• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito da irradiação por microondas sobre as propriedades viscoelásticas de resinas para base de prótese e reembasamento /

Lombardo, Carlos Eduardo Leão. January 2009 (has links)
Resumo: Este estudo avaliou o efeito da irradiação por microondas e da armazenagem em água sobre as propriedades viscoelásticas de duas resinas para base de prótese (Lucitone 550- L e Vipi Wave- VW) e duas resinas para reembasamento imediato (Kooliner- K e Tokuyama Rebase Fast II- TR II). Oito corpos-de-prova (40 x 10 x 3,3 mm) de cada material foram avaliados por meio de análise térmica dinâmico-mecânica (DMTA) após: acabamento (controle 1), armazenagem em água por 7 dias (controle 2), um (MW1) e 7 ciclos de irradiação por microondas (MW7). Para cada corpo-de-prova, ciclos de DMTA foram realizados dentro de intervalos de temperatura diferentes. Os valores do módulo de armazenamento (E') e de amortecimento mecânico (tan δ) a 37ºC foram obtidos no primeiro e último ciclos de DMTA. A partir do último ciclo, os valores de E' na temperatura de transição vítrea (Tg) e o máximo de tan δ também foram obtidos. Os dados foram submetidos à análise de variância a dois critérios e ao teste de Student-Newman-Keuls (α=0,05). Além disso, mensurações de temperatura no interior de corpos-de-prova de cada material, durante a irradiação por microondas (650 W/ 3 min), foram realizadas por meio da utilização de sensor de fibra óptica. Seis corpos-de-prova de cada material foram avaliados. Durante a irradiação por microondas, todos os corpos-de-prova atingiram a temperatura de ebulição da água em aproximadamente 130 s. A partir do primeiro ciclo de DMTA, MW 1 e controle 2 aumentaram significantemente os valores de E' e reduziram os valores de tan δ de K a 37ºC (P<0,05). No último ciclo de DMTA, o tan δ de K e TR II foi significantemente reduzido após MW1 (P<0,05). MW7 reduziu os valores de tan δ de K (P<0,05). Os valores de E' de L e VW foram semelhantes entre si e superiores aqueles produzidos por K e TR II (P<0,05). Na Tg, K produziu o menor E' e seu máximo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of microwave irradiation and water storage on the viscoelastic properties of two denture base resins (Lucitone 550-L and Vipi Wave-VW) and two reline resins (Kooliner-K and Tokuyama Rebase Fast II-TR II). Eight specimens (40x10x3.3mm) of each material were evaluated by dynamic mechanical thermal analysis (DMTA) after: processing, water storage for 7 days (WS), one (MW1) and 7 cycles of microwave irradiation (MW7). For each specimen, DMTA runs were carried out within different temperature intervals. Values of storage modulus (E') and loss tangent (tan δ) at 37ºC were obtained from the first and last runs. From the last run, values of E' at the glass transition temperature (Tg) and maximum tan δ were also recorded. Data were analyzed by 2-way ANOVA followed by Student-Newman-Keuls test (α=0.05). In addition, measurements of the inside temperature of each specimen during microwave irradiation (650W/3min) were conducted using a fiber optic temperature sensor. Six specimens of each material were evaluated. During microwave irradiation, all specimens reached the boiling temperature of water at approximately 130 s. From the first DMTA run, MW1 and WS significantly increased the E' and decreased the tan δ of K at 37°C (P<0.05). From the last run, the tan δ of K and TR II was significantly decreased after MW1 (P<0.05). MW7 decreased the tan δ of K (P<0.05). The E' of L and VW was similar and higher than K and TR II (P<0.05). At Tg, K produced the lowest E' and its maximum tan δ was increased after MW1 (P<0.05). The Tg mean values were arranged as: L>VW>TR II>K (P<0.05). Microwave irradiation and WS did not detrimentally affect the viscoelastic properties of the denture base and reline resins evaluated. / Orientador: Carlos Eduardo Vergani / Coorientador: Sebastião Vicente Canevarolo Júnior / Banca: Rafael Leonardo Xediek Consani / Banca: Ana Cláudia Pavarina / Mestre
2

