• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de novos parÃmetros para aprimoramento do controle de qualidade da cera de carnaÃba / Study of new parameters to improve the quality control of carnauba wax

Allan Nilson de Sousa Dantas 07 April 2014 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / CoordenaÃÃo de AperfeÃoamento de Pessoal de NÃvel Superior / A cera de carnaÃba consiste em um importante produto econÃmico e sua produÃÃo vem ao longo dos anos sofrendo com a escassez de trabalhos cientÃficos que auxiliem no entendimento das diferenÃas quÃmicas existentes entre os tipos de cera. Deste modo, o presente trabalho teve por objetivo propor uma caracterizaÃÃo dos diferentes tipos de cera de carnaÃba (Tipo 1, Tipo 3 e Tipo 4) quanto à sua composiÃÃo quÃmica, em especial em relaÃÃo aos constituintes inorgÃnicos. As amostras de cera foram avaliadas quanto à composiÃÃo orgÃnica por FT-IR, TG e CG-MS. Os resultados obtidos mostraram que as ceras dos Tipos 1, 3 e 4 possuem pequenas diferenÃas sÃo quanto a sua composiÃÃo orgÃnica fator que pode ser responsÃvel pela diferenÃa de coloraÃÃo entre os materiais, apresentando em sua composiÃÃo basicamente parafinas, Ãlcoois de cadeia longa e Ãsteres de Ãcidos graxos. Para avaliaÃÃo dos inorgÃnicos, uma etapa de otimizaÃÃo das condiÃÃes de preparo de amostra por via Ãmida assistida por micro-ondas foi implementada. Os digeridos apresentaram teores de carbono residual inferior a 5%, sendo feita a quantificaÃÃo dos elementos por ICP OES. Os teores mÃdios para os elementos investigados nas amostras de cera do Tipo 1 foram: K (22,3 mg Kg-1), Al (20,5 mg Kg-1), Fe (11,5 mg Kg-1), Mg (4,0 mg Kg-1), Na (3,5 mg Kg-1), Pb (2,2 mg Kg-1), Ca (1,2 mg Kg-1 ), Cu (0,5 mg Kg-1), Mn (0,4 mg Kg-1), Zn (0,2 mg Kg-1) e Co (0,2 mg Kg-1). Os teores observados para Ni (67,2 mg Kg-1 ) se mostraram elevados nas amostras de trÃs industrias, elevando o valor mÃdio do elemento. Para as amostras de cera de carnaÃba do Tipo 3, os valores mÃdios das concentraÃÃes dos elementos foram: Al (122,0 mg Kg-1), K (112,1 mg Kg-1), Ca (103,9 mg Kg-1), Fe (93,4 mg Kg-1), Mg (67,1 mg Kg-1), Na (39,6 mg Kg-1), Mn (9,6 mg Kg-1 ), Pb (1,7 mg Kg-1), Zn (0,6 mg Kg-1), Ni (0,3 mg Kg-1), Cu (0,2 mg Kg-1) e Co (0,1 mg Kg-1). Por fim, para as amostras de cera do Tipo 4, os valores mÃdios de concentraÃÃo observados foram: K (185,3 mg Kg-1), Ca (116,8 mg Kg-1), Al, (97,6 mg Kg-1), Fe (84,5 mg Kg-1 ), Mg (76,9 mg Kg-1), Na (37,6 mg Kg-1), Mn (8,7 mg Kg-1), Pb (2,3 mg Kg-1), Zn (0,7 mg Kg-1), Cu (0,2 mg Kg-1) e Co (0,1 mg Kg-1 ). Os dados foram tratados utilizando o software de Quimiometria The Unscrambler 7.1 e X10.3. AnÃlise de Componentes Principais mostrou que as ceras podem ser classificadas e distinguidas em funÃÃo dos teores das espÃcies avaliadas. Nesse contexto as ceras Tipo 4 apresentaram os maiores teores de inorgÃnicos, seguido das ceras do Tipo 3 e por fim das ceras do Tipo 1. Novas amostras de cera foram adquiridas com o intuito de desenvolver um modelo de calibraÃÃo multivariada (NIR/PLS) para previsÃo de Al, Ca, Cu, Fe, K, Mg, Mn e Na nas amostras de cera. Os espectros foram prÃ-processados aplicando 1 derivada ao conjunto de dados espectrais e em seguida foram obtidos os modelos utilizando PLS-1. As amostras de cera foram divididas em dois conjuntos de dados: um para calibraÃÃo e o outro para validaÃÃo. Os modelos obtidos se