• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 88
  • Tagged with
  • 89
  • 89
  • 43
  • 36
  • 31
  • 26
  • 23
  • 23
  • 21
  • 15
  • 13
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Diagnóstico e avaliação do saneamento básico da zona leste da cidade de Teresina - PI

Arcoverde Filho, Dirceu Mendes [UNESP] 10 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-10Bitstream added on 2014-06-13T19:36:07Z : No. of bitstreams: 1 arcoverdefilho_dm_me_rcla.pdf: 6204134 bytes, checksum: 02ac879ad43e1d76e4f0e87c4a264bd8 (MD5) / A forma pela qual os recursos hídricos são utilizados vem degradando os mananciais a um nível tal que se compromete a qualidade de vida das populações. Exauridos pela atividade antrópica, esse fato pode se tornar, no futuro, causador de conflitos. O setor de saneamento básico, sendo um dos que mais se utilizam dos recursos hídricos, é parte de fundamental importância no sentido de promover a melhoria da qualidade de vida da população, utilizando os recursos hídricos de maneira ambientalmente sustentável e garantindo os serviços de abastecimento de água e esgotamento sanitário, mesmo no cenário atual de crescente urbanização, quando se enfrenta a falta de recursos suficientes para expansão dos serviços e a ineficiência no uso dos recursos arrecadados no setor. No quadro dessa problemática, este estudo analisa o espaço urbano da zona leste de Teresina, focalizando o saneamento básico em seus bairros no que diz respeito à problemática dos serviços de abastecimento de água, esgoto sanitário e coleta de lixo. Verifica-se que as camadas mais pobres da população são as que mais sofrem as conseqüências da falta de infraestrutura desses serviços, com a ocorrência de doenças como hepatite e enteroinfecções, contribuindo para a redução da qualidade de vida da população e evidenciando ainda a segregação social existente entre os bairros de uma mesma região da cidade / The way in which water resources are used is degrading the water sources at a level that compromises the quality of life of populations. Depleted by human activity, this may become in the future, causing conflicts. The basic sanitation sector, being one of the most use of water resources, is part of fundamental importance to improving the quality of life of the population using water resources in an environmentally sustainable manner and ensuring the supply services water and sanitation, even in the current scenario of increasing urbanization, when faced with the lack of sufficient resources for expansion of services and inefficiency in the use of funds raised in the industry. As part of this problem, this study examines the urban spaces of the east side of Teresina, focusing on sanitation in their neighborhoods with respect to the issue of services of water supply, sewage and garbage collection. It appears that the poorest of the population are the ones that suffer the consequences of lack of infrastructure such services, with the occurrence of diseases like hepatitis and enteroinfecções, contributing to reduced quality of life of people and showing also the social segregation between the neighborhoods of the same region of the city
22

Adenovirus e rotavirus como indicadores biologicos em aguas residuarias de esgotos sanitarios apos tratamento por processo anaerobio e disposição controlada no solo / Adenoviruses as biological indicators in watewater from sewage, before anaerobic process treatment and soil disposal

