• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 199
  • 199
  • 69
  • 58
  • 56
  • 56
  • 52
  • 48
  • 37
  • 35
  • 35
  • 33
  • 31
  • 26
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo da floculação, quebra e recrescimento de flocos com emprego de técnica de monitoramento contínuo em ensaios de bancada para as condições de tratamento de água por filtração direta

Adam Douglas Sebastião Pinto 05 August 2015 (has links)
Neste trabalho empregou-se um Equipamento de Monitoramento Contínuo da Floculação (EMCF), para melhor compreensão da formação, quebra e recrescimento de flocos, bem como o impacto na qualidade da água tratada por filtração direta descendente com pré-floculação em escala de bancada. Os flocos foram submetidos a gradientes de quebra variados, de 1400 s-1 a 101 s-1, condições passíveis de serem encontradas em filtros rápidos por gravidade, operados à taxa constante, e com durações da quebra de 5, 60 e 300 s. A água de estudo utilizada nos ensaios foi preparada em laboratório, com a adição de caulinita à água de um poço artesiano e apresentou valor de turbidez de 25 uT e pH de 6,50. O coagulante utilizado foi o sulfato de alumínio líquido isento de ferro (12,5 mg/L do produto comercial com teor de Al2O3 de 8,42%) em conjunto, ou não, com um polímero aniônico (0,05 mg/L). Foi possível observar que, os flocos, uma vez quebrados sobre distintos tempos e gradientes de velocidade, apresentaram diferentes potencialidades de recrescimento, sendo que, de maneira geral, quanto menores os valores dos gradientes de velocidade e durações da quebra, maior foi a capacidade dos flocos alcançarem tamanho semelhante ao observado antes do evento de quebra. Além disso, para a filtração direta com pré-floculação, observou-se que, para os maiores gradientes de velocidade e durações da quebra empregados no estudo, foram verificados os maiores valores de turbidez remanescente da água filtrada. Por outro lado, a aplicação conjunta do coagulante e polímero, para as mesmas condições de estudo, permitiu a obtenção dos menores valores de turbidez remanescente de água filtrada.
12

Diagnóstico e optimização do tratamento de águas residuais em leitos de macrófitas

Oliveira, João Miguel da Silva Campos January 2007 (has links)
Tese de mestrado. Engenharia do Ambiente. 2007. Faculdade de Engenharia. Universidade do Porto
13

Estudo da eficiência das ondas de ultra-som em relação ao hipoclorito de sódio e à filtração adsorção na eliminação de microrganismos em estação de tratamento de água /

Bello, Antonio Roberto Crystal. January 2003 (has links)
Resumo: Este estudo realizado em mini Estação de Tratamento de Água (ETA-CB) relata a comparação entre diferentes processos como ondas ultra-sônicas, cloração e filtração-adsorção na eliminação de microrganismos e adequação de outros parâmetros exigidos para água de abastecimento público. Para avaliar a influência de cada processo de desinfecção e também dos processos de coagulação - floculação, decantação e filtração foi projetada e construída uma ETA em escala piloto, constituída de caixa de entrada de água bruta e produtos químicos, uma câmara de coagulação - floculação com chicanas e meio granular, um decantador e um filtro rápido de fluxo descendente com meio filtrante de carvão ativado, areia e pedregulho. Na água além de coliformes totais, coliformes fecais E. coli e bactérias heterotróficas, foram avaliados o pH, temperatura, cor aparente, turbidez, sólidos suspensos, condutividade elétrica, sólidos totais dissolvidos, salinidade, ferro e cloro livre residual. Foram realizados ensaios de coagulação - floculação, decantação e filtração, com e sem pré-cloração ou aplicação de ondas ultra-sônicas. Também foram elaborados ensaios individuais de filtração, cloração e aplicação de ultrasom após os processos de coagulação - floculação e decantação. Por último foi avaliado individualmente a eficiência dos processos de filtração, cloração e ultra-som aplicados na água bruta em fluxo contínuo na ETA-CB, sem coagular e flocular. Foi constatado a importância do processo de coagulação - floculação e decantação na eliminação de bactérias. Ondas ultra-sônicas, cloração e filtração - adsorção mostraram-se eficientes na inativação ou eliminação de bactérias... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study tells the comparison among different processes as ultra-sonic waves, chlorination and filtration-adsorption in the elimination of bacterias in Station of Treatment of Water (ETA-CB). To evaluate the influence of each desinfection process and also of the coagulation-flocculation processes, sedimentaton and filtration was projected and built an ETA in pilot scale, constituted of box of entrance of rude water and chemical products, a coagulation - flocculation box with chicanes and middle to granulate, a decantor and a filter of descending flow with half filtrante of activated coal, sands and gravel. Besides total coliforms, fecal coliforms E.coli and heterotrophics bacterias, were appraised of the water the pH, temperature, apparent color, turbidity, suspended solids, eletric conductivity, dissolved total solids, salinity, iron and residual free chlorine. Coagulation rehearsals were accomplished flocculation, sedimentation and filtration, with and without chlorination or application of ultra-sonic waves. They were also made individual rehearsals of filtration, chlorination and ultrasound waves application after the coagulation - flocculation processes sedimentation. Last i was evaluated the efficiency of the filtration processes, chlorination and ultrasound waves individually applied in the raw water in continuous flow in ETA, without coagulating and flocculating. The importance of the coagulation process was verified - flocculation and sedimentation in the elimination of bacterias. Ultrasound waves, chlorination and filtration - adsorption showed efficient in the destruction or elimination of bacterias. The desinfection process with ultrasound waves together with the coagulation - flocculation, sedimentation and filtration, it can be seen as an alternative treatment of the traditional process of treatment of water in which is used of the desinfection with chlorine... (Complete abstract, click eletronic access below) / Orientador: Dejanira de Franceschi de Angelis / Coorientador: Roberto Naves Domingos / Banca: Aurora Mariana Garcia de França Souza / Banca: José Carlos Marconato / Mestre
14

