• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 3
  • Tagged with
  • 14
  • 14
  • 13
  • 8
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da quantidade de formaldeído liberado por alguns cimentos endodônticos / Evaluation of the quantity of formaldehyde released by some endodontic sealers

Ozorio, Jose Estevam Vieira 27 April 2012 (has links)
Analisou-se, por meio de espectrofotometria, a liberação de formaldeído de cimentos endodônticos à base de óxido de zinco e eugenol, resinas epóxica e polimetacrilato, hidróxido de cálcio e biocerâmico, estudados em diferentes oportunidades: durante a espatulação; decorrido três vezes o tempo de endurecimento e, por fim, na extração de sua massa endurecida. As amostras foram adquiridas pela coleta do volume da água utilizada em cada período e, determinada a curva de calibração da liberação do formaldeído e análise controle com água, foram submetidas à análise colorimétrica com adição dos reagentes: 5,0 mL de solução tampão, 0,5 mL de solução de parafenilenodiamina e 2,5 mL de peróxido de hidrogênio em balões volumétricos de 50,0 mL mantendo-os em repouso por 20 minutos. Após, foi realizada leitura em espectrofotômetro duplo feixe nos comprimentos de onda 326, 334 e 462 nm. Detectou-se formaldeído em todos os cimentos à base de resina epóxica, no EndoREZ® e no Endomèthasone N, quantificado apenas no Sealer 26 (7.40 mg.L-1) e Endomèthasone N (9.13 mg.L-1) durante a espatulação; no AH Plus® (4.44 mg.L-1) e no Endomèthasone N (18.14 mg.L-1) durante o endurecimento, e somente no Endomèthasone N depois de endurecido (9.43 mg.L- 1). Concluiu-se que, durante a espatulação, todos os cimentos de resina epóxica liberaram formaldeído, com quantificação apenas para o Sealer 26, o Endomèthasone N apresentou a maior quantidade, e o Endorez liberou a substância em quantidade insuficiente para quantificação. Após a espatulação, todos os de resina epóxica liberaram formaldeído, com quantificação no AH Plus e o Endomèthasone N apresentou a maior quantidade da substância, que também foi encontrada no Endorez, sem quantificação. Endurecidos, todos os cimentos de resina epóxica e o Endorez liberaram formaldeído em quantidade insuficiente para quantificação, e o cimento Endomèthasone N liberou a maior quantidade dessa substância. / This study evaluated, by means of spectrophotometry, the release of formaldehyde in zinc oxide, epoxy resins and polymethylmethacrylate, calcium hydroxide and bioceramic based endodontic sealers in different situations: during mixing; after 3 time the setting time and, at extraction of its hardened mass. The samples were acquired by means of collection of the volume of water used in each period and - after determining the calibration curve of formaldehyde release and analyzing the control with water - were submitted to colorimetric analysis with the addition of the following reagents: 5.0mL of buffered solution, 0.5mL of paraphenylenediamine and 2.5mL of hydrogen peroxide to a 50.0mL volumetric flask, which was kept at rest for 20 minutes. Double-beam spectrophotometer readings were performed at 326, 334 and 462nm wavelengths. Formaldehyde was detected in all epoxy resin based sealers, in EndoREZ and in Endomèthasone N, quantified only in Sealer 26 (7.40 mg.L-1) and Endomèthasone N (9.13 mg.L-1) during mixing, and in AH Plus (4.44 mg.L-1) and Endomèthasone N (18.14 mg.L-1) during the setting time, and only in Endomèthasone N after setting (9.43 mg.L-1). It can be concluded that during mixing all epoxy resin based sealers released formaldehyde, with quantification being possible only for Sealer 26, Endomèthasone N showed higher quantities, and Endorez released the substance in insufficient quantity for detection. After mixing, all epoxy resin based sealers released formaldehyde, whereas quantification was possible for AH Plus and Endomèthasone N presented the highest quantity of the substance, that was also found in Endorez, but could not be quantified. When set, all epoxy resin sealers and Endorez released formaldehyde in insufficient quantity for quantification, and Endomèthasone N released the greater amount of this substance.
2

Influência da adição de microesferas contendo amoxicilina nas propriedades físicas, químicas e biológicas de um cimento endodôntico experimental