Martins, Sandra Soares 09 August 2018 (has links)
Orientador: Maria Silvia Viccari Gatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-09T22:09:52Z (GMT). No. of bitstreams: 1 Martins_SandraSoares_M.pdf: 1140484 bytes, checksum: de8846c9246eef9258a4b0d3953a88b6 (MD5) Previous issue date: 2006 / Resumo: O tratamento de esgoto sanitário em lagoa de decantação anaeróbia e disposição controlada de água residuária no solo é uma alternativa de baixo custo para o reuso de águas residuárias na agricultura. Nele, o esgoto sanitário é depositado em uma lagoa de decantação anaeróbia com retenção hidráulica de sete dias, após o que a água residuária é conduzida para rampa de solo franco argilo-arenoso, com cobertura vegetal de gramínia Cynodon sp, para disposição por escoamento superficial, seguindo-se sua infiltração e percolação. O objetivo desse trabalho foi verificar a eficiência desse sistema na eliminação e/ou inativação de adenovírus humanos (HAdV) e rotavírus (RV). Amostras de 1L de água residuária foram obtidas em quatro coletas, em intervalos de sete dias, na entrada do esgoto bruto (EB), no ponto de aplicação na rampa (0m) e nos pontos da sua superfície após 10, 20, 30, 35m e 40m. Sob a rampa, a 1m de profundidade e distantes 30m (30-1) e 35m (35 -1), dois pontos foram amostrados. Antes do ponto 0m, pontos de testemunha a 1m de profundidade e distantes 2m (T1) e 0,5m (T2) da rampa, e um ponto do lençol freático (LF) a 3m de profundidade, também foram coletados.As água residuárias foram concentradas de 1.000 a 5.000 vezes por filtração e eluição em membrana eletropositiva e ultracentrifugação. Nos eluatos obtidos, após extração de DNA, a presença de HAdV foi pesquisada por PCR e nested-PCR. Para a detecção de RV usou-se RT-PCR e duplo-semi- nested-PCR. Eluatos HAdV positivos foram inoculados em células HEp-2 e após até cinco passagens a presença de HAdV foi confirmada por PCR.. HAdV foram detectados em 29 das 35 amostras analisadas, sendo positivos todos os pontos de EB e da superfície da rampa. Em profundidade, sob a rampa, quatro amostras foram positivas, além de outras duas em T2 e uma em LF, o que demonstra a percolação desses vírus no solo com contaminação do LF. Quando testadas em células HEp-2, nas amostras do EB e dos pontos 0, 30, 35 e 40m a presença de vírions foi determinada, enquanto nos pontos 30-1m e LF os HAdV não foram infectivos. Esses resultados permitem concluir que o sistema não foi eficiente para remover e/ou inativar HAdV. Por outro lado, pode-se afirmar que os HAdV são indicadores virais adequados para esse sistema, desde que mantida a metodologia aqui empregada. Uma amostra de EB foi positiva para RV (genotipos G1 e G2), resultado esse que não permite qualquer conclusão. Para o reuso da água residuária advinda desse sistema impõe-se a associação de processos de desinfecção para a eliminação de HAdV / Abstract: Urban sewage treatment by an anaerobic process with overland flow system is a cheap alternative to reuse domestic effluents in agriculture. In this procedure, wastewater remains in an anaerobic pond for seven days, and then it is spilled from the top of a 40-meter extension slope covered with Tifton 85 (Cynodon sp) grass in order to surface flow and percolate until it reaches groundwater. The objective of this work is to determine if this procedure could be effective in removing and/or inactivating human adenoviruses (HAdV) and rotaviruses (RV) in a test unit in Limeira - SP, Brazil. Samples were collected every seven days from different spots in four sampling events totalizing one liter of wastewater. Sampling points were chosen at the raw sewage (EB), on the surface of the slope at 0, 10, 20, 30, 35 and 40 meters, and down one meter from the surface of the slope at the 30- and 35-meter points (30-1 and 35-1). Other points upslope were used at a distance of 2 meters (T1) and 0.5 meters (T2), beyond a 3-meter depth and 1-meter distant spot (LF). All samples were concentrated from a 1000 to 5000 times by filtration through electropositive microporous membrane followed by ultracentrifugation. HAdV detection was performed by both PCR and nested PCR. RV detection was accomplished by both RT-PCR and duplex semi-nested PCR. The positive samples for HAdV were inoculated in HEp-2 cells, and confirmation of the virions was performed by PCR. HAdV were detected in 29 of the 35 samples tested including in all samples both from the EB and from the surface of the slope. HAdV tested positive in the two T2, in one LF, and in the four samples underneath the slope. In HEp-2 cells HAdV virions were detected at the EB and at 0, 30, 35, and 40 meters on the surface of the slope. Spots 30-1 and LF were tested in HEp-2 cells, resulting negative to the presence of infective viral particles, although they tested HAdV positive. These results attest to the inefficiency of the proposed system of sewage treatment in removing and/or inactivating HAdV; however, maintaining the methodology used in this research, HAdV proves to be the appropriate viral indicator in this system. In relation to RV, no conclusions can be extracted since just one sample from the EB was RV-positive (G1 and G2 mixture). Finally, before reuse in agriculture, the effluents from the anaerobic pond should be disinfected to eliminate these viruses / Mestrado / Microbiologia / Mestre em Genética e Biologia Molecular
23

