1

Air reversing CO2 heat pumps

Andreassen, Hanne Elisabeth Bø January 2010 (has links)
<p>CO2 is an environmentally friendly refrigerant that has a no global warming potential when used as refrigerant. The current refrigerants used for air conditioning in public transport are chemical components, and have a high global warming impact. The possibility of replacing the conventional refrigerants by CO2 is investigated for various parts of the transport sector. A possible CO2system for heating and cooling for public transport has been modeled and simulated. This system is a turntable prototype which is reversing the airflows to provide either cooling or heating. It has two gascoolers and two evaporators for separate treatment of ambient and recycled air. The plate is rotated 180˚ to switch from heating to cooling mode. CO2 has large potential for expansion work, due to the normally large throttling losses for high ambient temperatures. An ejector has therefore been implemented in the heat pump circuit. The turntable prototype is modeled by the simulation tool Modelica, and it is investigated how this ejector system adjusts to varying ambient conditions and power demand. Weather data from the climate database Meteonorm was used as a basis for calculation of heating and cooling demand for a train compartment in five different cities, covering a variety of climates. A case study was performed based on an occupancy rate profile and operative hours of the heat pump for the compartment. Simulations were performed of the air reversing heat pump based on the heating -and cooling demand calculations for the five cities. The COP values obtained are very positive, and they are in general higher for heating than cooling mode. The COP is depending on the load, and decreases with reduced occupancy rate. For cooling mode the COP ranged from 3.1 to 6. For heating mode it ranged from 8.2 to 2.8. With the occupancy rate chosen, the annual energy savings is about 80% for all the 5 cities of the study. The fan work of the heat pumps was also included for 4 different operating modes. This reduced the total COP by between 10 to 40%, depending on heating and cooling power requirement and ambient conditions. The fin and tube gas coolers that were used in the Modelica model were compared to a set of MPE gas coolers. The total mass of the heat exchangers was reduced by 50%. One would still have to weigh the reduced mass and increased LCCP performance against the increased investment cost of the MPE heat exchangers.</p>
2

