• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 175
  • 1
  • Tagged with
  • 185
  • 185
  • 105
  • 92
  • 91
  • 88
  • 59
  • 52
  • 47
  • 47
  • 47
  • 37
  • 36
  • 31
  • 31
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Análise de propostas de estratégias de controle para algumas topologias de multiconversores monofásicos. / Analysis of control strategies for some single-phase multiconverter topologies.

Giaretta, Antonio Ricardo 29 January 2009 (has links)
Este trabalho apresenta as principais topologias de conversores multinível descritos na literatura. É feita uma revisão bibliográfica, apresentando as vantagens e as limitações de cada topologia. A seguir são apresentados os métodos mais usuais de modulação para conversores multinível, bem como os campos de aplicação na indústria e em sistemas de potência As associações de conversores baseadas em conversores do tipo ponte completa monofásica foram escolhidas para um estudo mais detalhado. Para estas topologias são apresentados detalhes sobre as respectivas estratégias de controle e modulação. Inicialmente são apresentados os detalhes da ponte completa monofásica com tensão de saída modulada em PWM com dois e três níveis. A seguir são estudadas as associações série e paralela com barramentos CC isolados. O estudo da associação paralela com barramento CC único é a principal contribuição desta dissertação. Para esta topologia são propostas algumas estratégias de controle. Para todos estes casos são apresentados resultados de simulação e experimentais obtidos com inversores operando com potência reduzida, controlados por DSP. / This work presents the main multilevel converter topologies described in the literature. A bibliography revision is presented, showing the advantages and limitations of each topology. The most usual multilevel modulation methods are also presented, as well as their fields of application in the industry as well as in power systems. The one phase full bridge and its associations were chosen for detailed study. For this family of topologies, this dissertation presents details about control and modulation strategies. Initially, details about the one phase full bridge with two and three levels PWM modulated output voltage are presented. Next, the series association is analyzed, followed by the parallel with isolated DC link. The study of parallel connection with a single DC Link is the mainly contribution of this dissertation. For this topology are proposed some control strategies. For all these cases, simulation and experimental results (with, small scale prototype controlled by DSP) are presented.
42

Modelamento da malha de controle da corrente em conversores de potência modulados por largura de pulso. / Current control loop modeling of pulse width modulated power converters.

Miranda, Rubens Domingos de 30 July 2012 (has links)
Este trabalho propõe a adoção de uma estrutura de controle, com base na tese de doutorado de (BUEHNER, 2010), a qual utiliza um modelo com a dinâmica inversa da planta a ser controlada, de maneira a prover a pré-alimentação da tensão de referência para o controle de um conversor de potência monofásico, modulado por largura de pulso (PWM), obtendo-se bons resultados para o rastreamento da corrente do indutor de filtro conectado à saída deste conversor de potência. No trabalho, são apresentadas outras duas estruturas de controle por pré-alimentação, responsáveis respectivamente pelo cancelamento da perturbação gerada pela tensão na saída do filtro indutivo e pelo cancelamento do erro de tensão gerado pelo tempo morto. Com o intuito de assegurar o desempenho de rastreamento da corrente, face às variações de parâmetros do processo e as imperfeições existentes no modelamento da planta real, emprega-se a estrutura de controle proporcional, em malha fechada, assegurando a robustez da estrutura de controle, facilitando-se o ajuste da malha de controle. Os resultados de simulação e obtidos experimentalmente são comparados, validando-se efetivamente a estratégia de controle proposta. / This work presents the control structure based on (BUEHNER, 2010) PhD thesis, which uses an inverse dynamic model for the plant to be controlled, providing the feedforward voltage reference to control a single-phase, pulse width modulated power converter (VSI-PWM), achieving good results for the output inductor current tracking, connected on the power converter output. Two feedforward control structures are presented, for the cancellation of the voltage disturbance generated by the output filter voltage and the cancellation of voltage error generated by the dead time implementation, respectively. In order to ensure the current tracking performance in face of process parameter variations and modeling imperfections existing in the real plant, the closed loop proportional is employed under the proposed control structure, ensuring the control robustness, and facilitating the loop gain adjustments. The simulation and experimental results are obtained and compared, effectively evaluating the proposed control strategy.
43

Projeto e construção de um restaurador dinâmico de tensão. / Project and construction of a dynamic voltage restorer.

