• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 532
  • 89
  • 83
  • 83
  • 83
  • 83
  • 83
  • 83
  • 12
  • 2
  • 1
  • 1
  • Tagged with
  • 731
  • 731
  • 129
  • 123
  • 104
  • 59
  • 43
  • 39
  • 36
  • 35
  • 33
  • 33
  • 29
  • 28
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
591

Environmental health policy implementation in Hong Kong : a study of cleansing services in the Urban Services Department /

Woodhead Loo, Wing-ping, Marina. January 1986 (has links)
Thesis (M. Soc. Sc.)--University of Hong Kong, 1986.
592

Environmental health policy implementation in Hong Kong a study of cleansing services in the Urban Services Department /

Woodhead Loo, Wing-ping, Marina. January 1986 (has links)
Thesis (M.Soc.Sc.)--University of Hong Kong, 1986. / Also available in print.
593

Determining pen surface water in a cattle feedlot with thermal infrared remote sensing

Leiker, Curtis Joseph January 1900 (has links)
Master of Science / Department of Biological & Agricultural Engineering / Ronaldo G. Maghirang / Particulate matter (PM) emissions from open beef cattle feedlots depend heavily on the level of water on the pen surface. Wet pen surfaces are able to keep PM emissions low, while dry surfaces have much higher rates of emission. Current research shows that 20-25% surface water content is a critical threshold for minimizing PM emissions from open cattle feedlots. The amount of water on the pen surface will also dictate the level of gaseous emissions, such as ammonia, nitrous oxide, and hydrogen sulfide. Traditional methods of measuring pen surface water are not sufficient within a dense cattle feedlot and cannot provide a continuous method of measurement unattended. The process of using infrared thermometry and meteorological variables to remotely sense surface water provides an inexpensive, ground level approach. Testing in laboratory, outdoor, and feedlot conditions was conducted to analyze the potential of using the thermal inertia remote sensing approach. This approach involved continuous measurement of weighted soil water content, surface temperature of the soil, air temperature, solar radiation, wind speed, and relative humidity. Controlled laboratory testing performed the best at predicting soil water content from the difference in soil surface and air temperature, with the coefficient of determination (R2) at 0.91 for a Smolan silt loam and 0.83 for dry feedlot soil. Outdoor testing achieved mixed results with R2 values only as high as 0.38 for 10-cm soil layer and 0.67 for 5-cm soil layer. Testing in a cattle feedlot with dry, loose manure layer proved to be imprecise, but was able to differentiate surface water levels varying from 4.1% to 9.1% wet basis.
594

Evaluation of vegetated filter strips for attenuation of pollutants resulting from military activities

Satchithanantham, Sanjayan January 1900 (has links)
Master of Science / Department of Biological & Agricultural Engineering / Stacy L. Hutchinson / A field study was conducted at Fort Riley, Kansas from late spring to early winter of 2007 to investigate the ability of vegetated filter strips (VFS) to attenuate pollutants resulting from military activities, the impact of different management practices (i.e. burning and mowing) on VFS performance, and the effects of vegetation on hydrological components of VFS, especially infiltration and runoff. Two native tallgrass VFS sites, each comprising three plots, located in the military training area of Fort Riley were used for this study. Fifteen rainfall events were simulated on each site along with overland application of water containing nitrogen (N), phosphorous (P) and sediment. At the end of the season both VFS were managed by mowing or burning and a final rainfall simulation was done. Variables including rainfall, infiltration, runon, runoff, above ground biomass density, pollutant concentrations of runon and runoff, and soil moisture were measured and used in the data analysis. Hydrograph development, water balance, and mass balance calculations were carried out in order to calculate the pollutant trapping efficiencies (PTE) of the VFS. Statistical analysis was done by fitting several regression models. Mean comparisons were also done for variables and variance was decomposed into time, plot and site effects at an alpha = 0.05. Results showed that on average the VFS attenuated 84 % of total nitrogen, 24 % of total phosphorous and 95 % of sediments. Regression models showed that infiltration percentage and biomass density have a positive correlation with PTE. Runoff volume and PTE were negatively correlated. Soil moisture was negatively correlated with infiltration and time to runoff. With increasing biomass density, percentage of water infiltrating and time of concentration increased. Management practices, especially burning, tended to reduce PTE. Also, both management practices reduced infiltration percentage and time of concentration. PTE reduced with intensifying rainfall and increased when rainfall faded off. Phosphorous was the most sensitive pollutant for intense storm conditions followed by nitrogen, while sediment was comparatively insensitive.
595