Dornelles Junior, Nélio Bairros January 2016 (has links)
O objetivo do estudo foi desenvolver um cimento endodôntico com microesferas contendo amoxicilina e avaliar suas propriedades. As microesferas foram produzidas por secagem e caracterizadas por Microscopia eletrônica de varredura (MEV) e difração a laser. A formulação da resina base para um cimento endodôntico dual foi obtida pela mistura, em massa, de 70% de UDMA, 15% de GDMA e 15% de BISEMA. Como sistema iniciador/ativador, foram incorporados canforoquinona, DHEPT e peróxido de benzoíla, a 1% em mol e BHT em 0,01% em massa. Foram adicionados à resina base, em massa, 10 e 15% de microesferas de amoxicilina, além de um grupo sem microesferas (controle). Em todos os grupos foi adicionado trifluoreto de itérbio (10% em massa) como agente radiopacificante. Os cimentos foram avaliados quanto ao grau de conversão (GC) por Raman (n=3) imediatamente e após 24 horas de armazenamento, degradação em solvente (n=3) após 1 hora de imersão em álcool 70%, perfil de liberação do fármaco (n=3), atividade antimicrobiana contra Enterococcus Faecallis (n= 3), escoamento (n=3) e espessura de película (n=3)e citotoxicidade (n=3). Os dados foram analisados por ANOVA e Tukey com nível de significância de 5%. As microesferas apresentaram diâmetro médio de 2,664 μm. O grau de conversão imediato variou entre 51,73% e 55,13% e em 24h variou entre 60,79% e 73,80% sem apresentar diferença estatística entre os grupos. O percentual de degradação em solvente apresentou diferença significativa entre o grupo controle e o grupo com 15% de microesferas, variando entre 54,44% e 56,21% de redução. O perfil de liberação do fármaco mostrou que em 96h ocorreu uma liberação média de 73,76% do fármaco. A atividade antimicrobiana apresentou redução significativa dos grupos experimentais em 24 e 48h. Em 96h o grupo com 15% não apresentou diferença estatística quando comparado ao grupo controle (p>0,05). O escoamento apresentou uma redução significativa nos grupos experimentais comparados ao grupo controle (p<0,05). A espessura de película variou, mas não apresentou diferença estatística entre os grupos (p=0,63). A citotoxicidade apresentou alta viabilidade celular no tempos avaliados. Com base nesses resultados, pode-se concluir que a adição de até 10% de microesferas contendo amoxicilina apresentou característica antimicrobiana e não alterou as propriedades do cimento endodôntico experimental. / The objective of the study was to develop an endodontic sealer with amoxicillin-loaded microsphere and to evaluate its properties. The microspheres were produced by drying and characterized by Scanning Electron Microscopy (SEM) and laser diffraction. The formulation of the base resin dual cure endodontic cement was obtained by mixing, by weight, 70% UDMA, 15% GDMA and 15% BISEMA. As initiator / activator system, camphorquinone, DHEPT and benzoyl peroxide, 1 mol% and BHT were incorporated in 0.01% by weight. 10 and 15% of amoxicillin microspheres were added to the base resin, in addition to a group without microspheres (control). Ytterbium trifluoride (10% by weight) as radiopacifier was added in all groups. The cements were evaluated for Raman (n=3) conversion grade immediately after 24 hours storage, solvent degradation (n=3) after 1 hour immersion in 70% alcohol, drug release profile (n=3), antimicrobial activity against E. faecallis (n=3), flow (n=3) and film thickness (n=3) and cytotoxicity (n=3). Data were analyzed by ANOVA and Tukey with significance level of 5%. The microspheres had an average diameter of 2,664 μm. The degree of immediate conversion ranged from 51.73% to 55.13%, and in 24h conversion ranged from 60.79% to 73.80%, with no statistical difference between the groups. The percentage of degradation in solvent showed a significant difference between the control group and the group with 15% of microspheres, varying between 54.44% and 56.21% reduction. The drug release profile showed that a mean release of 73.76% of the drug occurred in 96h. The antimicrobial activity showed a significant reduction of the experimental groups in 24 and 48h. In 96h the group with 15% presented no statistical difference when compared to the control group (p> 0.05). The flow showed a significant reduction in the experimental groups compared to the control group (p <0.05). The film thickness varied, but did not present statistical difference between the groups (p = 0.63). Cytotoxicity showed high cellular viability at the determined times. Based on these results, it can be concluded that the addition of up to 10% of microspheres containing amoxicillin showed antimicrobial characteristics and did not alter the properties of the experimental endodontic cement.
3

Avaliação da quantidade de formaldeído liberado por alguns cimentos endodônticos / Evaluation of the quantity of formaldehyde released by some endodontic sealers

