• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 16
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da resistência de união entre dentes artificiais e resinas acrílicas para base protética. Efeito de termociclagem /

Marra, Juliê. January 2007 (has links)
Orientador: Marco Antonio Compagnoni / Banca: Débora Barros Barbosa / Banca: Renata Garcia Fonseca / Resumo: O estudo avaliou a resistência de união entre dentes artificiais e resinas acrílicas para base protética e o efeito da termociclagem. Para isso foram utilizadas três marcas comerciais de dentes artificiais de resina acrílica (Biotone, Trilux e Ivoclar) e quatro de resinas acrílicas para base protética, sendo duas termopolimerizáveis por banho de água quente (Lucitone 550 e QC-20), uma polimerizada por meio da energia de microondas (Acron MC) e uma fotopolimerizável (Versyo.com). Vinte espécimes foram confeccionados para cada combinação de dente artificial e resina acrílica e divididos em 2 grupos (n=10) nas seguintes condições experimentais: sem a ação da termociclagem (grupo controle) e com a ação da termociclagem. Os espécimes dos grupos com termociclagem foram submetidos 5000 ciclos com temperatura variando entre 4º e 60ºC e tempo de imersão de 30 segundos em cada. Em seguida, os espécimes foram submetidos ao ensaio mecânico de cisalhamento em máquina universal a uma velocidade de 1mm/min. Os dados foram submetidos à análise de variância a três fatores seguida pelo teste de Bonferroni para comparações múltiplas (a=0,05). Os resultados demonstraram que a termociclagem reduziu significantemente os valores médios de resistência de união da resina acrílica Lucitone 550 quando associada aos dentes Biotone e Trilux e com a resina Versyo.com e os dentes Ivoclar P<0,05). E que as médias de resistência de união das resinas acrílicas Acron MC e Lucitone 550 quando associadas aos dentes Ivoclar aumentaram significantemente após a ação da termociclagem (P<0,05). Conclui-se que algumas combinações de dente artificial e resina acrílica podem ser mais afetadas pela ação da termociclagem, e esses efeitos variam de acordo com os materiais selecionados. / Abstract: The purpose of this in vitro study was to evaluate the bond strength of denture base resins to acrylic denture teeth and the effect of the thermocycling. Three acrylic denture teeth (Biotone, Trilux and Ivoclar) were chosen for bonding to four denture base resins: one microwave-polymerized (Acron MC), two heat-polymerized (Lucitone 550 and QC-20) and one light-polymerized (Versyo.com). Twenty specimens were produced for each denture base/acrylic denture tooth combination and were divided into 2 groups (n=10) as follows: without thermocycling (control groups) and thermocycled groups that were submitted to 5,000 cycles between 4º and 60ºC with a dwell time of 30 seconds in each bath. Shear strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 1 mm/min until fracture. Statistical analysis of the results was carried out with 3-way ANOVA and Bonferroni's multiple comparisons post hoc analysis for test groups (a=.05). A significant interaction between denture base resin, acrylic denture teeth and thermocycling (P<.001) was observed. The shear bond strengths of Lucitone 550/Biotone, Lucitone 550/Trilux and Versyo.com/Ivoclar specimens were significantly decreased by thermocycling compared with the corresponding control groups (P<.05). The shear bond strengths of Acron/Ivoclar and Lucitone/Ivoclar specimens significantly increased after thermocycling (P<.05). Some acrylic tooth/denture base resin combinations can be more affected by thermocycling; the effects vary based upon the materials used. / Mestre
2

Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese /

Azevedo, Andréa. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Eunice Teresinha Giampaolo / Banca: Cláudio Rodrigues Leles / Resumo: Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below) / Mestre
3

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável /

Gonçalves, Alessandro Ribeiro. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Carlos Eduardo Vergani / Banca: João Neudenir Arioli Filho / Banca: Arlindo Abreu de Castro Filho / Banca: Eduardo Miyashita / Resumo: Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below) / Doutor
4

Resistência adesiva de bráquetes ortodônticos colados com sistemas adesivos convencionais e auto-condicionantes ao esmalte bovino após ciclos térmicos e termomecânicos /