Emissão de metano nas lagoas de decantação da Estação de tratamento de esgotos de Jundiaí / Methane emission from decantation lagoons in Jundiaí wastewater treatment plant

Santos, Antonio Carlos dos 16 August 2018 (has links)
Orientadores: Edson Aparecido Abdul Nour, Pedro Sérgio Fadini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-16T21:36:15Z (GMT). No. of bitstreams: 1 Santos_AntonioCarlosdos_M.pdf: 4339309 bytes, checksum: 8c2a2b650382806186dfd588a5c69deb (MD5) Previous issue date: 2010 / Resumo: No presente trabalho foi verificada a contribuição nas emissões de metano para a atmosfera da Estação de Tratamento de Esgoto de Jundiaí, em duas campanhas de coletas em suas lagoas de decantação, com as amostragens sendo realizadas em pontos próximos à entrada e à saída das lagoas. Utilizou-se um coletor de gás semelhante ao concentrador de gás interno do reator UASB, a técnica da câmara estática para amostragem dos fluxos totais e a câmara estática adaptada para a coleta dos fluxos difusivos, na qual foi instalado um anteparo para impedir a coleta dos fluxos ebulitivos. Para a análise dos fluxos foram medidas as variáveis ambientais, pressão e temperatura. Os fluxos foram medidos e divididos por tipo: difusivos (liberados para a atmosfera por meio da difusão mássica) e ebulitivos (liberados para a atmosfera por meio de bolhas). O fluxo ebulitivo representou cerca de 95% da liberação total de metano para a atmosfera, e um valor médio de 9.008 mg CH4/m2 d. O fluxo difusivo teve valor médio de 421 mg CH4/m2 d. Devido a pouca variação nas temperaturas não foi possível verificar a sua correlação com os fluxos de metano. Porém com a altura do manto de lodo no interior das lagoas a correlação foi direta. Na estimativa do potencial energético do metano, os 471 kg CH4/d que poderiam ser recuperados, gerariam até 196 MWh/mês de energia elétrica, desconsiderando-se as perdas do sistema. Considerando-se o fluxo total médio e a área total das quatro lagoas de decantação, a emissão anual de metano foi de 264 Mg CH4. Estas estimativas ainda conservam uma incerteza devido às extrapolações das medidas realizadas / Abstract: In the present work was estimated the contribution of methane emission to the global atmosphere. In this study were realized two campaigns of collections in the settling ponds n.°03 (2008) and n.°04 (2010) with sampling operation being carried out in points coming into and out of the lagoons. A gas collector has been utilized as the UASB inner gas keeper and the static chamber technique to samples of the total flux, that chamber was adapted to collect diffusive flux in which was settled a screen to prevent bubble flux. To the flux analyses were measured some environmental variable mainly the temperature, and divided by type: diffusive (released to the atmosphere through the massive diffusion) and bubble (released to the atmosphere through bubble). The bubble flux submitted about 95% of the total methane liberation to the atmosphere and submitted an average value of 9.008 mgCH4/m².day. The diffusive flux submitted an average value of 421 mgCH4/m².day. Due of a little variation in the temperature it was not possible to verify the co-relation between methane flux with the temperatures. In spite of the height backlog of sludge in the deep of collection the direct co-relation was obtained. In the energetic potential of methane was estimated 471 kgCH4/day that could be recovered, would generate until 196 MWh/month of energy ignoring the system loss. Considering the average total flux of total area of the collection decantation lagoons, the annual emission of methane was 264 MgCH4 (Mega grams of methane). Those estimates still retain an uncertainty due extrapolations of the measures carried out / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
24

Tratamento de efluente sanitário, utilizando filtro anaeróbio como reator de desnitrificação para reúso agrícola / Treatment of sanitary wastewater, using anaerobic filter as desnitrification reactor for agricultural reuse