Jose Estevam Vieira Ozorio 27 April 2012 (has links)
Analisou-se, por meio de espectrofotometria, a liberação de formaldeído de cimentos endodônticos à base de óxido de zinco e eugenol, resinas epóxica e polimetacrilato, hidróxido de cálcio e biocerâmico, estudados em diferentes oportunidades: durante a espatulação; decorrido três vezes o tempo de endurecimento e, por fim, na extração de sua massa endurecida. As amostras foram adquiridas pela coleta do volume da água utilizada em cada período e, determinada a curva de calibração da liberação do formaldeído e análise controle com água, foram submetidas à análise colorimétrica com adição dos reagentes: 5,0 mL de solução tampão, 0,5 mL de solução de parafenilenodiamina e 2,5 mL de peróxido de hidrogênio em balões volumétricos de 50,0 mL mantendo-os em repouso por 20 minutos. Após, foi realizada leitura em espectrofotômetro duplo feixe nos comprimentos de onda 326, 334 e 462 nm. Detectou-se formaldeído em todos os cimentos à base de resina epóxica, no EndoREZ® e no Endomèthasone N, quantificado apenas no Sealer 26 (7.40 mg.L-1) e Endomèthasone N (9.13 mg.L-1) durante a espatulação; no AH Plus® (4.44 mg.L-1) e no Endomèthasone N (18.14 mg.L-1) durante o endurecimento, e somente no Endomèthasone N depois de endurecido (9.43 mg.L- 1). Concluiu-se que, durante a espatulação, todos os cimentos de resina epóxica liberaram formaldeído, com quantificação apenas para o Sealer 26, o Endomèthasone N apresentou a maior quantidade, e o Endorez liberou a substância em quantidade insuficiente para quantificação. Após a espatulação, todos os de resina epóxica liberaram formaldeído, com quantificação no AH Plus e o Endomèthasone N apresentou a maior quantidade da substância, que também foi encontrada no Endorez, sem quantificação. Endurecidos, todos os cimentos de resina epóxica e o Endorez liberaram formaldeído em quantidade insuficiente para quantificação, e o cimento Endomèthasone N liberou a maior quantidade dessa substância. / This study evaluated, by means of spectrophotometry, the release of formaldehyde in zinc oxide, epoxy resins and polymethylmethacrylate, calcium hydroxide and bioceramic based endodontic sealers in different situations: during mixing; after 3 time the setting time and, at extraction of its hardened mass. The samples were acquired by means of collection of the volume of water used in each period and - after determining the calibration curve of formaldehyde release and analyzing the control with water - were submitted to colorimetric analysis with the addition of the following reagents: 5.0mL of buffered solution, 0.5mL of paraphenylenediamine and 2.5mL of hydrogen peroxide to a 50.0mL volumetric flask, which was kept at rest for 20 minutes. Double-beam spectrophotometer readings were performed at 326, 334 and 462nm wavelengths. Formaldehyde was detected in all epoxy resin based sealers, in EndoREZ and in Endomèthasone N, quantified only in Sealer 26 (7.40 mg.L-1) and Endomèthasone N (9.13 mg.L-1) during mixing, and in AH Plus (4.44 mg.L-1) and Endomèthasone N (18.14 mg.L-1) during the setting time, and only in Endomèthasone N after setting (9.43 mg.L-1). It can be concluded that during mixing all epoxy resin based sealers released formaldehyde, with quantification being possible only for Sealer 26, Endomèthasone N showed higher quantities, and Endorez released the substance in insufficient quantity for detection. After mixing, all epoxy resin based sealers released formaldehyde, whereas quantification was possible for AH Plus and Endomèthasone N presented the highest quantity of the substance, that was also found in Endorez, but could not be quantified. When set, all epoxy resin sealers and Endorez released formaldehyde in insufficient quantity for quantification, and Endomèthasone N released the greater amount of this substance.
4

Influência da adição de microesferas contendo amoxicilina nas propriedades físicas, químicas e biológicas de um cimento endodôntico experimental

