Avaliação das alterações dos tecidos ao redor de implantes inseridos em diferentes níveis em relação à crista óssea : estudo clínico, radiográfico, e histométrico em cães /

Pontes, Ana Emilia Farias. January 2007 (has links)
Resumo: O objetivo do presente estudo foi avaliar alterações ao redor de implantes inseridos em diferentes níveis em relação à crista óssea, e sob diferentes protocolos de restauração. Trinta e seis implantes foram inseridos nas mandíbulas edêntulas de 6 cães. Três implantes foram instalados por hemi-mandíbula, cada qual representativo de um grupo experimental. Estes foram determinados de acordo com a distância entre a junção implante-conector protético (JIC) e a crista óssea: Ao Nível (ao nível da crista óssea), Menos 1 (1mm apical à crista óssea), ou Menos 2 (2mm apical à crista óssea). Cada hemi-mandíbula foi submetida a um protocolo de restauração: convencional (prótese instalada 120 dias após a implantação) ou imediata (prótese instalada 24 horas após a implantação). Parâmetros clínicos, radiográficos, e histométricos foram avaliados após 90 dias de restauração, e os dados foram analisados estatisticamente (alfa=5%). A posição da margem do tecido mole (PTM) não foi influenciada pelo posicionamento apical da JIC; entretanto, sítios submetidos à restauração imediata tiveram a PTM significantemente mais coronal que os submetidos à restauração convencional (p=0,02, análise clínica). A reabsorção do rebordo não foi estatisticamente diferente entre os grupos (p>0,05, análise radiográfica). Menores quantidades de Perda Óssea Lateral (POL) foram observadas nos sítios restaurados imediatamente em comparação com os restaurados convencionamente (p=0,006, análise histométrica). Os presentes achados sugerem que o posicionamento apical da JIC não põe em risco a altura de tecidos periimplantares moles ou duros. Além disto, a restauração imediata foi benéfica para manter a PTM, e minimizar a POL. / Abstract: The aim of the present study was to evaluate changes that occur around dental implants inserted in different levels in relation to crestal bone, under different restoration conditions. Thirty-six implants were inserted in the edentulous mandible of six dogs. Three implants were inserted per hemimandible, each one representing an experimental group according to the distance from the implant-abutment junction (IAJ) to the crestal bone: Bone Level (at crestal bone level), Minus 1 (1mm below crestal bone), or Minus 2 group (2mm below crestal bone). Each hemimandible was submitted to a restoration protocol: conventional (prothesis installed 120 days after implant placement) or immediate (prosthesis installed 24 hours after implant placement). Clinical, radiographic, and histometric parameters were evaluated after 90 days of restoration, and data was analyzed statistically (alpha=5%). The position of soft tissue margin (PSTM) was not influenced by the apical positioning of the IAJ; however, sites submitted to immediate restoration had the PSTM displayed significantly more coronally than those submitted to conventional restoration (p=0.02, clinical analysis). Ridge Loss was not statistically different among groups (p>0.05, radiographic analysis). Greater amounts of Lateral Bone Loss (LBL) were observed for conventionally than for immediately restored sites (p=0.006, histometric analysis). These findings suggest that the apical positioning of IAJ did not jeopardize the height of peri-implantar soft and hard tissues. Moreover, immediate restoration was beneficial to maintain the PSTM, and to minimize LBL. / Orientador: Elcio Marcantonio Junior / Coorientador: Joni Augusto Cirelli / Banca: Roberto Henrique Barbeiro / Banca: Marcio Fernando de Moraes Grisi / Banca: Mário Taba Junior / Banca: Sérgio Luís da Silva Pereira / Doutor
12

Influência do diâmetro, comprimento e angulação nos torques de inserção e remoção de mini-implantes autoperfurantes /