Torres, Luciana Marcondes Sarmento. January 2011 (has links)
Orientador: Rebeca Di Nicoló / Banca: Clovis Pagani / Banca: Daniela Raggio / Resumo: Este estudo in vitro teve como objetivo avaliar a influência das ciclagens térmica e termomecânica na resistência adesiva de bráquetes colados em esmalte bovino com primers convencionais e auto-condicionates. Noventa incisivos bovinos foram aleatoriamente divididos em 2 grupos (G), de acordo com o primer utilizado: XT (n=45) - bráquetes colados com primer convencional (Transbond XT/3M, Unitek); SEP (n=45) - bráquetes colados com primer auto-condicionante (Transbond Plus SEP/3M, Unitek). Após a colagem dos bráquetes, cada grupo foi subdividido em 3 subgrupos (n=15): SC (sem ciclagem) - as amostras não receberam nenhum tipo ciclagem; CT (ciclagem térmica) - as amostras receberam apenas ciclagem térmica (500 ciclos de 50C a 550C); CTM (ciclagem termomecânica) - as amostras receberam ciclagem termomecânica (100.000 ciclos de 50C a 550C). A seguir, foi realizado o teste de cisalhamento em uma máquina de ensaios universal (EMIC) a uma velocidade de 1mm/min com célula de carga de 100kg. Após o descolamento dos bráquetes, amostras de cada grupo foram submetidas à avaliação microscópica em microscópio eletrônico de varredura, a fim de analisar a superfície do esmalte e quantificar o Índice de Adesivo Remanescente (IAR) sobre a superfície. Os resultados mostraram que o grupo SEP apresentou maior resistência adesiva (14,70±4,85 MPa) quando comparado com o grupo XT (11,27±4,48 MPa). Para os grupos XT, a resistência adesiva manteve-se semelhante independente do tipo de ciclagem (SC, 11,44 MPa; CT, 11,20 MPa; CTM,11,19 MPa), enquanto que para os grupos SEP o subgrupo CTM foi o que apresentou maiores valores de resistência adesiva (16,84 MPa), seguido do CT (14,99 MPa) e SC (12,26 MPa). O teste ANOVA - 2 fatores revelou que o efeito interação não é estatisticamente significante; indicando, assim, que o efeito do tipo de ciclagem para o grupo XT é o mesmo ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this in vitro study was to evaluate the influence of thermal and thermomechanical cycling on shearbond strength of orthodontic brackets bonded with conventional and self-etching primers. 90 bovine incisors were randomly divided into 2 groups (G) according to the primer: XT (n=45) - brackets bonded with conventional primer (Transbond XT/3M, Unitek); SEP (n=45) - brackets bonded with self-etching primer (Transbond Plus SEP/3M, Unitek). After bonding, each group were divided into 3 subgroups (n=15): NC (no cycling) - the specimens did not receive any kind of cycling; TC (thermal cycling) - the specimens received only thermal cycling (500 cycles); TMC (thermomechanical cycling) - the specimens received thermomechanical cycling (100.000 cycles). Next, the shearbond strength test was performed in a universal testing machine (EMIC) at a crosshead speed of 1mm/min. After debonding, specimens of each group were submitted to microscopic evaluation in order to analyze the enamel surface, the adhesive penetration and quantify the Adhesive Remaining Index (ARI). The results showed that the SEP group presented higher bond strength (14,70±4,85 MPa) compared with XT (11,27±4,48 MPa). For XT, the bond strength remained similar despite cycling (NC, 11,44 MPa; TC, 11,20 MPa; TMC,11,19 MPa), meanwhile for SEP, the subgroup TMC showed higher values of bond strength (16,84 MPa), followed by TC (14,99 MPa) e NC (12,26 MPa). 2-way ANOVA test indicated that the interaction effect is not statistically different, so the kind of cycling effect for XT is equal for SEP. But the primer effect (XT vs SEP) is statiscally significant. According to the ARI , the group that presented the highest remaining adhesive on the enamel surface was SEP/TMC (ARI=3). The results showed that self-etching primers can be safely used in orthodontic practice because presents adequate values of bond strength ... (Complete abstract click electronic access below) / Mestre
5

Avaliação da resistência ao cisalhamento de sistemas para reparo em metalocerâmicas. Efeito do armazenamento em água /