Romoppvarming i lavenergi kontorbygninger / Heating in low-energy building

Gram, Fredrik January 2012 (has links)
Denne oppgaven omhandler et plenumbasert omrøringsventilasjon løsning. Dette plenumbaserte ventilasjonssystemet er utstyrt med en perforert aluminiumshimling med en lufttett akustisk duk og en innfelte diffusor i himlingplaten. Himlingsvolumet blir brukt som tilluftskanal og har eksponert termiske masser i betongdekket i taket. Denne løsningen har blitt testet og dokumentert av Sintef som svært effektiv i forhold til kjøling uten å gå på bekostning av inneklimaet. Det har også blitt vist gjennom simuleringsresultater fra Sintef at det er mulig å eliminere all mekanisk kjøling ved hjelp av nattventilasjon og avkjøling av betongen i taket i plenumet. Firmaet Energi&amp;miljø AS bruker en slik tilluftsløsning i deres system kalt «kjølehimling». De ønsket å undersøke muligheten for å bruke varmluftsoppvarming i denne typen ventilasjonsløsning. Som case er det tatt utgangspunkt i et reelt kontor i Statens Hus i Stavanger som bruker denne ventilasjonsløsningen. Kontoret ble implementert i programvaren EnergyPlus, et avansert amerikansk simuleringsverktøy, som skal være blant de mest fleksible i forhold til modelleringsvalg. Det ble utviklet en modell med konvensjonell oppvarming for å sammenligne med en modell som brukte varmluftsoppvarming i kombinasjon med en omluftstrategi for å minimere lufttemperaturøkningen. For å evaluere systemet ble ulike endringer gjort på modellen for å skille ut effektene av termisk lagring i dekket og aluminiumshimlingens varmeoverføringsegenskaper. Ved å erstatte aluminiumshimlingen med en standard 10 mm isolasjonshimling kunne effekten av bruken av aluminium vurderes. Isolasjon ble plassert i taket for å undersøke den termiske lagringen i betongdekket, fordi isolasjonen delvis vil eliminere denne effekten, på grunn av lav konduktivitet og lav diffusivitet. Løsningen med isolasjon i taket kan også grovt sammenlignes med et standardsystem med tilluftkanal montert direkte i himlingen Det ble gjort grundige simuleringer på tre utvalgte dager som skulle representere ulike typer klima og som dermed skulle utfordre løsningen på forskjellige måter. De tre ulike dagene ble valgt fra klimadataen - den kaldeste dagen i året med et relativt stort soltilskudd, en relativ kald dag uten soltilskudd og den varmeste dagen i året med et stort soltilskudd. Disse dagene ble analysert med hensyn til luft- og operativtemperatur, varmefluks absorbert av himlingen, tillufts- og overflatetemperaturer, luftmengder og effekter på oppvarming. Modellene ble simulert over ett år, hvor energibruken til oppvarming, kjøling, vifter, pumper og interne laster ble evaluert. De ulike modellene ble deretter sammenlignet med hensyn til termisk komfort, energi- og effektbehov. Resultatene viste at løsningen med aluminium og eksponert betong i taket komme best ut i forhold til energibruk og termisk komfort. Den totale årlige energibruken var da 82,69 kWh/m2 12% lavere enn løsningen med standard isolasjonsplater mellom kontor og plenum. Den operative temperaturen oversteg ikke 26oC og lufttemperaturen oversteg ikke 24,5oC den varmeste dagen. Løsningen med isolasjon mellom plenum og kontoret vil gi det dårligste inneklimaet og den høyeste energibruken. Den operative temperaturen vil med en slik løsning overstige 27oC og lufttemperaturen vil overstige 26,5oC. Den totale årlige energibruken var 94,32 kWh/m2. Varmluftsoppvarming viste seg å ikke fungere i denne typen plenumbasert system fordi den krevde en femdobling av effekten til oppvarming sammenlignet med konvensjonell oppvarming. Med tilluftstemperaturer på 35oC inn i plenum resulterte det i en tilluftstemperatur på 22,5oC inn i kontoret. Settpunktet på 21oC ble ikke nådd på den relativt kalde dagen uten soltilskudd. Varmen ble absorbert i den eksponerte betongen i dekket og bidro bare med en temperaturøkning i betongoverflaten på 1oC, noe som er vanskelig å utnytte. Hovedgrunnen til dette er at konveksjonskonstanten i taket blir høy grunnet høyt luftskifte av volumet i himlingen. Dette, i kombinasjon med store temperaturforskjeller mellom overflate- og lufttemperatur, vil gir en høy varmeoverføring i taket, noe som fører til en økning på over 15 % i energibruk per kvadratmeter sammenliknet med et system som bruker en konvensjonell varmekilde plassert i kontoret. Det ble også oppdaget svakheter i simuleringsverktøyet EnergyPlus. Et materiale som aluminium med veldig høy konduktivitet ble under simulering observert til å oppføre seg mindre dynamisk enn forventet. På grunn av dette ble utvalgte verdier fra EnergyPlus brukt i en matematisk varmebalanse for å predikere himlingens overflatetemperatur. Deretter ble den simulerte himlingstemperaturen sammenlignet med den predikerte temperaturen. Denne sammenligningen viste ulik oppførsel av overflatetemperaturen i himlingen for den predikerte og den simulerte temperaturen. Grunnen til dette er trolig at tidsskrittet ikke er tilstrekkelig lavt. Det laveste tidsskrittet i EnergyPlus er på 60 sekunder, noe som er altfor stort til å klare registrere aluminiumens hurtige temperaturendringer. Energibehovresultatet ble i laveste laget sammenlignet med simuleringer gjort av Energi&amp;miljø som simulerte en energibruk på 114kWh/m2. Det var spesielt oppvarmingsbehovet som var veldig lavt. Dette skyldes trolig at det ikke var implementert solavskjerming i det sydvendte kontoret, og at det er konstant tilstedeværelse av en person, lys og utstyr. Det ble derfor også gjort en simulering av et nordvendt kontor for å undersøke forskjellen i oppvarmingsbehov, det ble også vist med ved implementering en liten pause og en lunsjpause. Dersom det var mulig skulle det opprinnelig også innhentes måledata fra termiske masser. Disse dataene skulle brukes til verifisering av simuleringsresultatene. Dette viste seg dessverre å være vanskelig da Energi&amp;miljø ikke hadde startet målinger av betongtemperaturer.
3

Oppvarming og varmegjenvinning i dagligvarebutikker / Heating and heat recovery of supermarkets