Pignatta, Lilian Maria Brisque. January 2011 (has links)
Orientador: Eduardo César Almada Santos / Coorientador: Francisco Antonio Bertoz / Banca: Marcos Rogério de Mendonça / Banca: Paulo Henrique dos Santos / Banca: Maurício Tatsuei Sakima / Banca: Júlio de Araújo Gurgel / Resumo: Objetivo: avaliar a influência da associação do diâmetro, comprimento e angulação do mini-implante sobre a estabilidade primária a partir da análise do torque de inserção e remoção. Material e método: foram instalados 120 mini-implantes autoperfurantes, cilíndricos, com 1,4 x 6mm, 1,4 x 8mm, 1,6 x 6mm e 1,6 x 8mm, em um bloco de osso artificial. Os mini-implantes foram instalados com o auxílio da chave de mão acoplada ao torquímetro digital, possibilitando a inserção e mensuração do torque com orientação perpendicular e com inclinação de 60° em relação à superfície do bloco de osso artificial. Os mini-implantes foram removidos da mesma forma como inseridos, porém girando-se a chave em sentido anti-horário. Os registros foram realizados através da conexão do torquímetro ao computador e os valores do torque de inserção e remoção foram obtidos pelos picos máximos dos gráficos, registrados pelo software Datalogger e compilados em tabelas. Realizou-se a análise descritiva para obter a média e desvio-padrão de cada grupo, e submeteram-se os resultados à análise de variância (ANOVA). Resultados: a média dos torques variou entre 19,2 a 23,6Ncm nos testes de inserção e entre 11 a 14,66Ncm nos testes de remoção. Conclusões: as variáveis diâmetro e comprimento não exerceram influência significativa nos valores dos torques de inserção e remoção. A angulação de instalação ocasionou aumento significativo desses torques no grupo 7. Os demais grupos, porém, não apresentaram diferença significante entre as angulações / Abstract: Objective: evaluate the influence of diameter, length and angulation of mini-implant on the primary stability through the analysis of insertion and removal torque. Material and Methods: were installed 120 self-drilling mini-implants, cylindrical, with 1.4 x 6mm, 1.4 x 8mm, 1.6 x 6mm and 1.6 x 8mm in a block of artificial bone. The screwdriver for mini-implants was connected to digital torquimeter, in order to allow the insertion and measurement of torque oriented perpendicular and slanting at 60° to the bone surface. Mini-implants were removed the using the same procedures, but turning the screw driver counterclockwise. The recordings were made by connecting the torquimeter to the computer and values of insertion and removal torque were obtained by the maximum peak of the graphics, collected by the Datalogger software and compiled into tables. We conducted a descriptive analysis for the mean and standard deviation of each group, and the results submitted to analysis of variance (ANOVA). Results: the mean torques ranged from 19.2 to 23.6Ncm for insertion tests and between 11 to 14.66Ncm for removal tests. Conclusions: the diameter and length did not influence significantly the values of insertion and removal torques. The angle of installation of these torques caused a significant increase in group 7. However, the other groups showed no significant difference between the angles / Doutor
13

