• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 198
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 199
  • 199
  • 69
  • 58
  • 56
  • 56
  • 52
  • 48
  • 37
  • 35
  • 35
  • 33
  • 31
  • 26
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Potencial de reciclagem do lixo urbano da cidade de Alfenas, MG

Paoliello, Jose Roberto 18 July 2018 (has links)
Orientador : Roberto Feijo de Figueiredo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-18T22:01:40Z (GMT). No. of bitstreams: 1 Paoliello_JoseRoberto_M.pdf: 8930801 bytes, checksum: 7eecff46ab3e6755c4e2fa705695e29b (MD5) Previous issue date: 1993 / Resumo: Este trabalho foi desenvolvido com o objetivo de se avaliar o potencial de reciclagem do lixo urbano da cidade de Alfenas (MG). Para sua realização foi necessário se proceder a uma caracterização do lixo coletado, avaliação das quantidades totais de lixo coletado, bem como um levantamento do total atualmente reciclado através dos sucateiros. Com os dados obtidos da caracterização, das quantidades coletadas, produzidas e recicladas informalmente, procedeu-se a um balanço de massa calculando-se a produção total diária tanto para a coleta pública, para a coleta informal e também para a produção total diária resultante. Foi também calculada a produção per capita para a coleta pública, para a coleta informal e par a produção total diária, obtendo-se 0,38 kg/hab.d. Em seguida foi feita a estimativa da percentagem reciclada, atualmente, para o lixo da coleta municipal, chegando-se ao valor de 2 %. Igualmente, avaliou-se a percentagem reciclada correspondente à coleta informal, obtendo-se o valor de 4,2 %. Com esses 2 (dois) valores chegou-se ao valor total de reciclagem atual que é de 6,2 %. Com base neste valor, na produção total diária de lixo e ainda na caracterização do lixo, estimou-se o potencial de reciclagem para a cidade de Alfenas (MG), chegando-se a um valor correspondente a 33 % da produção diária, (ton.) ou seja, 7,0 t/d. Este trabalho foi desenvolvido com o objetivo de se avaliar o potencial de reciclagem do lixo urbano da cidade de Alfenas (MG). Para sua realização foi necessário se proceder a uma caracterização do lixo coletado, avaliação das quantidades totais de lixo coletado, bem como um levantamento do total atualmente reciclado através dos sucateiros. Finalmente é feita uma sugestão para a gestão dos resíduos gerados na cidade de Alfenas (MG). Este trabalho foi desenvolvido com o objetivo de se avaliar o potencial de reciclagem do lixo urbano da cidade de Alfenas (MG). Para sua realização foi necessário se proceder a uma caracterização do lixo coletado, avaliação das quantidades totais de lixo coletado, bem como um levantamento do total atualmente reciclado através dos sucateiros / Abstract: The present work was developed with the purpose of assaying the potentiality of recycling the municioal solid wastes of Alfenas(MG). For so doing, it was necessary to characterize the collected solid wastes, to evaluate the total quantity of the collected garbage, and to survey the quantity which is currently recycled by the private garbage collectors. With the data obtained from the characterization, from the quantities collected, produced and unconventionally recycled, a balance of the was wade by calculating the total daily production both for the public collection and for the unconventional collection, as well as for the total daily production. The production "per capita" was also calculated for the public collection, for the unconventional collection and for the total daily production, with the result of 0,38 kgl capita.day. Then the current recycled production of the municipal solid waste collection was estimated in 2%. The percentage of the unconventional recycled production was equally estimated and reached 4,2%. The addition of these two values correspond to the total current recycling: 6,2%. Based on this percentage, on the total daily production, and on the characterization of the wastes, the potential of recyclin in Alfenas (MG) was estimated in 33 % of the daily production, or 7,0 metric. ton/day. A suggestion is finally proposed for the management of residues produced in Alfenas (MG) / Mestrado / Recursos Hidricos e Saneamento / Mestre em Engenharia Civil
52

Desenvolvimento de lagoas de maturação aquecidas com energia solar visando ao reuso de águas / not available