Estudo de metodologias para avaliação de hidrômetros domiciliares em sistemas de água / A metodology studies for evaluation of domestic water meter under-registration in water systems

Silva, Nilce Regina da 28 November 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Departamento de Engenharia Civil e Ambiental, 2008. / Submitted by wesley oliveira leite (leite.wesley@yahoo.com.br) on 2009-09-18T16:47:05Z No. of bitstreams: 1 2008_NilceReginadaSilva.pdf: 4365695 bytes, checksum: b78df5bc5771f21f145cb8024f535504 (MD5) / Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2010-12-20T10:47:27Z (GMT) No. of bitstreams: 1 2008_NilceReginadaSilva.pdf: 4365695 bytes, checksum: b78df5bc5771f21f145cb8024f535504 (MD5) / Made available in DSpace on 2010-12-20T10:47:27Z (GMT). No. of bitstreams: 1 2008_NilceReginadaSilva.pdf: 4365695 bytes, checksum: b78df5bc5771f21f145cb8024f535504 (MD5) Previous issue date: 2008-10 / A avaliação dos fatores que provocam erros de medição de vazão tem fundamental importância para o controle de perdas nos sistemas de abastecimento público de água. A imprecisão na medição feita pelos hidrômetros residenciais, notadamente a submedição, representa uma parcela significativa das perdas aparentes. A utilização de reservatórios domésticos é um dos principais responsáveis pela submedição, devido ao amortecimento das vazões que provocam no abastecimento dos domicílios, fazendo com que os hidrômetros funcionem com vazões muito baixas, menores do que as que ocorrem em um sistema abastecido diretamente pela rede. Esse amortecimento é agravado pelo controle do nível desses reservatórios, que, geralmente, é feito por válvulas do tipo bóia, com vazão proporcional ao nível do reservatório, cujo impacto na submedição tem sido pouco estudado. Na literatura são encontradas poucas referências sobre essas válvulas. Neste trabalho procurou-se estudar a submedição provocada pelas válvulas com bóia em reservatórios domiciliares. Para isso simulou-se o abastecimento de residências a partir das curvas de vazão das válvulas de bóia e do consumo de água pelas residências. Para levantamento das curvas de vazão das válvulas construiu-se um aparato experimental que permitiu realizar o levantamento das vazões em função do nível do reservatório. O perfil de consumo das residências foi levantado a partir do registro das vazões consumidas em residências sem reservatório, utilizando-se data loggers. As curvas de erro de medição dos hidrômetros utilizados nas residências estudadas foram levantadas no laboratório da CAESB. Com os dados obtidos nas simulações, pôde-se estimar a submedição provocada pelas baixas vazões que passam pelas bóias, bem como analisar o efeito de diversas combinações entre os tipos de bóia ensaiados, os perfis de consumo e as curvas de erros dos hidrômetros. Os resultados alcançados evidenciaram que a submedição, provocada pelas válvulas do tipo bóia, pode ser agravada pela combinação entre o perfil de consumo do domicílio, o modelo de reservatório e a exatidão do hidrômetro utilizado. O uso de diferentes marcas e diâmetros de bóias apresentou pequena influência na submedição. _________________________________________________________________________________ ABSTRACT / The evaluation of the factors that cause the measurements errors has fundamental importance for the loss control in public water supply systems. The imprecision in the measurement done by the domestic water meters, specially the under-registration, represents a significant portion of the apparent losses and it will be the most relevant aspect in this work which intend to contribute for target the efforts in the combat to the water meter under-registration. The use of domestic roof tanks is responsible for the reduction of the water supply flow rates to the houses, causing the water meters to work with flows smaller than the ones that would occur in a water system supplied directly from the water distribution network. The control of the level of these roof tanks usually is done by float valves, which are flow valves with discharge proportional to the tank water level. In this work, a study was carried out aiming to establish the influence of the different types of the float valves, used in the control of the levels of the domestic roof tanks. For this the house supply was simulated based on the curves of float valve and the water consumption by households. To determine the valve flow curves an experimental apparatus was set up which allowed to plot the flow rate curves as function of tank levels. The profile of household water consumptions was obtained from the record of flow consumed in homes directly supplied, using data loggers. The curves of errors of the measuring meters used in homes were raised in the laboratory of CAESB. Based on the obtained in the simulations, it was possible to estimate the under-registration caused by low flow rates through the valves, and to analyze the effect of different combinations between the types of the valves tested, the consumption profiles and the meter errors. The results showed that the under-registration caused by the float valves can be aggravated by the combination of the consumption profile, type of tank and accuracy of meters used. The use of different diameters and valve brands showed a lower small influence in under-registration.
15

Padrão quali-quantitativo do descarte de águas residuárias em áreas carentes: um estudo no Alto do Bom Viver em Salvador.