Análise comparativa de técnicas de moldagem para próteses implantossuportadas /

Amaral, Ângela Líbia Chagas January 2009 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: Proposta: A proposta deste estudo in vitro foi avaliar 3 técnicas de moldagem (Cônico, Hélice e Unido com barra) para próteses implantossuportadas. Materiais e métodos: Um modelo mandibular em latão contendo 4 análogos de implantes e uma estrutura metálica foram confeccionados. Foram utilizados 2 materiais de moldagem: Silicona de polimerização por adição (Express STD, 3M ESPE) e Silicona de polimerização por condensação (Zetaplus/Oranwash, Zermack). Seis grupos foram formados pela combinação entre cada material e técnica de moldagem. Um total de 30 modelos foram fabricados (5 modelos por grupo) e 120 valores de fendas foram analisados (1 valor de fenda para cada análogo de implante). Resultados: Para o material Express, os valores médios de fenda foram: 164,40 μm (Cônico), 97,90 μm (Hélice) e 127,79 μm (Unido). Para o material Zetaplus/Oranwash, os valores médios de fenda foram: 219,37 μm (Cônico), 118,57 μm (Hélice) e 78,50 μm (Unido). Houve uma diferença estatística significante entre o Cônico e a Hélice para o material Express (p<.05). Quando o material avaliado foi o Zetaplus/Oranwash, todos os grupos foram diferentes estatisticamente entre si (p<.05). Conclusões: Os melhores resultados foram alcançados para a Hélice e para Unido quando o material avaliado foi o Express. Para o Zetaplus/Oranwash, a melhor técnica foi o Unido, seguida da Hélice e do Cônico. / Abstract: Purpose: The purpose of this in vitro study was to evaluate 3 impression techniques (tapered impression copings, squared modified impression copings, and squared impression copings splinted with bur and acrylic resin) for implant-supported prosthesis. Materials and Methods: A mandibular brass cast with 4 stainless steel implant-abutments analogs and a framework were fabricated. Addition silicone - Express - and condensation silicone - Zetaplus/Oranwash - impression materials were tested. Six groups were formed by combining each material and impression technique. Five casts were made per group for a total of 30 casts and 120 gap values (1 gap value for each implant-abutment analog). Results: With the Express impression material, the mean gap values were 164.40 μm for the tapered group, 97.90 μm for squared modified group and 127.79 μm for squared splinted group. With the Zetaplus/Oranwash impression materials, the mean gap values were 219.37 μm for the tapered group, 118.57 μm for squared modified group and 78.50 μm for squared splinted group. There was significantly difference between tapered impression technique and squared modified impression technique (P<.05), when the material was Express. When the material was the condensation silicone, all groups had significantly difference among themselves (P<.05). Conclusions: The best results were achieved for squared modified impression technique and squared splinted impression techniques, when the impression material was Express. For condensation silicone, the best technique was squared splinted group, followed by squared modified group, and tapered group. / Mestre
14

Reparo ósseo em defeito peri-implantar com e sem associação de enxerto ósseo autógeno obtido por Piezocirurgia : estudo experimental em coelhos /

Homsi, Nicolas. January 2011 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Élio Hitoshi Shinohara / Banca: Thallita Pereira Queiroz / Banca: Jéssica Lemos Gulinelli / Banca: Martha Alayde Alcantara Salim / Resumo: Proposição: A proposta deste estudo foi avaliar por análise histométrica a resposta tecidual óssea de enxerto autógeno coletado por piezocirurgia para o preenchimento de defeitos nas porções cervicais de implantes instalados em tíbias de coelhos. Métodos: Foram instalados 26 implantes em 13 tíbias de coelho, após a estabilidade inicial foram realizados defeitos cervicais por trefinagem, em um grupo foi mantido apenas o coágulo como preenchimento e em outro grupo o defeito foi preenchido por osso autógeno coletado por equipamento piezoelétrico, os animais foram sacrificados após 15 e 30 dias, a análise histométrica das interfaces implante-osso foram realizadas pelo software Image Lab. Resultados: Foi analisado o percentual de extensão linear de contato entre tecido ósseo e implante, a média percentual obtida de contato entre tecido ósseo neoformado e implante foram estabelecidas como médias da área de osso neoformado entre as espiras e contato osso-implante (BIC). Os resultados obtidos foram: no controle de 15 dias, o percentual entre as espiras foi de 65,2% e entre as espiras e contato osso-implante (BIC) de 88,7%. No controle de 30 dias o contato entre as espiras foi na ordem de 65,2% e entre as espiras e contato osso-implante (BIC) de 73,2%. No grupo de enxerto de 15 dias, o osso formado entre as espiras foi de 69,3% e entre as espiras e contato osso-implante (BIC) em 81%, no grupo enxerto 30 dias o osso formado entre as espiras foi de 91,47% e entre as espiras e contato ossoimplante (BIC) 91,56%. Conclusão: o enxerto ósseo autógeno particulado obtido por piezocirurgia apresenta melhor resultado que o coágulo sanguíneo no osso neoformado entre as espiras e no contato osso-implante / Abstract: Purpose: The purpose of this study was to evaluate by histometric analysis the outcome of autogenous bone collected through piezo surgery equipment in filling cervical portion defects around implants placed in rabbits tibias. Materials and Methods: Twenty-six implants were installed in 13 rabbits tibias, after initial primary stability, cervical defects were carried out by the use of a trephina, in one group the cloth was maintained as the defect filling and in another group the defect was filled by autogenous bone collected through piezo surgery equipment, the animals were sacrificed after 15 and 30 days, the histometric analysis of the implant-bone interfaces were carried out by the use of Image Lab software. Results: The lineal stretch percentage of contact between bone and implant was analyzed, the average percentage obtained in the contact between the newly formed bone and the implant was established as the average area of the newly formed bone in the space between the spires and the bone-implant contact (BIC). The results obtained were: in the 15-days control group, the percentage of bone formation between the spires was of 65.2% and between the spires and boneimplant contact (BIC) was of 88.7%. In the 30-days control group the contact between the spires was of 65.2% and between the spires and bone-implant contact (BIC) of 73.2%. In the 15-days control grafted group, the formed bone between the spires was of 69.3% and between the spires and bone-implant contact (BIC) of 81%, in the 30-days control grafted group, the formed bone between the spires was of 91.47% and between the spires and bone-implant contact (BIC) of 91.56%. Conclusions: the autogenous bone collected through piezo surgery equipment showed better results than the blood clot regarding the newly formed bone between the spires and bone-implant contact (BIC) / Doutor
15