Análise morfológica e de resistência à flexão da interface ponta ativa/haste metálica em fresas carbide após o uso de esterilização /

Marcelo, Caroline Canhizares. January 2007 (has links)
Orientador: Regina Helena Barbosa Tavares da Silva / Banca: Lígia Antunes Pereira Pinelli / Banca: Paulo Martins Ferreira / Resumo: Na prática odontológica os rigores de controle de infecção exigem do cirurgião-dentista procedimentos de esterilização e desinfecção sobre seus instrumentos para prevenir a infecção cruzada, porém, esses procedimentos podem levar à oxidação e, portanto, determinar o aparecimento de corrosão nos instrumentos rotatórios cortantes. Considerando as questões que têm sido levantadas sobre o efeito dos vários métodos de esterilização sobre a eficiência de corte e resistência dos instrumentos dentais, este trabalho teve como objetivo avaliar possíveis alterações morfológicas e também alterações na resistência de união ocorridas entre a ponta ativa/ haste metálica em fresas carbide causadas pelo uso e procedimentos de esterilização. Para tanto foram utilizadas 130 fresas carbide que foram divididas em grupos de acordo com o tratamento aplicado: controle, autoclave, estufa, microondas e glutaraldeído. Depois de completado o teste experimental proposto, todos os grupos foram submetidos ao teste de resistência à flexão. Foi realizada também análise morfológica (qualitativa) das fresas por fotomicrografias capturadas por meio de uma lupa estereoscópica LEICA com o software. Os dados foram devidamente anotados e submetidos à análise estatística com testes de Kruskal-Wallis e Dunn. Os resultados, tanto da avaliação morfológica quanto da resistência à flexão, mostraram que somente o grupo do glutaraldeído se comportou de maneira diferente do grupo controle, havendo diferença estatística significante entre esses dois grupos. E, os demais grupos foram estatisticamente semelhante ao grupo controle. Pode-se concluir que nenhum método físico de esterilização estudado (autoclave, estufa e microondas) influenciou negativamente as características morfológicas e a resistência de união da interface ponta ativa/haste metálica... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Such as in all professions related to health, in dentistry there are necessary procedures which limit or obstruct disease propagation through clinical practice. Among such procedures is the sterilization of rotary instruments to prevent the risk of cross-infection. Each day in clinical practice, physical and chemical methods of sterilization can corrode appearance. The presence of corrosion on rotary cutting instruments makes them unusable. Concerning questions that have been raised on effect of some sterilization methods on the cutting efficiency and dental instruments resistance, this paper aimed to evaluate the influence of cutting time, sterilization methods and the amount of sterilization cycles in morphologic alterations and fracture resistance between the cutting head/ steel shank of carbide burs. An in vitro study was carried out in which one hundred-thirty tungsten-carbide burs were divided into five groups in accordance with sterilization method: control; autoclave; dry heat; microwave and glutaraldehyde. Glass plates were cut for 2.5 minutes by each bur attached to a high-speed handpiece with an intermittent load of 0.68N. After cutting time, burs were cleaned, dried, and submitted to a sterilization method corresponding to each group. Each cutting time or sterilization cycles, the visual accompaniment of the burs and photographed under a stereomicroscope. All groups were submitted to the flexure strength test at the end of a stipulated time in the mechanical rehearsals machine, MTS. Results obtained were submitted to the Kruskal-Wallis test and Dunn, which showed that only the group of glutaraldeído had difference significant statistics of the control group and the another groups (autoclave, dry heat and microwave) had been statistical similar to the control group, in both the morphologic evaluation and the fracture resistance. It may be... (Complete abstract, click electronic access below) / Mestre
3

Influência de diferentes resinas acrílicas e técnicas de polimerização na resistência de união e dureza shore A de materiais reembasadores macios /