Assunção, Dilma Maria Santos January 2005 (has links)
Submitted by Edileide Reis (leyde-landy@hotmail.com) on 2013-04-11T15:42:34Z No. of bitstreams: 1 Dilma.pdf: 7226288 bytes, checksum: 9f18d82cc7f0093b4276e7317a5ea5af (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-04-13T19:57:17Z (GMT) No. of bitstreams: 1 Dilma.pdf: 7226288 bytes, checksum: 9f18d82cc7f0093b4276e7317a5ea5af (MD5) / Made available in DSpace on 2013-04-13T19:57:17Z (GMT). No. of bitstreams: 1 Dilma.pdf: 7226288 bytes, checksum: 9f18d82cc7f0093b4276e7317a5ea5af (MD5) Previous issue date: 2005 / Discorre-se sobre o volume de água residuária, expresso em lâmina, descartado pela população que ocupa alguns dos assentamentos carentes ocorrentes nas partes altas das encostas e taludes de corte de Salvador. Utiliza-se para tal, como exemplo, um sítio do Subúrbio Ferroviário de Salvador conhecido como Alto da Boa Vista do Lobato. Em geral, tais assentamentos dispõem de abastecimento de água mas não dispõem de sistemas de esgotamento. Como consequência, as águas consumidas pela população retornam exoravelmente ao ambiente e são descartadas de modo concentrado e não disciplinado em um ou dois pontos da crista do talude. Discorre-se também, de um modo geral, acerca da taxa de ocupação de assentamentos que iguala ou faz essa lâmina superar a lâmina anual total precipitada pela chuva. Em adição, compara-se quantitativamente e se realça as diferenças associadas à intensidade, à duração e à freqüência das lâminas precipitadas pela ocupação e pela chuva. Conclui-se que as lâminas anuais descartadas pela população são surpreendentemente elevadas, comparáveis às precipitações pluviométricas e,quando o lote unidomiciliar alcança ou é inferior a cerca de 70 a 100 metros quadrados, a lâmina descartada pela população iguala-se ou supera a precipitação pluviométrica - a depender do ano hidrológico. Apoiando-se em conceitos relacionados à hidrologia e à infiltração, bservou-se que, em períodos de baixa precipitação pluviométrica, a lâmina diária gerada pela população que infiltra no subsolo tende a ser menor que a evapotranspiração. Já nos períodos de chuva intensa esta lâmina tende a ser da ordem do centésimo das lâminas geradas pelas chuvas intensas, portanto desprezível. Em ambos os períodos, as vazões geradas pela população e descartadas nas cristas dos taludes, de modo concentrado e pontual, são muito baixas em termos absolutos e desprezíveis quando comparadas às vazões geradas pela chuva. Não alcançam valores capazes de sobrecarregar os sistemas rudimentares de drenagem existentes, ou gerar erosões nas faces dos taludes, ou inundar as partes baixas do relevo. Podem, entretanto, infiltrar-se sistemática e continuamente por pontos da face do talude, sobretudo se o mesmo tiver sido cortado e exposto camadas subjacentes mais permeáveis, tal como ocorre nas encostas de solos residuais que são antropizadas por toda a cidade, criando pré-condições favoráveis à ocorrência de escorregamentos. / Salvador
16

Biogas production potential from kraft pulp mill sludge / Potencial de produção de biogás a partir de lodo de celulose kraft