Andrade, Marcio Antonio Nogueira 10 November 2000 (has links)
O reuso de águas, por meto da utilização das águas residuárias tratadas, consiste em uma das estratégias para aumentar a disponibilidade e conservar os recursos hídricos, principalmente em regiões áridas e semi-áridas. Visando contribuir com este tema, estudou-se um tratamento terciário ele águas residuárias ele baixo custo, com o objetivo de obter efluente que satisfaça as diretrizes da OMS para reuso na agricultura sem restrições. Experimentos de campo foram realizados em Portugal, em uma pequena lagoa ele maturação (8 x 3 x 0,5 m) coberta com plástico de bolhas, flutuando sobre a água, para aquecê-la com a energia solar por efeito estufa e atingir combinações tempo-temperatura que possibilitem obter efluente com qualidade microbiológica para utilização na irrigação. Foram selecionadas metodologias para pesquisa de ovos de helmintos em águas residuárias brutas e tratadas, tendo sido adotado o método ela OMS-A. Este foi aprimorado com a adoção de um sedimentador para facilitar o trabalho de laboratório, quando utilizam-se amostras de águas residuárias tratadas. O sistema de aquecimento utilizado em Portugal não propiciou aumento na temperatura suficiente para alcançar a desejada remoção de coliformes fecais para uso na irrigação. A análise conjunta dos resultados obtidos nas instalações experimentais de Portugal, com os dados de outros dois campos de experimento, Tunísia e Jordânia, integrados ao mesmo projeto (AVICENNE), indica que a coberta plástica melhora o processo de tratamento de águas residuárias em lagoas de maturação, quando estas atingem maiores temperaturas. O aumento da temperatura e a exposição aos raios ultravioleta foram os principais fatores que contribuíram para a remoção de coliformes fecais nas lagoas de maturação. / Wastewater reuse, through the use of treated wastewater, consists in one of the strategies to increase the availability and conserve water resources, mainly in arid and semi-arid areas. Seeking to contribute with this theme, it was studied a low cost wastewater tertiary treatment with the objective of obtaining effluent that satisfies the guidelines of WHO for agriculture reuse without restrictions. Field experiments were accomplished in Portugal, in a small maturation pond (8 x 3 x 0,5 m) covered with bubble plastic, floating on the water, to heat it up with solar energy by greenhouse effect and to reach time-temperature combinations that facilitate the obtaining effluents with microbiological quality for irrigation reuse. Methodologies were selected for research of helminth eggs in wastewater and in the soil, having been adopted the WHO-A method. This method was improved with the adoption of a sedimentation chamber to facilitate the laboratory work, when samples of treated wastewater are used. The heating system used in Portugal didn\'t propitiate enough increase in the temperature to reach the whised removal of fecal coliforms for irrigation use. The analysis of the results obtained in the experimental facilities of Portugal, together with the data of another two experiment fields, Tunísia and Jordania, integrated into the same project (AVICENNE), indicates that lhe plastic cover improves the wastewater treatment in maturation ponds, when these reach higher temperatures. The increase temperature and the exposition time to ultraviolet rays, contributed to the removal of fecal coliforms in the maturation ponds.
53

Caracterização do efluente gerado no campus Poços de Caldas da Universidade Federal de Alfenas / Characterization of the effluent generated in Universidade Federal de Alfenas campus Poços de Caldas, MG

