Influência do cloreto de cálcio no tempo de presa, solubilidade, desintegração, pH e atividade antimicrobiana do MTA e do cimento Portland branco com radiopacificador /

Bortoluzzi, Eduardo Antunes. January 2007 (has links)
Resumo: O objetivo deste estudo foi avaliar a influência do acréscimo de 10% de cloreto de cálcio (CaCl2) no tempo de presa, solubilidade, desintegração, pH e atividade antimicrobiana do MTA Branco (MTA) e cimento Portland branco com radiopacificador (CPB). O ProRoot MTA (PRO), com e sem CaCl2, também foi incluído no teste de atividade antimicrobiana. O teste do tempo de presa inicial seguiu a especificação #57 da ADA e o do tempo de presa final a da ASTM (C266-03). Para os testes de solubilidade, desintegração e pH foram utilizados 6 anéis de teflon para cada cimento, medindo 4 mm de espessura e 12 mm de diâmetro interno com parede de 2 mm. Depois de preenchidos, os anéis foram mantidos por 24 e 72 h e 7, 14 e 28 dias em água MiliQ, que foi renovada no fim de cada período. Após cada período, os cimentos foram desidratados em dessecador com sílica por 24 h. Foi registrado o peso de cada cimento hidratado e desidratado. O pH da água onde os cimentos permaneceram imersos foi medido por um pHmetro. A atividade antimicrobiana foi avaliada pela técnica da difusão em ágar, empregando o método do poço. Os microrganismos utilizados foram procedentes da ATCC: Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Enterococcus faecalis, Streptococcus mutans, Candida albicans, Staphylococcus epidermidis. O acréscimo do CaCl2 proporcionou uma diminuição de 50% do tempo de presa inicial dos cimentos. Já o tempo de presa final do MTA foi diminuído em 35,5% e o do CPB em 68,5%. Os resultados do teste de solubilidade mostraram que o MTA+CaCl2 absorveu água e não perdeu peso com o passar do tempo, exceto no período de 24 h. O MTA, tanto hidratado quanto desidratado, perdeu peso, mas com valores aceitáveis pela ADA. O CPB apresentou maior solubilidade, a qual foi diretamente proporcional ao tempo de imersão das amostras. Entretanto, o acréscimo do CaCl2 ao CPB diminuiu...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of adding 10% calcium chloride (CaCl2) on the setting time, solubility and dissolution, pH, and antimicrobial activity of white MTA (MTA) and Portland cement with radioopacifier (CPB). ProRoot MTA (PRO) with and without CaCl2 was also included in the antimicrobial activity test. Setting time testing followed the specification #57 of ADA and final setting time testing was made according to C266-03 ASTM standard. Six teflon rings (4 mm thickness, 12 mm internal diameter, 2 mm height) used for the solubility, dissolution, and pH tests were stored in deionized water for 24h, 72 h, 7d, 14d, and 28d, which was renewed at the end of each storage period. After the storage periods, the specimens were dehydrated in a desiccator containing silica gel for 24h. The specimens were weighted before and after dehydration and pH of water was measured using a pH-meter. Antimicrobial activity was evaluated using an Agar well diffusion technique. The following microorganisms were used: Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, Enterococcus faecalis, Streptococcus mutans, Candida albicans, and Staphylococcus epidermidis (ATCC). Adding of CaCl2 yielded a 50% reduction of the initial setting of the cements. Final setting time of MTA cement was reduced approximately 35.5% and CPB's final setting time was reduced by 68.5%. Solubility results have shown that the MTA+ CaCl2 absorbed water and did not lost weight with time, except for the 24h-storage period. Hydrated and dehydrated MTA presented weight loss, but within acceptable limits stated by ADA. CPB presented greater solubility, proportional to the immersion time, i.e., the greater the storage period the greater the weight loss. However, adding CaCl2 to the CPB did not decrease the solubility. Both CPB and CPB+ CaCl2 did not satisfy ADA requirements. (Complete abstract, click electronic access below) / Orientador: Roberto Miranda Esberard / Coorientador: Clovis Monteiro Bramante / Banca: Marco Antônio Hungaro Duarte / Banca: Wilson Tadeu Felippe / Banca: Mario Tanomaru Filho / Banca: Idomeo Bonetti Filho / Doutor
2

Análise da interface adesiva entre cimentos resinosos e diferentes terços da dentina intrarradicular /

