• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito do tempo e da desinfecção por micro-ondas no desempenho clínico e na quantificação de micro-organismos de um reembasador rígido /

Ribeiro, Roberta Chuqui. January 2009 (has links)
Resumo: Este estudo avaliou o efeito da desinfecção por micro-ondas sobre o desempenho clínico e a quantificação de micro-organismos de um reembasador rígido em diferentes intervalos de tempo. Foram selecionados 40 pacientes de ambos os sexos com idade entre 30 e 75 anos, utilizando prótese total superior com necessidade de reembasamento. Essas próteses foram reembasadas com o material Tokuyama Rebase II. Logo após o reembasamento, foi avaliado o escoamento e a lisura do material, classificando-os em satisfatório ou insatisfatório. Em seguida, a amostra foi separada em dois grupos: grupo GC (controle) - os pacientes higienizaram sua prótese três vezes ao dia por meio de escovação com sabão de coco. Além disso, a prótese foi retirada durante a noite, ficando imersa em água e grupo GD (desinfecção por micro-ondas) - nesse grupo, além da escovação com escova dental macia e sabão de coco, foi realizada a desinfecção da prótese por micro-ondas uma vez por semana utilizando a potência de 650W e o tempo de 3 minutos. No período noturno, a prótese também foi imersa em água. O material reembasador foi avaliado por dois profissionais treinados trabalhando separadamente após 7 dias, 15 dias, 1 mês, 3 meses, 6 meses, 9 meses e 1 ano. Foram analisadas as seguintes características: estabilidade de cor, brilho, descoloração ou manchamento, irritação dos tecidos orais, separação ou fratura do material e rugosidade superficial. Além disso, foi realizada a quantificação de micro-organismos presentes na superfície interna da prótese em todos os períodos experimentais. Os dados obtidos foram analisados por análise de variância e pelos testes de Tukey e Friedman, ao nível de significância de 5%. O material apresentou lisura e escoamento satisfatórios em todas as análises após o reembasamento. As próteses reembasadas submetidas à desinfecção... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of disinfection method on the clinical performance and quantification of microbial of a hard chairside reline resin after 1-year service period. Forty adult patients aged between 30 and 75 years, who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline complete maxillary dentures. Immediately after the reline, assessment of the flow and smoothness was rated by the clinician as satisfactory and unsatisfactory. The edentulous subjects were randomly divided into 2 groups (n=20) and dentures were cleansed according to two methods: CG (control group)- brushing with coconut soap and soft toothbrush; DG (disinfection group)-brushing according to previous methods and microwave disinfection once a week for 3 min at 650W. Furthermore, all dentures were immersed in water at night. Evaluations were conducted by two examiners working separately. Color stability, gloss, staining or material discoloration, irritation to oral tissue, detachment or frature of material and surface roughness were assessed at 7 and 15 days, 1, 3, 6 and 9 months and 1 year post-placement. Quantitative microbial cultures were taken from the tissue side of each maxillary denture at all experimental periods. The data were analyzed by ANOVA and Friedman and Tukey tests. A 95% confindence level was used. Flow and smoothness of the material during relining were considered to be good or satisfactory in all the cases. Values color alterations of DG were significantly lower than those of CG (P<0.05). Color change observed after 15 days are greater than values obtained at 7 days recall (P<0.05). All color changes observed for the CG were considered noticeable (between 1.5 and 3.0 NBS). In disinfection group, color change was slight (between 0.5 and 1.5 NBS). There were statistically significant... (Complete abstract click electronic access below) / Orientador: Eunice Teresinha Giampaolo / Coorientador: Carlos Eduardo Vergani / Banca: Ana Cláudia Pavarina / Banca: Ana Lúcia Machado / Banca: Helena de Freitas Oliveira Paranhos / Banca: Marcelo Ferraz Mesquita / Doutor
2

Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese /

Azevedo, Andréa. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Eunice Teresinha Giampaolo / Banca: Cláudio Rodrigues Leles / Resumo: Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below) / Mestre
3

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável /

Gonçalves, Alessandro Ribeiro. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Carlos Eduardo Vergani / Banca: João Neudenir Arioli Filho / Banca: Arlindo Abreu de Castro Filho / Banca: Eduardo Miyashita / Resumo: Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below) / Doutor
4

Efeito de tratamentos da superfície de união e materiais reembasadores na resistência ao impacto de resina para base de prótese /

Perez, Luciano Elias da Cruz. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Ana Cláudia Pavarina / Banca: Luiz Antonio Pessan / Resumo: Este estudo avaliou o efeito de tratamentos da superfície de união e de materiais reembasadores na resistência ao impacto de uma resina para base de prótese. Corpos-de-prova foram confeccionados com a resina Lucitone 550 (60x6x2 mm) e reembasados (2 mm) com o mesmo material (L) ou com as resinas para reembasamento imediato Tokuso Rebase (TR) e Ufi Gel Hard (UH). Para o material L, as superfícies de união permaneceram sem tratamento (L/L/ST) ou foram tratadas com o monômero da resina L (metil metacrilato) for 180 segundos (L/L/M). Quando o reembasamento foi realizado com os reembasadores imediatos, os tratamentos de superfície consistiram de aplicação dos agentes adesivos fornecidos pelos fabricantes (L/TR/A - diclorometano e L/UH/A - diclorometano e 2-hidroxietil metacrilato) ou tratamento com o monômero da resina L seguido pelos adesivos (L/TR/MA e L/UH/MA). Corpos-de-prova do material L intacto (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessa resina. Um total de 140 corpos-de-prova foi confeccionado, sendo 20 para cada condição experimental. Para metade dos corpos-de-prova, os entalhes foram realizados na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto (E1). Para os corpos-de-prova restantes, o entalhe foi realizado na espessura, envolvendo tanto o material reembasador como a resina de base, com profundidade de 1,2 mm (E2), permanecendo 4,8 mm de material intacto. Todos os entalhes, em forma de V, foram realizados na área central do comprimento dos corpos-de-prova. O teste utilizado foi do tipo Charpy, com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) de cada entalhe foram analisados, separadamente, utilizando-se ANOVA e teste de ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of surface treatments and reline materials on the impact strength of a denture base acrylic resin. Specimens were made using Lucitone 550 resin (60x6x2 mm) and relined (2 mm) with the same material (L) or with the hard chair-side reline resins Tokuso Rebase (TR) and Ufi Gel Hard (UH). For material L, the bond surfaces remained untreated (L/L/ST) or were wetted with resin L monomer (methyl methacrylate) for 180 seconds (L/L/M). When the relining was made with the hard reline materials, the surface treatments consisted of coating with the bonding agents supplied by the manufacturers (L/TR/A - dichloromethane and L/UH/A - dichloromethane and 2-hydroxyethyl methacrylate) or wetting with the resin L monomer followed by bonding agents application (L/TR/MA and L/UH/MA). Material L intact specimens (60x6x4 mm) were also made to determine the impact strength of the bulk resin. A total of 140 specimens were made, 20 for each experimental condition. Half of the specimens were notched across the width to a depth of 0.8 mm, leaving an effective depth under notch of 3.2 mm (E1). For the remaining specimens, the notch was cut across the thickness to a depth of 1.2 mm (E2) leaving an effective depth under notch of 4.8 mm. All the V-notches were machined at the midpoint of the length of the specimens. Impact tests were carried out on a Charpy type pendulum impact tester (0.5 J pendulum; distance between supporting points - 50 mm). Results (kJ/ m2) from each notch depth were analyzed separately using one-way ANOVA and Tukey's HSD tests (a = .05). No significant differences were noted among the mean impact values of L (1.39 kJ/ m2), L/L/ST (1.28 kJ/ m2) and L/L/M (1.20 kJ/ m2) specimens with the E1 notch (P>.05). Similar results were observed (P>.05) for the specimens with the E2 notch (L - 1.00 kJ/ m2; L/L/ST - 0.93 kJ/ m2; ...(Complete abstract, click electronic access below) / Mestre
5