mostraram promissores para a previsÃo do teor de elementos como Al, Fe e Cu nas amostras de cera de carnaÃba. Por fim, os resultados obtidos neste trabalho podem ser utilizados como parÃmetros de classificaÃÃo das amostras de cera, bem como podem ser utilizados como aporte para a elaboraÃÃo de normas para classificaÃÃo dos teores de qualidade das ceras de carnaÃba produzidas pelas indÃstrias refinadoras. / Carnauba wax is an important economic product and its industrial production has over the years suffering from the scarcity of scientific studies to aid in the understanding of the chemical differences between different types of wax. The aim of this work was characterize the different types of carnauba waxes (Type 1, Type 3 and Type 4) in relation to the chemical composition. The organic matrix of the samples were investigated by Infrared Spectroscopy (MID and NIR), Thermal Analysis and Gas Chromatography (CGMS). The results showed that the three types of waxes are very similar in its organic composition, presenting in its composition mainly paraffin, alcohols and esters of long chain fatty acids. To evaluate inorganic content, an optimization of the conditions of the sample preparation by microwave assisted wet digestion implemented. The digests showed residual carbon content less than 5%. The analysis was performed by ICP-OES. The elements data set was processed using the software The Unscrambler 7.1 and X10.3. The mean values for the elements in the samples investigated wax Type 1 levels were: K (22.3 mg kg -1), Al (20.5 mg kg-1), Fe (11.5 mg kg-1), Mg (4.0 mg kg-1), Na (3.5 mg kg-1), Pb (2.2 mg kg-1), Ca (1.2 mg kg-1), Cu (0.5 mg kg-1), Mn (0.4 mg kg-1) , Zn (0.2 mg kg-1) and Co (0.2 mg kg-1). The levels observed for Ni (67.2 mg kg-1) were higher in samples from three industries, raising the average value of the element. For samples carnauba wax Type 3, the mean concentrations of elements were: Al(122.0 mg kg-1), K(112.1 mg kg-1), Ca (103.9 mg kg- 1), Fe(93.4 mg kg-1), Mg(67.1 mg kg-1), Na(39.6 mg kg-1), Mn(9.6 mg kg-1), Pb(1 7 mg kg-1), Zn (0.6 mg kg-1), Ni (0.3 mg kg-1), Cu (0.2 mg kg-1) and Co (0.1 mg kg-1). Finally, the samples with wax to Type 4, the mean concentration values were observed : K (185.3 mg kg-1), Ca (116.8 mg kg-1), Al (97.6 mg kg-1), Fe (84.5 mg kg-1) mg (76.9 mg kg-1), Na (37.6 mg kg-1), Mn (8.7 mg kg-1), Pb (2.3 mg kg-1), Zn (0.7 mg kg -1), Cu (0.2 mg kg-1) and Co (0.1 mg kg-1). Principal Component Analysis showed that the three types of waxes could be distinguished based on the levels of inorganic elements. In this view point waxes Type 4 showed the highest inorganic levels than the waxes Type 3 and Type 1. New wax samples were acquired with a view to developing a model of multivariate calibration (NIR / PLS) for prediction of Al, Ca, Cu, Fe, K, Mg, Mn and Na in wax samples. The spectra were preprocessed applying first derivative and then the models PLS-1 were obtained. The spectra data set were divided into two groups: one for the calibration and the other for validation. The models obtained were promising for predicting the content of elements such as Al, Fe and Cu in samples of wax. Finally, the results obtained in this work can be used as parameter for sample classification and as well as used for the development of standards rules for quality assurance of the carnauba waxes produced by refining industrial processes.