Galassi, Maurício 27 March 2006 (has links)
A crescente utilização de cargas sensíveis em aplicações industriais, atualmente tem levado a uma preocupação real devido aos custos provocados por interrupções e danos causados a linhas de produção automatizadas. Este trabalho apresenta uma solução baseada em sistemas de eletrônica de potência capaz de compensar Voltage Sags, Voltage Swells e distorções harmônicas de tensão, restaurando a tensão da carga a valores aceitáveis através de um transformador de injeção conectado em série entre a rede e a carga. As características de projeto para um protótipo de Restaurador Dinâmico de Tensão (DVR) são detalhadas, estratégias de controle são comparadas e uma das alternativas é implementada em um DSP (Digital Signal Processor). Finalmente, resultados experimentais de um protótipo de 5kVA são apresentados. / The increasing use of voltage sensitive loads on industrial applications has led to a real concern about interruption costs and damages on automatic production lines. This work presents a power-electronic-based device which compensates Voltage Sags, Voltage Swells and Voltage Harmonic Distortion, restoring the load voltage to acceptable values through a series connected injection transformer. The ratings and power requirements of a Dynamic Voltage Restorer (DVR) are derived, as well as its control algorithm implemented in a Digital Signal Processor (DSP). Finally, simulation and experimental results of a 5kVA prototype are presented.
44

Proposta de malha de controle de corrente do capacitor para inversor de tensão senoidal para unidade de alimentação ininterrupta alimentando cargas não lineares. / Capacitive current control loop for an UPS sinusoidal voltage source inverter feeding non linear loads.

Yamada, Ronaldo Hideki 20 August 2010 (has links)
O objetivo deste trabalho é analisar uma topologia de controle para a malha de tensão de um inversor para fontes de alimentação ininterruptas (UPS) com forma de onda senoidal na saída. É proposto um sistema de controle com duas malhas, uma de tensão com controlador ressonante e outra do tipo PI de corrente no qual a variável de controle é a corrente do capacitor de filtro de saída. Mais especificamente pretende-se estudar o problema de rastreamento de tensão nos inversores de UPS monofásicos, apresentando o estado da arte e uma classificação dos controladores que servem de solução para este problema específico. / This work analyses a uninterruptible power supply (UPS) inverter control scheme with sinusoidal output voltage. A two-loop control scheme is proposed; one voltage loop using a resonant controller and a PI current controller with the output capacitor filter current as control variable. A review on voltage tracking control in one-phase voltage source inverter is presented, showing the state of the art and a controller classification for this specific problem.
45

Controle eletrônico de potência em aquecedores elétricos de passagem por semi ciclos otimizados. / Power electronica control in direct water heater of optimized half cycles.

Oliveira Júnior, Cláudio José de 21 August 2006 (has links)
Os modernos equipamentos elétricos de aquecimento de água de passagem, popularmente conhecidos como chuveiros, duchas ou aquecedores, possuem como elementos aquecedores resistências elétricas constituídas por um fio de liga metálica enrolado, geralmente em ferro-cromo-alumínio ou níquel-cromo. O controle da temperatura da água é usualmente realizado pelo controle do fluxo d'água e pela mudança das derivações ("taps") presentes na resistência. A simplicidade deste controle se opõe à sua falta de flexibilidade para impor ajuste simultâneo de temperatura e vazão d'água. Um controle eletrônico de potência é oferecido como diferencial nos modelos mais sofisticados. Os modelos atualmente existentes no mercado são implementados com controle eletrônico por ângulo de fase, e é sabido que esse tipo de controle gera problemas de distorção harmônica de corrente das redes de energia, com a presença de harmônicas superiores de corrente (acima da fundamental) cuja filtragem é de difícil implementação devido ao nível de potência envolvido e às dimensões físicas dos aparelhos de aquecimento. Como alternativa a esse tipo de controle existe o controle por ciclos inteiros, o qual não gera harmônicas superiores de corrente, mas traz outro inconveniente, que é a produção de variação de tensão da rede de energia, que acarreta variação de luminosidade nas lâmpadas da instalação em níveis de freqüência perceptíveis ao olho humano (fenômeno conhecido como cintilação ou "flicker"). O objetivo do presente trabalho é propor uma solução otimizada ao controle de potência por ciclos inteiros, onde o mesmo é implementado por semi ciclos inteiros "otimizados" de forma a não gerar distorção harmônica nem cintilação de luminosidade perceptível ao olho humano. / Modern electrical direct water heating (DWH) equipments use electrical resistances built with metal alloys (iron-chrome-aluminum or nickel-chrome) as heating elements. Water temperature control is usually made with water flow control, as well as with resistance tap changing. The simplicity of this approach conflicts with to the lack of flexibility to allow simultaneous control of both water flow and its temperature. Therefore, an electronic power control is usually found in more sophisticated models. Usually the electronic power control is implemented by using phase angle control, which causes higher order current harmonics distortion of AC line currents, and filtering is difficult due to the high level of power involved and to the limited dimensions of typical electrical DWH equipment. The alternative for this type of power control is the cycle-by-cycle power control, which does not generate higher order current harmonics but creates line voltage variation, which in turn provokes lighting level variation and resulting unsteadiness on visual sensation, also known as flicker. The aim of the present work is to present an optimized solution for a half-cycle power control, in a way that does not generate harmonic distortion nor eye perceptible level of flicker.
46