Lopes, Alice do Carmo Precci 28 March 2017 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-30T13:10:23Z No. of bitstreams: 1 texto completo.pdf: 2018178 bytes, checksum: f542263170df07213000e3e4bebf72ed (MD5) / Made available in DSpace on 2017-05-30T13:10:23Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2018178 bytes, checksum: f542263170df07213000e3e4bebf72ed (MD5) Previous issue date: 2017-03-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O processo de fabricação da polpa celulósica kraft demanda elevada quantidade de água e energia. Embora a indústria gere parte de sua própria energia pela queima do licor negro na caldeira de recuperação e biomassa residual na caldeira de biomassa, a indústria ainda é dependente de energia elétrica e combustíveis fósseis adicionais. Devido ao aumento da tarifa de energia, a indústria de celulose tem sido motivada a aumentar sua eficiência energética, tornando-se autossuficiente. A produção de biogás a partir do lodo gerado na estação de tratamento de efluentes da indústria constitui uma potencial alternativa de gerenciamento dos resíduos e produção de energia. O objetivo principal desta dissertação foi avaliar o potencial da produção de biogás a partir dos lodos primário e secundário provenientes da indústria de celulose kraft branqueada. A dissertação foi estruturada em 5 Capítulos desenvolvidos em forma de artigos científicos. O Capítulo 1 apresentou uma revisão de literatura sobre os processos de produção de celulose kraft e de biogás, bem como um panorama sobre legislações brasileiras relacionadas à implantação de biodigestores. Foi concluído que há pouco estudo relativo à digestão anaeróbia de lodo de celulose kraft. Adicionalmente, apesar de o Brasil apresentar um grande potencial de produção de biogás, o país ainda carece de incentivos governamentais no setor. O Capítulo 2 objetivou (i) identificar a melhor relação substrato/inóculo (2/1, 1/1 e 0.4 g VS substrato /g VS inóculo ); (ii) identificar o melhor tipo de inóculo (lodo de UASB ou lodo de UASB + estrume); e (iii) estimar o potencial de substituição da energia elétrica demandada pelo sistema de aeração da estação de tratamento de efluentes da indústria de celulose kraft branqueada a partir do biogás produzido. Para tanto, foram utilizados como substratos o lodo primário (PS), lodo secundário (SS) e a mistura de ambos (MIX). Os resultados mostraram que o lodo secundário possuiu maior potencial de produção de biogás para uma relação 1/1 g VS substrato /g VS inóculo , utilizando lodo de UASB como inóculo. O estrume aumentou a produção de metano do lodo primário para relação S/I 1/1, porém pré-tratamentos devem ser testados de modo a aumentar a biodegradabilidade do substrato. Por fim, o biogás produzido apresentou potencial de substituir 23% daxi demanda de energia elétrica da estação de tratamento de efluentes. O Capítulo 3 objetivou (i) estimar o potencial de produção de biogás em condições termofílicas a partir do PS, SS e MIX; (ii) calibrar o modelo de digestão anaeróbia desenvolvido por Rajendran et al. (2014); e (iii) determinar a melhor composição do lodo e a influência de adição de nitrogênio no sistema de digestão anaeróbia a partir de simulações numéricas. Foi identificado que (i) a máxima produção de metano foi atingida pelo lodo secundário em 30 dias (46.9 NmL CH4/g VS); (ii) o modelo de digestão anaeróbia foi aplicável para lodo de celulose kraft após ajustes; (iii) a melhor composição de lodo foi de 21.62% de carboidratos, 61,67% de lipídeos e 16.72% de proteínas. A adição de nitrogênio aumentou a produção de metano para o PS e o MIX, mas reduziu para o SS. Os Capítulos 4 e 5 foram desenvolvidos por estudantes intercambistas como parte do programa Living Lab Biobased Brazil. Os objetivos do Capítulo 4 foram ajustar o modelo de Rajendran et al. (2014) para a condição mesofílica e simular o uso do biogás em forma de eletricidade e calor. A partir da simulação foi possível produzir 88 GJ/d de calor e 148 kW de potência elétrica. Além disso, a partir do ajuste do modelo de Rajendran et al. (2014) para a condição mesofílica, foram propostas melhorias para o modelo. Por fim, o Capítulo 5 objetivou apresentar potenciais alternativas para o gerenciamento do lodo de celulose kraft pós-digestão anaeróbia, utilizando a ferramenta de Análise de Multi-Critério simplificada. A partir das alternativas avaliadas (aterro sanitário, aplicação no solo, compostagem, incineração, pirólise/gaseificação e produção de algas), a compostagem se apresentou como a melhor opção. / The kraft pulping process is energy intensive. Although the mill generates part of its own energy by burning the black liquor in the recovery boiler and wooden biomass in the biomass boiler, it still relies on additional electricity and fossil fuel sources. Due to an energy price increase, the pulp industry has been driven to optimize its energy efficiency and self-sufficiency. One attractive industrial opportunity is to produce biogas from sludge using the anaerobic digestion technology. Thus, the main objective of this dissertation was to evaluate the potential of biogas production from bleached kraft pulp mill primary and secondary sludges. The dissertation was structured in 5 Chapters written as scientific papers. Chapter 1 presented a literature review about kraft pulp mills, biogas production, and legislations related to the implantation of biodigesters. It was concluded that there are still very few studies related to the anaerobic digestion of kraft pulp mill sludges. Additionally, although Brazil has great potential for biogas production, the country still faces barriers related to political incentives. Chapter 2 aimed at (i) identifying the best substrate to inoculum ratio (2/1, 1/1, and 0.4 g VS substrate /g VS inoculum ); (ii) identifying the best inoculum type (UASB sludge and UASB sludge + cow dung); and (iii) estimating the potential of substituting the electricity demand of the mill’s effluent treatment plant (ETP) aeration system. The substrates used consisted of primary (PS) and secondary (SS) sludges, and the mixture (MIX) between PS and SS. The results showed that the SS presented the highest methane production, with an optimal ratio of 1 g VS substrate /g VS inoculum using UASB sludge as inoculum. Cow dung increased the methane production of the PS for S/I = 1/1, but pre-treatment of PS should be tested to increase the substrate biodegradability. Finally, the methane yield led to a potential substitution of 23% of the ETP electricity demand. Chapter 3 aimed to (i) estimate potential biogas production under thermophilic conditions for the same substrates; (ii) calibrate the anaerobic digestion model developed by Rajendran et al. (2014); and (iii) simulate the best sludge composition and the influence of nitrogen addition on anaerobic digestion system. It was found that the (i) the maximum methane yield was achieved with theix secondary sludge at 30 days (46.9 NmL CH4/g VS); (ii) the applied anaerobic digestion model was applicable for the kraft pulp mill sludge after minor adjustments; (iii) optimal sludge composition was found to be 21.62% carbohydrates, 61.67% lipids and 16.72% proteins. The addition of nitrogen increased the methane yield for PS and MIX, but decreased it for SS. Chapters 4 and 5 were the result of work developed by bachelor exchange students as part of the Living Lab Biobased Brazil Program. Chapter 4 aimed to adjust the Rajendran et al. (2014) model for mesophilic conditions and simulate biogas use in the form of electricity and heat. From the simulation, a potential heat production of 88 GJ/d and electric power of 148 kW was found. From Chapter 4, possibilities for improving the Rajendran et al. (2014) model were proposed. Finally, Chapter 5 aimed at giving an insight into the possible alternatives for managing the anaerobically digested kraft pulp mill sludge using a simplified Multi- Criteria Decision Analysis tool. From the analyzed alternatives (landfill, land application, composting, incineration, pyrolysis/gasification and algae production), composting appeared to be the most suitable alternative.
17

