animais foram sacrificados para confirmar o fim desse processo. Os demais animais tiveram os implantes instalados bilateralmente e foram divididos randomicamente em três grupos: Controle (Ctr/n=12) que não receberam nenhum tipo de tratamento; Placebo (Pl/n=12) e Tratado (Tra/n=12), que receberam injeções diárias de 1 ml de solução salina e corticosterona na dosagem de 5mg/kg, respectivamente. Trinta dias após a implantação, todos os animais foram eutanasiados e tiveram a concentração plasmática do corticóide mensurada: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) e Tra (281,37 ± 64,72 ng/ml); e o contato osso-implante determinado: Ctr (96,67%), Pla (82,22%) e Tra (15,73%), nos quais o grupo Tra apresentou-se estatisticamente diferente dos demais grupos (p<0,05). Assim, diante da metodologia empregada, foram evidenciadas menor formação óssea e conseqüente redução da área de tecido ósseo neo-formado na interface osso-implante. / Abstract: The therapeutic modalities which involves dental implants has been gradually expanded, being implanted in a variety of bone structures. In this way, the aim of the present work was to study the corticoid influence at the initial process of bone integration of titanium implants installed in rat jaws. It were used titanium implants c.p.; grade II, conic with 1,4mm diameter and 2,7mm length, with treated surface. Thirty eight wistar rats had their first upper left and right molars extracted. After 30 days of alveolar repair, two animals were sacrificed to confirm the end of this process. The others had their implants installed bilaterally and they were splited randomly in three groups: Control (Ctr/n=12) which did not receive any kind of treatment; Placebo (Pla/n=12) and Treated (Tre/n=12) which received 1ml daily shots of salt solution and corticosterone at a dosage of 5mg/Kg, respectively. Thirty days after the implantation, all the animals were euthanasiated and the plasmatic concentration of corticoid was measured: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) and Tre (281,37 ± 64,72 ng/ml); and the bone implant contact was determined: Ctr (96,67%), Pla (82,22%) and Tre (15,73%), in which the Tre group presented statistically different from the other groups (p<0,05). Thus, front the employed methodology it was shown lesser bone formation and consequent reduction of the bone tissue area neo-formed at bone-implant interface. / Doutor
9

Efeito da altura da união implante/componente protético sobre os tecidos periimplantares : estudo clínico e radiográfico em cães /

Paula, Wagner Nunes de. January 2008 (has links)
Resumo: O objetivo deste estudo foi avaliar as alterações dos tecidos periimplantares, ao redor de implantes instalados em diferentes profundidades em relação à crista óssea, e sob protocolos de reabilitação protética convencional e imediato. Cinco cães receberam trinta implantes, três por hemi-mandíbula (seis por cão), na região dos quatro pré-molares inferiores que foram extraídos 90 dias antes. Cada região foi divida pelos subgrupos convencional (protocolo convencional, instalação da prótese 120 dias após os implantes) e imediato (protocolo imediato, instalação da prótese 1 dia após a cirúrgia de implantes). Os implantes foram inseridos em três profundidades diferentes: ao nível (ao nível do rebordo ósseo), -1 mm (1 mm apicalmente à crista óssea) e -2 mm (2 mm apicalmente à crista óssea). Após acompanhamento por 45 dias da reabilitação instalada foi realizada avaliação clínica e radiográfica e, os dados foram analisados estatisticamente (p< 0.05). A posição do tecido marginal (PTM) não foi alterada pelo protocolo de instalação, e sim pelo nível de inserção da junção implante-conector protético (JIC) em relação a crista óssea (BC). A reabsorção da BC em função do nível de inserção de JIC foi relativamente uniforme para os diferentes grupos. Estes achados sugerem cautela ao posicionar a JIC de implantes apicalmente à BC. / Abstract: The aim of the present study was to evaluate changes in tissues around dental implants inserted in different levels in relation to crestal bone (BC) under early and delayed loading conditions. Thirty implants were inserted in five mongrel dogs were used in this study, from which, the lower premolars were removed, and 90 days after, in one side, three dental implants were inserted (Delayed subgroup, implants installed 120 days before loading) in three different levels in relation to crestal bone (Bone Level, Minus1 and Minus2 groups), and three implants were inserted on remain ridge (Early subgroup, implants were loaded 48 hours after installed). The metallic prostheses were installed in both sides and preserved for 45 days. The clinical and radiographic analyses were performed. Data was submitted to statistics, under a 5% level of significance. The load conditions did not interfered on the position of marginal soft tissues (PTM), those changes evaluated because of the insert level of the implant-abutment junction (JIC) in to BC. The BC resorption was similar in all types of insertion levels of the implants. The present finds suggest caution on insertion of the implant in an apical position level in relation to BC. / Orientador: Elcio Marcantonio / Coorientador: Elcio Marcantonio Junior / Banca: Walter Martins Junior / Banca: Luis Antonio Borelli Barros / Mestre
10