Dornelles Junior, Nélio Bairros January 2016 (has links)
O objetivo do estudo foi desenvolver um cimento endodôntico com microesferas contendo amoxicilina e avaliar suas propriedades. As microesferas foram produzidas por secagem e caracterizadas por Microscopia eletrônica de varredura (MEV) e difração a laser. A formulação da resina base para um cimento endodôntico dual foi obtida pela mistura, em massa, de 70% de UDMA, 15% de GDMA e 15% de BISEMA. Como sistema iniciador/ativador, foram incorporados canforoquinona, DHEPT e peróxido de benzoíla, a 1% em mol e BHT em 0,01% em massa. Foram adicionados à resina base, em massa, 10 e 15% de microesferas de amoxicilina, além de um grupo sem microesferas (controle). Em todos os grupos foi adicionado trifluoreto de itérbio (10% em massa) como agente radiopacificante. Os cimentos foram avaliados quanto ao grau de conversão (GC) por Raman (n=3) imediatamente e após 24 horas de armazenamento, degradação em solvente (n=3) após 1 hora de imersão em álcool 70%, perfil de liberação do fármaco (n=3), atividade antimicrobiana contra Enterococcus Faecallis (n= 3), escoamento (n=3) e espessura de película (n=3)e citotoxicidade (n=3). Os dados foram analisados por ANOVA e Tukey com nível de significância de 5%. As microesferas apresentaram diâmetro médio de 2,664 μm. O grau de conversão imediato variou entre 51,73% e 55,13% e em 24h variou entre 60,79% e 73,80% sem apresentar diferença estatística entre os grupos. O percentual de degradação em solvente apresentou diferença significativa entre o grupo controle e o grupo com 15% de microesferas, variando entre 54,44% e 56,21% de redução. O perfil de liberação do fármaco mostrou que em 96h ocorreu uma liberação média de 73,76% do fármaco. A atividade antimicrobiana apresentou redução significativa dos grupos experimentais em 24 e 48h. Em 96h o grupo com 15% não apresentou diferença estatística quando comparado ao grupo controle (p>0,05). O escoamento apresentou uma redução significativa nos grupos experimentais comparados ao grupo controle (p<0,05). A espessura de película variou, mas não apresentou diferença estatística entre os grupos (p=0,63). A citotoxicidade apresentou alta viabilidade celular no tempos avaliados. Com base nesses resultados, pode-se concluir que a adição de até 10% de microesferas contendo amoxicilina apresentou característica antimicrobiana e não alterou as propriedades do cimento endodôntico experimental. / The objective of the study was to develop an endodontic sealer with amoxicillin-loaded microsphere and to evaluate its properties. The microspheres were produced by drying and characterized by Scanning Electron Microscopy (SEM) and laser diffraction. The formulation of the base resin dual cure endodontic cement was obtained by mixing, by weight, 70% UDMA, 15% GDMA and 15% BISEMA. As initiator / activator system, camphorquinone, DHEPT and benzoyl peroxide, 1 mol% and BHT were incorporated in 0.01% by weight. 10 and 15% of amoxicillin microspheres were added to the base resin, in addition to a group without microspheres (control). Ytterbium trifluoride (10% by weight) as radiopacifier was added in all groups. The cements were evaluated for Raman (n=3) conversion grade immediately after 24 hours storage, solvent degradation (n=3) after 1 hour immersion in 70% alcohol, drug release profile (n=3), antimicrobial activity against E. faecallis (n=3), flow (n=3) and film thickness (n=3) and cytotoxicity (n=3). Data were analyzed by ANOVA and Tukey with significance level of 5%. The microspheres had an average diameter of 2,664 μm. The degree of immediate conversion ranged from 51.73% to 55.13%, and in 24h conversion ranged from 60.79% to 73.80%, with no statistical difference between the groups. The percentage of degradation in solvent showed a significant difference between the control group and the group with 15% of microspheres, varying between 54.44% and 56.21% reduction. The drug release profile showed that a mean release of 73.76% of the drug occurred in 96h. The antimicrobial activity showed a significant reduction of the experimental groups in 24 and 48h. In 96h the group with 15% presented no statistical difference when compared to the control group (p> 0.05). The flow showed a significant reduction in the experimental groups compared to the control group (p <0.05). The film thickness varied, but did not present statistical difference between the groups (p = 0.63). Cytotoxicity showed high cellular viability at the determined times. Based on these results, it can be concluded that the addition of up to 10% of microspheres containing amoxicillin showed antimicrobial characteristics and did not alter the properties of the experimental endodontic cement.
5

Influência da adição de microesferas contendo amoxicilina nas propriedades físicas, químicas e biológicas de um cimento endodôntico experimental