Influência de diferentes resinas acrílicas e técnicas de polimerização na resistência de união e dureza shore A de materiais reembasadores macios /

Batista, André Ulisses Dantas. January 2003 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Francisco de Assis Mollo Junior / Banca: Maximiliano Piero Neisser / Resumo: O objetivo deste estudo foi avaliar a resistência de união à tração e dureza Shore A de dois materiais reembasadores macios (Eversoft e Molloplast-B), processados juntamente com três resinas acrílicas de base de dentadura (SR Triplex, Lucitone 550 e Acron MC), polimerizadas com diferentes ciclos de polimerização. As amostras para o ensaio de tração eram divididas em dois segmentos de resina acrílica, cada um com 60 x 10 x 10 mm, e um segmento central de material reembasador macio, com 3 x 10 x 10 mm. Dez espécimes foram confeccionados para cada combinação resina acrílica/material reembasador, polimerizados por três ciclos diferentes de polimerização, como segue: SR Triplex - 2 horas a 100ºC; Lucitone 550 - 90 minutos a 73ºC, seguido de 2 horas a 100ºC, e Acron MC - energia por microondas por 10 minutos a 850W. As amostras foram testadas em uma máquina de ensaios universais MTS-810, a uma velocidade de 5 mm/min. Os valores médios de resistência de união foram calculados e expressos em megapascals (MPa), e o tipo de falha foi avaliado e anotado como coesiva, adesiva ou mista. As amostras para a avaliação da dureza Shore A consistiam de corpos-de-prova com dimensões de 36 x 7 x 6 mm preparados com os dois materiais macios de reembasamento. Dez amostras de cada material também foram polimerizadas pelos ciclos de polimerização já apresentados e a dureza foi determinada em um durômetro Shore A, de acordo com as normas D-2240 da ASTM. Os dados de ambos os testes foram analisados pela análise de variância e teste de Tukey permitindo concluir que: a) o maior valor de resistência de união foi apresentado pelo material Molloplast-B, quando processado com as resinas acrílicas Lucitone 550 (1,41 +0,15 MPa) e SR Triplex (1,40 + 0,10 MPa),... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the tensile bond strength and Shore A hardness of two soft denture liners (Eversoft and Molloplast-B), processed against three heat-cured denture base acrylic resins (SR Triplex, Lucitone 550 and Acron MC), and polymerized by different curing cycles (water bath and microwave energy). Tensile specimens consisted of two segments of acrylic resin, each 60 x 10 x 10 mm, and a central segment of soft liner, 3 x 10 x 10 mm. Ten specimens were prepared by each liner/resin combination, and were cured by three different curing cycles, as follows: SR Triplex - boiling water for 2 hours; Lucitone 550 - 73ºC for 90 minutes, plus 2 hours at 100ºC; and Acron MC - microwave activation at 850W for 10 minutes. Specimens were tested in an MTS-810 Universal Testing Machine, at a crosshead speed of 5 mm/min. Mean bond strength was calculated and expressed in megapascals (MPa), and the type of failure was assessed and recorded as being cohesive, adhesive, or mixed. Shore A specimens consisted of 36 x 7 x 6 mm samples prepared with the two soft liners. Ten samples of each liner were polymerized by the curing cycles early presented. Hardness was determined in a Shore A durometer, according the ASTM D-2240 specification. Data from both tests were analyzed by ANOVA and Tukey test, showing that: a) the highest bond strength was presented by Molloplast-B, when processed against Lucitone 550 (1.41 +0.15 MPa) and SR Triplex (1.40 + 0.10 MPa) acrylic resins, and the lowest values were observed for Eversoft, when processed against Acron MC resin (0.38 + 0.06 MPa), b) when polymerized by microwave energy, both Molloplast-B and Eversoft presented their lowest bond strength values, when compared with the groups cured in water bath (p< .05), and c)...(Complete abstract, click electronic access below) / Mestre
6