Senna, Paula Regina Coeli Barbosa 17 August 2018 (has links)
Orientador: Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-17T01:24:25Z (GMT). No. of bitstreams: 1 Senna_PaulaReginaCoeliBarbosa_M.pdf: 5617120 bytes, checksum: 340fdd25e903f12f594069b1c57b10b9 (MD5) Previous issue date: 2010 / Resumo: O excesso de nutrientes, provenientes principalmente de esgotos sanitários, que são lançados em corpos receptores pode levar ao processo de eutrofização, ocasionando efeitos adversos ao meio ambiente. Surge então a necessidade do tratamento avançado ser considerado no planejamento dos recursos hídricos. Deste modo, avaliou-se a desnitrificação de uma parcela do efluente sanitário proveniente UNICAMP. Para isso, esta água residuária foi tratada por um filtro anaeróbio com recheio de bambu (Bambusa tuldoides), operado com tempo de detenção hidráulica de 9 horas, sendo logo após direcionada para um filtro de areia (aeróbio). Tendo como alternativa o reuso agrícola, o processo de desnitrificação do efluente é fundamental evitando-se a percolação do nitrato no solo. Na primeira fase do estudo, o efluente dos filtros de areia foi aplicado em reator anaeróbio com recheio de brita, variando-se as vazões de fonte de carbono de 20 para 25L e o tempo de detenção hidráulica de 4 para 7 horas. Na segunda fase, o efluente nitrificado no filtro de areia foi recirculado para o filtro anaeróbio com recheio de bambu, em proporções de 15% e 20% em relação ao esgoto bruto. As duas fases do tratamento atingiram até 60% de desnitrificação, com efluente dentro de padrões de lançamento para DQO, DBO para fase 1 como também eficiência na desinfecção referente a Coliformes Totais e Escherichia Coli de acordo com Legislação, podendo o efluente ser lançado em corpos hídricos de classe 2, como também aplicado em práticas de reúso de classe A, B e C / Abstract: The excess nutrients, mainly from sewage released into receptors, can lead to eutrophication, causing adverse effects to the environment and also the health of the population. Then comes the need for advanced treatment be considered in the planning of water resources. Thus, we estimated the denitrification of the University of Campinas Hospital's sanitary effluent, through a combination of aerobic and anaerobic filter. To do so, the wastewater was treated by an anaerobic filter filled with bamboo (Bambusa tuldoides), operated with hydraulic retention time of 9 hours, forwarded by a sand filter. Intermittent operation was used to ensure a wide ground layer oxygenation, causing nitrification of 80% of the affluent. Denitrification is an essential process when reusing wastewater for agricultural purposes, as it prevents the percolation of nitrate in the soil. The denitrification analysis was done in two phases. First, the sand filter's effluent hás been applied into the anaerobic reactor filled with gravel with flows of carbon source of 20 and 25L and hydraulic retention time from 4 to 7 hours. The obtained values were within the standards for reuse. Second, the nitrified effluent in sand filter is recirculated to the anaerobic filter filled with bamboo, in proportions of 15% and 20% compared to raw sewage. Both phases of the treatment achieved a rate of 60% effluent denitrification and, for first phase, the effluents are in agreement with the standards releases of COD, BOD as well as the disinfection efficiency regarding coliform and Escherichia Coli. According to law, the effluent may be flowed out into bodies of water Class 2 and also can be applied in reuse practices of class A, B and C / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
25

Filtro anaeróbio seguido de biofiltro aerado submerso = produção de biomassa, conversão de matéria orgânica e de nitrogênio / Anaerobic filter followed submerged aerated biofilter : biomass production, conversion of organic matter and nitrogen