MENEZES, Leda Carolina Carvalho 04 July 2017 (has links)
Esse trabalho visou caracterizar o efluente gerado no campus Poços de Caldas da UNIFAL-MG, analisar estatisticamente como as características do efluente são influenciadas por diversas variáveis e definir valores de referência per capita. As análises laboratoriais foram feitas seguindo os métodos descritos no Standard Methods for the Examination of Water and Wastewater para determinação de demanda química de oxigênio (DQO), pH, cloretos, condutividade, nitrogênio amoniacal, sólidos totais (fixos e voláteis) e sólidos suspensos (fixos e voláteis). Além disso, foi utilizado um condutivímetro para determinação de sólidos dissolvidos. A vazão de esgoto no campus foi estimada através da medição do consumo de água. Os dados foram analisados estatisticamente utilizando análise de variância, teste de comparação de médias Scott-Knott teste T e testes de correlação. Os resultados mostram que DQO e sólidos dissolvidos variam de acordo com os dias da semana, enquanto pH, cloreto e condutividade não sofrem essa influência. Também foi verificado que não há diferenças entre os valores médios de pH do período letivo e de férias, enquanto DQO, cloreto e condutividade têm médias estatisticamente menores em férias do que em dias letivos. Ao longo de perfis temporais foi verificado que pH, DQO, sólidos totais (fixos e voláteis) e sólidos suspensos (fixos e voláteis) não têm médias estatisticamente diferentes ao longo do dia. Os testes de correlação demonstraram que a população acadêmica não interfere diretamente no pH e nas concentrações de DQO, sólidos totais (fixos e voláteis) e sólidos suspensos (fixos e voláteis), mas interfere na quantidade de água consumida no campus. Além disso, o número de refeições servidas pode interferir em alguns parâmetros. Considerando todas as análises realizadas, as médias encontradas foram (em mg/l) DQO: 625,38 ± 347,30, sólidos totais: 507,60 ± 207,30, sólidos totais voláteis: 311,90 ± 161,10, sólidos totais fixos: 205,00 ± 120,50, sólidos suspensos voláteis: 102,80 ± 82,90, sólidos suspensos fixos: 24,60 ± 0,43, nitrogênio amoniacal: 9,30 ± 4,99, sólidos dissolvidos: 399,05 ± 172,13, cloreto: 189,41 ± 78,09. Para o pH a média foi 7,07 ± 0,59 e para condutividade 787,89 ± 307,58 μS/cm. O volume estimado de geração de efluente no campus foi de 9,82 m³/dia. A determinação da carga per capita de cada parâmetro analisado mostrou-se inferior aos valores de referência encontrados na literatura para esgotos domésticos. Esse resultado reflete a importância da caracterização do efluente das diversas fontes geradoras, visando a melhor determinação do tratamento a ser empregado em cada caso. / This work aimed to characterize the effluent generated at the Poços de Caldas campus of UNIFAL-MG, to statistically analyse how the effluent characteristics are influenced by several variables and to define ​​per capita loadings. The laboratory analyses were done under the methods described in the Standard Methods for the Examination of Water and Wastewater were used to determine chemical oxygen demand (COD), pH, chlorides, conductivity, ammoniacal nitrogen, total solids (fixed and volatile) and suspended solids (fixed and volatile). In addition, a conductivitimeter was used to determine dissolved solids. The sewage flow on campus was estimated by measuring water consumption. Using generated data statistical analyses were taking using analysis of variance, mean comparison tests, T-tests and correlation trests.Results shows that COD and dissolved solids vary according to the days of the week, whereas pH, chloride and conductivity do not suffer this influence. It was also verified that there are no differences between the mean values ​​of the pH of the school and and this one of vacation period. COD, chloride and conductivity have statistically lower means in vacations than means in school days. pH, COD, total solids (fixed and volatile) and suspended solids (fixed and volatile) do not have statistically different means throughout the hours of the day. Correlation tests have shown that the academic population does not directly interfere with the pH and concentrations of COD, total solids (fixed and volatile) and suspended solids (fixed and volatile), but population interferes with the amount of water consumed on campus. In addition, the number of meals served can interfere with some characteristics. Considering all the analyses, the means found were (in mg / l) COD: 625.38 ± 347.30, total solids: 507.60 ± 207.30, total volatile solids: 311.90 ± 161.10, total fixed solid: 205.00 ± 120.50, volatile suspended solids: 102.80 ± 82.90, fixed suspended solids: 24.60 ± 0.43, ammoniacal nitrogen: 9.30 ± 4.99, dissolved solids: 399 , 05 ± 172.13, chloride: 189.41 ± 78.09. For the pH the mean was 7.07 ± 0.59 and for conductivity 787.89 ± 307.58 μS / cm. The estimated volume of effluent generation on campus was 9.82 m³ / day. The determination of the per capita load of each analysed parameter was lower than the reference values found in the literature for domestic sewage. This result reflects the importance of the characterization of the effluent for different generating sources, aiming at the best determination of the treatment to be used in each case.
54

Monitoramento e diagnóstico de conservação das águas do Rio Paraíba do Sul.

