• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 151
  • 60
  • Tagged with
  • 211
  • 211
  • 207
  • 207
  • 207
  • 207
  • 207
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterização dosimétrica de gel tipo VIPARnd através de técnicas ópticas para feixes de raios x de 6mv usados em radioterapia externa

Dias, Juliana Rosada 23 June 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2015. / Submitted by Guimaraes Jacqueline (jacqueline.guimaraes@bce.unb.br) on 2015-11-20T09:38:06Z No. of bitstreams: 1 2015_JulianaRosadaDias.pdf: 31393679 bytes, checksum: c8721c906510421d6c5a443a36752c94 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2015-12-21T11:38:43Z (GMT) No. of bitstreams: 1 2015_JulianaRosadaDias.pdf: 31393679 bytes, checksum: c8721c906510421d6c5a443a36752c94 (MD5) / Made available in DSpace on 2015-12-21T11:38:43Z (GMT). No. of bitstreams: 1 2015_JulianaRosadaDias.pdf: 31393679 bytes, checksum: c8721c906510421d6c5a443a36752c94 (MD5) / Neste trabalho as principais características ópticas do dosímetro gel VIPARnd foram avaliadas para feixes de fótons de 6 MV usados em radioterapia externa. O espectro de absorvância do dosímetro gel foi avaliado com espectrofotometria óptica e através do processamento de imagens fotográficas adquiridas com câmera de sensor CMOS para doses de 0 a 50 Gy. Foram avaliadas duas soluções com concentrações diferentes dos componentes do gel. Os dados obtidos através da espectrofotometria óptica mostram que o VIPARnd apresenta pico de absorção entre 300 a 320 nm dependendo da dose absorvida. O aumento da dose absorvida causa aumento na absorvância do VIPARnd. As curvas de dose resposta foram analisadas em função do máximo de absorção e também através da área sob o espectro. A solução 1 apresenta região linear de 3 a 20 Gy e a solução 2 para a região de 0,5 a 5 Gy. A repetitividade entre amostras de um mesmo lote ficou em 0,5% e a reprodutibilidade inter-lotes em 5 %. A estabilidade do gel VIPARnd foi mantida para um tempo pós-irradiação de pelo menos 15 dias. As imagens fotográficas foram adquiridas em escala RGB, a partir da análise de absorção óptica foi suposto que a componente azul apresentasse maior resposta para determinação da dose absorvida o que de fato foi comprovado com os dados obtidos. Para este caso a faixa de resposta linear obtida foi entre 3 e 20 Gy para a solução 1 e entre 0,5 e 20 Gy para a solução 2. Como testes adicionais, foi analisado a curva de dose resposta a partir de imagens de tomografia computadorizada, assim como o estudado da aplicação do gel para medidas de perfil de campos pequenos e PDP para feixes de raios X de 6 MV e a resposta do gel à irradiações com fonte de irídio 192 usadas em braquiterapia de alta taxa de dose. O bom desempenho do dosímetro VIPARnd nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. ____________________________________________________________________________________ ABSTRACT / This work aims to evaluate the optical characteristics of a dosimeter VIPARnd for 6 MV photon beam used in radiotherapy. The absorbance spectrum of irradiated gel dosimeter was evaluated with optical spectrophotometer techniques and with CMOS camera readout for dose range of 0 to 50 Gy. Two solutions with different concentration were evaluated. Data shows that the VIPARnd has a maximum absorbance at 300 to 320 nm depending on the absorbed dose. The absorbed dose increases the absorbance values of VIPARnd. The dose response curves were obtained by the peak value and the relative area under of absorbance curve. The solution 1 shown interval of linearity from 3 to 20 Gy and the solution 2 from 0,5 to 5 Gy. The repeatability and inter-batch reproducibility of gel response were 0,5 % and 5% respectively. Temporal analysis indicates that the gel dosimeter has no significant variation in absorbance peak for the post irradiation times until 15 days. The CMOS camera readouts were obtained in RGB color, the absorbance measurements suggest a major response of dose for blue matrix verified with data. The dose response curve for blue component showed interval of linearity from 3 to 20 Gy for solution 1 and from 0,5 to 20 Gy. Additional tests were performed to determine the dose response with X-ray computed tomography, analyses of dose profile measurements for small field radiation therapy and percentage depth dose for 6 MV photon beam and gel response for irradiation with Iridium 192 source in high dose rate brachytherapy. These characteristics indicate that the presented VIPARnd polymer gel could be helpful for radiotherapy dosimetry.
2

VitalSleep: Wearable sleep device for ambulatory sleep quality monitoring

Márcia Raquel Estima Saraiva 26 November 2018 (has links)
No description available.
3

Funcionalidades avançadas para aplicações móveis de uma plataforma de monitorização contínua de saúde

Bruno Miguel Sousa Garcês 20 September 2013 (has links)
No description available.
4

Design e produção de bólus individualizados via impressão tridimensional para radioterapia externa

Susana Margarida Oliveira Goncalves 15 November 2017 (has links)
No description available.
5

Measurement System for Evaluation of Cycling Performance

Diogo José Fernandes Gonçalves 14 November 2017 (has links)
No description available.
6

Biomechanical Simulation of Erythrocites and Ovalocytes Cells

Sara Daniela da Silva Ferreira 06 September 2018 (has links)
No description available.
7

Automatic Classification of Ulcers Through Visual Image

Rita Maria Almeida Frade 12 July 2017 (has links)
No description available.
8

Remodelação Óssea Após a Inserção de Implantes no Osso do Fémur

Ana Teresa de Azevedo Castro 09 August 2018 (has links)
No description available.
9

New numerical methodology to simulate tumour cell proliferation

Catarina Isabel Ribeiro Assunção Maia dos Santos 13 July 2017 (has links)
No description available.
10

Avaliação de Próteses Transfemorais

Catarina Vitória Pires Domingues 14 November 2016 (has links)
No description available.

Page generated in 0.0867 seconds