Análise das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexões e qualidade óssea : estudo pelo método dos elementos finitos tridimensionais /

Antenucci, Rosse Mary Falcón. January 2011 (has links)
Orientador: Eduardo Piza Pellizzer / Coorientador: Pedro Yoshito Noritomi / Banca: Paulo Sérgio Perri de Carvalho / Banca: Fellippo Ramos Verri / Banca: Marcelo Ferraz Mesquita / Banca: Pedro Tortamano Neto / Resumo: Um aspecto crítico que afeta o sucesso ou falha de um implante é a maneira pela qual as tensões são transferidas do implante ao tecido ósseo. A sobrecarga na prótese dentária pode levar a perda da osseointegração, dessa forma, é aconselhável evitar altas concentrações de tensões no osso de suporte, do ponto de vista clínico. Entretanto, o estresse mecânico pode ter consequências positivas ou negativas no tecido ósseo, fatores esses dependentes de vários fatores associados que podem ser mecânicos ou biológicos. Portanto, o propósito do presente estudo foi analisar a influência da qualidade óssea na distribuição das tensões em próteses unitárias implantossuportadas com diferentes tipos de conexão protética, pelo método dos elementos finitos tridimensionais. Para isso, foram confeccionados doze modelos tridimensionais com o auxílio dos programas de modelagem gráfica SolidWorks 2010 e Rhinoceros 4.0, além do programa InVesalius. Cada modelo foi composto por um bloco com diferentes qualidades ósseas (Tipo I, II, III e IV) e a presença de um implante (4,0x10 mm) com diferente tipo de conexão (Hexágono externo, interno e cone Morse), com coroa metalo-cerâmica. Após geração de geometrias, os modelos foram importados para o programa de pré e pós processamento de elementos finitos FEMAP 10.2, onde foram geradas as malhas de elementos finitos, condições de carregamento e contorno. A carga aplicada foi de 200N axialmente e 100N obliquamente, na superfície oclusal das coroas. Essa carga total foi dividida entre as cúspides (4 para a carga axial e as duas linguais para a carga oblíqua). Em seguida, a análise foi gerada no programa FEMAP 10.2 e exportada para cálculo no programa de elementos finitos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: A critical issue that affects the success or failure of an implant is the manner in which the stresses are transferred from the implant to bone tissue. The overload can lead the dental implant to loss of osseointegration, thus it is advisable to avoid high stress concentrations in bone support, according to the clinical point of view. However, mechanical stress can bring positive or negative consequences in the bone tissue and these factors depend on association with mechanical or biological factors. Therefore, the purpose of this study was to analyze the influence of bone quality on stress distribution in implant-prosthesis unit with different types of prosthetic connection, by the three-dimensional finite element method. For this, twelve three-dimensional models were made with the aid of SolidWorks 2010 and Rhinoceros 4.0, graphical modeling software, besides the InVesalius. Each model was composed of a block with different bone qualities (Type I, II, III and IV), an implant (4.0 x 10 mm) with different type of prosthetic connection (Hexagon external, internal and Morse taper) and metal ceramic crown. After generation of geometries, the models were imported into FEMAP 10.2, the pre and post-processing finite element software, where it was generated finite element meshes, boundary and loading conditions. The 200N load was applied axially and 100N obliquely on the occlusal surface of crowns. This total load was divided among the cusps (four points for the axial load and two points for the oblique load on the lingual cusps). Then, the analysis was generated in the FEMAP 10.2 and exported to the NeiNastran version 9.2 software for calculation in finite element analysis, running on a workstation. The results were imported back to the FEMAP 10.2 for viewing and post-processing maps of von Mises stress and... (Complete abstract click electronic access below) / Doutor
16