Suzuki, Thaís Yumi Umeda. January 2011 (has links)
Orientador: Paulo Henrique dos Santos / Banca: Ana Flávia Sanches Borges / Banca: Wirley Gonçalves Assunção / Resumo: O propósito deste estudo foi avaliar as técnicas de cimentação adesiva de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular, através da resistência de união e avaliação de propriedades mecânicas da interface adesiva. Quarenta dentes humanos unirradiculares foram utilizados neste estudo. Após obturação endodôntica e preparo mecânico dos condutos radiculares, os dentes foram divididos em cinco grupos experimentais (n=8), de acordo com a técnica adesiva adotada para cimentação de pinos de fibra de vidro: Grupo 1: adesivo fotoativado Single Bond 2 + cimento resinoso RelyX ARC; Grupo 2: adesivo dual Excite DSC + RelyX ARC; Grupo 3: adesivo autocondicionante Adper SE Plus + RelyX ARC; Grupo 4: cimento resinoso autoadesivo RelyX Unicem; Grupo 5: cimento resinoso autoadesivo Set. As propriedades mecânicas de dureza e módulo de elasticidade foram mensuradas nas estruturas da interface adesiva em ultramicrodurômetro digital DUH-211. A resistência de união foi mensurada pelo teste de push-out em máquina de ensaio universal nos diferentes terços da dentina intrarradicular (cervical, médio e apical). Os dados de resistência de união e propriedades mecânicas foram submetidos a testes estatísticos de normalidade e analisados pela ANOVA e teste de Fisher ( = 0,05). Os resultados mostraram que as propriedades mecânicas de dureza Martens e módulo de elasticidade dos materiais adesivos e do substrato dentinário são influenciados pela interação dos materiais resinosos utilizados, bem como pela profundidade intrarradicular. O mesmo fenômeno foi observado no teste de resistência de união. Para os materiais resinosos, houve uma tendência de o terço apical apresentar os menores valores das propriedades analisadas, o que poderia conduzir à realização de preparos intrarradiculares mais conservativos / Abstract: The purpose of this study was to evaluate techniques for adhesive cementation of glass fiber posts in different thirds of intra-root dentin, through the bond strength and evaluation of mechanical properties of the adhesive interface components. Forty extracted single-rooted human teeth were used in this study. After endodontic filling and mechanical preparation of root canal, teeth were divided into five groups (n=8), according to the technique adopted for adhesive cementation of glass fiber posts: Group 1: Single Bond 2 light-cured adhesive + RelyX ARC resin cement; Group 2: Excite DSC dual adhesive + RelyX ARC; Group 3: Adper SE Plus self-etch adhesive + RelyX ARC; Group 4: RelyX Unicem self-adhesive resin cement; Group 5: Set selfadhesive resin cement. The mechanical properties of Martens hardness and elastic modulus were measured in the structures of the adhesive interface in a DUH-211 digital ultramicro hardness tester (Shimadzu). Push-out bond strength was measured in a universal testing machine (Emic DL 3000) in different areas of intra-root dentin (cervical, middle and apical). The data of bond strength and mechanical properties were subjected to statistical tests of normality and analyzed by ANOVA and Fisher's test ( =0.05). The results showed that the mechanical properties of Martens hardness and elastic modulus of the adhesive materials and dentin substrate can be influenced by the interaction of the materials, as well as the depth of intraradicular dentin. The same phenomenon was observed in the push-out bonding strength test. There was a tendency of the apical region show the least values of mechanical properties, which could stimulate the use of more conservative intraradicular preparation / Mestre
3

Avaliação de três cimentos resinosos na resistência de união entre dentina e uma cerâmica de zircônia estabilizada por ítria /