Nerum, Lars Kristian January 2012 (has links)
Dagligvarebutikker i Norge er store brukere av energi. Som et ledd i å redusere energibehovet for sine nåværende og fremtidige butikker, har dagligvarekjeden REMA 1000 inngått et samarbeid med SINTEF Energi. Dette samarbeidet inngår i prosjektet Creativ, hvor det overordnede målet er energieffektivisering og reduksjon av klimagassutslipp. REMA 1000 Dragvoll er en av butikkene hvor energibruken undersøkes gjennom dette samarbeidet, og denne butikken ble benyttet som en case i prosjektoppgaven gjennomført forut denne masteroppgaven. Det var derfor naturlig å analysere REMA 1000 Dragvoll ytterligere. Målet med denne oppgaven var å evaluere og optimalisere varmegjenvinningen og oppvarmingen i butikken. Først ble det gjennomført en litteraturstudie. Denne inkluderte en gjennomgang av energisystemene i en vanlig dagligvarebutikk, med fokus på kuldeanlegg, varmegjenvinning fra kuldeanlegg, oppvarmingssystemer, luftbehandlingssystemer og belysningsanlegg. Videre ble energisystemene i REMA 1000 Dragvoll gjennomgått, sammen med bygningens klimaskjerm. Energimålinger for REMA 1000 Dragvoll, behandlet av SINTEF Energi, ble deretter analysert. Målingene var gjennomført i perioden 1. april 2010 til 31. mars 2011. De viste at det butikkens energibehov var på 437 kWh/m2år, noe som er 85 % av gjennomsnittet for butikkene i Norge. I måleperioden var ikke varmegjenvinningskretsen i drift, og det tilsa at potensialet for energibesparelse var stort. Siden energibehovet til det frittstående utstyret ikke ble målt direkte, men inkludert i posten Annet i målingene behandlet av SINTEF Energi, ble det gjennomført en egen måling for dette utstyret. Målingene av energibruken til utstyret viste at det sto for ca. 14 % av den totale energibruken i butikken. De viste også at utstyret uten dører/luker hadde et tilnærmet dobbelt så høyt energibehov som det utstyret med lukkemuligheter. For å kunne analysere medgått energi til oppvarming i butikken, ble det gjennomført målinger i ventilasjonsanlegget og varmegjenvinningskretsen. Loggingene viste en jevn temperatur i butikken på rundt 20 °C, men en meget varierende temperatur på tilluften i ventilasjonsanlegget. Videre undersøkelser avdekket at reguleringen av varmeavgiverne i ventilasjonsanlegget var meget ustabil. Ustabiliteten skyldes trolig at shuntventilen i varmegjenvinningskretsen er for stor i forhold til massestrømmen i kretsen, og dermed har en for liten autoritet. En annen årsak kan være at PID-innstillingene i ventilens regulator er feil. Den ustabile reguleringen av shuntventilen forplanter seg i hele ventilasjonsanlegget og påvirker også driften av kuldeanlegget. Videre ble en energimodell for beregning av oppvarmingsbehovet til dagligvarebutikker, laget av Stefano Poppi, revidert slik at den passet med REMA 1000 Dragvoll. Inndata i modellen og beregningsmetoder ble gjennomgått før selve beregningene ble utført. Beregningsresultatene viste at det er et potensiale for energibesparelse på ca. 104 000 kWh/år hvis varmegjenvinningskretsen utbedres. Mulige utbedringer av de tekniske anleggene er diskutert. For å redusere energibehovet til kuldeanlegget, foreslås utskiftning av kuldeutstyret i butikken til utstyr med dører/luker. Det kan redusere energibehovet med opptil 40 %. I ventilasjonsanlegget foreslås en endring av innstillingene for omluft i bygget. Ved å resirkulere ventilasjonsluften mer fornuftig, kan en spare 4146 kWh/år, ifølge beregninger gjort i energimodellen. Det er i tillegg foreslått alternativer for ombygging av varmegjenvinningskretsen. Forslagene omhandler installasjon av en frekvensregulert sirkulasjonspumpe og varmeakkumulasjonstanker. Det anbefales å gjennomføre en ombygging av varmegjenvinningskretsen, slik at reguleringen av de tekniske anleggene blir mer stabil. I tillegg bør tidsinnstillingene for omluft i ventilasjonsanlegget endres. Disse tiltakene vil medføre en merkbar reduksjon i butikkens energibehov. Etter at utbedringene er gjennomført, bør det utføres nye målinger for å bekrefte effekten av tiltakene. Målingene vil også gi muligheten til ytterligere forbedringer av oppvarmings- og ventilasjonsanlegget.
4