Dornelles Junior, Nélio Bairros January 2016 (has links)
O objetivo do estudo foi desenvolver um cimento endodôntico com microesferas contendo amoxicilina e avaliar suas propriedades. As microesferas foram produzidas por secagem e caracterizadas por Microscopia eletrônica de varredura (MEV) e difração a laser. A formulação da resina base para um cimento endodôntico dual foi obtida pela mistura, em massa, de 70% de UDMA, 15% de GDMA e 15% de BISEMA. Como sistema iniciador/ativador, foram incorporados canforoquinona, DHEPT e peróxido de benzoíla, a 1% em mol e BHT em 0,01% em massa. Foram adicionados à resina base, em massa, 10 e 15% de microesferas de amoxicilina, além de um grupo sem microesferas (controle). Em todos os grupos foi adicionado trifluoreto de itérbio (10% em massa) como agente radiopacificante. Os cimentos foram avaliados quanto ao grau de conversão (GC) por Raman (n=3) imediatamente e após 24 horas de armazenamento, degradação em solvente (n=3) após 1 hora de imersão em álcool 70%, perfil de liberação do fármaco (n=3), atividade antimicrobiana contra Enterococcus Faecallis (n= 3), escoamento (n=3) e espessura de película (n=3)e citotoxicidade (n=3). Os dados foram analisados por ANOVA e Tukey com nível de significância de 5%. As microesferas apresentaram diâmetro médio de 2,664 μm. O grau de conversão imediato variou entre 51,73% e 55,13% e em 24h variou entre 60,79% e 73,80% sem apresentar diferença estatística entre os grupos. O percentual de degradação em solvente apresentou diferença significativa entre o grupo controle e o grupo com 15% de microesferas, variando entre 54,44% e 56,21% de redução. O perfil de liberação do fármaco mostrou que em 96h ocorreu uma liberação média de 73,76% do fármaco. A atividade antimicrobiana apresentou redução significativa dos grupos experimentais em 24 e 48h. Em 96h o grupo com 15% não apresentou diferença estatística quando comparado ao grupo controle (p>0,05). O escoamento apresentou uma redução significativa nos grupos experimentais comparados ao grupo controle (p<0,05). A espessura de película variou, mas não apresentou diferença estatística entre os grupos (p=0,63). A citotoxicidade apresentou alta viabilidade celular no tempos avaliados. Com base nesses resultados, pode-se concluir que a adição de até 10% de microesferas contendo amoxicilina apresentou característica antimicrobiana e não alterou as propriedades do cimento endodôntico experimental. / The objective of the study was to develop an endodontic sealer with amoxicillin-loaded microsphere and to evaluate its properties. The microspheres were produced by drying and characterized by Scanning Electron Microscopy (SEM) and laser diffraction. The formulation of the base resin dual cure endodontic cement was obtained by mixing, by weight, 70% UDMA, 15% GDMA and 15% BISEMA. As initiator / activator system, camphorquinone, DHEPT and benzoyl peroxide, 1 mol% and BHT were incorporated in 0.01% by weight. 10 and 15% of amoxicillin microspheres were added to the base resin, in addition to a group without microspheres (control). Ytterbium trifluoride (10% by weight) as radiopacifier was added in all groups. The cements were evaluated for Raman (n=3) conversion grade immediately after 24 hours storage, solvent degradation (n=3) after 1 hour immersion in 70% alcohol, drug release profile (n=3), antimicrobial activity against E. faecallis (n=3), flow (n=3) and film thickness (n=3) and cytotoxicity (n=3). Data were analyzed by ANOVA and Tukey with significance level of 5%. The microspheres had an average diameter of 2,664 μm. The degree of immediate conversion ranged from 51.73% to 55.13%, and in 24h conversion ranged from 60.79% to 73.80%, with no statistical difference between the groups. The percentage of degradation in solvent showed a significant difference between the control group and the group with 15% of microspheres, varying between 54.44% and 56.21% reduction. The drug release profile showed that a mean release of 73.76% of the drug occurred in 96h. The antimicrobial activity showed a significant reduction of the experimental groups in 24 and 48h. In 96h the group with 15% presented no statistical difference when compared to the control group (p> 0.05). The flow showed a significant reduction in the experimental groups compared to the control group (p <0.05). The film thickness varied, but did not present statistical difference between the groups (p = 0.63). Cytotoxicity showed high cellular viability at the determined times. Based on these results, it can be concluded that the addition of up to 10% of microspheres containing amoxicillin showed antimicrobial characteristics and did not alter the properties of the experimental endodontic cement.
6

Avaliação volumétrica da obturação dos canais radiculares realizada com diferentes cimentos e técnicas, por meio de microtomografia / Volumetric evaluation of root canal fillings performed with different sealers and techniques through microtomography

Araujo, Vanessa Lessa Cavalcanti de 21 January 2014 (has links)