Corrosão e tribocorrosão de novas ligas Ti35Nb5Zr e Ti35Nb10Zr em saliva artificial /

Ribeiro, Ana Lúcia Roselino. January 2012 (has links)
Resumo: O sucesso dos implantes dentários em longo período depende da interação do biomaterial com o ambiente bucal, a qual envolve reações eletroquímicas, resistência mecânica e desgaste mecânico. Com o intuito de melhorar a resistência mecânica e à corrosão do titânio (Ti), elementos de liga são adicionados, sendo a liga Ti6Al4V a mais comum. Porém, o vanádio e o alumínio são considerados potencialmente tóxicos. Portanto, nos últimos anos, esforços vêm sendo feitos para o desenvolvimento de novas ligas de Ti ultra resistentes e biocompatíveis, a partir do sistema TiNbZr. Assim, o objetivo desse trabalho foi avaliar a corrosão e tribocorrosão das novas ligas Ti35Nb5Zr e Ti35Nb10Zr em saliva artificial a 37°C comparadas à liga comercial Ti6Al4V. Testes de potencial de circuito aberto com o tempo (Ecorr) e espectroscopia de impedância eletroquímica (EIS) foram realizados em função do tempo (0-216h). Testes de tribocorrosão em função de cargas aplicadas (50mN-1N) foram realizados tanto em Ecorr como em potencial anódico aplicado. Como resultados, todas as ligas exibiram aumento de Ecorr com o tempo, indicando crescimento e estabilização do filme passivo. Os experimentos de EIS indicaram que a liga Ti35Nb10Zr possui resistência à corrosão ligeiramente maior que a liga Ti6Al4V, assim como melhor comportamento tribocorrosivo quando realizado com baixa carga. Portanto, o filme passivo formado na liga Ti35Nb10Zr possui melhor resistência à corrosão e ao desgaste devido à presença de Nb2O5 e ZrO2. Porém, o metal base da liga Ti6Al4V apresentou menor desgaste mecânico. Concluindo, a liga de Ti35Nb10Zr é candidata promissora a ser utilizada na fabricação de conjuntos implantes-componentes protéticos. / Abstract: The long-life success of dental implants relies on the interaction between the biomaterial and oral environment, always involving electrochemical reactions, mechanical stresses and mechanical wear. In order to improve the mechanical strength and corrosion resistance of titanium (Ti), alloying elements are added to it, the most common alloy being Ti6Al4V. However, vanadium and aluminum are known to be toxic. Therefore, in last years, efforts are being made towards the development of new high resistant and biocompatible titanium alloys, namely from the TiNbZr system. Therefore, the aim of this work was to assess the corrosion and tribocorrosion behavior of new Ti35Nb5Zr and Ti35Nb10Zr in artificial saliva at 37°C, in comparison with the commercial Ti6Al4V alloy. Open circuit potential (Ecorr) and electrochemical impedance spectroscopy (EIS) experiments were carried in function of time (0-216h). Tribocorrosion tests were performed at different applied loads (50mN to 1N) both at Ecorr and anodic applied potential. In general, all alloys exhibited an increase of Ecorr with the immersion time, indicating the growth and stabilization of the passive film. The EIS results indicated that Ti35Nb10Zr alloy exhibited slightly better corrosion resistance than Ti6Al4V. Just as better tribocorrosion behavior at low applied loads. Therefore, the passive film formed on Ti35Nb10Zr alloy had better mechanical strength and corrosion resistance due to Nb2O5 e ZrO2. However, the bulk metal of Ti6Al4V suffered less mechanical wear. Concluding, Ti35Nb10Zr alloy appear as promising candidate for dental implant-abutment sets manufacturing. / Orientador: Luís Geraldo Vaz / Coorientador: Luís Augusto Sousa Marques da Rocha / Banca: Maria da Glória Chiarello de Mattos / Banca: Danilo Luiz Flumignan / Banca: Márcio Luiz dos Santos / Banca: Joni Augusto Cirelli / Doutor
17