Climate responsive vernacular architecture: Jharkhand, India

Gautam, Avinash January 1900 (has links)
Master of Science / Department of Architecture / R. Todd Gabbard / This research aims to explore and assess passive solar design techniques that promote high thermal comfort in vernacular houses of the state of Jharkhand in India. The study of these houses provides useful insights for designing energy efficient houses that provide thermally comfortable conditions. An analysis of these houses in Ranchi, the capital city of Jharkhand, India provides a context for the field research. Jharkhand predominantly has two different styles of vernacular houses: huts and havelis. These houses were constructed, without any mechanical means, in such a manner as to create micro-climates inside them to provide high thermal comfort levels. Hence the study of thermal comfort levels in these buildings in relation to built environment in today's context is significant. As part of data collection, interviews were conducted with the occupants of ten houses in Ranchi, in June 2007. Two houses of each (huts and havelis) were selected for detailed experimental analysis. Experiment results indicated that all the four selected houses exhibited lower ambient temperature than outside during the day and a higher ambient temperature at night. Brick bat coba and lime mortar were the key materials used for constructing high thermal-mass walls. Adequate ventilation is significant in creating conditions that are comfortable. Aperture to volume ratio of less than 0.051 is not adequate enough to cool the thermal mass of these houses. These houses also use attic space to mitigate the heat gain from the roof. Courtyards and other exterior spaces form an integral part of these houses and influence the thermal conditions in and around the houses. The case studies show that there is a scope for more relaxation of comfort temperature range based on culture and phenomenon of acclimatization. A universal approach in understanding and defining comfort condition fails because the users of these houses were comfortable in conditions defined as uncomfortable by ASHRAE and Nicol.
596

Greenhouse gas emissions and strategies for mitigation: opportunities in agriculture and energy sector

Parihar, Arun K. January 1900 (has links)
Master of Science / Department of Chemical Engineering / Larry E. Erickson / The impact of human activities on the atmosphere and the accompanying risks of long-term global climate change are by now familiar topics to many people. Although most of the increase in greenhouse gas (GHG) concentrations is due to carbon dioxide (CO2) emissions from fossil fuels, globally about one-third of the total human-induced warming effect due to GHGs comes from agriculture and land-use. This report provides a brief review of greenhouse effects and impacts on climate, human health and environment. The sources of emissions of greenhouse gases due to human activities, both current estimates and future projections, have been included. The report further discusses possible options for mitigation of greenhouse gases. The report also discusses the role agriculture can play towards mitigation of greenhouse gases as many agricultural processes such as anaerobic digestion, manure gasification; carbon sequestration etc. can help reduce or offset greenhouse gas emissions. Capture and sequestration of CO2 released as a result of burning fossil fuel in power plants, energy and other industries is gaining widespread interest as a potential method of controlling greenhouse gas emissions. Various technologies such as amine (MEA)-based CO2 absorption system for post-combustion flue gas applications have been developed, and can be integrated with existing plant operations. Removal of SO2 by using amine-based carbon capture system offers additional benefit. Efforts are underway to develop a broader suite of carbon capture and sequestration technologies for more comprehensive assessments in the context of multi-pollutant environmental management. Geologic formations and/ or possibly oceans can be used as sinks to store recovered CO2. In oil and gas exploration industry CO2 may be injected in producing or abandoned reservoirs which will not only help in maintaining the reservoir pressure (which improves overall field exploitation) but in some cases even leads to enhanced oil recovery.
597

Experimental investigation of optimal particulate sensor location in an aircraft cabin

Shehadi, Maher F. January 1900 (has links)
Master of Science / Department of Mechanical and Nuclear Engineering / Mohammad H. Hosni / Each year millions of people travel by commercial aircrafts. The Bureau of Transportation Statistics indicates that about 600 million passengers fly each year in the United States and, of those, roughly 350,000 are international travelers. This number of travelers leaves commercial airliners potentially vulnerable to biological contamination and makes the transmission of diseases a serious threat. The spread of SARS (Severe Acute Respiratory Syndrome) and H1N1 (swine flu) are examples of documented cases. Consequently, considerable research has been and continues to be conducted to study and understand particulate transport mechanisms and dispersion behavior inside aircraft cabins to develop means for detecting, controlling, and removing contaminants from aircraft cabins and to find methods for preventing the aircraft from being used for intentional contaminant deployment. In order to develop means to monitor and control air quality, infectious disease transmission, and particulate transport inside aircraft cabins, an experimental study was conducted to determine the best sensor placement locations for detection and to identify the number of sensors needed to accurately track air quality incidents within a cabin. An 11-row mockup, intended to be representative of a typical wide-body aircraft, was used for the research. The mockup interior is based on the actual dimensions of the Boeing 767 aircraft cabin. Inside the mockup cabin, actual aircraft equipment including seats and air diffusers were used. Each row has seven passenger seats. Particulates were released from different locations in the second row of the mockup cabin. The transported particles were then collected at six different locations in the lateral direction. The best location to place a sensor was defined as the location having the strongest signal (maximum number of particles collected) or the fastest detection time. After determining the best location in the lateral direction, particles were collected at the same location, but in different rows to estimate the differences between the signal strength and the delay time in detecting the signal from row to row. For the later investigation, the particulates were released in Row 2 and in Row 6 as well. For the six locations examined, it was found that the best location for the placement of a sensor in the 11-row mockup in the lateral direction is on the centerline near the cabin floor. Longitudinally, it was found that a sensor may be used for detecting particulates in the same row as the release and a row in front and in back of the release location. For the mockup cabin, a total of 4 sensors was recommended to monitor particulate releases in the 11 row mockup cabin, each of these sensors separated by two rows.
598

A decision analytic approach for evaluating water reuse in India.

January 2007 (has links)
acase@tulane.edu
599

Decolorization of textile wastewater using peat-enhanced activated sludge process.

January 2003 (has links)
acase@tulane.edu
600

Development of an oxidative-acid disinfection process using chlorine dioxide and nitrous acid to produce Class A biosolids.

January 2005 (has links)
acase@tulane.edu

Page generated in 0.206 seconds