Castro, Humberto Lago de. January 2010 (has links)
Resumo: Objetivou-se avaliar a resistência à tração (σ) da união de três sistemas de cimentação resinosa de ativação dual (RelyX ARC, RelyX U100 e Panavia F) entre a dentina e uma cerâmica à base de zircônia estabilizada por óxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície oclusal de 54 terceiros molares humanos hígidos foi exposta e condicionada conforme as instruções de cada cimento. Cinqüenta e quatro blocos cerâmicos foram planificados e sinterizados (6,4 mm x 6,4 mm x 4,8 mm). Após, foram divididos em dois grupos conforme o tipo de tratamento de superfície: jateamento com óxido de alumínio ≤ 50 μm ou silicatização (CoJet, 3M ESPE)(24-28 psi). A cimentação à dentina foi realizada de acordo com as instruções de cada fabricante. Assim, foram constituídos 6 grupos. Os conjuntos foram armazenados em água destilada à 37°C por 24 h e cortados no sentido x e y, 9 corpos de prova (cp) por conjunto foram obtidos em média (área adesiva de ± 1 mm2). Os cp de cada conjunto foram divididos aleatoriamente em 3 condições de armazenagem: ensaio imediato; 60 dias de armazenagem em água destilada (37ºC) e termociclagem (10.000x, 5ºC - 55ºC) (n≥12). O ensaio de resistência adesiva por microtração foi realizado numa máquina de ensaio universal (1 mm/min). Nos grupos imediatos RelyX ARC-silicatização e Panavia Fjateamento apresentaram as médias mais altas de σ (13,9 e 13,0 MPa, respectivamente), seguido do RelyX U100-jateamento (10,2 MPa). Após a termociclagem, o cimento Panavia F-jateamento foi melhor (14,8 MPa) seguido pelo RelyX ARC-silicatização e RelyX U100-jateamento (12,9 e 9,9 MPa, respectivamente). Após a armazenagem por 60 dias, os cimentos se comportaram de forma semelhante, onde os grupos que foram silicatizados demonstraram uma tendência a valores mais elevados de σ (MPa) / Abstract: The aim of this study was to evaluate the bond strength of three dualcured resin cement systems (RelyX ARC, RelyX U100 and Panavia F) to dentin and to an yttria-stabilized zirconia-based ceramic (In-Ceram YZ, Vita Zanhfabrik) after different surface treatments. The occlusal surface of 54 sound human third molars was exposed and conditioned according to the manufacturers' instructions. Fifty-four ceramic blocks were cut (6.4mm x 6.4mm x 4.8mm), flattened and fired. They were divided into two groups according to the type of surface treatment: air-abrasion with ≤ 50μm alumina particles or CoJet system (3M ESPE) (14-28 psi). The cementation procedure followed the instructions of each manufacturer. Thus, there were 6 groups. All teeth-cement-ceramic blocks were stored in 37°C distilled water for 24 hours before cutting into non-trimming specimens (adhesive area= 1 mm²). About nine specimens (sp) were obtained per block (n=27). The specimens of each block were randomly assigned to one of the three storage conditions: dry- immediate test, W60- 60 days of storage (37°C water) and TC- thermocycling (10,000x) (n≥12). The microtensile bond strength test was performed using an universal testing machine (crosshead speed: 1 mm/min). Immediate groups of RelyX ARC-Cojet and Panavia F-air-abrasion presented the highest σ average (13.9 and 13.0 MPa, respectively), followed by RelyX U100-airabrasion (10,2 MPa). After TC, Panavia F-air-abrasion was the best (14.8 MPa) followed by RelyX ARC-Cojet and RelyX U100-air-abrasion (12.9 and 9.9 MPa, repectively). After W60, all the cements behaved similarly, when the groups were treated with Cojet system, tended to higher values of σ (MPa) / Orientador: Alvaro Della Bona / Coorientador: Tarcísio José de Arruda Paes Junior / Banca: Estevão Tomomitsu Kimpara / Banca: Mário Alexandre Coelho Sinhoreti / Mestre
4

Estudo dos mecanismos envolvidos na migração celular induzida pelo MTA para cavidade peritoneal de camundongos /

Gomes, Alessandra Cristina. January 2006 (has links)
Orientador: Sandra Helena Penha de Oliveira / Banca: Carlos Ferreira dos Santos / Banca: Pedro Felício Estrada Bernabé / Resumo: O objetivo deste trabalho foi investigar os mecanismos envolvidos na migração de neutrófilos induzida pelo MTA para cavidade peritoneal de camundongos. Observouse que o MTA induziu migração de neutrófilos de maneira dose-dependente (0,5; 5; 50 e 100 mg/cavidade), alcançando o pico de migração 6 horas após a injeção do estímulo com a dose de 50 mg/cavidade. Esta migração foi parcialmente inibida pelo pré-tratamento dos animais com dexametasona (1 mg/Kg), BWA4C (50 mg/Kg) e U75302 (0,5 mg/Kg). Diferentemente, a Indometacina (5 mg/Kg) foi inefetiva neste processo. Verificou-se também que os animais estimulados com MTA (50 mg/cavidade) apresentaram uma liberação significativa de IL-1ß e MIP-2 no exsudato peritoneal. O pré-tratamento com Tioglicolato aumentou em cerca de 380% a população de macrófagos na cavidade peritoneal, potencializando a migração de neutrófilos induzida pelo MTA (p<0,05). O pré-tratamento com composto 48/80 depletou cerca de 75% a população de mastócitos, diminuindo a migração de neutrófilos (p<0,05). A injeção de MTA na bolha de ar subcutânea induziu uma migração de neutrófilos menor comparada à cavidade peritoneal. Estes resultados confirmam a participação de mastócitos e macrófagos na migração de neutrófilos induzida pelo MTA. A injeção de sobrenadante de macrófagos e mastócitos estimulados com MTA na cavidade peritoneal de camundongos causou significante migração de neutrófilos (p<0,05), que foi parcialmente inibida pelo pré-tratamento das células por dexametasona (10 æMolar), BWA4C (100 æMolar) e U75302 (10 æMolar) sugerindo a liberação por essas células de LTB4 e citocinas e/ou quimiocinas. Confirmando esses dados,...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to investigate the mechanism involved in the neutrophil migration induced by MTA into peritoneal cavity in mice. It was observed that MTA induced a dose dependent neutrophil migration (0.5, 5, 50 and 100 mg/cavity), achieving the peak 6 hours after the stimulation with 50 mg/cavity. Neutrophil migration was inhibited by the pre-treatment with dexamethasone (1 mg/Kg), BWA4C (50 mg/Kg) and U75302 (0,5 mg/Kg). Differently indometacin (5 mg/Kg) was ineffective in this process. It was seen that the animals stimulated with MTA (50 mg/cavity) showed a significative amount of IL-1ß and MIP-2 released to the peritoneal exudate. The pretreatment with Thioglycolate 3% increased 380% the macropahge population into the peritoneal cavity, increasing the MTA-induced neutrophil migration (p<0.05). The pretreatment with 48/80 compound decreased 75% the mast cell population in the peritoneal cavity and decreased the MTAinduced neutrophil migration (p<0.05). The injection of MTA in the air-pouch cavity induced a neutrophil migration, however, the recruitment was shorter than that induced into the peritoneal cavity. These data confirm the participation of the mast cell and macrophages in the MTA-induced neutrophil migration. The injection of MTA-stimulated macrophages and mast cells supernatants into the mice peritoneal cavity induced a significant neutrophil migration that was inhibited by the pretreatment with dexamethasone (10 æMolar), BWA4C (100 æMolar) and U75302 (10 æMolar) suggesting the release of LTB4 and cytokines and/or chemokines by these cells. Besides, macrophages and mast cells MTA-induced were able to express in vitro IL-1ß MIP-2 and 5-LO mRNA. In conclusion, the neutrophil migration into mice peritoneal cavity induced by MTA was dependent on mast cells and macrophages, which expressed IL-1ß, MIP-2 and LTB4. / Mestre
5