Avaliação do efeito de centrifugado de medula óssea no processo de reparo ósseo ao redor de implantes instalados em tíbia de coelho : análise histológica e histométrica /

Betoni Júnior, Walter. January 2008 (has links)
Orientador: Pedro Felício Estrada Bernabé / Banca: Idelmo Rangel Garcia Júnior / Banca: Osvaldo Magro Filho / Banca: Vinicius Canavarros Palma / Banca: Ariel Lenharo / Resumo: O objetivo deste estudo experimental foi comparar histologicamente o reparo ósseo ao redor de implantes preenchidos por coágulo local com ou sem a associação de centrifugado de medula óssea, por meio de análises histológica e histométrica. Doze coelhos receberam dois implantes osseointegráveis em cada tíbia direita, onde a primeira cortical foi preparada com 5 mm e a segunda, ou cortical inferior, com 3 mm. Os implantes foram estabilizados na cortical inferior com 40 N, sendo um defeito preenchido por coagulo sanguíneo e o outro com coágulo e centrifugado de medula óssea. O sacrifício dos animais foi realizado nos períodos de 7, 21 e 60 dias. As peças foram submetidas a processamento laboratorial de rotina e coradas com vermelho de alizarina e azul de Stevenel. Tanto o grupo coágulo quanto o grupo coágulo e centrifugado de medula, após 60 dias, tiveram seus defeitos preenchidos por tecido ósseo, não apresentando diferença estatística entre os grupos quanto à extensão linear de contato entre tecido ósseo e implante. / Abstract: The objective of this experimental study was to compare histologically the bone repair around implant filled out by local coagulum with or without association of bone marrow centrifuged through histological and histometric analysis. Twelve rabbits received two implants in the right tibia, where the first cortical it was prepared with 5 mm and the second or lower cortical, with 3 mm. The implants were stabilized in lower cortical with 40 N, being one defect filled out by blood coagulum and the other filled out by blood coagulum and bone marrow centrifuged. The sacrifice of the animals was accomplished in the periods of 7, 21 and 60 days. The pieces were submitted to routine laboratorial process and stained with alizarin red and Stevenel's blue. Both groups had their defects filled by bone after 60 days, not presenting statistical difference between the groups about the linear extension of contact between bone tissue and implant. / Doutor
18