O sucesso do tratamento endodôntico está associado não só com a limpeza e a instrumentação do sistema de canais radiculares (SCR), mas com a capacidade de selamento do material obturador principalmente do terço apical. O objetivo do presente estudo in vitro foi analisar o volume de guta-percha e de cimento endodôntico no milímetro apical das obturações, utilizando diferentes cimentos e técnicas de condensação. Para tanto, 64 incisivos centrais superiores foram preparados com instrumentos rotatórios de NiTi até o diâmetro cirúrgico #60.02, e então distribuídos aleatoriamente em quatro grupos. Para cada um usou-se um cimento diferente, a saber: Endofill, Sealer 26, AH Plus e Sealapex. E para cada cimento utilizado, metade dos dentes foi obturada pela técnica de condensação lateral ativa (n=8), e a outra metade, pela técnica da condensação lateral passiva (n=8). Feitas as obturações, os dentes foram submetidos ao exame tomográfico com o uso do microtomógrafo SkyScan 1174 v2. As imagens foram reconstruídas pelo programa NRecon e em seguida foi avaliado o parâmetro tridimensional do volume de cimento e guta-percha no milímetro apical, por meio do programa CTan. A análise de variância a dois critérios para o volume de guta-percha demonstrou haver diferença estatisticamente significante para o fator de variação Cimento endodôntico (p>0,05). Por meio do teste Tukey, observou-se que o grupo obturado com o Sealer 26 apresentou maior volume de guta-percha no milímetro apical do comprimento de trabalho quando comparado ao Endofill que se apresentou com menor volume. Já a análise de variância para o volume de cimento endodôntico demonstrou haver diferença estatisticamente significante para o fator de variação Cimento endodôntico (p<0,05), Técnica obturadora (p<0,05) e pelas interações dos fatores (p<0,05). O teste Tukey para o fator de variação Cimento endodôntico demonstrou que o grupo obturado com o Sealapex apresentou menor volume de cimento no milímetro estudado quando comparado ao grupo obturado com AH Plus e Sealer 26, que evidenciaram maior volume de cimento. Em relação ao fator de variação Técnica obturadora, a condensação lateral ativa apresentou menor volume de cimento comparada técnica passiva. Pode-se concluir que o maior volume de guta-percha foi encontrado nos dentes obturados com o cimento endodôntico Sealer 26, semelhantes aos obturados com Sealapex e AH Plus, independentemente da técnica de condensação. O menor volume de cimento endodôntico foi encontrado no grupo obturado com Sealapex, semelhante ao grupo obturado com o Endofill. Em relação à técnica obturadora, a condensação lateral ativa apresentou menor volume de cimento quando comparada à passiva. / The success of endodontic treatment is associated not only with the cleaning and the instrumentation of the root canal system (RCS) but also with the sealing ability mainly in the apical third of the filling material. The aim of this in vitro study was to analyze the volume of gutta-percha and sealer in the apical millimeter of the fillings, using different obturation technique and sealers. For that purpose, 64 maxillary central incisors were prepared with NiTi rotary instruments until the surgical diameter of #60.02, and then divided randomly into four groups. For each group, different sealers were used, such as Endofill, Sealer 26, AH Plus and Sealapex. And for each sealer used, half the teeth were obturated using an active lateral condensation technique (n=8), and the other half by passive lateral condensation technique (n=8). After the fillings procedures, samples were examined by SkyScan 1174 v2 micro-CT. Images were reconstructed by NRecon software, and then the dimensional parameter of the volume of sealer and gutta-percha at the apical millimeter was evaluated through the CTan program. The ANOVA Two-Way results for the analysis of the volume of guttapercha showed a statistically significant difference for endodontic sealer factor (p>0,05). The Tukey test showed that the group filled with Sealer 26 had higher volume of gutta-percha at the apical millimeter of working length when compared to that of the Endofill, which presented lower volumes. However, the ANOVA Two-Way analysis for the volume of sealer, showed a statistically significant difference for the endodontic sealer factor (p<0.05), obturation technique (p<0.05) and between the interactions of the factors (p<0.05). The Tukey test for the Sealer endodontic variation factor showed that the group filled with Sealapex had the lowest volume of sealer in the studied millimeter when compared to the group filled by AH Plus and Sealer 26, which had the highest volume of sealer. Regarding the filling technique variation factor, the active lateral condensation technique showed lower sealer volume than passive. It can be concluded that the higher volume of gutta-percha was found in teeth filled with sealer Sealer 26, similar to Sealapex and AH Plus, regardless of the technique of condensation. The lowest volume of sealer was found in the group filled with Sealapex, similar to the group filled with Endofill. Regarding the obturation technique, the active lateral condensation technique showed lowest volume of sealer than the passive.
7