Efeitos citotóxicos de diferentes materiais dentários sobre células de linhagem odontoblástica /

Mendonça, Adriano Augusto Melo de. January 2005 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: José Mauro Granjeiro / Banca: Welington Dinelli / Resumo: A presente pesquisa avaliou o efeito citotóxico de diferentes materiais dentários sobre células de linhagem odontoblástica MDPC-23 em cultura. Para isto, corpos-de-prova com dimensões de 4mm de diâmetro e 2 mm de profundidade foram confeccionados com os seguintes materiais: hidróxido de cálcio (Hydro C - Grupo HCa); RelyX Luting (Grupo RL); Vitrebond (Grupo VB); e RelyX Unicem (Grupo RU). Cada espécime foi imerso em meio de cultura não suplementado com soro fetal bovino (MC-SFB) e incubado pelos períodos de 24 horas ou 7 dias. Células odontoblastóides MDPC-23 foram semeadas (3x104 células/cm2) em pratos de acrílico com 24 compartimentos e incubados por 72 horas, sendo que após este período, o meio de cultura completo (DMEM) foi substituído pelos extratos obtidos de cada material experimental. Após incubação adicional de 24 horas, a atividade da enzima desidrogenase succíninca das células foi avaliada através do teste de MTT. No grupo controle, o meio de cultura foi substituído pelo MC-SFB fresco (sem tratamento). Para os períodos de 24 horas, os grupos HCa, RL, VB e RU apresentaram valores de redução no metabolismo celular de 91,52%; 78,17%; 89,14%; e 2,64%, respectivamente, quando comparados com o grupo controle (DMEM), o qual não reduziu o metabolismo celular. Com relação ao período experimental de 7 dias, os valores de redução na atividade metabólica para os grupos HCa, RL, VB e RU foram de 91,13%, 79,04%, 87,27% e 10,51%, respectivamente. Segundo a análise estatística de Kruskall-Wallis complementada pelo teste de Mann-Whitney não houve diferença entre os grupos HCa e VB, os quais foram os materiais mais citotóxicos em ambos os períodos avaliados. RU foi o cimento menos tóxico, sendo que não houve diferença estatisticamente significante com o grupo controle no período de 24 horas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present in vitro study evaluated the cytotoxic effects of different dental materials on the odontoblast-like cells MDPC-23. For this purpose, round samples (2-mm thick and 4-mm in diameter) were prepared with the following experimental materials: calcium hydroxide (Hydro C - Group HCa); RelyXTM Luting Cement (Group RL); Vitrebond (Group VB); and RelyXTM Unicem (Group RU). The samples were placed in fresh culture medium with no fetal bovine serum (DMEM-FBS) and incubated for 24 hours or 7 days at 37°C with 5% CO2, and 95% air. The odontoblast cells were plated (3x104 cells/cm2) in wells of five 24-wells dishes and incubated for 72 hours. After this period, the complete culture medium (DMEM) was replaced by the extracts obtained from every sample. The cells in contact with the extracts were incubated for additional 24 hours. The MTT Assay was carried out to evaluate the cell metabolism. In control group (DMEM) the nontreated fresh culture medium (DMEM-FBS) was applied on the cultured cells. At 24 hours period, the experimental materials HCa, RL, VB and RU decreased the mitochondrial respiration by: 91,52%; 78,17%; 89,14%; and 2,64%, respectively. At 7 days, the reduction of the cell metabolism for groups HCa, RL, VB and RU was: 91,13%; 79,04%; 87,27%; and 10,51%, respectively. The statistical analysis of Kruskal-Wallis complemented by the Mann-Whitney test demonstrated there was no statistical difference between the groups HCa and VB which presented the highest cytotoxic effects on the MDPC-23 cells. On the other hand, no difference statistically significant was observed between RU and DMEM, at 24 hours period. The ranking of cytotoxicity observed at 24 hours and 7 days was: HCa=VB>RL>RU=DMEM and HCa=VB>RL>RU>DMEM, respectively. Based upon the scientific data presented in this in vitro study, it was concluded... (Complete abstract, click electronic address below). / Mestre
6