Osteogênese sobre titânio com nanotopografia /

Schwartz Filho, Humberto Osvaldo. January 2011 (has links)
Orientador: Resemary Adriana Chierici Marcantonio / Banca: Eduardo Hochuli Vieira / Banca: José Eduardo Cezar Sampaio / Banca: Fábio André dos santos / Banca: Sergio Luis Scombatti de Souza / Resumo: Os objetivos deste estudo foram avaliar a influência da nanotopografia de superfícies de titânio no processo de osteogênese por meio de avaliação histológica do contato osso-implante, em ratos, sob efeito da inalação forçada da fumaça de cigarro; Avaliar a osteogênese e a expressão de citocinas em cultura de células primárias sobre discos de titânio com nanotopografia; E avaliar o efeito morfológico e molecular da incorporação da laminina-1 (LN-1) em superfícies com nanotopografia, em coelhos. Implantes e discos de titânio foram especialmente produzidos e submetidos a diferentes métodos para a obtenção de superfícies: usinada, micro e nanotopografia. As superfícies foram devidamente caracterizadas quanto a sua topografia, morfologia e química. Os resultados mostraram que: a nanotopografia é capaz de aumentar o contato osso-implante (BIC) mesmo na presença da inalação intermitente da fumaça de cigarro, e foi capaz de reduzir, porem não totalmente, seus efeitos deletérios e uma menor formação óssea; A nanotopografia de titânio pode ter papel importante no processo de mineralização da matriz extracelular e na modulação da expressão de citocinas; E que a incorporação de LN-1 a superfície de titânio com nanotopografia demonstrou favorecer uma maior expressão de importantes genes envolvidos na cascata da osseointegração. / Abstract: The aims of this study were to evaluate the influence of nanotopography of titanium surfaces in the process of osteogenesis by means of histological assessment of bone-implant contact, in rats, under the effect of forced inhalation of cigarette smoke; To assess the osteogenesis process and the expression of cytokines in primary cell culture on titanium disks with nanotopography; And evaluate morphological and molecular the effect of incorporation of laminin-1 (LN-1) surfaces with nanotopography, in rabbits. Implants and titanium disks were specially produced and submitted to different methods for obtaining surfaces with turned, micro and nanotopography. The surfaces have been properly characterized as its topography, morphology and chemistry. The results showed that: nanotopography is able to increase bone-implant contact (BIC) even in the presence of intermittent inhalation of cigarette smoke, and was able to reduce, although not entirely, their harmful effects and a lower bone formation; Nanotopography may play a important role in mineralization process and in cytokine expression.; And the incorporation of LN-1 on titanium surface with nanotopography favor a higher expression of important genes involved in the cascade of osseointegration. / Doutor
19

Influência do tipo de fundição e uso de retificação na interface pilar/cilindro protético na adaptação marginal e tensão peri-implantar sobre conexão protética tipo Micro-Unit/

Gonçalves, Marianna Cavalheiro. January 2009 (has links)
Orientador: Lafayette Nogueira Júnior / Banca: Eduardo Shigueyuki Uemura / Banca: Alfredo Mikail Mesquita / Resumo: O objetivo neste estudo foi avaliar, in vitro, a adaptação marginal por meio da microscopia óptica, de cilindros pré-fabricados de Co-Cr comparados com cilindros calcináveis fundidos em Ni-Cr pelo método convencional e pela fundição por indução, com e sem o uso de retificadores e analisar por meio da extensometria a tensão ao redor do implante gerada com o uso destes componentes parafusados sobre os pilares tipo Micro-Unit. Foram utilizados 36 cilindros tipo Micro-Unit subdivididos em 3 grupos: G1 (controle) - 12 cilindros pré-fabricados de Co-Cr; G2 - 12 cilindros calcináveis fundidos pelo método convencional em liga de níquel-cromo (Ni-Cr); G3 - 12 cilindros calcináveis fundidos pelo método de indução em liga de Ni-Cr. Para todos grupos foram realizadas as leituras no microscópio óptico com um aumento de 200 vezes e realizada a mensuração da tensão pela extensometria. Na análise microscópica foram realizadas quatro leituras para cada face do octógono no qual o implante estava instalado. A extensometria foi realizada durante o aperto do parafuso, com torquímetro eletrônico, do cilindro em questão após o implante estar devidamente posicionado sobre o aparato que garantia que o torque era gerado sem nenhuma influencia do operador. Posteriormente, os cilindros dos grupos 2 e 3 foram retificados formando dois sub-grupos: G2b e G3b, os quais foram novamente analisados em microscópio óptico e na extensometria. Os valores de média e desvio padrão encontrados na desadaptação marginal nos grupos foram: ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The main point of this study was to evaluate, in vitro, the marginal misfit using the optical microscopy Co-Cr cylinders prefabricated compared with abutment cylinders cast in Ni-Cr conventional casting and by induction, with and without use of rectifiers and analyzed with strain gages around the implant generated with the use of these components bolted on the Micro-Unit abutments. 36 micro-unit cylinders were divided into 3 groups: G1 (control) - 12-pre-fabricated Co-Cr cylinders, G2 - 12 cylinders copings cast with conventional nickel-chromium (Ni-Cr)alloy, G3 - 12 cylinders copings cast method of induction in the Ni-Cr. For all groups were performed measurements at optical microscope with an increase of 200 times (200x) and performed the strain gages measurement. In the microscopic analysis were performed four readings for each side of the octagon in which the implant was installed. The gage was carried out during tightening of the screw with an electronic torque wrench drum in question after the implant to be properly positioned on the apparatus that guarantees that the torque was generated without any influence of the operator. Thereafter, the cylinders in groups 2 and 3 were rectified to form two sub-groups: G3B and G2b, which were further, analyzed using an optical microscope and the strain gages. The mean value and standard deviation found in the marginal discrepancy in the groups were: ... (Complete abstract click electronic access below) / Mestre
20