Foco, Mário Luiz Rodrigues, 1981- 12 February 2010 (has links)
Orientador: Edson Aparecido Abdul Nour / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-17T07:54:12Z (GMT). No. of bitstreams: 1 Foco_MarioLuizRodrigues_M.pdf: 3471759 bytes, checksum: 1643f91209e0cdb8cb1ba9502091e4a1 (MD5) Previous issue date: 2010 / Resumo: Sistemas de tratamento concebidos a promover a diminuição das concentrações: de amônia por meio da nitrificação e de Nitrogênio Total (NT) utilizando desnitrificação, são necessidades cada vez maiores para diminuir os impactos causados nos ecossistemas aquáticos quando do aporte de espécies nitrogenadas. Estudou-se o desempenho de um sistema combinado anaeróbio/aeróbio, tratando esgoto sanitário, do complexo hospitalar, da Unicamp, constituído por filtro anaeróbio (FA) seguido de biofiltro aerado submerso (BAS), empregados para a conversão de matéria orgânica e nitrogênio amoniacal, sem a recirculação de biomassa das unidades. A desnitrificação foi avaliada pelo encaminhamento do efluente formado no BAS para o FA, onde em ambiente redutor os doadores de elétrons utilizados foram os compostos orgânicos de rápida biodegradação presentes no esgoto bruto e os ácidos orgânicos formados no processo anaeróbio. O estudo foi dividido em 3 etapas experimentais: 1ª etapa, avaliou-se a conversão de matéria orgânica em dois regimes hidráulicos (TDH total de 23,2 e 20,9 h); 2ª etapa, buscou-se estabelecer o processo e a biomassa relacionada a nitrificação, em dois regimes hidráulicos (TDH total de 18,6 e 13,9 h); 3° etapa, avaliou-se a possibilidade de desnitrificação em dois regimes hidráulicos diferenciados pela ausência e presença de recirculação do efluente tratado pelo BAS, a razão de 0,5 (ambos com TDH total de 18,6 h) A melhor condição operacional (12,1 h no FA e 6,5 h no BAS), apresentou redução das concentrações de DQO, DBO e SST, respectivamente, de 93 ± 3 %, 99 ± 1 % e 98 ± 2 %, com concentrações médias efluentes de 48 ± 9 mg DQO L-1, 5 ± 1 mg DBO L-1 e 3 ± 2 mg SST L-1 (2° etapa), não havendo diferenças significativas (p>0,05) com o desempenho da 3° etapa. Nesta sem recirculação, com TCN de 0,22 ± 0,02 kg N-NH3 m-3 d-1 e TCO de 0,91± 0,31 kg DQO m-3 d-1, alcançou-se nitrificação no BAS de 0,10 ± 0,05 kg N-NO3- m-3 d-1, relação C/N de 4 ± 1,5 e conversão de NH3 de 54 ± 20 %; na 3° etapa com recirculação, com TCN de 0,34 ± 0,05 kg N-NH3 m-3 d-1 e TCO de 0,81 ± 0,16 kg DQO m-3 d-1, alcançou-se nitrificação no BAS de 0,17 ± 0,02 kg N-NO3- m-3 d-1, C/N de 3,4 ± 0,6, conversão de NH3 de 61 ± 20 % e de NT de 43 ± 10 %. No FA em virtude da recirculação de efluente a uma razão de 0,5 a taxa de carregamento de nitrato aplicada foi de 0,024 ± 0,011 kg N-NO3- m-3 d-1 com 89 ± 3 % de conversão. A recirculação do efluente não interferiu na conversão de matéria orgânica, indicando que a configuração e operação proposta está adequada a atender as expectativas sobre sua robustez e possibilidade de reduzir a concentração de carbono orgânico e compostos de nitrogênio, influenciou positivamente em relação a regulação da relação C/N no BAS, porém a recirculação foi insuficiente para promover a regulação da relação C/N-NOx no FA e possibilitar o aumento da conversão de nitrato / Abstract: Treatment systems designed to reduced concentrations ammonia through nitrification and Total Nitrogen (TN) using denitrification, are growing needs to reduce to the impacts on aquatic ecosystems by discharge of nutrients. Evaluated the performance combined anaerobic/aerobic system to treat sewage of the hospital complex, Unicamp, consisting of anaerobic filter (AF) followed by aerated submerged biofilter (ASB) used for the conversion of organic matter and ammonia nitrogen without recirculation of biomass between reactors. Denitrification was evaluated by recirculating part of the effluent formed in the ASB for the AF, in environment reducing where the electron donors used were those organic compounds of rapid biodegradation present in raw sewage and organic acids formed in the anaerobic process. The study was divided into three experimental steps. Step 1, evaluated the conversion of organic matter in two hydraulic regimes (total HRT of 23.2 and 20.9h), step 2, tried to establish the process and biomass related to nitrification in two HRT (18.6 and 13.9h), step 3, evaluated the possibility of denitrification in two HRT distinguished by the absence and presence of recirculation of treated effluent by ASB, ratio of 0.5 (both with HRT of 18.6h) The best operating condition (12.1h in AF and 6.5h in ASB) showed conversion efficiencies of COD, BOD and TSS, respectively, 93 ± 3% 99 ± 1% and 98 ± 2%, with average effluent concentrations of 48 ± 9 mg COD L-1, 5 ± 1 mg L-1 BOD and TSS 3 ± 2 mg L-1 (2nd stage), no differences significant (p>0.05) with the performance of the 3rd step. In this without recirculation, with NLR to 0.22 ± 0.02 kg NH3 m-3 d-1 and OLR 0.91 ± 0.31 kg COD m-3 d-1, was reached in nitrification ASB 0.10 ± 0.05 kg NO3- m-3 d-1, C/N of 1.5 ± 4, and NH3 conversion of 54 ± 20%, while on the 3rd stage with recirculation, with the NLR 0.34 ± 0.05 kg NH3 m-3 d-1 and OLR 0.81 ± 0.16 kg COD m-3 d-1, was reached in ASB nitrification of 0.17 ± 0.02 kg NO3- m-3 d-1, C/N of 3.4 ± 0.6, NH3 conversion of 61% ± 20 and NT 43 ± 10%. In the AF due to the effluent recycle ratio of 0.5 to nitrate loading rate applied was 0.024 ± 0.011 kg NO3- m-3 d-1 with 89 ± 3% conversion. The recirculation did not affect the conversion of organic matter and indicated that the proposed configuration and operation is adequate to meet the expectations of its robustness and ability to reduce the concentration of organic carbon and nitrogen compounds, positively influenced regarding the regulation of C/N ratio in ASB, but this was insufficient to promote the regulation of the C/N-NOx ratio in AF and to increase the conversion of nitrate / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
26