Avaliação qualitativa e quantitativa da resposta tecidual frente aos cimentos: MTA Ângelus cinza e MTA fotopolimerizável experimental : análise microscópica de implantes realizados em subcutâneos de ratos /

Faria, Max Douglas. January 2006 (has links)
Orientador: João Eduardo Gomes Filho / Banca: Francisco José de Souza Filho / Banca: Pedro Felício Estrada Bernabé / Resumo: A necessidade de preservar a integridade do dente sucessor permanente, em formação, na vigência do tratamento endodôntico dos dentes decíduos, tem estimulado o estudo de vários tipos de cimentos endodônticos, dentre eles o MTA. Este trabalho teve a finalidade de avaliar quantitativamente e qualitativamente a resposta inflamatória frente ao implante de tubos de polietileno e de dentina em subcutâneo de ratos, contendo, o cimento experimental desenvolvido pela Northwestern Universiy Medical School, de Chicago USA, em parceria com a empresa de materiais odontológicos Bisco comparando-o ao MTA Ângelus cinza. Foram utilizados 36 ratos, divididos em seis grupos. No grupo 1, tubos de polietileno vazios foram introduzidos no subcutâneo dos ratos para serviriam de controle para os grupos experimentais. No grupo 2 foram implantados tubos de polietileno contendo o cimento MTA Ângelus®. No grupo 3, tubos de polietileno contendo o cimento experimental fotopolimerizavel foram implantados. No grupo 4, tubos de dentina contendo MTA Angelus® foram implantados. No grupo 5, tubos de dentina contendo o cimento experimental fotopolimerizavel foram implantados. No grupo 6 tubos de dentina vazios foram implantados. Após 30 e 60 dias os animais foram sacrificados e os tubos de polietileno juntamente com o tecido que o circundava foram removidos e processadas para analise em microscopia de luz, com inclusão em parafina, cortes seriados de 6mm e coloração por HE. Os tubos de dentina foram removidos após 30 dias e processados para analise em microscopia de luz, com inclusão em cera de carnaúba, cortes seriados de 10mm e coloração de Van Kossa. Observou-se resultados mais favoráveis com MTA Ângelus®, pois o MTA experimental demonstrou resposta inflamatória de maior intensidade. / Abstract: The need of preserving the integrity of a permanent successor tooth, the development on the validity of deciduous endodontic tooth, has leading to the study of several kinds of endodontic materials, such as the MTA. This study means to evaluate quantitatively and the qualification of the inflammatory response to the polyethylene and dentine tubes implants on rat's subcutaneous, containing, the experimental cement developed by Northwestern University Medical School, in Chicago USA, in association to Bisco dental material company comparing it to MTA Ângelus® gray. It was used 36 rats, divided into six groups. In group 1, empty polyethylene tubes were implanted on rat's subcutaneous as control to the experimental groups. In group 2, it was implanted polyethylene tubes containing MTA Ângelus®. In the group 3, polyethylene tubes containing the experimental cement light cured. In the group 4, dentine tubes containing MTA Ângelus® were implanted. In the group 5, dentine tubes containing the experimental cement light cured were implanted. In the group 6, empty dentine tubes were implanted. After 30 to 60 days the animal were sacrificed and the implanted polyethylene tubes and surrounding tissue were removed and processed in laboratory to analyses on light microscopy, with embedding in paraffin, cut with 6mm thickness and stained with HE. The dentine tubes were removed at the same way 30 days after implantation and processed in laboratory to analyses on light microscopy, with embedding in carnauba wax, cut with 10mm thickness without demineralization and stained with Von Kossa. It was observed favorable results to MTA Ângelus® and experimental material showed higher levels on the inflammatory process. Besides, MTA Ângelus® was the only material to show positive area of mineralization with Von Kossa staining. / Mestre
7

Efeito de tratamento de superfície do titânio comercialmente puro na resistência de união com cimentos ionomérico e resinosos /