Air reversing CO2 heat pumps

Andreassen, Hanne Elisabeth Bø January 2010 (has links)
CO2 is an environmentally friendly refrigerant that has a no global warming potential when used as refrigerant. The current refrigerants used for air conditioning in public transport are chemical components, and have a high global warming impact. The possibility of replacing the conventional refrigerants by CO2 is investigated for various parts of the transport sector. A possible CO2system for heating and cooling for public transport has been modeled and simulated. This system is a turntable prototype which is reversing the airflows to provide either cooling or heating. It has two gascoolers and two evaporators for separate treatment of ambient and recycled air. The plate is rotated 180˚ to switch from heating to cooling mode. CO2 has large potential for expansion work, due to the normally large throttling losses for high ambient temperatures. An ejector has therefore been implemented in the heat pump circuit. The turntable prototype is modeled by the simulation tool Modelica, and it is investigated how this ejector system adjusts to varying ambient conditions and power demand. Weather data from the climate database Meteonorm was used as a basis for calculation of heating and cooling demand for a train compartment in five different cities, covering a variety of climates. A case study was performed based on an occupancy rate profile and operative hours of the heat pump for the compartment. Simulations were performed of the air reversing heat pump based on the heating -and cooling demand calculations for the five cities. The COP values obtained are very positive, and they are in general higher for heating than cooling mode. The COP is depending on the load, and decreases with reduced occupancy rate. For cooling mode the COP ranged from 3.1 to 6. For heating mode it ranged from 8.2 to 2.8. With the occupancy rate chosen, the annual energy savings is about 80% for all the 5 cities of the study. The fan work of the heat pumps was also included for 4 different operating modes. This reduced the total COP by between 10 to 40%, depending on heating and cooling power requirement and ambient conditions. The fin and tube gas coolers that were used in the Modelica model were compared to a set of MPE gas coolers. The total mass of the heat exchangers was reduced by 50%. One would still have to weigh the reduced mass and increased LCCP performance against the increased investment cost of the MPE heat exchangers.
5

Heat Generation by Heat Pump for LNG Plants

Moe, Bjørn Kristian January 2011 (has links)
Abstract The LNG production plant processing natural gas from the Snøhvit field outside Hammerfest in northern Norway utilizes heat and power produced locally with gas turbines. Building a new production train supplied with electricity from the power grid is being evaluated as a possible solution for reducing CO2 emissions from the plant. Buying electricity from the grid rather than producing it in a combined heat and power plant makes it necessary to find new ways to cover the heat loads at the production plant. A project thesis was written in the fall semester 2010 evaluating the possibility of generating the necessary heat with heat pumps. It was concluded that parts of the required heat could be delivered with reasonable efficiencies using heat pumps. Further, a heat pump delivering heat to the CO2-removal system was analyzed. Simulations showed that the required heat load, reaching approximately 62 MW at full production, could be delivered from a heat pump using butane as working fluid. The electrical power consumption for the compressors would be 23.3 MW, giving the heat pump a COP of 2.66. In this master thesis the heat pump suggested earlier is analyzed, focusing on identifying losses. Several possible changes that will enhance the heat pump’s efficiency are suggested. The use of other workings fluids and mixed refrigerants are analyzed as well, using the process simulation software Pro/II. The simulations indicates that the heat pump should be equipped with a flash tank at middle pressure, thereby reducing throttling losses and required mass flows through the evaporators. In addition, the suction gas should be overheated as much as possible. Using mixed refrigerants lowers the efficiency of the heat pump. Finally, two new systems are suggested: One with butane as workings fluid and one with pentane, both with flash tank at middle pressure and superheated suction gas. The pentane-system gives the highest system COP, but requires much bigger compressors than the butane-system. The table shows the most important results. Working fluid Electrical power consumption [MW] Volume flow suction gas [m3/h] COP Butane (C4H10) 18.6 55000 3.35 Pentane (C5H12) 17.5 150000 3.54 The power grid electricity is assumed to have been produced without any CO2 emissions. Covering the heat required by the CO2 removal system with a gas fired furnace would generate CO2 emissions of approximately 120,000 tons per year. Heat pumps are a good solution because they deliver relatively cheap heat without these CO2 emissions.
6