As parcerias público-privadas como ambiente de captação de investimentos em estações de tratamento de esgotos no Brasil. / Public-private partnerships as a means of funding wastewater treatment investiments in Brazil.

Leandro Morais e Silva 25 May 2006 (has links)
Este trabalho tem por objetivo estudar a utilização dos contratos de parceria públicoprivada, como um meio de captação de recursos da iniciativa privada para os investimentos em estações de tratamento de esgotos no Brasil. Para tanto, inicialmente, diagnosticou-se a situação atual dos serviços de tratamento de esgotos, as necessidades de recursos para a sua universalização, os investimentos realizados e o marco regulatório existente. Em seguida, para se discutir o ingresso de recursos privados, caracterizou-se o ambiente definido pela legislação brasileira para os contratos de parceria público-privada, bem como os vetores de riscos presentes neste ambiente de captação de recursos para as estações de tratamento de esgotos. Por fim, foi elaborado um protótipo para análise da qualidade destes investimentos, buscando orientar o investidor não aparente sobre a distorção nos indicadores da qualidade, provocados pelos vetores de riscos presentes nesta tipologia de empreendimento. / This research aims to study the use of public-private partnerships as a means of funding wastewater treatment investments in Brazil. For this purpose, the current situation of the wastewater treatment services, the need for resources for their universalization, the investments and the existing regulatory frameworks were initially diagnosed. After that, in order to discuss the influx of private investments, the Brazilian legislation for public-private partnership contracts was characterized, as well as the risks of this type of funding for wastewater treatment plants. Finally, a prototype for the analysis of the investment quality was designed to guide stakeholders about probable distortions in performance indicators caused by risk factors present in this type of project.
27

Estudo do escoamento em condutores horizontais de sistemas de coleta de esgotos sanitários de edifícios residenciais. / Study of the flow in horizontal conductors of waste water systems of residential buildings.