Estudo de estratégias de rastreamento da corrente e da tensão de saída CA de um conversor do tipo fonte de tensão. / Output voltage and current tracking strategies of a voltage source converter.

Martinz, Fernando Ortiz 28 September 2007 (has links)
Este trabalho apresenta algumas estratégias de controle das malhas de rastreamento de tensão e corrente no lado CA de conversores do tipo fonte de tensão com filtro L ou LC. A topologia escolhida para o controle de tensão CA do inversor é a de duas malhas de controle em cascata: malha de tensão e malha de corrente, sendo esta última mais interna no sistema de controle. A metodologia de trabalho utilizada consiste na modelagem do sistema (sistema controlado e controladores), ajuste dos parâmetros do controlador, simulação computacional do sistema \"inversor + controlador\", implementação de alguns controladores propostos utilizando um DSP e testes em um sistema real com inversor. O estudo das técnicas de controle concentra-se inicialmente na estratégia de realimentação de dois estados no domínio de tempo contínuo, evoluindo para estratégias em tempo discreto que consideram o atraso na atuação do inversor devido ao tempo de cálculo do algoritmo de controle. Em tempo discreto, são analisados controladores preditivos para as malhas de tensão e corrente, bem como o emprego de controladores Proporcional-Integral (PI) na malha de tensão. Os dois últimos controladores são testados em um inversor PWM de baixa potência para diversos tipos de carga, com tensão de referência de inversor senoidal em 60Hz e referência contendo harmônicas. / This work presents some control strategies to achieve voltage and current tracking at the AC side of Voltage Source Converters with L or LC output filters. The topology of voltage control is the Multi-loop control with two loops: Voltage (outer loop) and Current Loop (inner loop). The proposed methodology consists in modeling the control system (plant and controllers), tuning of the controller parameters, simulating the complete system including inverter and controller, implementation of the proposed control strategies on a Digital Signal Processor (DSP) and tests in a power converter. The thesis is initially focused on a state variable continuous time controller with two states and then discrete-time strategies which consider the actuation delay due to the time required to evaluate the control algorithm are studied. In these discrete-time models, predictive controllers in voltage and current loops are analyzed, as well as the use of Proportional- Integral (PI) controllers in the Voltage Loop. These two last control topologies are tested in a low-power inverter for several load conditions with sinusoidal 60Hz inverter reference voltage and with harmonic distortion in the inverter reference voltage.
47

Métodos de sincronização de conversores em sistemas de geração distribuída

Pereira de Arruda, Josué 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T17:37:50Z (GMT). No. of bitstreams: 2 arquivo5359_1.pdf: 2762932 bytes, checksum: 0ca3cda75d19c5289f1914aaa550bbc1 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de conversores de freqüência CC/CA para integrar a energia renovável como uma fonte de geração distribuída tem se tornado cada vez mais comum. Em tais aplicações, a sincronização com o vetor tensão da rede é fundamental para o controle do conversor, particularmente considerando os novos requisitos de suportabilidade a afundamentos de tensão demandados das gerações distribuídas atualmente. Este trabalho propõe um novo método de sincronização aplicado ao controle de conversores de freqüência apresentado-se imune a condições anormais de operação da rede. Quatro outros métodos de sincronização encontrados na literatura são apresentados enfatizando-se suas capacidades de fornecerem respostas corretas diante de tensões desequilibradas e distorcidas. O método proposto é simulado computacionalmente e comparado às demais técnicas. Os resultados experimentais também são mostrados, com o qual o novo método consegue eliminar a influência de desequilíbrios e harmônicos na estimação da fase, da freqüência e da magnitude do vetor tensão da rede. O método proposto é modelado como aplicado ao controle do conversor de uma turbina eólica conectada ao sistema elétrico. São implementadas duas estratégias de controle do conversor do lado da rede para avaliar a independência dos resultados em relação a técnica de controle de corrente. Afundamentos momentâneos de tensão no ponto de conexão são simulados e os resultados obtidos com o método proposto mostraram que a turbina eólica não perdeu a estabilidade
48

Projeto e construção de um restaurador dinâmico de tensão. / Project and construction of a dynamic voltage restorer.