Advanced analysis of measured data for efficient operation of modern buildings

Leboeuf, Francois January 2011 (has links)
The aim of this study is to define several methods that enable to estimate the heat exchanged in the different components of an air handling unit (AHU), and propose control strategy optimizations. The AHU studied is a part of a low energy office building located in Norway. The focus is especially made on its rotary heat recovery system, its heating/cooling coil and its heating coil. The data of one month recorded by the building energy management system (BEMS) have been used. The heat exchanged estimation methods presented in this paper are based on heat balances, valve positions and heat exchangers number of transfer unit (NTU). Comparison of the results obtained with the different methods outlined a poor quality of the valves positions signals. This fact has also been confirmed using a statistical method, the principal component analysis (PCA). Because of this issue, the methods proposed have not been validated. Regarding control strategy optimization, the use of a heat exchanged estimation method is required. The estimation method based on NTU has been used as reference, since this method does not use the valves positions signals. The goals of control strategy optimization are to reduce the energy costs and the CO2 emission. The proposed improvements are based on a new distribution between components of input heat, regarding the specific energy cost and CO2 emission of components. The tested optimizations gave better results that the current control strategy, but since the method used as reference has not been validated, these conclusions have to be confirmed after a resolution of the valves positions signals problems.
7

Skolebygninger - inneklima og effektiv energibruk / School buildings - indoor environment and energy efficiency

Halstadtrø, Elin January 2011 (has links)
Det er for lite kunnskaper om virkningen av hybride og balansert mekaniske ventilasjonsanlegg i norske skoler. Det er flere skoler som har blitt rehabilitert eller nybygd med slike l&#248;sninger de senere &#229;rene. Hovedm&#229;let med oppgaven er &#229; se p&#229; energibruken og inneklimaet til skoler med slike l&#248;sninger, sammenligne skolene p&#229; grunnlag av dette og se etter sammenhenger mellom teknisk l&#248;sning og inneklima. For &#229; unders&#248;ke inneklima og energibruk p&#229; skoler med forskjellige ventilasjonsl&#248;sninger ble det gjort befaringer p&#229; noen skoler i Larvik og Oslo. Skolene det er snakk om var RA, Tjodalyng og Mellomhagen i Larvik, og Rommen, Nordstrand og Elvebakken i Oslo. Av disse skolene skiller RA og Mellomhagen seg ut med henholdsvis ventilasjon basert p&#229; kulvert og ventilasjon via vinduer. De resterende har balansert mekanisk ventilasjon. Alle skolene som er unders&#248;kt har behovsstyring.P&#229; befaringene ble det gjort enkle intervjuer med noen ansatte og innhentet informasjon om skolene med fokus p&#229; energibruk, ventilasjon og oppvarming. I to klasserom p&#229; hver skole ble det ogs&#229; satt opp m&#229;leutstyr for &#229; logge og m&#229;le valgte inneklimaparametre. Lokale lufthastigheter ble m&#229;lt i flere punkter i alle klasserom. Grunnet for f&#229; CO2-loggere ble det m&#229;lt lokale CO2-konsentrasjoner i m&#229;lepunktene for lufthastighet p&#229; Mellomhagen og Elvebakken. CO2 ble ellers logget for de resterende klasserommene i to hele d&#248;gn, og temperatur ble logget for alle klasserom i samme periode. Dette ble utf&#248;rt i uke 10 og 11, vinteren 2011.Av m&#229;leresultatene kom det fram at hybrid ventilasjon med vindusl&#248;sning skiller seg ut fra hybrid ventilasjon med kulvert og balansert mekanisk ventilasjon. Vindusl&#248;sningen tilfredsstiller ikke kategori 2 av inneluftkvalitet for CO2-konsentrasjon og har fare for trekk om vinteren. Av temperaturlogging i oppholdssonen tilfredsstiller alle skolene temperaturkravet om 22 &#177; 2 &#186;C. Lokale lufthastigheter bekrefter at fortrengningsventilasjon krever ekstra god avstand foran ventiler for tilf&#248;rsel av frisk luft i vegg og at vinduslufting f&#248;rer til h&#248;ye hastigheter n&#230;rme vindu. Utenom dette har ikke noen av skolene for h&#248;ye lufthastigheter i oppholdssonen som vil f&#248;re til ubehag. Hybrid ventilasjon med kulvert og balansert mekanisk ventilasjon gir &#248;nsket inneklima for kategori 2.Intervjuer av ansatte b&#229;de bekrefter og motsier m&#229;leresultatene p&#229; enkelte punkter. Vindusl&#248;sningen blir oppfattet som behagelig og frisk uten klager p&#229; trekk eller st&#248;y, mens ansatte p&#229; skolene med balansert mekanisk ventilasjon mente at det var b&#229;de for varmt og for kaldt til tider, men ingen trekk. De ansatte p&#229; skolen med kulvertl&#248;sning hadde mest negativt &#229; si om inneklimaet hvor st&#248;y mellom rommene, lukter utenfra og generelt ustabil temperatur p&#229; hele skolen ga stor misn&#248;ye. Det kan derfor tyde p&#229; at de m&#229;lte parametere ikke viser det totale inneklimaet til skolene og at det b&#248;r unders&#248;kes flere parametere over lengre tid med p&#229;f&#248;lgende sp&#248;rreunders&#248;kelser av ansatte og elever.N&#229;r det gjelder energibruk p&#229; skolene var det ikke mulig &#229; innhente dette for skolene i Larvik. Det hadde v&#230;rt veldig interessant &#229; sammenligne hybrid ventilasjon mot balansert mekanisk ventilasjon for &#229; se om hybrid ventilasjon gir lavere energibruk, men dette ble dessverre ikke vist i denne oppgaven. For skolene i Oslo var innhentet spesifikk energibruk mellom 174 &#150; 198 kWh/m2&amp;#8729;&#229;r basert p&#229; skolenes totale oppvarmingsareal. Simulering av et klasserom i SIMIEN for disse skolene viste at et klasserom ikke kan representeres ved innhentet spesifikk energibruk da et klasserom kan ha h&#248;yere eller lavere energibruk enn skolen totalt.
8