Adsorção de metais tóxicos em efluente aquoso usando pó da casca de coco verde tratado / Adsorption of toxic metals in aqueous effluent using powder of green coconut husk treated

Sousa, Francisco Wagner de 04 1900 (has links)
SOUSA, F. W. de. Adsorção de metais tóxicos em efluente aquoso usando pó da casca de coco verde tratado. 2007. 105 f. Dissertação (Mestrado em Engenharia Civil. Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2007. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-03-06T16:03:38Z No. of bitstreams: 1 2007_dis_fwsousa.pdf: 1043023 bytes, checksum: be06cfb69adcfb4b595716b279d0505c (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-03-06T16:04:27Z (GMT) No. of bitstreams: 1 2007_dis_fwsousa.pdf: 1043023 bytes, checksum: be06cfb69adcfb4b595716b279d0505c (MD5) / Made available in DSpace on 2012-03-06T16:04:27Z (GMT). No. of bitstreams: 1 2007_dis_fwsousa.pdf: 1043023 bytes, checksum: be06cfb69adcfb4b595716b279d0505c (MD5) Previous issue date: 2007-04 / The solid agroindustry residues are most studied, due its abundance and low cost for recovery of wastewater industry using process of adsorption. In this work was used the green coconut shell powder as adsorbent for the heavy metals removal from wastewater aqueous produced for electroplating industries localized in Juazeiro do Norte (Ceara-Brazil). Adsorption systems in batch and column were studied. In the first step of this work was investigated the chemical treatment, the particle size effect, adsorbent concentration and pH effect. The results showed that the treatment employed in the green coconut shell powder with NaOH 0.1mol.L-/3h was the most efficient. This material was used for the metals adsorption study with the following characteristic: particle size ranged 60-99 mesh, adsorbent concentration (40g/L) and pH 5.0. The kinetic study indicated that the adsorption equilibrium multielementary were achieved in 5 minutes (pH 5.0) and followed a pseudo-second order model. The maximum capacities of adsorption observed for the multielementary system were: 7.89; 1.72; 3.24; 13.26 and 5.09mg/g to Pb+2; Ni+2; Cd+2; Zn+2 and Cu+2, respectively. In the second step of the work were carried out experiments to otimization of the operational parameters of the column. The results showed that for a flow rate of 2mL/min and height bed of 10cm there is an increased on the metals removal. The breakthrough curves investigated to a system multi indicated that the order for column capacity was the follow: Cu+2 > Pb+2 >Cd+2 > Zn+2 > Ni+2. The parameters optimization of the column obtained with the synthetic effluents were applied in a real sample contained (Ni+2, Zn+2 and Cu+2) which showed that the toxic ions removal increased at pH 5.0. The desorption of the metals ions retained on the column was efficient using the HNO3 1,0mol.L- as eluent. The tests of recycling of the column showed that the adsorbent can be used only a cycle. / Os resíduos sólidos agroindustriais são bastante estudados devido a sua abundância e baixo custo para a recuperação de efluentes industriais utilizando processos de adsorção. Neste trabalho utilizou-se o pó da casca de coco verde como adsorvente para remoção de metais pesados de efluentes aquosos produzidos por indústrias de eletrodeposição localizadas em Juazeiro do Norte (Ceará-Brasil). Sistemas de adsorção em batelada e coluna foram estudados. Na primeira etapa deste trabalho foram investigados o tratamento químico, o efeito da granulometria, o efeito da concentração do adsorvente e o efeito do pH. Os resultados mostraram que o tratamento aplicado no pó da casca de coco verde com NaOH 0,1mol.L-/3h foi mais eficiente. Este material foi usado para o estudo de adsorção dos metais com as seguintes características: faixa de granulometria de 60-99 mesh, concentração de 40g/L e pH 5,0. O estudo de cinética indicou que o equilíbrio de adsorção multielementar foi atingido em 5 minutos (pH 5,0) e segue cinética de pseudo-segunda ordem. As capacidades máximas de adsorção observadas nos estudos de equilíbrio para um sistema multielementar foram: 7,89; 1,72; 3,24; 13,26 e 5,09 mg/g para Pb+2; Ni+2; Cd+2; Zn+2 e Cu+2, respectivamente. Na segunda etapa da pesquisa foram realizados experimentos para otimização das condições operacionais da coluna. Os resultados mostraram que uma velocidade de fluxo de 2mL/min e uma altura de 10cm do leito aumentaram o percentual de remoção para todos os metais tóxicos estudados. As curvas de ruptura investigadas para um sistema multielementar indicaram que a ordem das capacidades de adsorção foi a seguinte: Cu+2 > Pb+2 > Cd+2 > Zn+2 > Ni+2. A aplicabilidade dos estudos de coluna numa amostra real oriunda de empresas de galvanoplastia contendo: Ni+2, Zn+2 e Cu+2 mostraram que a remoção dos íons tóxicos aumenta quando o pH da solução é 5,0. A dessorção dos íons metálicos, retidos na coluna, foi eficiente usando HNO3 1,0mol.L- como eluente. Os ensaios de reciclagem da coluna mostraram que o adsorvente pode ser utilizado apenas num ciclo.
18

Aproveitamento de vísceras de tilápia para produção de biodiesel / Use of tilapia offal for biodiesel production