Haneda, Isabella Gagliardi. January 2007 (has links)
Orientador: Renata Garcia Fonseca / Banca: Carlos Alberto dos Santos Cruz / Banca: Mauro Antonio de Arruda Nobilo / Resumo: O reparo de restaurações metalocerâmicas fraturadas pode ser considerado um desafio, principalmente quando grande quantidade de metal é exposta. O estabelecimento de uma união forte e durável entre material reparador e substrato da restauração fraturada é essencial para o sucesso do reparo. Este estudo avaliou a resistência ao cisalhamento entre diferentes sistemas de reparo e liga de NiCr e a durabilidade desta união após armazenamento em água por um longo período. Foram confeccionados 100 discos (9 OE 3 mm) em liga de NiCr. Esses foram incluídos em anel de PVC com resina acrílica e tiveram suas superfícies regularizadas com lixas (120, 220 e 320) em politriz. Cada espécime recebeu um dos seguintes tratamentos: 1) Clearfil SE Bond, 2)Bistite II DC, 3)Cojet, 4) Scotchbond Multi Uso Plus (Grupo controle), e 5) uma variação do Grupo controle, na qual foram empregadas partículas de sílica do sistema Cojet Sand em substituição às de óxido de alumínio. Os espécimes foram armazenados água destilada a 37ºC por 24 horas, termociclados (1.000 ciclos - 5º e 55ºC) e, então, armazenados nas mesmas condições descritas anteriormente, por um período adicional de 24 horas ou 6 meses. O ensaio de cisalhamento foi realizado em máquina de ensaios Material Test System 810 com velocidade de 0,5 mm/minuto. Para cada período de armazenamento, os resultados foram analisados por meio de análise de variância (ANOVA) e teste de Tukey. Para cada sistema, os valores obtidos às 24 horas foram comparados aos encontrados após 6 meses empregando-se teste t de Student não pareado. (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: When clinical fractures of metal-ceramic prostheses occur, exposing the metal substructure, repair may be considered a challenge. The clinical success of repair depends on establishing a strong and long-term durable bond between the repair material and the metal surface of the failed restoration. This study evaluated shear bond strength of different repair systems to NiCr alloy and bond durability after long-term water storage. One hundred cylindrical specimens (9 OE 3 mm) were fabricated in a nickel-chromium alloy. The NiCr cylinders were embedded in a PVC ring and all specimen bonding surfaces were smoothed with silicon carbide papers (120, 220, and 320 grit) using a polisher. Specimens were divided into 5 groups of 20, which received one of the following bonding and resin composite repair systems (n=10): 1) Clearfil SE Bond/Clearfil AP-X, 2) Bistite II DC/Palfique, 3) Cojet /Z100, 4) Scotchbond Multipurpose Plus /Z100 (control group), and 5) Cojet Sand plus Scotchbond Multipurpose Plus /Z100. The specimens were stored in distilled water for 24 hours at 37ºC, thermal cycled (1,000 cycles - 5º to 55ºC) and stored in distilled water at 37ºC for either 24 hours or 6 months. Shear bond tests were performed in a mechanical testing machine with a crosshead speed of 0.5 mm/minute. Data (MPa) were analyzed using 1-way ANOVA and Tukey HSD test (a=.05) for each storage time. The results obtained at 24 hours for each repair system were compared with those found at 6 months using Student's t-test. Each specimen was examined under a stereoscopic lens with OE30 magnification, and mode of failure was classified as adhesive, cohesive or combination. (Complete abstract, click electronic access below) / Mestre
6

Efeito de tratamento de superfície do titânio comercialmente puro na resistência de união com cimentos ionomérico e resinosos /