Maurício Galassi 27 March 2006 (has links)
A crescente utilização de cargas sensíveis em aplicações industriais, atualmente tem levado a uma preocupação real devido aos custos provocados por interrupções e danos causados a linhas de produção automatizadas. Este trabalho apresenta uma solução baseada em sistemas de eletrônica de potência capaz de compensar Voltage Sags, Voltage Swells e distorções harmônicas de tensão, restaurando a tensão da carga a valores aceitáveis através de um transformador de injeção conectado em série entre a rede e a carga. As características de projeto para um protótipo de Restaurador Dinâmico de Tensão (DVR) são detalhadas, estratégias de controle são comparadas e uma das alternativas é implementada em um DSP (Digital Signal Processor). Finalmente, resultados experimentais de um protótipo de 5kVA são apresentados. / The increasing use of voltage sensitive loads on industrial applications has led to a real concern about interruption costs and damages on automatic production lines. This work presents a power-electronic-based device which compensates Voltage Sags, Voltage Swells and Voltage Harmonic Distortion, restoring the load voltage to acceptable values through a series connected injection transformer. The ratings and power requirements of a Dynamic Voltage Restorer (DVR) are derived, as well as its control algorithm implemented in a Digital Signal Processor (DSP). Finally, simulation and experimental results of a 5kVA prototype are presented.
49

Modelamento da malha de controle da corrente em conversores de potência modulados por largura de pulso. / Current control loop modeling of pulse width modulated power converters.

Rubens Domingos de Miranda 30 July 2012 (has links)
Este trabalho propõe a adoção de uma estrutura de controle, com base na tese de doutorado de (BUEHNER, 2010), a qual utiliza um modelo com a dinâmica inversa da planta a ser controlada, de maneira a prover a pré-alimentação da tensão de referência para o controle de um conversor de potência monofásico, modulado por largura de pulso (PWM), obtendo-se bons resultados para o rastreamento da corrente do indutor de filtro conectado à saída deste conversor de potência. No trabalho, são apresentadas outras duas estruturas de controle por pré-alimentação, responsáveis respectivamente pelo cancelamento da perturbação gerada pela tensão na saída do filtro indutivo e pelo cancelamento do erro de tensão gerado pelo tempo morto. Com o intuito de assegurar o desempenho de rastreamento da corrente, face às variações de parâmetros do processo e as imperfeições existentes no modelamento da planta real, emprega-se a estrutura de controle proporcional, em malha fechada, assegurando a robustez da estrutura de controle, facilitando-se o ajuste da malha de controle. Os resultados de simulação e obtidos experimentalmente são comparados, validando-se efetivamente a estratégia de controle proposta. / This work presents the control structure based on (BUEHNER, 2010) PhD thesis, which uses an inverse dynamic model for the plant to be controlled, providing the feedforward voltage reference to control a single-phase, pulse width modulated power converter (VSI-PWM), achieving good results for the output inductor current tracking, connected on the power converter output. Two feedforward control structures are presented, for the cancellation of the voltage disturbance generated by the output filter voltage and the cancellation of voltage error generated by the dead time implementation, respectively. In order to ensure the current tracking performance in face of process parameter variations and modeling imperfections existing in the real plant, the closed loop proportional is employed under the proposed control structure, ensuring the control robustness, and facilitating the loop gain adjustments. The simulation and experimental results are obtained and compared, effectively evaluating the proposed control strategy.
50

Conversor CC-CC ZVS em ponte completa para aplicação em máquinas de soldagem processo eletrodo revestido /

Santos, Alexandre José Araujo dos, 1969-, Peres, Adriano, 1969-, Oliveira, Sérgio Vidal Garcia, 1974-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Elétrica. January 2010 (has links) (PDF)
Orientador: Adriano Peres. / Co-orientador: Sérgio Vidal Garcia Oliveira. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Elétrica.

Page generated in 0.0842 seconds