Abi Rached, Filipe de Oliveira. January 2011 (has links)
Orientador: Renata Garcia Fonseca / Banca: Gelson Luis Adabo / Banca: Paulo Francisco Cesar / Resumo: O titânio, em virtude de suas atrativas propriedades, foi introduzido na área de reabilitação oral podendo ser indicado para a confecção de restaurações metalocerâmicas dento- ou implanto-suportadas. No entanto, apresenta dificuldade de união com materiais resinosos, o que poderia comprometer a longevidade dessas restaurações, considerando a importância da qualidade de união na interface metal/cimento. Para contornar este problema, pode-se lançar mão de tratamentos de superfície do titânio, empregados isoladamente ou em associação. Este estudo avaliou a eficácia de diferentes tratamentos de superfície na resistência ao cisalhamento (RC) da união do cimento ionomérico modificado por resina RelyX Luting 2 e dos cimentos resinosos RelyX ARC e RelyX U100 ao titânio comercialmente puro (Ti cp). Duzentos e quarenta discos (9 x 3 mm) foram fundidos em Ti cp, incluídos em tubos de PVC e regularizados com lixas de carbeto de silício (150, 400 e 600) em politriz. Os espécimes foram divididos aleatoriamente em oito grupos (n=30), os quais receberam um dos seguintes tratamentos de superfície: (1) Al2O3 50 μm; (2) Al2O3 120 μm; (3) Al2O3 250 μm; (4) Al2O3 50 μm + silano; (5) Al2O3 120 μm + silano; (6) Al2O3 250 μm + silano; (7) Cojet Sand (30 μm) + silano; (8) Al2O3 120 μm + Rocatec (110 μm) + silano. Os cimentos (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 foram aplicados às superfícies tratadas do Ti cp (n=10). Os espécimes foram termociclados (5.000 ciclos, 5 e 55 °C, 30 segundos de imersão) e, então, submetidos ao ensaio de cisalhamento (0,5 mm/min). O modo de fratura foi avaliado em estereomicroscópio (x20). Os dados foram analisados por ANOVA 2 fatores e teste de Tukey (α=0,05). Os cimentos RelyX Luting 2 e RelyX U100 apresentaram comportamento semelhante com relação ao tratamento de superfície... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium was introduced in the field of oral rehabilitation because of its attractive properties, as it can be indicated for fabricating tooth- or implant-supported metal ceramic restorations. However, difficulties have been shown to exist as regards the bond between resin-based materials and titanium, which could compromise the longevity of these restorations, considering the importance of the bond quality at the metal/cement interface. To overcome this problem, titanium surface treatments can be applied alone or they can be combined with each other. This study evaluated the efficacy of different surface treatments on the shear bond strength (SBS) of RelyX Luting 2 resin-modified glass ionomer cement, RelyX ARC and RelyX U100 resin cements to commercially pure titanium (CP Ti). Two hundred and forty discs (9 x 3 mm) were cast from CP Ti, embedded in PVC tubes and smoothed with silicon carbide papers (150, 400 and 600) using a polisher. Specimens were randomly divided into 8 groups (n=30), which received one of the following surface treatments: (1) 50 μm Al2O3; (2) 120 μm Al2O3; (3) 250 μm Al2O3; (4) 50 μm Al2O3 + silane; (5) 120 μm Al2O3 + silane; (6) 250 μm Al2O3 + silane; (7) Cojet Sand (30 μm) + silane; (8) 120 μm Al2O3 + Rocatec (110 μm) + silane. The luting cements (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 were applied to the treated CP Ti surfaces (n=10). Specimens were thermal cycled (5,000 cycles, 5 and 55 °C, 30-second dwell time), and afterwards submitted to SBS testing (0.5 mm/min). Failure mode was evaluated under a stereomicroscope (x20). Data were analyzed using 2-way ANOVA and Tukey's test (α=0.05). The RelyX Luting 2 and RelyX U100 luting cements exhibited similar behavior regards to the surface treatment. For both, only the group abraded with 50 μm Al2O3 particles promoted lower SBS than the other groups (P>.05)... (Complete abstract click electronic access below) / Mestre
8

Resistência de união cerâmica - agente cimentante. Teste de micro-tração e análise por microscopia eletrônica de varredura