Abi Rached, Filipe de Oliveira. January 2011 (has links)
Orientador: Renata Garcia Fonseca / Banca: Gelson Luis Adabo / Banca: Paulo Francisco Cesar / Resumo: O titânio, em virtude de suas atrativas propriedades, foi introduzido na área de reabilitação oral podendo ser indicado para a confecção de restaurações metalocerâmicas dento- ou implanto-suportadas. No entanto, apresenta dificuldade de união com materiais resinosos, o que poderia comprometer a longevidade dessas restaurações, considerando a importância da qualidade de união na interface metal/cimento. Para contornar este problema, pode-se lançar mão de tratamentos de superfície do titânio, empregados isoladamente ou em associação. Este estudo avaliou a eficácia de diferentes tratamentos de superfície na resistência ao cisalhamento (RC) da união do cimento ionomérico modificado por resina RelyX Luting 2 e dos cimentos resinosos RelyX ARC e RelyX U100 ao titânio comercialmente puro (Ti cp). Duzentos e quarenta discos (9 x 3 mm) foram fundidos em Ti cp, incluídos em tubos de PVC e regularizados com lixas de carbeto de silício (150, 400 e 600) em politriz. Os espécimes foram divididos aleatoriamente em oito grupos (n=30), os quais receberam um dos seguintes tratamentos de superfície: (1) Al2O3 50 μm; (2) Al2O3 120 μm; (3) Al2O3 250 μm; (4) Al2O3 50 μm + silano; (5) Al2O3 120 μm + silano; (6) Al2O3 250 μm + silano; (7) Cojet Sand (30 μm) + silano; (8) Al2O3 120 μm + Rocatec (110 μm) + silano. Os cimentos (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 foram aplicados às superfícies tratadas do Ti cp (n=10). Os espécimes foram termociclados (5.000 ciclos, 5 e 55 °C, 30 segundos de imersão) e, então, submetidos ao ensaio de cisalhamento (0,5 mm/min). O modo de fratura foi avaliado em estereomicroscópio (x20). Os dados foram analisados por ANOVA 2 fatores e teste de Tukey (α=0,05). Os cimentos RelyX Luting 2 e RelyX U100 apresentaram comportamento semelhante com relação ao tratamento de superfície... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium was introduced in the field of oral rehabilitation because of its attractive properties, as it can be indicated for fabricating tooth- or implant-supported metal ceramic restorations. However, difficulties have been shown to exist as regards the bond between resin-based materials and titanium, which could compromise the longevity of these restorations, considering the importance of the bond quality at the metal/cement interface. To overcome this problem, titanium surface treatments can be applied alone or they can be combined with each other. This study evaluated the efficacy of different surface treatments on the shear bond strength (SBS) of RelyX Luting 2 resin-modified glass ionomer cement, RelyX ARC and RelyX U100 resin cements to commercially pure titanium (CP Ti). Two hundred and forty discs (9 x 3 mm) were cast from CP Ti, embedded in PVC tubes and smoothed with silicon carbide papers (150, 400 and 600) using a polisher. Specimens were randomly divided into 8 groups (n=30), which received one of the following surface treatments: (1) 50 μm Al2O3; (2) 120 μm Al2O3; (3) 250 μm Al2O3; (4) 50 μm Al2O3 + silane; (5) 120 μm Al2O3 + silane; (6) 250 μm Al2O3 + silane; (7) Cojet Sand (30 μm) + silane; (8) 120 μm Al2O3 + Rocatec (110 μm) + silane. The luting cements (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 were applied to the treated CP Ti surfaces (n=10). Specimens were thermal cycled (5,000 cycles, 5 and 55 °C, 30-second dwell time), and afterwards submitted to SBS testing (0.5 mm/min). Failure mode was evaluated under a stereomicroscope (x20). Data were analyzed using 2-way ANOVA and Tukey's test (α=0.05). The RelyX Luting 2 and RelyX U100 luting cements exhibited similar behavior regards to the surface treatment. For both, only the group abraded with 50 μm Al2O3 particles promoted lower SBS than the other groups (P>.05)... (Complete abstract click electronic access below) / Mestre
7

Resistência ao microcisalhamento de diferentes sistemas adesivos no esmalte dental humano /

Nagayassu, Marcos Paulo. January 2007 (has links)
Orientador: Marcelo Fava de Moraes / Banca: Victor Elias Arana Chavez / Banca: Matsuyoshi Mori / Banca: Silvio Issáo Myaki / Banca: Lafayette Nogueira Junior / Resumo: O objetivo deste estudo foi avaliar in vitro a resistência ao microcisalhamento de 5 sistemas adesivos ao esmalte, sendo 1 adesivo monocomponente (M), 2 primers autocondicionantes (P) e 2 adesivos autocondicionantes (A). Foram utilizadas 60 faces (vestibular ou lingual) de pré-molares, aplainadas com lixas d'água (400 e 600) e divididas aleatoriamente em 5 grupos (n=12), de acordo com o adesivo utilizado: SB2- Single Bond2 (M); CSE- Clearfil SE Bond (P); ADS- AdheSE (P); PLP- Adper Prompt L-Pop (A); XE3- Xeno III (A). Tubos de Tygon delimitaram a área de adesão em 0,8mm de diâmetro, para se obter os cilindros de resina composta (Z250). Após armazenamento em água destilada a 37ºC por 24h e termociclagem, foi realizado o teste de microcisalhamento (velocidade de 0,5mm/min).). Os dados foram submetidos aos testes de ANOVA e Tukey ('alfa'=5%). Os valores de média (MPa'mais ou menos'DP) e os resultados do teste de Tukey foram: SB2: 36,36('mais ou menos'3,34)a; ADS: 33,03('mais ou menos'7,83)a; XE3: 32,76('mais ou menos'5,61)a; CSE: 30,61('mais ou menos'6,68)a; PLP: 22,17('mais ou menos'6,05)b. Grupos com a mesma letra não apresentaram diferenças significantes. Pode-se concluir que não houve diferença estatística entre SB2, ADS, XE3 e CSE, apesar dos diferentes padrões de condicionamento destes adesivos. Apenas o PLP apresentou valores médios de adesão inferiores aos demais. / Abstract:The aim of this in vitro study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two selfetching primers (P) and two all-in-one self-etching adhesives (S). Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to adhesive system: SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (internal diameter of 0,8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37oC for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test ('alfa'=5%). Mean bond strength values (MPa'mais ou menos'SD) and the results of Tukey test were: SB2: 36.36('mais ou menos'3.34)a; ADS: 33.03('mais ou menos'7.83)a; XE3: 32.76('mais ou menos'5.61)a; CSE: 30.61('mais ou menos'6.68)a; PLP: 22.17('mais ou menos'6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others. / Doutor
8