Dias, Fernando Pedro 09 October 2009 (has links)
DIAS, F. P. Aproveitamento de vísceras de tilápia para produção de biodiesel. 2009. 106 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-05T16:40:57Z No. of bitstreams: 1 2009_dis_fpdias.pdf: 1599401 bytes, checksum: 740952bdbdcb363e5e4403f19821d3ad (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-09T19:15:42Z (GMT) No. of bitstreams: 1 2009_dis_fpdias.pdf: 1599401 bytes, checksum: 740952bdbdcb363e5e4403f19821d3ad (MD5) / Made available in DSpace on 2016-05-09T19:15:42Z (GMT). No. of bitstreams: 1 2009_dis_fpdias.pdf: 1599401 bytes, checksum: 740952bdbdcb363e5e4403f19821d3ad (MD5) Previous issue date: 2009-10-09 / Stimulate the consumption of alternative energy translates into an undeniable factor in the development of responsible nations, aiming primarily to preserve and conserve the environment as well as the reductions of climate change the presents and futures. The biodiesel industry is a good option for market exploitation of oil extracted from the waste generated by industry of fish. Were collected and extracted oil from the offal of tilapia and this has been produced biodiesel using ethyl alcohol and the methyl alcohol transesterification reaction with NaOH. The extraction of hot indirect (cooking) was satisfactory conditions: 70 to 80ºC, atmospheric pressure, constant mechanical agitation and 45 minutes. The average yield of the extraction process of oil was 50, 3 ± 3,3% over the mass of the offal and the yield of biodiesel produced in both routes (ethanol and methanol) were 89,5 ± 0,3% and 96,9 ± 0,2% respectively. The parameters of certain biodiesel specification are within the limits required by the ANP. Fractionation of oil / fat tilapia resulted in two distinct fractions with the following percentages: 35,1 ± 0,3% of solid fraction (stearin) and 64,4 ± 0,0% of liquid fraction (olein). The fatty oil offal of tilapia were quantified using gas chromatography through the ethyl and methyl ester of fatty acids from biodiesel. The oil from fish offal of tilapia consists of the following fatty acids: 37,2% of oleic acid, 12,2% linoleic acid, 4,89% of palmitoleic acid, 1,79% linolenic acid and saturated with 28, 6% palmitic acid, 5,76% stearic acid, 3,57% of myristic acid in quantity majority / Estimular o consumo de energias alternativas se traduz num incontestável fator para o desenvolvimento responsável das nações, objetivando principalmente a preservação e a conservação do meio ambiente, bem como, as reduções das alterações climáticas atuais e futuras. A indústria de biodiesel representa uma boa opção de mercado para aproveitamento do óleo extraído a partir dos resíduos gerados pela indústria de beneficiamento de peixe. Foram coletadas e extraídas o óleo de vísceras de tilápia e deste foram produzidos os biodiesel metílico e etílico utilizando a reação de transesterificação alcalina com NaOH. A extração a quente indireto mostrou-se satisfatório nas condições de: 70 à 80ºC, pressão atmosferica, agitação mecânica constante e 45 minutos. O rendimento médio do processo de extração de óleo foi de 50,3 ± 3,3% em relação a massa das vísceras e o rendimento de biodiesel obtido em ambas rotas (etílica e metílica) foram de 89,5±0,32% e 96,9±0,17% respectivamente. Os parâmetros de especificação do biodiesel determinados encontram-se dentro dos limites exigidos pela ANP. O fracionamento de óleo/gordura de tilápia resultou em duas frações distintas com seguintes percentagens: 35,12 ± 0,29% de fração sólida (estearina) e 64,35 ± 0,02 % de fração líquida (oleina). Os ácidos graxos do óleo de vísceras de tilápia foram quantificados utilizando a técnica de cromatografia gasoso através dos etil e metil ésteres de ácidos graxos do biodiesel. Os ácidos graxos identificados e quantificados foram: 37,2% de ácido oléico, 12,2% de ácido linoléico, 4,89% de ácido palmitoleico, 1,79% de ácido linolênico e os saturados com 28,6% de ácido palmítico, 5,76% de ácido esteárico, 3,57% de ácido mirístico em quantidade majoritário
19

Proposta de modelo para escolha de tecnologias de tratamento de água em pequenas comunidades do semiárido / Proposed model for selection of water treatment technology for small communities of the semi-arid