Virkning av solavskjerming på energisparepotensial og dagslys i bygninger / Impact of Shading Devices on Energy Saving and Daylight in Buildings

Flægstad, Helge Venås January 2012 (has links)
I denne oppgaven er det sett p&#229; hvordan energibehov og lys i bygninger p&#229;virkes av solavskjerming.Solavskjermingens oppgave er ikke bare &#229; skjerme for sjenerende lys. &#216;kt fokus p&#229; passivhus f&#248;rer til at solavskjerming i st&#248;rre grad enn tidligere ogs&#229; m&#229; skjerme for varme. Det vil v&#230;re &#248;nskelig &#229; stenge ute varme samtidig som en slipper inn lys.Ved hjelp av simuleringer er det sett p&#229; hvilke utslag endring av ulike egenskaper i glasset gir p&#229; energibehov og belysningsstyrke i bygninger. Det er ogs&#229; sett p&#229; ulike glassbelegg, bygningsutspring og himmelretning. Av aktive solavskjerminger er det sett p&#229; persienner, da b&#229;de utvendig, mellomliggende og innvendig persienne og styring av disse. Simuleringene er gjennomf&#248;rt med tanke p&#229; skolebygg, men er overf&#248;rbare til andre bygningskategorier.De viktigste resultatene av simuleringene er: &#149;Glassets egenskaper: o g-verdi virker inn p&#229; &amp;#61607; energibehovet til oppvarming og kj&#248;ling &amp;#61607; effektbehovet til kj&#248;ling o u-verdi virker inn p&#229; &amp;#61607; energibehovet til oppvarming o t_v-verdien virker inn p&#229; &amp;#61607; belysningsstyrke &amp;#61607; energibehov til belysning &#149;Bygningsutspring virker inn p&#229; o belysningsstyrke o energi og effektbehov til kj&#248;ling &#149; Himmelretning virker inn p&#229; o energibehov til b&#229;de oppvarming, kj&#248;ling og belysning o belysningsstyrken &#149; Persienne: o Utvendig persienne gir &amp;#61607; h&#248;yere energibehov til oppvarming enn innvendig persienne &amp;#61607; lavere energi og effektbehov til kj&#248;ling enn innvendig persienneKonklusjon: &#149; Rom med kj&#248;lebehov b&#248;r o ha lav g-verdi o ha utvendig persienne o legges mot nord &#149;Rom uten kj&#248;lebehov b&#248;r o ha lav u-verdi o ha h&#248;y g-verdi o ha innvendig persienne o legges mot s&#248;r &#149; Rom med &#248;nske om h&#248;y belysningsstyrke b&#248;r o ha h&#248;y t_v-verdi o legges mot s&#248;r
9