Avaliação da eficácia de primers para metal na resistência ao cisalhamento da união entre cimentos resinosos e metais não nobres. Efeito do armazenamento em água /

Fonseca, Renata Garcia. January 2008 (has links)
Resumo: O sucesso das restaurações metálicas indiretas depende, dentre outros fatores, de uma união eficaz entre a estrutura metálica e o cimento dentário empregados. Sabe-se que os primers para metal atuam com comprovada eficácia na resistência adesiva dos cimentos resinosos às ligas nobres. Entretanto, pouco foi estudado sobre o efeito de tais materiais em ligas não nobres. O propósito deste estudo foi avaliar a eficácia de primers para metal na resistência ao cisalhamento da união entre cimentos resinosos e metais não nobres. Discos (9 mm de diâmetro e 3 mm de altura) foram fundidos em liga de NiCr (n=80) e em titânio comercialmente puro (Ti c.p.) (n=80) e foram incluídos em anel de PVC com resina acrílica quimicamente ativada. As superfícies dos discos foram regularizadas com lixas de carbeto de silício de granulação 320, 400 e 600 e jateadas com partículas de óxido de alumínio de 50 µm. Espécimes de cada metal foram divididos em quatro grupos (n=20). Uma matriz metálica bi-partida (5 mm de diâmetro interno e 2 mm de altura) foi posicionada na superfície do espécime. As áreas adesivas receberam um dos seguintes tratamentos: 1) Panavia F; 2) Alloy Primer e Panavia F; 3) Bistite DC e 4) Metaltite e Bistite DC. Para evitar a exposição dos cimentos à luz, estes foram espatulados e inseridos na matriz dentro de uma câmara de revelação radiográfica. Quarenta minutos após a confecção, os espécimes foram armazenados em água destilada a 37ºC por 24 horas e então termociclados (1.000 ciclos, 5ºC e 55ºC, 30 segundos cada banho). Após a termociclagem, os espécimes foram armazenados novamente nas mesmas condições descritas anteriormente por um período de 24 horas (n=10) ou de 6 meses (n=10) antes do ensaio de cisalhamento em uma máquina de ensaios mecânicos (Material Test System 810). / Abstract: A successful indirect metallic restoration depends, among other factors, on an effective bonding between metal framework and dental cements. There is scientific evidence that metal primers work effectively on adhesive bonding of resin cements to noble alloys. However, there are few studies about the effect of these primers on base metal alloys. The purpose of this study was to evaluate the efficacy of metal primers on shear bond strength of resin cements to base metals. Discs specimens (9 mm diameter and 3 mm thick) were cast from nickel-chromium alloy (n=80) and pure titanium (CP Ti) (n=80), and were embedded in a polyvinyl chloride ring, using polymethyl methacrylate acrylic resin. All specimen bonding surfaces were smoothed with 320-, 400- and 600-grit silicon carbide paper, and airborne-particle abraded with 50 µm aluminum oxide. Specimens for each metal was divided into 4 groups (n=20). A custom-made metal matrix (5.0 mm internal diameter and 2.0 mm thick) was placed on the surface of the specimen. The bonding sites received 1 of the following treatments: 1) Panavia F; 2) Alloy Primer plus Panavia F; 3) Bistite DC and 4) Metaltite plus Bistite DC. To avoid exposure of the resin cements to daylight, they were mixed and inserted into the matrix inside a radiographic developing chamber. Forty minutes after preparation, all specimens were stored in distilled water at 37ºC for 24 hours, and thermal cycled (1000 cycles, 5 to 55°C, dwell time of 30 seconds). After the thermal cycles, the specimens were stored in 37ºC distilled water for an additional 24 hours (n=10) or 6 months (n=10) before being subject to a shear load using a mechanical testing machine (Material Test System 810). Mode of failure was observed by means of stereomicroscopic, and classified as either adhesive, cohesive or a combination of both. Data were analyzed using parametric tests (α=.05).
9