Amarilis Rangel Tavares 10 April 2006 (has links)
O presente trabalho tem por objetivo analisar o impacto causado pela urbanização e pela industrialização na qualidade das águas do trecho paulista do rio Paraíba do Sul, assim como, verificar as inter-relações existentes entre os diversos parâmetros de qualidade de água analisados. Para isto foram definidos nove postos de amostragem, com base em mapeamento de vetores de alteração da paisagem, os quais foram monitorados mensalmente entre dezembro/2001 e novembro de 2002. Os parâmetros de qualidade analisados foram temperatura da água, oxigênio dissolvido, pH, condutividade, clorofila a, sulfetos, fósforo total, fósforo total dissolvido, nitrato, nitrito, nitrogênio amoniacal, coliformes fecais e totais, cromo total e chumbo total. Foram analisados também os seguintes metais pesados no sedimento: níquel, ferro, manganês, cobre, cádmio, zinco e chumbo. Os resultados obtidos demonstraram que, entre as atividades antrópicas que estão acelerando a degradação ambiental da qualidade da água do rio, pode-se citar: a falta de tratamento de esgotos domésticos, principalmente nas cidades onde o rio corta trechos urbanos, como Guaratinguetá e Caçapava e o desmatamento das áreas marginais que causam o assoreamento e erosão. Com relação aos efluentes industriais os métodos utilizados para teste não possuíam resolução suficiente para diagnosticar sua real influência na qualidade da água. Em alguns pontos observou-se que o rio praticamente "morre" em função da carga de efluentes que receber diariamente. Apesar da grande carga de despejos no rio pode-se dizer que a sua capacidade de recuperação ainda é relevante, tendo em vista as melhores condições encontradas na última estação localizada em Queluz.
55

Influência do uso de sistemas de saneamento "in situ" na qualidade das águas de poços rasos e profundos.

Beatriz Helena Minari 01 November 2007 (has links)
O objetivo dessa pesquisa foi avaliar a influência do uso de sistemas de saneamento "in situ" na qualidade das águas extraídas de poços rasos e profundos localizados no bairro 22 de Abril, Jacareí São Paulo, Brasil. A metodologia empregada baseou-se em coletas periódicas de amostras de água dos poços monitorados e subseqüentes análises de nitratos, nitritos, coliformes fecais e totais. Os resultados das análises químicas foram validados por meio da utilização de modelos matemáticos (software Visual MODFLOW 4.2) empregados no estudo dos efeitos do fluxo e dispersão das plumas de contaminante ao redor das fossas sépticas distribuídas no local. As análises indicaram contaminação da água subterrânea extraída do poço raso, entretanto, apesar das precárias condições de instalação e manutenção das fossas rudimentares e da elevada densidade das fossas por unidade de área, a água do poço profundo não apresentou contaminação química e/ou biológica relacionadas ao sistema de saneamento "in situ".
56

Simulação da qualidade da água subterrânea no aterro sanitário de Taubaté.

Maria de Fátima de Pinho 00 December 1997 (has links)
Nesta dissertação é aplicado o modelo numérico bi-dimensional UNMOC (Charbeneau 1990) para avaliar o impacto do aterro sanitário de Taubaté sobre a qualidade das águas subterrâneas. UNMOC é um modelo numérico e analítico de fluxo e transporte de massa que combinado com dados químicos e cargas hidráulicas foi simultaneamente aplicado no aterro novo e no aterro inativo de Taubaté, numa área total de 265.700m2. Sabe-se que o amônio, cloreto, sódio, magnésio e cálcio contribuem para o aumento da mineralização da água subterrânea na área. Amônio e cloreto tornam-se indicadores particulares da poluição do lixo municipal. A evolução da pluma de de contaminação causada pelo aterro sanitário de Taubaté foi modelada através da substância cloreto, para o ano corrente e para os próximos 5 e 10 anos, mostrando que nenhuma contaminação pela água subterrânea será detectada próxima do rio. Outras simulações hipotéticas foram realizadas, mostrando a versatilidade do modelo para vários tipos de condutividade e espessuras do aquífero. Os resultados e validades da aplicação serão discutidos.
57