Design av strømforsyningsanlegg til et elektrisk oppvarmingssystem for undervanns rørledninger / Design of Powersupply for DEH

Haugland, Rune January 2012 (has links)
For &#229; forhindre pluggdannelser (hydrater/voks) i transportr&#248;r subsea for olje/gass, som kan medf&#248;re produksjonsstans har SINTEF/NTNU Elkraftteknikk utviklet et system for elektrisk oppvarming av undervanns r&#248;rledninger. Dette systemet forkortes DEH.Oppvarming av r&#248;ret skjer ved &#229; kj&#248;re en stor str&#248;m gjennom r&#248;ret, hvor varme utvikles p&#229; grunn av r&#248;rets resistans. Av sikkerhetsmessige &#229;rsaker er r&#248;ret jordet i begge endene. Dette f&#248;rer til str&#248;mdeling mellom r&#248;ret og sj&#248;vann, hvilket reduserer effektiviteten til systemet betraktelig. Ineffektiviteten sammen med r&#248;roppvarmingens lave effektfaktor gj&#248;r at det vil g&#229; en stor str&#248;m i stigerkabelen ned til havbunnen. For &#229; begrense str&#248;mmen benyttes det fasekompensering med kondensatorer og et symmetreringsanlegg etter Steinmetz&#146; krets.For &#229; kunne analysere forsyningssystemet topside, er det valgt &#229; utarbeide en forenklet krets. Kretsen er verifisert av et laboratoriefors&#248;k og datasimuleringer i Matlab og Pscad. Resultatene viser at det aktive tapet i flere av komponentene i kretsen kan neglisjeres, noe som f&#248;rer til at formlene for Steinmetz&#146; symmetreringskrets gir god n&#248;yaktighet. Disse formlene sier at verdiene for komponentene i symmetreringkretsen er proposjonal med resistansen den ser. Det er utf&#248;rt analyser av virkningen av lastens effektfaktor som viser at den er bestemmende for den maksimale og minimale resulterende resistansen av lasten og fasekompenseringen, hvilket er den resistansen symmetreringskretsen ser. Analysene viser ogs&#229; at effektfaktoren er dimensjonerende for andre komponenter.
10

Simulation of indoor climate in ZEB in relation to heating and cooling system

Midtbust, Hans-Martin January 2014 (has links)
The purpose of this thesis was to study how the heating-, cooling- and ventilation systems affected the temperature distribution between the different zones in a building. Powerhouse Kj&#248;rbo is equipped with central radiator heating without radiators in the office cells. Temperature distribution in the office cells is therefore dependent on air flows through open doors and supply air from the ventilation.Evaluations of temperatures and thermal indoor climate for the office cells would have to be conducted, in order to examine if the temperature distribution was sufficient. A simulation model was therefore created.A Simulation model in IDA ICE was built as similar as possible compared to the actual building. Evaluations of the thermal indoor climate were done by analyzing the simulation results from IDA ICE. The simulations were performed with the aim of examining how different actions affect the temperature and thermal indoor climate in the office cells.The winter simulations showed that the office cells achieved low temperatures and a bad thermal indoor climate by only keeping the doors open outside the residence time. This meant that the temperature distribution through the doors was insufficient. By performing actions like increasing the set point for heating and supplying hot ventilation air, good indoor temperatures and a good thermal indoor climate were achieved.The summer simulations showed that the operative temperature exceeded 26 &#176;C, when no actions to prevent high indoor temperatures were performed. Further, the simulation results showed that external window shading and increased supply of ventilation air was effective for preventing high indoor temperatures. Good results for temperatures and thermal indoor climate were achieved, when these actions were included in the simulation model.The results from the simulations showed that a good thermal indoor climate can be achieved in the office cells, both summer and winter, if the correct actions are implemented.