Batista, André Ulisses Dantas. January 2003 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Francisco de Assis Mollo Junior / Banca: Maximiliano Piero Neisser / Resumo: O objetivo deste estudo foi avaliar a resistência de união à tração e dureza Shore A de dois materiais reembasadores macios (Eversoft e Molloplast-B), processados juntamente com três resinas acrílicas de base de dentadura (SR Triplex, Lucitone 550 e Acron MC), polimerizadas com diferentes ciclos de polimerização. As amostras para o ensaio de tração eram divididas em dois segmentos de resina acrílica, cada um com 60 x 10 x 10 mm, e um segmento central de material reembasador macio, com 3 x 10 x 10 mm. Dez espécimes foram confeccionados para cada combinação resina acrílica/material reembasador, polimerizados por três ciclos diferentes de polimerização, como segue: SR Triplex - 2 horas a 100ºC; Lucitone 550 - 90 minutos a 73ºC, seguido de 2 horas a 100ºC, e Acron MC - energia por microondas por 10 minutos a 850W. As amostras foram testadas em uma máquina de ensaios universais MTS-810, a uma velocidade de 5 mm/min. Os valores médios de resistência de união foram calculados e expressos em megapascals (MPa), e o tipo de falha foi avaliado e anotado como coesiva, adesiva ou mista. As amostras para a avaliação da dureza Shore A consistiam de corpos-de-prova com dimensões de 36 x 7 x 6 mm preparados com os dois materiais macios de reembasamento. Dez amostras de cada material também foram polimerizadas pelos ciclos de polimerização já apresentados e a dureza foi determinada em um durômetro Shore A, de acordo com as normas D-2240 da ASTM. Os dados de ambos os testes foram analisados pela análise de variância e teste de Tukey permitindo concluir que: a) o maior valor de resistência de união foi apresentado pelo material Molloplast-B, quando processado com as resinas acrílicas Lucitone 550 (1,41 +0,15 MPa) e SR Triplex (1,40 + 0,10 MPa),... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the tensile bond strength and Shore A hardness of two soft denture liners (Eversoft and Molloplast-B), processed against three heat-cured denture base acrylic resins (SR Triplex, Lucitone 550 and Acron MC), and polymerized by different curing cycles (water bath and microwave energy). Tensile specimens consisted of two segments of acrylic resin, each 60 x 10 x 10 mm, and a central segment of soft liner, 3 x 10 x 10 mm. Ten specimens were prepared by each liner/resin combination, and were cured by three different curing cycles, as follows: SR Triplex - boiling water for 2 hours; Lucitone 550 - 73ºC for 90 minutes, plus 2 hours at 100ºC; and Acron MC - microwave activation at 850W for 10 minutes. Specimens were tested in an MTS-810 Universal Testing Machine, at a crosshead speed of 5 mm/min. Mean bond strength was calculated and expressed in megapascals (MPa), and the type of failure was assessed and recorded as being cohesive, adhesive, or mixed. Shore A specimens consisted of 36 x 7 x 6 mm samples prepared with the two soft liners. Ten samples of each liner were polymerized by the curing cycles early presented. Hardness was determined in a Shore A durometer, according the ASTM D-2240 specification. Data from both tests were analyzed by ANOVA and Tukey test, showing that: a) the highest bond strength was presented by Molloplast-B, when processed against Lucitone 550 (1.41 +0.15 MPa) and SR Triplex (1.40 + 0.10 MPa) acrylic resins, and the lowest values were observed for Eversoft, when processed against Acron MC resin (0.38 + 0.06 MPa), b) when polymerized by microwave energy, both Molloplast-B and Eversoft presented their lowest bond strength values, when compared with the groups cured in water bath (p< .05), and c)...(Complete abstract, click electronic access below) / Mestre
4

Análise da porosidade superficial em materiais reembasadores rígidos. Efeito da desinfecção por irradiação de energia de microondas /