Avaliação volumétrica da obturação dos canais radiculares realizada com diferentes cimentos e técnicas, por meio de microtomografia / Volumetric evaluation of root canal fillings performed with different sealers and techniques through microtomography

Vanessa Lessa Cavalcanti de Araujo 21 January 2014 (has links)
O sucesso do tratamento endodôntico está associado não só com a limpeza e a instrumentação do sistema de canais radiculares (SCR), mas com a capacidade de selamento do material obturador principalmente do terço apical. O objetivo do presente estudo in vitro foi analisar o volume de guta-percha e de cimento endodôntico no milímetro apical das obturações, utilizando diferentes cimentos e técnicas de condensação. Para tanto, 64 incisivos centrais superiores foram preparados com instrumentos rotatórios de NiTi até o diâmetro cirúrgico #60.02, e então distribuídos aleatoriamente em quatro grupos. Para cada um usou-se um cimento diferente, a saber: Endofill, Sealer 26, AH Plus e Sealapex. E para cada cimento utilizado, metade dos dentes foi obturada pela técnica de condensação lateral ativa (n=8), e a outra metade, pela técnica da condensação lateral passiva (n=8). Feitas as obturações, os dentes foram submetidos ao exame tomográfico com o uso do microtomógrafo SkyScan 1174 v2. As imagens foram reconstruídas pelo programa NRecon e em seguida foi avaliado o parâmetro tridimensional do volume de cimento e guta-percha no milímetro apical, por meio do programa CTan. A análise de variância a dois critérios para o volume de guta-percha demonstrou haver diferença estatisticamente significante para o fator de variação Cimento endodôntico (p>0,05). Por meio do teste Tukey, observou-se que o grupo obturado com o Sealer 26 apresentou maior volume de guta-percha no milímetro apical do comprimento de trabalho quando comparado ao Endofill que se apresentou com menor volume. Já a análise de variância para o volume de cimento endodôntico demonstrou haver diferença estatisticamente significante para o fator de variação Cimento endodôntico (p<0,05), Técnica obturadora (p<0,05) e pelas interações dos fatores (p<0,05). O teste Tukey para o fator de variação Cimento endodôntico demonstrou que o grupo obturado com o Sealapex apresentou menor volume de cimento no milímetro estudado quando comparado ao grupo obturado com AH Plus e Sealer 26, que evidenciaram maior volume de cimento. Em relação ao fator de variação Técnica obturadora, a condensação lateral ativa apresentou menor volume de cimento comparada técnica passiva. Pode-se concluir que o maior volume de guta-percha foi encontrado nos dentes obturados com o cimento endodôntico Sealer 26, semelhantes aos obturados com Sealapex e AH Plus, independentemente da técnica de condensação. O menor volume de cimento endodôntico foi encontrado no grupo obturado com Sealapex, semelhante ao grupo obturado com o Endofill. Em relação à técnica obturadora, a condensação lateral ativa apresentou menor volume de cimento quando comparada à passiva. / The success of endodontic treatment is associated not only with the cleaning and the instrumentation of the root canal system (RCS) but also with the sealing ability mainly in the apical third of the filling material. The aim of this in vitro study was to analyze the volume of gutta-percha and sealer in the apical millimeter of the fillings, using different obturation technique and sealers. For that purpose, 64 maxillary central incisors were prepared with NiTi rotary instruments until the surgical diameter of #60.02, and then divided randomly into four groups. For each group, different sealers were used, such as Endofill, Sealer 26, AH Plus and Sealapex. And for each sealer used, half the teeth were obturated using an active lateral condensation technique (n=8), and the other half by passive lateral condensation technique (n=8). After the fillings procedures, samples were examined by SkyScan 1174 v2 micro-CT. Images were reconstructed by NRecon software, and then the dimensional parameter of the volume of sealer and gutta-percha at the apical millimeter was evaluated through the CTan program. The ANOVA Two-Way results for the analysis of the volume of guttapercha showed a statistically significant difference for endodontic sealer factor (p>0,05). The Tukey test showed that the group filled with Sealer 26 had higher volume of gutta-percha at the apical millimeter of working length when compared to that of the Endofill, which presented lower volumes. However, the ANOVA Two-Way analysis for the volume of sealer, showed a statistically significant difference for the endodontic sealer factor (p<0.05), obturation technique (p<0.05) and between the interactions of the factors (p<0.05). The Tukey test for the Sealer endodontic variation factor showed that the group filled with Sealapex had the lowest volume of sealer in the studied millimeter when compared to the group filled by AH Plus and Sealer 26, which had the highest volume of sealer. Regarding the filling technique variation factor, the active lateral condensation technique showed lower sealer volume than passive. It can be concluded that the higher volume of gutta-percha was found in teeth filled with sealer Sealer 26, similar to Sealapex and AH Plus, regardless of the technique of condensation. The lowest volume of sealer was found in the group filled with Sealapex, similar to the group filled with Endofill. Regarding the obturation technique, the active lateral condensation technique showed lowest volume of sealer than the passive.
8

EVALUATION OF MODIFIED BIO-CERAMIC ENDODONTIC SEALERS FOR ANTIMICROBIAL EFFICACY: SYSTEMATIC REVIEW AND META-ANALYSIS

Patel, Vrunda 08 1900 (has links)
Endodontic treatments are significantly improved by the efficacy of root canal sealers against microbial invasion. This systematic review and meta-analysis focus on comparing the antimicrobial efficacy of nanoparticle-modified bio-ceramic endodontic sealers with conventional bio-ceramic sealers. This review adhered to PRISMA guidelines and included both in vitro and ex vivo studies after a comprehensive search in PubMed, Embase, and Web of Science. The antimicrobial property of the bioceramic sealers was analyzed through the colony forming units (CFU), the diameter of inhibition zone and microbial viability. Eleven studies were used for the analysis. Overall, results from the meta-analysis indicated that modified bio-ceramic sealers exhibit an enhanced antibacterial effect compared to their conventional counterparts. A standardized mean difference was computed across 11 studies and 28 sub study groups, revealing a significant antimicrobial effect size in favor of the nanoparticle-modified bio-ceramic sealer. However, high heterogeneity among studies was observed. Chitosan, silver and bioactive glass were among the common nanoparticles used to modify bio-ceramic sealers. A 2% concentration of chitosan nanoparticles showed the highest antimicrobial effect size. Despite the heterogeneity found in the study, the findings suggest that the modification of bio-ceramic sealers with nanoparticles possesses the potential to advance endodontic treatments. The promising direction of these nanoparticle enhancements indicates a valuable progression in endodontics, advocating for additional research and development to optimize the use of nanoparticles in clinical settings. / Oral Biology
9

Avaliação in vitro da citotoxicidade e genotoxicidade de diferentes cimentos endodônticos em fibroblastos V79 /