Análise da disponibilidade da rede automática de monitoramento da qualidade do ar e seus reflexos no licenciamento ambiental realizado em São Paulo

José Carlos de Moura Xavier 03 May 2011 (has links)
A qualidade do ar no estado de São Paulo é acompanhada pela Companhia Ambiental do Estado de São Paulo (CETESB) por meio de uma rede de monitoramento das concentrações de CO, SO2, NOx, O3 e material particulado, com o objetivo primordial de proteger a saúde humana. Falhas nesse acompanhamento podem reduzir a disponibilidade da rede e comprometer as estratégias da CETESB associadas à preservação da qualidade ambiental, entre elas a qualificação de municípios quanto ao grau de saturação da qualidade do ar. Este trabalho realiza um estudo analítico sobre a disponibilidade rede automática de monitoramento e seus reflexos no licenciamento ambiental realizado pela CETESB, bem como discute a possibilidade de melhoria da informação prestada à sociedade baseada no aumento dessa disponibilidade. Encontrou-se entre 1998 a 2008 valores de disponibilidade média próximos a 80%, sendo que esse nível possivelmente influiu na qualificação de alguns municípios, classificados como saturado quando o plausível seria em vias de saturação, ou classificados como em vias de saturação ao invés de não saturado. Os reflexos dessa qualificação poderão ser observados no licenciamento ambiental de fontes de poluentes atmosféricos pela necessidade da compensação das emissões em municípios qualificados como saturado ou em vias de saturação. A disponibilidade média encontrada decorre predominantemente de falhas dos monitores de SO2, NOx e MP10 e de falhas de infraestrutura da rede automática, razão pela qual aperfeiçoar o programa de manutenção dos monitores e implantar um programa para os equipamentos de infraestrutura são algumas das recomendações que objetivam aumentar a disponibilidade para cerca de 88% e minimizar sua interferência na qualificação dos municípios quanto ao grau de saturação da qualidade do ar.
58

Estudos de tratabilidade da água do Rio Paraíba do Sul no trecho que abastece o Município de São José dos Campos-SP

Talita Natália Ferrari 28 February 2012 (has links)
Neste trabalho foram realizados estudos de tratabilidade das águas do Rio Paraíba do Sul no trecho que abastece o Município de São José dos Campos - SP, com o objetivo de analisar seu comportamento com o uso de dois coagulantes a base de alumínio, o sulfato de alumínio e o cloreto de polialumínio (PAC), e dois a base de ferro, o cloreto férrico e o reagente de Fenton. Inicialmente foram variadas as dosagens de coagulante versus pH de coagulação para a elaboração de diagramas de coagulação para a remoção de turbidez e cor aparente. Em seguida, foram selecionadas dosagens de coagulante com bons desempenhos de remoção de turbidez e cor aparente, adicionado hipoclorito de sódio como agente pré-oxidante (exceto para o reagente de Fenton) e testadas diferentes dosagens do polímero catiônico como auxiliar de floculação. Por fim, foram realizados ensaios do tratamento da água em ciclo completo. O cloreto férrico, nos ensaios realizados para a elaboração dos diagramas de coagulação, mostrou-se mais eficiente na remoção de turbidez e cor aparente se comparado ao demais coagulantes, nas condições em que o estudo foi realizado. Após o tratamento em ciclo completo o reagente de Fenton proporcionou, em geral, os menores valores de turbidez nas águas decantada e filtrada e as menores concentrações de trihalometanos (THM) medidas, porém os resultados de ferro total no efluente final não atenderam o padrão de potabilidade brasileiro (< 0,3 mg/L). Sendo assim, diante de todos os resultados apresentados no decorrer do trabalho, o sulfato de alumínio mostrou-se o coagulante mais indicado para o tratamento (em ciclo completo) da água do Rio Paraíba do Sul, nas condições em que os ensaios foram realizados.
59