2

InvestigaÃÃo de Novas EstratÃgias de Preparo de Amostras OrgÃnicas Auxiliado por RadiaÃÃo Infravermelha / Research of new strategies for the preparation of organic samples aided by infrared radiation

Wellington Viana de Sousa 26 June 2013 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Este trabalho investiga a utilizaÃÃo da radiaÃÃo infravermelha como fonte de aquecimento no preparo de amostras orgÃnicas por via Ãmida visando à determinaÃÃo de elementos traÃos por ICP OES. As estratÃgias foram elaboradas com o objetivo de solubilizar e/ou digerir maiores massas de amostras. Assim, foram estudadas trÃs estratÃgias: 1) sistema IR-MW que combina o uso da radiaÃÃo infravermelha e micro-ondas, por meio de uma digestÃo prÃvia com radiaÃÃo infravermelha e posterior digestÃo no forno de micro-ondas com cavidade; 2) digestÃo parcial utilizando somente radiaÃÃo infravermelha (IR); 3) digestÃo parcial utilizando radiaÃÃo infravermelha e pentÃxido de vanÃdio (IR com V2O5) como reagente oxidante auxiliar. Diferentes procedimentos foram estudados sendo avaliados atravÃs da determinaÃÃo por ICP OES de macro e microelementos (Al, Fe, Cu, Mn, Zn, Se, Cd, Ni, Pb, Ca, K, Mg, Na e P) em diferentes tipos de leite em pÃ. O sistema IR-MW permitiu a digestÃo de massas de amostra de atà 1 g, obtendo-se boas precisÃes para a maioria dos elementos determinados. Para o procedimento IRMW A, a exatidÃo foi confirmada com material certificado Whole Milk Powder NIST 8435. Para os procedimentos IR-MW B e C foram obtidas percentagens de recuperaÃÃo variadas dependendo do elemento e da amostra. As estratÃgias IR e IR com V2O5 possibilitaram a digestÃo parcial de 2 g de amostra. A precisÃo e a exatidÃo desses procedimentos variaram de acordo com o elemento e a amostra. Todavia, a quantificaÃÃo de alguns elementos sà foi possÃvel por meio destas estratÃgias como, por exemplo, a detecÃÃo de Mn (0,30  0,01 Âg g-1 por IR; 0,35  0,01 Âg g-1 por IR com V2O5) na amostra de leite de cabra em pà integral e de Mn (1,63  0,02 Âg g-1 por IR; 1,78  0,06 Âg g-1 por IR com V2O5) na amostra de leite em pà desnatado nÃo enriquecido. O uso do V2O5 foi essencial na quantificaÃÃo de Fe (0,54  0,13 Âg g-1) no leite de cabra em pà integral. De uma maneira geral, dependendo do elemento e de seu teor na amostra, sua determinaÃÃo por ICP OES sà à possÃvel quando se usa maiores quantidades de massa de amostra. O emprego da radiaÃÃo infravermelha no auxilio de digestÃo de maiores massas de amostra à uma alternativa para laboratÃrios que utilizam apenas forno de micro-ondas com cavidade. / In this work it was investigated the use of infrared radiation as heating source in the preparation of organic samples aiming the determination of trace elements by ICP OES. The strategies were developed in order to solubilize and / or digest larger masses of samples. Thus, three strategies were studied: 1) IR-MW system which combines the use of infrared radiation and microwave through a previous digestion with infrared radiation and subsequent digestion in the oven microwave cavity; 2) partial digestion using only infrared radiation (IR); 3) partial digestion using infrared radiation and vanadium pentoxide (IR with V2O5) as auxiliary oxidizing reagent. Various procedures were studied and the efficiencies were evaluated by the determination of macro-and microelements (Al, Fe, Cu, Mn, Zn, Se, Cd, Ni, Pb, Ca, K, Mg, Na, and P) in milk samples by ICP OES. The IR-MW system allowed the digestion of sample masses of up to 1 g, to obtain good precision for most of the elements determined. For the IR-MW A procedure the accuracy was confirmed with certified material of whole milk powder NIST 8435. For the IR-MW B and C procedures were obtained recovery rates varied depending upon the element and the sample. Strategies IR and IR with V2O5 allowed the partial digestion of 2 g of sample. The precision and accuracy of these procedures varied according to the element and the sample. However, the determination of some elements was only possible using these strategies, for instance, the detection of Mn (0.30  0.01 Âg g-1 by IR; 0.35  0.01 Âg g-1 by IR with V2O5) in the goat whole milk powder sample of and Mn (1.63  0.02 Âg g-1 by IR; 1.78  0.06 Âg g-1 by IR with V2O5) in the non-fat milk powder not enriched sample. The use of V2O5 was essential in the quantification of some elements such as Fe (0.54  0.13 Âg g-1) in goat milk powder samples. In general, the determination of trace elements by ICP OES is only possible using larger amounts of sample, depending on the element and its content in the sample. The use of infrared radiation to accomplish the digestion of larger masses of samples is an alternative to using only laboratory microwave oven cavity.

Page generated in 0.1778 seconds