Influência do Diabetes mellitus e da insulinoterapia sobre a osseointegração : avaliação histométrica em coelhos /

Margonar, Rogério. January 2005 (has links)
Resumo: A indicação de implantes dentais osseointegráveis para pacientes com comprometimento sistêmico como o Diabetes Mellitus permanece controversa. O objetivo deste estudo foi avaliar, por meio de parâmetros histométricos, a influência do Diabetes Mellitus e da insulinoterapia sobre a osseointegração. Foram utilizados 34 coelhos adultos da raça Nova Zelândia, os quais foram divididos nos seguintes grupos: grupo controle (C), grupo diabético induzido (D) e grupo diabético tratado com insulina (DTI). A indução do diabetes foi realizada por administração de Aloxana (115 mg/kg). Os coelhos do grupo DTI receberam tratamento com injeção subcutânea de insulina (10 U/ dia) e os demais receberam solução salina (0,9%) pela mesma via. Cada animal recebeu dois implantes para análise histométrica. Após 4, 8 e 12 semanas, os animais foram sacrificados e as peças reduzidas para processamento histológico. Os três grupos não apresentaram diferenças em relação a área óssea (AO). Entretanto, o Grupo C apresentou maior extensão de contato osso/implante (ECOI) nos três períodos experimentais P<0,001 e os Grupos D e DTI não mostraram diferenças estatística em relação a ECOI P= 0,75. Assim, pode-se concluir que o Diabettes Mellitus influenciou negativamente a osseointegração de implantes colocados em tíbias de coelhos e a insulinoterapia não alterou este efeito. / Abstract: The indication for the placement of osseointegrated dental implants in patients with systemic illness, like diabetes, remains controversial. The purpose of this study was to evaluate, through the histrometric parameters , the influence of Diabetes Mellitus and its treatment with insulin, on osseointegration around implants. Thirty four New Zealand adult rabbits were separated in 3 groups: control group (C), diabetes group (D) and insulin treatment diabetes group (DTI). Aloxana (115mg/kg) was used in diabetes induction. The DTI group received treatment with insulin (10 U/ day) and the others received saline solution (0,9%). After 1 week, implants were placed bilaterally in the tibiae of rabbits. After 4, 8 and 12 weeks, the animals were sacrificed and the implants were analyzed. The bone area didn'tþ show statistically greater values to the D, C e DTI groups. The C group showed statistically greater values bone contact with the surface implant than D and DTI groups in all periods (p<0,001). The groups D and DTI didn't showed any significant differences between each other in any period evaluated for bone implant contact (p=0,765). Thus, it may be concluded that Diabettes Mellitus can negatively influence the osseointegration around implants in tibiae of rabbits and insulin therapy did not altered this effect. / Orientador: Elcio Marcantonio Junior / Coorientador: Maria Teresa Pepato / Doutor