Ponte, Fernando Victor Galdino 10 February 2011 (has links)
PONTE, F. V. G. Proposta de modelo para escolha de tecnologias de tratamento de água em pequenas comunidades do semiárido. 2011. 223 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-05T16:55:41Z No. of bitstreams: 1 2011_dis_fvgponte.pdf: 9659720 bytes, checksum: 88cf889a3646c591b5ab97d31d14178d (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-17T16:35:54Z (GMT) No. of bitstreams: 1 2011_dis_fvgponte.pdf: 9659720 bytes, checksum: 88cf889a3646c591b5ab97d31d14178d (MD5) / Made available in DSpace on 2016-05-17T16:35:54Z (GMT). No. of bitstreams: 1 2011_dis_fvgponte.pdf: 9659720 bytes, checksum: 88cf889a3646c591b5ab97d31d14178d (MD5) Previous issue date: 2011-02-10 / The water supply systems in Ceará semiarid are deficient with regard to water quality. The water treatment in communities are not being very efficient, since there is no standardization of water treatment plants in relation to the quality of the raw water that is captured. Therefore, it was developed a simplified model of choice selection of water treatment technologies for small communities, which was developed using Excel 2007, where you can make a correct choice of the treatment plant that will supply water to a location. The model consists of two steps. In the first stage are the criteria for exclusion, since it is a simplified model and parameters such as hardness, chloride, fluoride, among others need to be well analyzed, due to their treatment are not feasible for small rural communities and are not in the model‟s result. The second step is the selection of technologies for water treatment itself, on which selecting the source and its characteristics, the model will be able to bring the best result for an effective treatment. In addition to the model‟s results are the hydraulic design and the plant water treatment plants chosen. The technologies used were the Complete Cycle, the Direct Ascendant Filtration, the Double Filtration and Oxidation followed by rapid Ascendant Filtration. The selection criteria were included by a bibliographic review of established authors in water treatment and the criteria for choosing the technology that removes iron were developed in the pilot plant at ETA GAVIÃO. / Os pequenos sistemas de abastecimento de água no semiárido cearense apresentam uma deficiência no que diz respeito à qualidade. O tratamento da água nestas comunidades não está sendo bem eficiente, já que não há uma metodologia para escolha da tecnologia apropriada para o tratamento de água em função da qualidade da água bruta. Tendo em vista essa problemática, foi desenvolvido um modelo simplificado de escolha de tecnologia de tratamento de água para pequenas comunidades, utilizando o Excel 2007. O modelo tem duas etapas: Na primeira, encontram-se os critérios de exclusão, parâmetros tais como a dureza, os cloretos, o flúor, dentre outros. Devido seu tratamento ser tecnicamente inviável em pequenas comunidades rurais, não foram considerados no resultado do modelo. A segunda etapa é a de seleção das tecnologias de tratamento de água propriamente dito, onde ao se selecionar o manancial e algumas de suas características, o modelo será capaz de trazer o melhor sistema para um tratamento eficiente. Juntamente com o resultado do modelo, encontram-se os dimensionamentos hidráulicos e as plantas das estações de tratamento de água propostas. As tecnologias usadas foram o Ciclo Completo, a Filtração Direta Ascendente, a Dupla Filtração e a Oxidação seguida de Filtração rápida Ascendente. Os critérios de seleção foram definidos através de revisão bibliográfica, com exceção dos critérios para escolha da tecnologia para remoção de ferro, que foram encontrados em corridas experimentais realizadas na instalação piloto existente na ETA GAVIÃO.
20

Índice de concordância e risco fuzzy na avaliação do desempenho de sistemas de lagoas de estabilização / Agreement index and fuzzy risk for the evaluation of waste stabilization pond systems