Simulação do decaimento do cloro residual em sistema de abastecimento de água no Município de Campo Grande/MS

Jorge Maurício Sanabria 22 October 2012 (has links)
Este estudo tem como objetivo a análise do decaimento do cloro desinfetante na rede de distribuição de água potável do município de Campo Grande/MS. Para tanto, dividiu-se o trabalho em duas etapas. A primeira abrangeu a amostragem de três águas provenientes de diferentes origens (poço subterrâneo e duas estações de tratamento de água) e posterior teste de decaimento do cloro em laboratório. Os resultados dos testes foram ajustados a quatro diferentes modelos de decaimento do cloro na água encontrados na literatura especializada (1 ordem, 2 ordem, na ordem e 1 ordem limitada) a fim de se encontrar aquele que melhor os descrevessem. A segunda etapa abrangeu a escolha de subsistema de distribuição de água potável e sua simulação hidráulica e de qualidade de água no software EPANET. Como principais resultados obteve-se uma sensível diferença de demanda de cloro entre as águas amostradas; contudo, o modelo de enésima ordem apresentou melhores resultados entre os modelos testados quando ajustado aos dados (R2 = 0,96). Para a simulação hidráulica observou-se um bom resultado para parâmetros vazão e pressão (r = 0,899 e 0,57, respectivamente); ao passo que a simulação de qualidade de água, para o parâmetro residual de cloro, forneceu resultados mais distantes da realidade. Porém, pôde-se observar que o sistema simulado possui intervalos de operação onde o residual mínimo de cloro desinfetante exigido é colocado em risco, levando-se a sugerir aumento da dosagem de desinfetante para garantir a segurança do residual nas pontas de rede de distribuição estudada.
60

Indicadores de impactos climáticos para o abastecimento de água na bacia hidrográfica do ribeirão Guaratinguetá

Marília Costa Miranda 16 December 2013 (has links)
A variação temporal natural das vazões dos rios pode ser causa de dificuldades para o abastecimento urbano de água, tornando-se ainda mais complexo no cenário de possíveis mudanças climáticas presente nos dias atuais. O presente trabalho objetivou detectar tendências em séries temporais de dados hidrológicos de precipitação na bacia hidrográfica do ribeirão Guaratinguetá, Município de Guaratinguetá - SP, visando estabelecer um comparativo entre os valores históricos observados e os projetados através do modelo Eta/CPTEC para cenários futuros até o ano de 2.099. Foram analisados dados de precipitação e temperatura de estações hidrometeorológicas na bacia hidrográfica do Ribeirão Guaratinguetá, e gerados dados de evaporação, com o método de Thornthwaite, e de vazão do rio, com o modelo SMAP (Soil Moisture Accounting Procedure), e então submetidos ao teste estatístico não paramétrico de Mann-Kendall, visando a identificação de tendências. Ambas as séries históricas e projetadas apresentaram variação intra-anual dos volumes precipitados. Foi identificada tendência de aumento nos volumes de precipitação para a primavera. Em função desta elevação, foi possível notar um aumento das vazões simuladas para o futuro, no ribeirão Guaratinguetá, o que deve resultar em mudanças na operação do sistema de abastecimento de água. Por outro lado, a previsão de aumento dos volumes de vazão pode significar um benefício em relação ao déficit na demanda de água, ainda que seja necessária a realização de obras para adequação do sistema em função dos maiores volumes. Para uma maior exatidão nos valores simulados para a vazão do ribeirão Guaratinguetá, recomenda-se que o modelo SMAP seja calibrado e validado para vazões observadas, no momento não disponíveis para a área em questão.

Page generated in 0.1022 seconds