Estudo da influência da ciclagem mecânica sobre a resistência de união ao cisalhamento entre uma cerâmica de recobrimento estético e duas cerâmicas infiltradas por vidro /

Landim, Karine Tenório. January 2006 (has links)
Orientador: Renato Sussumu Nishioka / Banca: Osvaldo Daniel Andreatta Filho / Banca: Lafayette Nogueira Junior / Resumo: Este estudo avaliou a influência da ciclagem mecânica na resistência de união ao cisalhamento entre cerâmicas infiltradas por vidro para infra-estrutura (In-Ceram Alumina - Vita Zahnfabrik e In-Ceram Zircônia - Vita Zahnfabrik) e uma cerâmica vítrea de recobrimento (VITA VM7 - Vita Zahnfabrik). Foram preparadas vinte e quatro amostras cilíndricas nas dimensões de 4mm de diâmetro por 5mm de altura para cada cerâmica de infra-estrutura. Posteriormente, a cerâmica de recobrimento estético foi aplicada, resultando em corpos-de-prova com 4mm de diâmetro e 9mm de altura, os quais foram divididos em 4 grupos: ICA; ICAM; ICZ e ICZM. Os grupos ICAM e ICZM receberam ciclagem mecânica, com força de 50N, freqüência de 1Hz, durante 20000 ciclos. O ensaio de cisalhamento foi realizado em máquina de ensaio universal (modelo DL - 1000, EMIC - Equipamentos e Sistemas LTDA., São José dos Pinhais - PR - Brasil) com velocidade de 0,5mm/min e as amostras carregadas até a fratura. As interfaces das amostras pós-fratura foram analisadas em estereomicroscópio (20x) e microscopia eletrônica de varredura. As médias e desvios padrão obtidos foram: ICA (30,04 l 11,74); ICAM (32,17 l 9,59); ICZ (44,33 l 11,47); ICZM (43,52 l 8,33). Os dados obtidos (MPa) foram analisados estatisticamente por meio de análise de variância (ANOVA) dois fatores e teste de Tukey (P<0,05). Os resultados mostraram diferença estatisticamente significante entre os grupos In-Ceram Alumina e In-Ceram Zircônia, porém a ciclagem mecânica não influenciou na resistência de união entre as cerâmicas de infra-estrutura e de recobrimento estético estudadas / Abstract: This study evaluated the influence of cyclic loading on shear bond strength between two glass-infiltrated ceramics for substructure (In-Ceram Alumina - Vita Zahnfabrik and In-Ceram Zirconia - Vita Zahnfabrik) and one glass veneer ceramic (VITA VM7 - Vita Zahnfabrik). Twenty four cylindrical samples with 4mm diameter per 5mm high was to prepare for each ceramics for substructure. Subsequently, the venner ceramic was applied to ceramic substructure, resulting in 4mm diameter per 9mm high specimens. They were divided in four groups ICA; ICAM; ICZ and ICZM. The groups ICAM and ICZM where cyclic loadind from 50N, 1Hz during 20000 cycles. Shear bond testing was performed in a universal testing machine (DL - 1000 model, EMIC - Equipamentos e Sistemas LTDA., São José dos Pinhais - PR - Brasil), with crosshead speed of 0,5mm/min and the specimens were loaded until failure. The interfaces of representative fractured specimens of each group were examined with microscopy (20x) and scanning electron microscopy. The mean values and standard deviations were: ICA (30,04 l 11,74); ICAM: (32,17 l 9,59); ICZ: (44,33 l 11,47); ICZM: (43,52 l 8,33). Data for shear bond strength (MPa) where statistically analysed by variance analysis (ANOVA) two factors and Tukey's test (P<0,05). The results showed statistically significant differences between the groups In-Ceram Alumina and In-Ceram Zirconia, however the cyclic loading effect was not influenced on bond strength between ceramics for substructure and veneer ceramic studied / Mestre
10

