• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • Tagged with
  • 41
  • 41
  • 41
  • 39
  • 36
  • 13
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência do formato do rebordo na associação de uma prótese parcial removível de extremidade livre mandibular associada ao implante com sistema de retenção ERA, pelo método dos elementos finitos /

Lucas, Liliana Vicente Melo de. January 2006 (has links)
Resumo: Associação das próteses parciais removíveis de extremidade livre com os implantes osseointegrados é, ainda, uma opção de tratamento pouco explorada na Odontologia reabilitadora moderna. Por isso, o objetivo deste estudo é avaliar, utilizando o método dos elementos finitos bidimensional, a distribuição de tensão e o deslocamento nas estruturas de suporte da prótese parcial removível de extremidade livre (PPREL) associada a um implante osseointegrado de 10,0 x 3,75 mm com sistema ERA de retenção, em diferentes formatos de rebordo alveolar. Para tanto, foram criados oito modelos, os quais, em corte sagital, representam: Modelo A (MA) - uma hemiarcada com rebordo horizontal, sem suporte posterior, com a presença do dente 33 e de uma PPREL convencional, com apoio metálico na incisal do dente 33, em substituição aos dentes 34, 35, 36 e 37; Modelo B (MB) - semelhante ao MA, diferenciando-se deste pela presença de um implante de 3,75 x 10,00 mm com sistema ERA de retenção associado, na região posterior da base da PPREL; Modelo C (MC) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação ascendente distal; Modelo D (MD) - semelhante ao MC, diferenciando-se deste pela presença do implante com sistema de retenção associado; Modelo E (ME) - semelhante ao MA, entretanto o rebordo distal apresenta uma conformação descendente distal; Modelo F (MF) - semelhante ao ME, diferenciando-se deste pela presença do implante com sistema ERA de retenção; Modelo G (MG) - semelhante ao MA, entretanto o rebordo distal apresenta formato descendente-ascendente; Modelo H (MH) - semelhante ao MG, diferenciando-se deste pela presença do implante com sistema ERA de retenção. Com o auxílio do programa de elementos finitos ANSYS 9.0, os modelos foram carregados com forças verticais de 50 N, em cada ponta de cúspide....(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The association of mandibular distal extension removable artial dentures with an osteointegrated implant is a treatmeat hasn't been fully explored by modern rehabilitation dentistry yet. For this reason, the objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension and the displacement on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. For that purpose, eight models were created, representing, from a sagittal perspective: Model A (MA) - a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) - similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) - similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) - similar to ME, but different in the sense that there is an implant with an associated ERA retention system; Model G (MG) - similar to MA, however with a distally descending-ascending ridge format; Model H (MH) - similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip...(Complete abstract, click electronic address below) / Orientador: Eduardo Piza Pellizzer / Coorientador: João Antonio Pereira / Banca: Adriano de Almeida de Lima / Banca: Paulo Renato Junqueira Zuim / Banca: Regina Tamaki / Banca: Wilson Roberto Poi / Doutor

Page generated in 0.0921 seconds