Faria, Ricardo Pinheiro de. January 2004 (has links)
Orientador: Leonor de Castro Monteiro Loffredo / Banca: Celso Luiz de Angelis Porto / Banca: Camila Pinelli / Banca: Rubens Corte Real de Carvalho / Banca: Adair Luis Stefanello Busato / Resumo: Os objetivos deste trabalho foram avaliar a influência de diferentes tempos de condicionamento ácido na resistência de união cerâmica-agente cimentante, por meio do teste de Micro-Tração, bem como análise dos modos de fratura. Foram confeccionados 5 pares de discos de cerâmica de infra-estrutura IPS Empress 2 e divididos aleatoriamente em 5 grupos. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação seqüencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: G1: sem condicionamento ácido; G2: 20 s de condicionamento com ácido fluorídrico a 10%; G3: 40 s e condicionamento com ácido fluorídrico a 10%; G4: 60 s de condicionamento com ácido fluorídrico a 10% e G5: 2 min de condicionamento com ácido fluorídrico a 10%. Os espécimes, aos pares, foram cimentados com um sistema adesivo e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 h a 37°C e, posteriormente, com auxílio de um disco de diamante perpendicular à superfície de união, "palitos" com 1 mmø de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS 800) e submetidos à análise de variância e teste de Tukey. As médias de resistência foram de 30,20 MPa, 36,19 MPa, 38,72 MPa, 41,43 MPa e 42,53 MPa, respectivamente aos grupos G1, G2 G3 G4 e G5. O grupo G1 apresentou menor resistência média de união do que os demais grupos. O grupo G3 teve comportamento semelhante a G2 e a G4, porém estes dois últimos foram diferentes entre si. Os grupos G4 e G5 promoveram resistências médias semelhantes. Concluímos que o aumento do tempo de condicionamento ácido aumentou os valores de resistência de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The purpose of this study was to investigate the effect of different times of acid conditioning on the microtensile bond strength between union-cement and ceramic, and to verify the mode of failure. Five pairs of ceramic disks (IPS Empress 2) were divided, in five groups, by randomized allocation. The bonding surfaces were finished with 600-grit silicon carbide paper. The specimens were nominated at random and submitted to the following treatments before cementation: G1 : without acid etching; G2 : 20 s of etching with 10% hydrofluoric acid; G3 : 40 s of etching with 10% hydrofluoric acid; G4 : 60 s of etching with 10% hydrofluoric acid and G5 : 2 min of etching with 10% hydrofluoric acid. All the pairs were bonded with dual cure resin bonding and dual cure resin cement, according to manufacturer's instructions. The specimens were light-cured and then stored for 48 h at 37°C. Using a diamond disk perpendicular to the bonding interface, 'sticks' with 1.0 mmø cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. It was applied analysis of variance and Tukey test at p<0.05. The means of microtensile bond strength, in MPa, were 30.20, 36.19, 38.72, 41.43 and 42.53, respectively to the groups G1, G2, G3, G4 and G5. Group G1 had the smallest microtensile bond strength and G3 had similar results when compared to G2 and G4, although G2 and G4 were different between themselves. The groups G4 and G5 showed similar means of microtensile bond strength. Conclusions: The higher the time of acid conditioning higher were the values of microtensile bond strength, and the analysis of mode of failure exhibited prevalence of adhesive failure type. / Doutor
9

Avaliação da eficiência de adesão de um cimento resinoso autocondicionante (self-adhesive) sobre esmalte e dentina : efeito termociclagem e condicionamento dental : estudo in vitro /

Fernandes Júnior, Virgílio Vilas Boas. January 2010 (has links)
Orientador: José Roberto Rodrigues / Banca: Carlos Augusto Pavanelli / Banca: José Claudio Martins Segalla / Resumo: O objetivo do trabalho foi analisar in vitro a eficiência de adesão através de ensaio de microtração, de um cimento autocondicionante (self-adhesive), sobre esmalte e dentina, com e sem tratamento prévio da superfície dental, antes e após termociclagem. Foram utilizados 56 terceiros molares, 28 para esmalte e 28 para dentina, divididos em 6 grupos experimentais e 2 controle. O cimento resinoso autocondicionante selecionado para os grupos experimentais foi: Rely-X Unicem (3M ESPE/ St. Paul, MN, EUA), e para os grupos controle o Variolink II (Ivoclar Vivadent, AG, Schaan, Liechtenstein) (VR), cimento de cura dual não autocondicionante. Os dentes dos grupos experimentais foram subdivididos quanto à aplicação direta do cimento sobre a superfície dental (R), com o condicionamento ácido (RAC) e com condicionamento ácido e aplicação de sistema adesivo (RACAS). Blocos de resina composta previamente polimerizados foram cimentados à superfície dental. Os conjuntos dente-cimento-bloco receberam cortes paralelos ao longo eixo dos dentes para a confecção dos palitos. O ensaio de microtração com aparelho de ensaio universal (EMIC) foi utilizado para analisar a resistência adesiva dos cimentos avaliados. Os corpos de prova após o ensaio foram analisados mediante microscópio óptico para analise do modo de fratura. Para a análise estatística do μTBST, foi utilizado ANOVA 3 fatores com teste de comparação múltipla de Tukey a 5%, considerando os fatores cimento resinoso, região e armazenagem. Os resultados mostraram diferença estatística existente entre R aplicado diretamente sobre a superfície dental e os demais grupos. Os grupos RACAS e VR apresentaram maiores médias de resistência adesiva para os grupos dentina, respectivamente antes e após termociclagem e o cimento RAC para os grupos esmalte. A termociclagem não diminuiu significativamente os valores de resistência... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this research was to analyze in vitro , the adhesive efficiency of a self - etching cement trough microtensile test , over enamel and dentine , with and with out previous treatment of dental surface , before and after thermocycling. Were used 56 third molars, 28 for enamel and 28 for dentine, divided in 06 experimental groups and 02 control groups. The resin cement self - etching selected for the experimental groups was: Rely X Unicem (3M ESPE/ St. Paul, MN, EUA), and for the control groups: Variolink II (Ivoclar Vivadent, AG, Schaan , Liechtenstein) (VR), dual healing cement not self etching. The teeth of the experimental groups were subdivided in groups as the direct application of cement over the dental surface (R) without previous treatment (RAC), with the acid etching and with acid etching and application of adhesive system (RACAS) e (VR). Composed resin blocks polymerized previously were cemented on dental surface. The sets tooth- cement-block received parallel cuts in long axis of the teeth to make the tooth picks. The micro tensile test was done with the universal apparatus (EMIC) to analyze the resistance efficiency of the evaluated cements. The specimens were analyzed after the test by optical microscope to analyze the mode fracture. For the statistics analyses of μTBST, were used ANOVA 3 factors with multiple comparison test of Tukey 5%, considering the factors resin cement, region and storage. The results showed present statistics difference between R applied directly on dental surface and the other groups. The groups RACAS and VR presented superior average of adhesive resistance for dentine groups before and after thermocycling, and the RAC cement for the enamel groups before and after thermocycling. The thermocycling did not low significantly the adhesive resistance values, just for the RACAS group. By the results we can conclude that the self etching... (Complete abstract click electronic access below) / Mestre
10