Novais, Polyanna Maria Rocha. January 2005 (has links)
Orientador: Eunice Teresinha Giampaolo / Banca: Ana Cláudia Pavarina / Banca: Ana Lucia Machado / Banca: Hércules Jorge Almilhatti / Banca: Ricardo Faria Ribeiro / Resumo: Este estudo avaliou o efeito da desinfecção por irradiação de energia de microondas na porosidade superficial de quatro reembasadores rígidos (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR, Ufi Gel Hard - UGH) e uma resina termopolimerizável para base de prótese (Lucitone 550 - L). Concluiu-se que: 1) As irradiações por energia de microondas aumentaram o número de poros para o material K (P<0,05), quando este foi submetido a 7 ciclos, em relação ao G1. Entretanto, a área total de poros não exibiu essa influência (P>0,05) em todos os grupos avaliados. 2) O material NT não sofreu efeito das irradiações para o número de poros em todos os grupos. Entretanto, a área de poros foi reduzida (P<0,05), quando foram utilizados 7 ciclos (G3), em comparação a 2 ciclos (G2). 3) As microondas reduziram o número de poros para o material TR (P<0,05), quando este foi submetido a 7 ciclos, em comparação ao G1 e G2. Sua área total de poros, no G3, exibiu redução significativa, em relação aos demais grupos avaliados. 4) A resina UGH, quando submetida a 7 ciclos de irradiação (G3), teve o número de poros reduzido (P<0,05), em relação ao G1 e G4. Entretanto, a área total de poros foi estatisticamente igual para todos os grupos. 5) O número e a área de poros do material L não foram influenciados (P>0,05) pelas irradiações. / Abstract: This study evaluated the effect of microwave irradiation on the surface porosity of four hard chairside reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard-UGH) and one heat-polymerizing denture base acrylic resin (Lucitone 550-L). It was concluded that 1) Microwave irradiation promoted a significant increased (P<.05) in the number of pores for material K after 7 cycles; however, the total area of pores was not affect by irradiation in all groups evaluated. 2) Material NT was not affected by irradiation for the number of pores; however, the total area of pores was decrease after 7 cycles, when compared to G2. 3) For material TR, microwave irradiation decreased (P<.05) the number of pores after 7 cycles, compared to G1 and G2. The total area of pores of G3 was significantly decreased after 7 cycles. 4) Material UGH showed a significant decrease (P<.05) for number of pores when submitted to 7 cycles, compared to G1 and G4; however, the total area of pores was statically equal in all groups evaluated 5) For material L, the number and total area of pores were not affected by irradiations. / Doutor
5

Efeito do reembasamento da ciclagem mecânica e da desinfecção por microondas sobre a força máxima de fratura, deformação, energia de ruptura e estabilidade dimensional de bases de prótese /

Seó, Rosangela Seiko. January 2006 (has links)
Orientador: Carlos Eduardo Vergani / Banca: Ana Lucia Machado / Banca: Marco Antonio Compagnoni / Banca: Marcelo Ferraz Mesquita / Banca: Rodrigues Nunes Rached / Resumo: O estudo avaliou o efeito do reembasamento, da ciclagem mecânica, da ciclagem térmica e da desinfecção por microondas sobre a força máxima de fratura, a deformação, a energia de ruptura e a estabilidade dimensional de bases de prótese. Os resultados evidenciaram que as variações intra-orais tais como os estresses térmico e mecânico aumentaram a degradação e diminuíram a vida útil das bases de prótese intactas e reembasadas com o material reembasador TRFII. A desinfecção por microondas produziu uma contração significativa das bases de prótese intactas e aquelas reembasadas com os materiais NTL e K. A desinfecção por microondas não afetou os valores de força máxima de fratura das bases de prótese intactas ou reembasadas com diferentes materiais reembasadores; porém, os valores de energia de ruptura e deformação das bases de prótese reembasadas com TR e NTL foram significativamente reduzidas após os ciclos de desinfecção por microondas e armazenamento em água por 7 dias. / Abstract: This study investigated the effect of relining, thermal stress, mechanical stress and microwave disinfection on the maximum fracture load, deflection at fracture, fracture energy and dimensional stability of intact denture bases and those relined with four autopolymerizing reline resins. Thermal and mechanical stresses adversely affect the strength of intact and/or relined denture bases; however, effects vary based upon the relining material used. Microwave disinfection produced increased shrinkage of intact specimens and those relined with New Truliner and Kooliner. The strength of the denture bases relined with New Truliner was not significantly affected by any of the experimental conditions, but comparing the control groups, New Truliner exhibited the lowest maximum fracture load values. The maximum fracture load of specimens was not affected by microwave disinfection. Microwave disinfection and water storage for 7 days decreased the deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner. The deflection at fracture and fracture energy values of specimens relined with Tokuso Rebase Fast and New Truliner were affected by microwave disinfection. / Doutor
6