Silva, Fernando José Araújo da 18 October 2010 (has links)
SILVA, F. J. A. Índice de concordância e risco fuzzy na avaliação do desempenho de sistemas de lagoas de estabilização. 2010. 161 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-04T19:37:19Z No. of bitstreams: 1 2010_tese_fjasilva.pdf: 9029880 bytes, checksum: 570f538eedef973cc9ff09a4de221955 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-17T17:32:46Z (GMT) No. of bitstreams: 1 2010_tese_fjasilva.pdf: 9029880 bytes, checksum: 570f538eedef973cc9ff09a4de221955 (MD5) / Made available in DSpace on 2016-05-17T17:32:46Z (GMT). No. of bitstreams: 1 2010_tese_fjasilva.pdf: 9029880 bytes, checksum: 570f538eedef973cc9ff09a4de221955 (MD5) Previous issue date: 2010-10-18 / In the present study fuzzy arithmetic via triangular fuzzy numbers (TFNs) was applied to compute Fuzzy Agreement Index (FAI) and Fuzzy Risk (FR) for the evaluation of operational aspects, performance and effluent quality in 14 full-scale waste stabilization pond plants (6 primary facultative ponds – PFPs and 8 pond series- PSs) treating domestic sewage. Findings showed that fuzzy logic is an attractive approach for the evaluation of the performance of wastewater treatment plants and their environmental compatibilities. The study also provided a better understanding of operational aspects of waste stabilization ponds. Except for two pond systems (PFP4 and PS8) the FAI in PFPs and PSs showed that they operated on average 81.3 and 86.3% of the time below the value stipulated in their original designs. Results indicated average potential increments of 74.7 and 84.5% in influent flow rates to PFPs and PSs, respectively. With respect to organic load () FAI numbers indicated possible increases of 91.8 and 71.9% in PSs and PFPs respectively. In the case of the regulatory standards the FAI applied to effluent quality had best results for DO (PSs = 0.945 and PFPs = 0.867). In general pond series had higher numbers for FAI than PFPs. The fuzzy risk regarded to overloading (organic and hydraulic) was higher in pond series. Comparatively, systems PFP4 and PS8 showed higher fuzzy risk of overloading because these plants operated close to the design numbers. The FR on performance analysis showed that all ponds plants had actual performance slightly below that expected and reported by the literature. The lowest FR values were observed in pond series. On the performance analysis the highest fuzzy risk numbers were for TSS (0.929 in PFPs and 0.903 in PSs), followed by unfiltered COD (0.846 in PFPs and 0.677 in PSs). As expected, fuzzy risk regarded to the violation of environmental standards was higher in PFPs. In pond series by increasing number of cells FR was lower. Positive linear correlations (at a significance level of 95%) showed that lower content of BOD and COD (unfiltered samples), and TSS implied in lower FR with respect to termotolerant coliform concentrations (TTFC). Correlations between FR of pH and TTFC were negative. A Fuzzy Performance Index (FPI) was proposed to compare effluent quality with respect to the environmental standard regulation. The model considered a scale (1-18) based on the following parameters: BODf, CODf, TSS, TAN, DO and TTFC. The results showed the following order: FPI PFP3 (2.09) < FPI PFP2 (2.15) < FPI PFP4 (2.30) < FPI PFP5 (3.49) < FPI PFP1 (3.62) < FPI PFP6 (4.96) < FPI PS5 (9.59) < FPI PS8 (9.67) < FPI PS4 (9.72) < FPI PS3 (10.01) < FPI PS1 (10.38) < FPI PS2 (13. 57) < FPI PS6 (15.49) < FPI PS7 (15.69). The analysis of FR for helminth eggs showed that for a marginal fuzzy risk of 10% pond systems would require a HRT of 28.8 days for oH ≤ 1.0 egg/L, and 38.0 days for oH ≤ 0.1 egg/L. In two series (LS5 and LS8) the FAI and FR with respect to effluent quality from each pond component provided distinctions imposed by the configuration and operational status in each of these plants. Along pond cells in these series BOD and TAN surface removal rates (r) were represent by TFNs. These fuzzy numbers showed negative surface removal rates. They offered an anomalous interpretation for pollutant generation via physical or biotic means. The probable and reasonable cause was the asynchrony between affluent and effluent concentrations, associated with fluctuations in flow rates. Climatic factors and hydraulic behavior of ponds might also influence this. / No presente trabalho foi empregada a aritmética fuzzy com NFTs para o cálculo do Índice de Concordância Fuzzy (ICF) e do Risco Fuzzy (RF), com fins de análise de aspectos operacionais, desempenho e qualidade dos efluentes de 14 ETEs do tipo lagoas de estabilização (6 lagoas facultativas primárias - LFPs e 8 séries- LSs) em escala real, tratando esgotos domésticos. A lógica fuzzy provou ser um recurso eficiente na avaliação do desempenho de ETEs e suas compatibilidades ambientais. O estudo propiciou também uma melhor compreensão do funcionamento operacional de lagoas de estabilização. Exceto por dois sistemas (LFP4 e a LS8) o ICF mostrou que as LFPs e LSs operaram em média 81,3 e 86,3% do tempo, abaixo do valor estipulado em projeto. Nestas seriam possíveis incrementos médios de vazão de 74,7 e 84,5%, respectivamente. Quanto às cargas orgânicas afluentes () os valores de ICF mostraram a possibilidade de acréscimos de 91,8 e 71,9%, para as LSs e LFPs, respectivamente. Sobre a qualidade dos efluentes, o OD obteve os maiores valores de ICF (LSs = 0,945 e LFPs = 0,867). Os valores de ICF para qualidade do efluente tratado foram mais elevados nas séries, com maior concordância fuzzy com as normas ambientais. O risco fuzzy concernente à sobrecarga (orgânica e hidráulica) foi maior nas séries. Individualmente, os sistemas LFP4 e LS8 apresentaram maior risco difuso de sobrecarga, por operarem sob condições próximas às estabelecidas em projeto. O RF para análise de desempenho mostrou que as ETEs tiveram perfomance um pouco abaixo do que observa a literatura técnica. Os menores valores de RF foram observados nos sistemas em série. O risco difuso para não atendimento das expectativas de desempenho foi maior em relação a SST (0,929 nas LFPs e 0,903 nas LSs), seguido de amostras não filtradas de DQO (0,846 nas LFPs e 0,677 nas LSs). Na violação das normas ambientais o RF também foi maior nas LFPs. Observou-se que nas séries, quanto maior o número de lagoas menor o RF. Correlações lineares positivas (nível de significância de 95%) mostraram que quanto menor o conteúdo de DBO e DQO (amostras não filtradas), e de SST, menor o risco difuso em relação a CTm. No caso do RF para pH e CTm a correlação foi negativa. Foi estabelecido um Índice de Desempenho Fuzzy (IFD) para lagoas de estabilização, para comparar a qualidade dos efluentes das ETEs. O modelo propôs uma escala (1 a 18) baseada nos parâmetros DBOf, DQOf, SST, AMT, OD e CTm. Os resultados apresentaram o seguinte ordenamento: IFD LFP3 (2,09) < IFD LFP2 (2,15) < IFD LFP4 (2,30) < IFD LFP5 (3,49) < IFD LFP1 (3,62) < IFD LFP6 (4,96) < IFD LS5 (9,59) < IFD LS8 (9,67) < IFD LS4 (9,72) < IFD LS3 (10,01) < IFD LS1 (10,38) < IFD LS2 (13,57) < IFD LS6 (15,49) < IFD LS7 (15,69). A análise do RF para ovos de helmintos mostrou que para uma margem e risco difuso de até 10% seria necessário um TDH de 28,8 dias com oH ≤ 1,0 ovo/L e 38,0 dias com oH ≤ 0,1 ovo/L. Em duas séries (LS5 e LS8) o cálculo de ICF e RF em relação à qualidade do efluente de cada lagoa componente permitiu observar distinções impostas pela configuração e condição operacional de cada uma dessas ETEs. Nas citadas séries os NFTs foram empregados para avaliar r de DBO e AMT. As representações mostraram taxas de remoção superficial com valores negativos, que ofereceram uma interpretação anômala de geração de poluente por via física ou biótica. A causa foi a assincronia entre as concentrações afluentes e efluentes, associadas à flutuações nas vazões, e, de forma indireta, a fatores climáticos e hidráulica das lagoas.

Page generated in 0.0938 seconds