Avaliação da resistência à remoção por tração de coroas metálicas fixadas com cimentos resinosos e da dureza desses materiais em função do método de ativação /

Fonseca, Renata Garcia. January 2001 (has links)
Orientador: Carlos Alberto dos Santos Cruz / Banca: Gelson Luis Adabo / Banca: Luís Geraldo Vaz / Banca: Rosehelene Marotta Araújo / Banca: Adriana Cristina Zavanelli / Resumo: Foram avaliados grau de polimerização de cimentos resinosos em função de diferentes intensidades de luz, por meio de ensaio de dureza, e resistência à remoção por tração de coroas cimentadas em troquéis com determinados cimentos. A primeira etapa foi realizada submetendo-se ou não os cimentos resinosos Panavia F, Scothbond Resin Cement, Enforce e Cement-It à fotoativação, tendo as leituras sido realizadas nos tempos imediato, 1 hora, 2 horas, 24 horas e 7 dias após espatulação dos materiais. No segundo ensaio, foram confeccionados troquéis e coroas, ambos em liga de NiCr, os quais, após jateamento e aplicação do agente catalisador do sistema adesivo Scotchbond Multi Uso Plus (3M) em suas superfícies, foram cimentados aos pares com os materiais descritos anteriormente, além do cimento de fosfato de zinco. A análise dos resultados revelou que os cimentos resinosos alcançaram maior dureza nos grupos fotoativados em todos os tempos analisados, com exceção apenas do Scotchbond Resin Cement e Enforce que, aos 7 dias, mostraram igualdade estatística entre os tratamentos. Todos os materiais apresentaram progressão de polimerização em função do tempo na ausência de luz, com diferentes velocidades. Os cimentos Panavia F e Fosfato de Zinco apresentaram, respectivamente, a maior e a menor força de remoção por tração, tendo o Scotchbond Resin Cement, Enforce e Cement-It ficado em posição intermediária, diferenciando-se significativamente dos demais materiais, porém não entre si. / Abstract: The purpose of this study was to evaluate plymerization degree of resin cements subjected to various light exposures, by hardness test, and bond strength of crowns luted to dies using five luting agents. Panavia F, Scothbond Resin Cement, Enforce and Cement-It were exposed or not to light and measurements were taken at baseline, 1 hour, 1 hours and 7 days after mixing. For the second evaluation, dies and crowns were obtained with NiCr alloys and after sandblasting and treatment with catalyzer agent of Scotchbond Multi Uso Plus adhesive system (3M) at both surfaces, cementation was done with the luting agents described before, besides zinc phosphate cement. Statistical analysis revealed greater hardness for photopolymerized groups in all times, excepting Scotchbond Resin Cement and Enforce that, at 7 days, showed no statistical difference between treatments. All cements had polymerization progression with time at light absence, with different speeds. Panavia F and zinc phosphate showed, respectively, the greatest and smallest bond strength, while Scotchbond Resin Cement, Enforce and Cement-It were in a intermediate position, differing significantly of the other cements, but not between theirserlves. / Doutor