Avaliação da disponibilidade de boro em um latossolo de Mato Grosso/MT /

Bíscaro, Thaís, 1978- January 2005 (has links)
Orientador: Ciro Antonio Rosolem / Banca: Dirceu Maximino Fernandes / Banca: José Carlos Casagrande / Resumo: Em algumas condições não se têm obtido correlações entre os teores de B do solo, extraído com água quente, o teor de boro na planta e a produtividade da soja no Estado do Mato Grosso, mais precisamente na região de Campo Novo do Parecis. Sabe-se que o boro é um nutriente fortemente adsorvido nas partículas minerais do solo. Objetivou-se com este trabalho submeter amostras de solo de uma determinada área de estudo, na qual foi cultivada soja por três anos consecutivos e posteriormente cultivado algodão, a diferentes métodos de extração de boro, a fim de se estabelecer correlações entre a dose de boro na planta, a dose de nutriente aplicada e o teor de boro no solo disponível às plantas e, ainda, com a produtividade da soja. Amostras de solo, cultivadas com soja, coletadas por ocasião da condução do experimento no campo, foram analisadas quanto à concentração de B extraída pelos métodos: água quente modificado com solução de BaCl2 1,25 g L-1 (recomendado e chamado de método da água quente pelo IAC); água quente modificado com solução de CaCl2 0,01 mol L-1,a quente e água quente tradicional (o qual é preconizado por muitos autores como o método oficial) para dessa forma, tentar quantificar a real disponibilidade de boro neste solo, caracterizado como um LATOSSOLO VERMELHO AMARELO (LVA), possibilitando a determinação de um nível crítico. Ainda, durante o período de condução do trabalho, foi feito um estudo de adsorção de B nas amostras, e um estudo do comportamento da lixiviação do nutriente em colunas de solo, procurando verificar o efeito das adubações na dinâmica do nutriente. Em relação aos métodos de extração de boro no solo, o CaCl2 foi o que apresentou correlação positiva e significativa com o boro presente no tecido vegetal nos três anos agrícolas. Os métodos do BaCl2 e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In some conditions, doesn't have obtained correlations among boron content in soil, boron extracted by hot water, boron content in plants and soybean productivity in a region (Campo Novo do Parecis) of the state of Mato Grosso/Brazil. This work was carried out to submit soil samples from determined area of study where was tillage soybean for three subsequent years and after tillage cotton, to differents extraction methods by boron with the aim to establish correlations among, amount of boron content in plants, amount of nutrient putted in soil, boron content in soil disponible to plants and the productivity. Soil samples obtained during the conduction of experiment on field were analyzed to predict the amount of boron in soil by the methods: hot water modified with BaCl2 solution (recommended and called by hot water from IAC - Instituto Agronômico de Campinas/SP-Brazil), hot water modified CaCl2 0,01 mol L-1 solution and hot water traditional (which is preconized by many authors like the official method) to this way try to quantify the real situation of boron disponibility in this soil, characterized like a Yellow Red Latossol, to take the determination of a critical level. During the conduction period of this work was made an adsorption study in the samples, and still a study of boron leaching behavior in soil columns, to verify fertilizer effect in nutrient dynamic. The extraction method with CaCl2 presented positive and significative correlation with boron present in soybean leaves on three subsequent farm work years. BaCl2 method and hot water traditional also presented positives and significatives correlations each one in two farm work years, this results were expected in function of similarity among three methods, it's an evidence that there is a method with capacity to predict boron disponibility in soils of Mato Grosso... (Complete abstract, click eletronic address below) / Mestre

Page generated in 0.0502 seconds