Efeito das técnicas de desinfecção sobre a dureza e rugosidade superficial dos materiais reembasadores /

Pavan, Sabrina. January 2003 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Sergio Sualdini Nogueira / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: O objetivo deste estudo foi avaliar o efeito de técnicas de desinfecção utilizando soluções de glutaraldeído 2%, hipoclorito de sódio 5%, clorexidina 5% e energia por microondas sobre a dureza e rugosidade de superfície dos materiais reembasadores macios Ufi Gel , Molloplast-B, Eversoft e Mucopren soft. Quarenta corpos-de-prova de cada material com dimensões de 36x7x6 mm foram processados em muflas plásticas para microondas e polimerizados de acordo com as recomendações dos fabricantes. As amostras foram divididas em grupos (n=10) e submetidas à desinfecção por 10 minutos nas soluções químicas e, em forno de microondas doméstico por período de 3 minutos à 500W. As leituras de dureza e rugosidade foram realizadas 24 horas após a confecção dos corpos de prova e após aplicação do 1° e 2° ciclo de desinfecção, respectivamente. As leituras de dureza foram realizadas sobre uma das faces do corpo de prova com auxílio de durômetro Shore A. Sobre a face oposta foram realizadas as leituras de rugosidade com rugosímetro Surf-Corder SE 1700. Os dados obtidos foram submetidos à análise de variância e teste de Tukey ao nível de significância de 1%. Conclui-se que a aplicação de dois ciclos de desinfecção não produziu alterações na dureza dos materiais utilizados. Porém, houve diminuição na rugosidade após o primeiro ciclo de desinfecção. A técnica de desinfecção com solução de glutaraldeído 2% promoveu os maiores valores de dureza nos materiais Molloplast-B, Mucopren soft e Ufi Gel. Já o material Eversoft não apresentou alteração nos valores de dureza e rugosidade de superfície em nenhuma das técnicas de desinfecção. / Abstract: The aim of this study was to assess the effect of disinfections with 2% glutaraldehyde, 5% sodium hypoclorite, 5% chlorhexidine solution and microwave oven on hardness and roughness of soft denture liners Ufi Gel, Molloplast-B, Eversoft and Mucopren soft. Forty samples (36x7x6 mm) of each material were processed in special microwave flasks according to manufacturers' recommendation. Ten specimens of each material were immersed in each disinfectant solution for ten minutes or placed in a microwave oven for 3 minutes at 500W. The surface roughness and hardness values were recorded after 24 hours (control), and also at each two cycles of disinfection. Hardness readings were made on the sample surface with Shore A durometer according to the ASTM D-2240 specifications. The surface roughness was verified on the other surface using a Surf-Coder SE 1700 perfilometer. Data were submitted at analysis of variance and Tukey's test to 1% of level. The application of two disinfection cycles did not change the hardness values significantly. However, after the first cycle of disinfection, means of surface roughness were lower than those observed for the control. The glutaraldehyde solution promoted the highest values of hardness on Molloplast-B, Mucopren soft and Ufi Gel materials. The Eversoft did not show changes in hardness and surface roughness independent of disinfection technique. / Mestre
7

Avaliação clínica do efeito de dois métodos de desinfecção sobre a rugosidade, estabilidade de cor e formação de biofilme de próteses reembasadas /