Avaliação da formação óssea em implantes dentários de ratos não diabéticos, diabéticos não controlados e controlados com insulina /

Souza, Augusto César Rodrigues de. January 2011 (has links)
Resumo: O diabetes mellitus é considerado hoje, um problema de saúde pública mundial. Na odontologia está associado à doença periodontal, aumentando as chances de perda do elemento dental nos pacientes diabéticos. Implantes dentários são cada vez mais utilizados em pacientes parcialmente ou totalmente edêntulos para reposição dessas perdas. Estudos experimentais, para viabilizar o tratamento dentário de diabéticos através de implantes são cada vez mais freqüentes. Dada a relevância do tema, ainda existem lacunas no estudo da osseointegração de implantes em animais diabéticos. Por isso, visando dar sequência a esses estudos experimentais já existentes, esse estudo foi delineado para avaliação da osseointegração de implantes dentários em animais normais, diabéticos e diabéticos tratados com insulina, utilizando parâmetros adicionais nunca antes avaliados. O presente estudo teve como objetivo avaliar a formação óssea ao redor de implantes dentários em ratos diabéticos aloxânicos controlados com insulina, em relação a ratos não diabéticos e diabéticos não controlados. Foram avaliados 72 ratos da raça Wistar, machos, sadios ao exame clínico, pesando entre 200 e 300g, distribuídos em três grupos experimentais de 24 animais cada, sendo um grupo controle normal (GC), um grupo diabético sem tratamento (GD) e um grupo diabético tratado com insulina (GI). Os animais receberam os implantes dentários no fêmur direito e foram avaliados em três momentos pós-operatórios (7º, 14º e 21ºdias), onde foram analisadas a evolução clínica (peso corporal e diurese), exames laboratoriais (glicemia de jejum, hemoglobina glicosilada e insulina sérica). Em cada um dos momentos mencionados os animais foram sacrificados e retirado o fêmur com o implante, sendo espécimes de 4 animais utilizados para análise ultraestrutural das fibras colágenas, à microscopia... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Diabetes mellitus is nowadays a public health problem worldwide. In dentistry is associated with periodontal disease, increasing the possibilities of tooth loss in diabetic patients. Dental implants are been commonly used in patients partially or completely edentulous to replace these losses. Experimental studies, to enable the dental treatment of diabetics through implants are becoming more frequent. Despite the relevance of the issue , there are still gaps in the study of osseointegration of implants in diabetic animals . Therefore, in order to fulfill some of these questions, this study was designed to evaluate the osseointegration of dental implants in normal, diabetic and diabetic treated with insulin animals, using additional parameters never studied before. This study aimed to evaluate bone formation around dental implants in alloxan diabetic rats without treatment, controlled with insulin, and non diabetic rats. Materials and Methods: 72 Wistar rats, male, healthy at clinical examination, weighing between 200 and 300g were divided into three experimental groups of 24 animals each, a normal control group (CG), an untreated diabetic group (DG) and a diabetic group treated with insulin (IG). The animals received dental implants in the right femur and were assessed at three post-operative moments (7, 14 and 21 days), which analyzed clinical (body weight and diuresis) and laboratorial parameters (fasting glucose, hemoglobin glycosylated and serum insulin). In each of the mentioned moments the animals were sacrificed and the femur with the implant was removed, and four specimens of animals used for ultrastructural analysis on scanning electron microscopy, and another 4 to hystopathological examination by light microscopy method HE staining. Induction of diabetes was made by intravenous injection of alloxan 2% in a single dose of 42mg/kg. Were included in the experiment only animals... (Complete abstract click electronic access below) / Orientador: Erika Veruska Paiva Ortolan / Coorientador: Carlos dos Reis Pereira de Araújo / Banca: César Tadeu Spadella / Banca: César Augusto Magalhães Benfatti / Mestre

Page generated in 0.0994 seconds