Lúcia Helena de Oliveira 22 May 1991 (has links)
Os condutores horizontais dos sistemas de coleta de esgotos sanitários, no Brasil e em quase todos os países do mundo, tem sido dimensionados considerando-se o escoamento em regime permanente, o que na realidade não ocorre. Sabendo-se que o escoamento no interior destes condutores acontece em regime não permanente, caracterizado pelo movimento de ondas, devido a aleatoriedade de uso dos aparelhos. Neste trabalho, apresentamos o estudo do escoamento não permanente, verificado, nos ramais e coletores dos sistemas de coleta de esgotos sanitários de edifícios residenciais. As equações diferenciais da continuidade e da quantidade de movimento, que regem este escoamento, são resolvidas pelo método das características. Apresentamos, também, os resultados e análise de várias simulações do programa de computador desenvolvido com base no método das características pelo professor Swaffield, da Universidade Heriot-Watt, Escócia. Os dados de entrada para estas simulações foram obtidos a partir de ensaios laboratoriais de algumas configurações de ambientes sanitários brasileiros, também apresentados neste trabalho. Os resultados destas simulações mostram que a consideração do escoamento em regime não permanente, possibilita a redução dos diâmetros dos ramais e coletores, e consequentemente, a redução dos custos destes sistemas. / Usually horizontal waste pipes of Building Drainage Systems, in Brazil and almost all of countries in the world, are dimensioned considering a steady flow, that does not exist. The random use of the sanitary appliances connected to the Drainage Systems of the building is the responsible for the unsteady flow. We present a study of unsteady partially filled pipeflow for drains and sewers. The differential equations of continuity and motion are solved via the method of characteristics. We present, also, the results and analysis of several simulations using a computational program developed by Prof. Swaffield-Heriot - Watt University, Scotland. The data entry were obtained through laboratorial tests which considered brazilian bathroom configurations, presented in this work. The results show us that the consideration of unsteady flow conduct to the reductions of horizontal waste pipes diameters, consequently to the reduction of the Building Drainage Systems costs.
28

Redução dos diâmetros de ramais e coletores nos sistemas prediais de esgotos sanitários. / Diameter reduction on drains and main drains of building dranaige system.