Moffa, Eduardo Buozi. January 2010 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Cláudia Pavarina / Banca: Janaina Habib Jorge / Resumo: Este estudo avaliou clinicamente o efeito de dois métodos para limpeza de próteses sobre a rugosidade, estabilidade de cor e a quantificação de micro-organismos de um reembasador rígido em diferentes intervalos de tempo. Foram selecionados 30 pacientes de ambos os gêneros com idade entre 40 e 80 anos, portadores de prótese total superior com necessidade de reembasamento. Essas próteses foram reembasadas com o material Tokuyama Rebase II Fast segundo as recomendações do fabricante. Em seguida, a amostra foi dividida em três grupos (n=10): GC (Grupo Controle) - os pacientes higienizaram suas próteses três vezes ao dia por meio de escovação com sabão de coco; GP (Grupo Perborato) - os pacientes realizaram escovação com sabão de coco e imersão diária da prótese em solução de perborato de sódio durante 5 minutos; GChx (Grupo Clorexidina) - nesse grupo, além da escovação com sabão de coco, foi realizada diariamente a imersão da prótese por 5 minutos em solução de digluconato de clorexidina 2%. Antes da colocação da prótese, os pacientes foram orientados a enxaguá-la adequadamente. A rugosidade superficial e estabilidade de cor do material reembasador foram avaliadas pelo profissional imediatamente após o reembasamento e após 7, 15, 30, 90, e 180 dias. A coleta de microoganismos foi realizada após 7, 15, 30, 90, e 180 dias. A rugosidade superficial foi mensurada através da utilização de um rugosímetro, que fornece valores em Ra-μm. A estabilidade de cor foi avaliada por meio de um espectrofotômetro portátil (BYK - Gardner). Os valores de ΔE obtidos foram comparados utilizando-se a classificação determinada pelo National Bureau of Standards (NBS). Análise de variância de medidas repetidas no tempo (p=0,05) foi empregada na avaliação dos métodos de desinfecção sobre a rugosidade superficial, estabilidade de cor e contagem... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of two disinfection methods for dentures on the clinical performance and quantification of microorganisms of a hard chairside reline resin in different time period. Thirty patients aged between 40 and 80 who required denture reline treatment, participated in this study. Tokuyama Rebase II was used to reline the complete dentures. After that, the edentulous subjects were ramdomly divided into three groups (n=10) and dentures were cleansed according to three methods: CG (control group) - brushing with coconut soap and soft toothbrush; PG (Perborate group) - brushing according to previous methods and disinfection with sodium perborate for 5 minutes once a day during the entire evaluation period (180 days) and ChxG (Chlorhexidine Group) - brushing according to CG and disinfection with chlorhexidine digluconate 2% for 5 minutes once a day during the entire evaluation period (180 days). Surface roughness and color stability were assessed immediately after the relining and after 7, 15, 30, 90 and 180 days of treatment. Quantitative microbial cultures were taken from the tissue side of each maxillary denture after 7, 15, 30, 90 and 180 days of dentures disinfection. The surface roughness was measured using a roughnes meter, which provides values in Ramicrometers. The color stability was evaluated by means of a portable espctrofotômetro (BYK - Gardner). The ΔE values were compared using the classification determined by the National Bureau of Standards (NBS). Analysis of variance for repeated measures (p = 0.05) were used in the evaluation of disinfection methods on the surface roughness, color stability and microbial counts (cfu / ml). The analysis of variance with repeated measures identified a significant effect only on the time factor (p <0.001) for the values of surface roughness, discoloration and microbial quantification... (Complete abstract click electronic access below) / Mestre
8

Caracterização de materiais experimentais e comerciais para reembasamento imediato por meio de análise de propriedades físico-químicas e mecânicas /