Silva, Gleyce Oliveira. January 2011 (has links)
Orientador: Carlos Henrique Ribeiro Camargo / Banca: Bruno das Neves Cavalcanti / Banca: Márcia Carneiro Valera / Resumo: Cimentos endodônticos podem liberar componentes tóxicos que interagem com os tecidos periapicais. A proposta deste trabalho foi avaliar a citotoxicidade e genotoxicidade de quatro cimentos endodônticos (EndoREZ, RoekoSeal, AHPlus e cimento experimental à base de óleo-resina da Copaifera multijuga) utilizando ensaios biológicos. Os cimentos foram mixados e incubados em estufa de umidade relativa a 37°C com 5% CO2 por 24 h. A exposição do meio de cultura aos cimentos ocorreu após 12 h do endurecimento dos cimentos. Células V79 foram expostas às diluições dos extratos por 24 h e a sobrevivência celular foi mensurada fotometricamente. A viabilidade celular foi mensurada pelo teste de MTT em espectrofotômetro e a genotoxicidade, indicada pela formação de micronúcleos, foi determinada após 24h do período de exposição. Os resultados da taxa de sobrevivência celular e a quantidade de danos ao DNA foram estatisticamente analisados pelo teste de Kruskal-Wallis (p<0,05). A citotoxicidade em relação ao grupo controle decresceu na seguinte ordem EndoREZ > Copaíba ≥ AH Plus > RoekoSeal. A formação de micronúcleos (MN) para indicar a genotoxicidade foi induzida somente pelos extratos do EndoREZ, sendo mais genotóxico que o EMS (controle positivo) / Abstract: Endodontic sealers could release toxic components that may interact with periapical tissues. The purpose of this study was to evaluate the cytotoxicity and genotoxicity of four endodontic sealers (EndoREZ, RoekoSeal, AHPlus and experimental root canal sealer- based on Copaifera multijuga oil-resin) using routine cell biology techniques. The sealers were mixed and incubated in a humidified incubator at 37°C with 5% CO2 in air for 24 h. The exposure of the culture medium to the sealers occurred after 12 h of cure. V79 cells were exposed to dilutions of this extracts for 24 h and cell survival was measured photometrically. The cell viability was measured by MTT test in a spectrophotometer and the genotoxicity as indicated by the formation of micronuclei was determined after a 24 h exposure period The results of the cell survival rates and the amount of DNA damage was statistically analyzed for Kruskal-Wallis (p<0.05) test. The ranking of cell survival from the most to the least toxic material was: EndoREZ> Copaíba ≥ AH Plus > RoekoSeal. The formation of micronuclei (MN) to indicate genotoxicity was induced only by extracts of EndoREZ, being more genotoxic than EMS (positive control) / Mestre
10

Avaliação in vitro da citotoxicidade e genotoxicidade de diferentes cimentos endodônticos em fibroblastos V79

Silva, Gleyce Oliveira [UNESP] 15 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-15Bitstream added on 2014-06-13T20:31:49Z : No. of bitstreams: 1 silva_go_me_sjc.pdf: 1111622 bytes, checksum: e539d76b4d826d8bae2e60a44de64ea5 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Cimentos endodônticos podem liberar componentes tóxicos que interagem com os tecidos periapicais. A proposta deste trabalho foi avaliar a citotoxicidade e genotoxicidade de quatro cimentos endodônticos (EndoREZ, RoekoSeal, AHPlus e cimento experimental à base de óleo-resina da Copaifera multijuga) utilizando ensaios biológicos. Os cimentos foram mixados e incubados em estufa de umidade relativa a 37°C com 5% CO2 por 24 h. A exposição do meio de cultura aos cimentos ocorreu após 12 h do endurecimento dos cimentos. Células V79 foram expostas às diluições dos extratos por 24 h e a sobrevivência celular foi mensurada fotometricamente. A viabilidade celular foi mensurada pelo teste de MTT em espectrofotômetro e a genotoxicidade, indicada pela formação de micronúcleos, foi determinada após 24h do período de exposição. Os resultados da taxa de sobrevivência celular e a quantidade de danos ao DNA foram estatisticamente analisados pelo teste de Kruskal-Wallis (p<0,05). A citotoxicidade em relação ao grupo controle decresceu na seguinte ordem EndoREZ > Copaíba ≥ AH Plus > RoekoSeal. A formação de micronúcleos (MN) para indicar a genotoxicidade foi induzida somente pelos extratos do EndoREZ, sendo mais genotóxico que o EMS (controle positivo) / Endodontic sealers could release toxic components that may interact with periapical tissues. The purpose of this study was to evaluate the cytotoxicity and genotoxicity of four endodontic sealers (EndoREZ, RoekoSeal, AHPlus and experimental root canal sealer- based on Copaifera multijuga oil-resin) using routine cell biology techniques. The sealers were mixed and incubated in a humidified incubator at 37°C with 5% CO2 in air for 24 h. The exposure of the culture medium to the sealers occurred after 12 h of cure. V79 cells were exposed to dilutions of this extracts for 24 h and cell survival was measured photometrically. The cell viability was measured by MTT test in a spectrophotometer and the genotoxicity as indicated by the formation of micronuclei was determined after a 24 h exposure period The results of the cell survival rates and the amount of DNA damage was statistically analyzed for Kruskal-Wallis (p<0.05) test. The ranking of cell survival from the most to the least toxic material was: EndoREZ> Copaíba ≥ AH Plus > RoekoSeal. The formation of micronuclei (MN) to indicate genotoxicity was induced only by extracts of EndoREZ, being more genotoxic than EMS (positive control)

Page generated in 0.0821 seconds