Estudo comparativo in vivo e in vitro da resistência ao cisalhamento de braquetes metálicos colador com resina polimerizada com luz halógena e LEd /

Penido, Sérgio Milton Martins de Oliveira. January 2006 (has links)
Orientador: Ary dos Santos-Pinto / Banca: Vânia Célia Vieira de Siqueira / Banca: Rodrigo de Castro Albuquerque / Banca: Lídia Parsekian Martins / Banca: Luiz Gonzaga Gandini Júnior / Resumo: Este trabalho teve como objetivo avaliar a resistência ao cisalhamento, in vivo e in vitro, de braquetes metálicos (Abzil Lancer) colados em dentes humanos com material adesivo polimerizado xom luz halógena e LED. Os braquetes foram cotados em 60 pré-molares formando seis grupos. Nos Grupos I e II os braquetes foram colados nos segundos pré-molares respectivamente no lado direito e esquerdo dos pacientes. A polimerização do material adesivo foi com a luz de LED epara o GI e luz halógena para o GII. Nos demais grupos os braquetes foram colados em primeiros pré-molaressuperiores e inferiores extraídos por motivos ortodônticos. A polimerização realizada nos grupos III e V foi com o aparelho de LED enquanto que nos grupos III e V foi com o aparelho de LED enquanto que nos grupos IV e VI com luz halógena. Nos Grupos I e II testes de cisalhamento foram realizados utilizando-se dinamômetro sigital portátil diretamente na boca dos pacientes. Os grupos IIII, IV, V e VI foram armazenados em água destilada e levados a estufa a 37ºC por 24 horas e posteriormente, submetidos a termociclagem, com 1000 ciclos a 5 e 55ºC. Posteriormente, nos grupos III e IV, utilizou-se máquina universal de ensaios mecânicos e nos grupos IV e VI os ensaios mecânicos foram realizados com dinamômetro digital. Os valores médios da resistência ao cisalhamento em Mpa foram de: GI = 3,65; GII = 4,39; GIII = 6,45; GIV = 7,11; GV = 4,67; GVI = 4,21. Após a descolagem foram realizadas fotografias Das áreas de colagem. As imagens obtidas foram ampliadas %x, analisadas e classificadas de acorso com o índice de Adesivo Remanescente (IAR). Os resultados dos testes mecânicos in vivo ou in vitro. Os testes realizados com equipamento portátil digital tiveram valores médios significativamente menores em relação áqueles realizados em máquina de ensaios mecânicos universal. Não houve relação definida entre carga de ruptura e tipo de falha. / Abstract: This work as a purpose to assess the shear bond strength, in vivo and in vitro , of metallic brackets (Abzil lancer) bondedto human teeth with light-curing bonding material with halogen and led lights. The brackets were bonded to 60 premolars, so forming 6 groups.In GI and II the brackets were bonded to second premolars, resectively, on the right and left sides of the patients. The polymerization of the bonding material was with LED light for GI and halogen light for GII. In the other groups the brackets were bonded to superior and inferior first premolars, extrated for orthodontic reasons. The polymerizatio was performed in GII and V with LED device, while in GIV and VI eith halogen light. In GI and II shear strength tests were made using a portable digital dynamoter directly in the patients' mouths. GII, IV, V and VI were stored in distilled water and taken to sterilizer at 37ºC for 24 hours, and afterwards, submitted to thermocycling with 1000 cycles at 5 and 55 º. Then, in GIII and IV, the Universal testing machine was used and in GIV and VI the mechanical tests were performed with a digital dynamometer. The average values of shear strength in Mpa were: GI=3,65; GII=4,39; GIII=6,45; GIV=7,11; GV=4,67 and GVI=4,21. Pictures of thebonding areas were taken after the tests. The images obtained amplified 5 times, analyzed and classified, according to Adhesive remaining index (IAR). The results suggested that the LED light or the halogen light did not interfere in the results of the mechanical tests in vivo or in vitro. The tests performed with a portable digital device obtained average values significantly lower than those performed with Universal testing machine. There was no definite relation between shear bond strengths and kind of failure. / Doutor

Page generated in 0.0648 seconds