Reis, José Mauricio dos Santos Nunes. January 2009 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Renata Cunha Matheus Rodrigues Garcia / Banca: Karin Hermana Neppelenbroek / Banca: João Neudenir Ariolli Filho / Banca: Eunice Teresinha Giampaolo / Resumo: Este estudo avaliou o comportamento exotérmico de 5 resinas rígidas para reembasamento imediato, duas experimentais (E1 e E2) à base de agentes de ligação cruzada (etileno glicol dimetacrilato e 1,4-butanediol dimetacrilato) e três comerciais (Kooliner-K, New Truliner-NT, Tokuyama Rebase II-TR II), bem como o grau de conversão (GC), a sorção (Sor) e a solubilidade (Sol) em água, a contração linear de polimerização (CLP), as propriedades viscoelásticas e a resistência à flexão desses materiais e de uma resina para base de prótese (Lucitone 550-L). Foi avaliada, ainda, a resistência de união (RU) entre os reembasadores e a resina de base. O comportamento exotérmico foi avaliado (n=4) com termopar tipo K inserido no interior das resinas, em matriz circular (60 x 2,0 mm), e mantido até a polimerização. O GC (%) foi avaliado (n=5) por espectroscopia de infravermelho por transformadas de Fourier (32 leituras; resolução 4,0 cm-1). A Sor e a Sol (μg/mm3) foram mensuradas (n=5) seguindo as recomendações da ISO 1567. A CLP (%) foi avaliada (n=10), em projetor de perfil (Nikon 6C), em corpos-de-prova circulares (50 x 0,5 mm). Para avaliar as propriedades viscoelásticas, corpos-de-prova (40 x 10 x 3,3 mm) foram submetidos (n=2) à análise térmica dinâmico-mecânica (DMTA) em diferentes intervalos de temperatura (ciclos). O módulo de armazenamento (E') e o amortecimento mecânico (tan δ) a 37ºC foram registrados durante o primeiro e último ciclo da DMTA. A temperatura de transição vítrea (Tg) foi mensurada somente no último ciclo da DMTA. Os ensaios mecânicos de flexão (0,5 mm/min) foram realizados (n=10) em corpos-de-prova (64 x 10 x 3,3 mm) intactos ou reembasados e a resistência (MPa) calculada na tensão máxima (RFM) e no limite de proporcionalidade (RFLP). Para avaliar a RU (MPa) entre os materiais, 60 cilindros (20 x 20 mm) da resina L foram processados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the exothermic behavior, degree of conversion (DC), water sorption (WSor), water solubility (WSol), linear polymerization shrinkage (LPS), viscoelastic properties and flexural strength of 5 hard chairside reline resins, two experimental (E1 and E2) based on crosslinking agents (ethylene glycol dimethacrylate and 1,4-butanediol dimethacrylate) and three commercially available (Kooliner-K, New Truliner-NT and Tokuyama Rebase II-TR II), and one heat-polymerized denture base resin (Lucitone 550-L). The shear bond strength (SBS) between the denture base resin and the reline materials was also evaluated. The exothermic behavior of circular specimens (60 x 2.0 mm) during polymerization was assessed (n=4) using a type K thermocouple. The DC (%) was measured (n=5) by Fourier Transformed infrared-attenuated total reflectance (FTIR-ATR) spectroscopy (32 scans; resolution of 4.0 cm-1). WSor and Wsol (μg/mm3) were determined (n=5) according to the recommendation stated in ISO 1567. The LPS (%) was measured (n=10) in circular specimens (50 x 0.5 mm) using a perfilometer (Nikon 6C). The viscoelastic properties of the specimens (40 x 10 x 3.3 mm) were evaluated (n=2) by dynamical-mechanical thermal analysis (DMTA) under different temperature ranges (runs). Values of storage modulus (E') and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. The glass transition temperature (Tg) was only measured from the last run. Ultimate flexural strength (UFS - MPa) and flexural strength at the proportional limit (FSPL - MPa) were determined (n=10) by three-point test (0.5 mm/min) using intact and relined specimens (64 x 10 x 3.3 mm). To evaluate the SBS between the materials, 60 cylinders (20 x 20 mm) of the denture base resin L were processed, relined (3.5 x 5.0 mm) and submitted to shear testing (0.5 mm/min). Data were analyzed by ANOVA and Tukey... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0925 seconds