Bruno Tavares Baroni 04 June 2018 (has links)
O aumento da demanda por água potável em função do crescimento populacional, vem sendo objeto de estudo de diversos pesquisadores que buscam meios de otimizar o uso desse recurso. Desse modo, ao longo dos anos os equipamentos sanitários foram sendo aperfeiçoados para tornarem-se mais eficientes. Uma preocupação é o impacto nos ramais e coletores de sistemas prediais de esgotos sanitários, uma vez que os componentes economizadores ao demandarem menos água em sua operação, retornam vazões menores para a rede predial de esgoto sanitário e, consequentemente, geram ondas menores que impactam negativamente na autolimpeza dos condutos horizontais. Nesse sentido, o objetivo da pesquisa foi investigar, em laboratório, as vazões e profundidades da lâmina d´água do escoamento em ramais e coletores do sistema de esgotos sanitários de edifícios residenciais unifamiliares, tendo em vista a redução de diâmetros de 100 mm para 75 mm. A pesquisa foi realizada em laboratório vertical, onde foi montada uma configuração típica de um banheiro residencial, localizada no pavimento superior. Foram utilizadas bacias sanitárias com volume nominal de descarga de 6 L e 4,8 L, um chuveiro com vazão constante de 0,20 L/s e um lavatório com vazão constante de 0,15 L/s. As bacias sanitárias foram ensaiadas para calibração, segundo a NBR 15097 (ABNT, 2011) e ambas obtiveram resultados satisfatórios em todos os requisitos dessa norma. Foram variados os diâmetros dos ramais e coletores prediais de 100 mm para 75 mm, com e sem a contribuição da vazão em regime permanente de 0,35 L/s proveniente de um chuveiro e um lavatório e as declividades variadas em 0%, 1% e 2% nos ramais e 1%, 2% e 3% nos coletores de esgoto. Avaliou-se a influência dos parâmetros declividade, volume de descarga, presença ou não de vazão em regime permanente e diâmetro da tubulação, sobre a velocidade de escoamento da água. Concluiu-se que a redução dos diâmetros dos ramais e coletores de esgoto e a redução do volume de descarga de 6 L para 4,8 L contribuíram para o aumento da velocidade da onda sob as condições de estudo em todo o trecho ensaiado, ou seja, no trecho compreendido entre a bacia sanitária e o tubo de queda e ao longo de todo comprimento de 3 m do coletor de esgoto predial. Não foi estudada a influência da variação dos parâmetros sobre a velocidade de onda em trechos além do coletor de esgoto predial. Sob as condições de estudo, observou-se que a declividade não influencia, de maneira geral, no desempenho do sistema nos trechos ensaiados. A presença de uma vazão em regime permanente contribui para amortizar a energia da onda de descarga da bacia sanitária no ramal de descarga e consequentemente, reduz a velocidade de escoamento da água, o que pode contribuir para a piora do requisito de autolimpeza neste trecho da tubulação. No coletor de esgoto, não foi possível concluir que a presença de vazão em regime permanente tem impacto sobre a velocidade de escoamento da água. Por fim, conclui-se ser possível a redução dos diâmetros dos ramais e coletores do sistema predial de esgoto sanitário. / The increase in the demand for drinking water due to the population growth has been the object of study of several researchers who seek ways to optimize the use of this resource. In this way, over the years sanitary equipment has been improved to become more efficient. One concern is the impact on drains and main drains of building drainage system, since the economizing components, while using less water in their operation, return smaller flows to the sanitary sewage network and consequently lead to the formation of smaller waves that contribute to the self-cleaning of pipes. In this sense, the objective of the research was to investigate, in the laboratory, the flows and the depths of the flow in drains and main drains of residential building drainage system, in order to reduce diameters from 100 mm to 75 mm. The research was carried out in a vertical laboratory, where a typical configuration of a residential bathroom located on the second floor of a two story building was set up. A toilet with a nominal discharge volume of 6 L and 4,8L, a shower with a constant flow rate of 0.20 L/s and a lavatory with a constant flow rate of 0.15 L/s were used. The toilets were tested according to NBR15097 (ABNT, 2011) for calibration and both obtained satisfactory results in all the requirements of this standard. The diameters of the drains and main drains were varied from 100 mm to 75 mm with and without the contribution of the continuous flow rate of 0.35 L/s from a shower and lavatory and the slopes varying in 0%, 1% and 2% in the drains and 1%, 2% and 3% in the main drain. The influence of the parameters like slope, discharge volume, presence or not of continuous flow rate and pipe diameter, on the water flow velocity were evaluated. It was concluded that the reduction of the diameters of the drains and main drains and the reduction of the volume of discharge from 6 L to 4.8 L contribute to the increase of the velocity of the wave in the whole parts of the drain and main drain. It was not studied the influence of the variation of the parameters on the wave velocity on parts beyond the main drain. It was observed that the slope variation does not influence in general performance of the system. The presence of a continuous flow rate contributes to amortize the discharge wave energy from the toilet at the drains and consequently reduces the flow velocity of the water, which may contribute on deterioration of the self-cleaning requirements in this section of the pipeline. In the main drain, it was not possible to conclude that the presence of permanent flow has an impact on the flow velocity of the water.
29

Protótipo de biofiltro percolador com uso de meio suporte sintético / Prototype of biofilter percolator with synthetic support

Bergamini, Natália Cedran, 1984- 26 August 2018 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T02:02:33Z (GMT). No. of bitstreams: 1 Bergamini_NataliaCedran_M.pdf: 5745897 bytes, checksum: 69560c23a66d8d968b36f4b34e17bc8d (MD5) Previous issue date: 2014 / Resumo: Este trabalho consistiu em inovação tecnológica antes nunca testada desde a concepção, projeto, construção e operação de um biofiltro percolador de tratamento de esgoto sanitário em escala piloto. O reator foi desenvolvido nas instalações do Laboratório de Protótipos da Faculdade de Engenharia Civil da UNICAMP, cidade de Campinas, estado de São Paulo, é constituído de pré-filtro fabricado com a manta acrílica resinada, 3 reatores biológicos percoladores dispostos em séries, revestidos de não tecido sintético e filtro secundário confeccionado do mesmo material do pré-filtro. A vazão real média de alimentação do sistema era de 12,8 L h-1, tendo sido operado em regime hidráulico com tempo de detenção hidráulico variável de 82 a 100 minutos. A inovação baseou-se no uso de não tecido sintético com tripla função: a) proporcionar o fluxo do substrato sob ação da gravidade; b) promover a troca gasosa entre o meio líquido e a atmosfera; e c) constituir-se como meio suporte da biomassa, além de verificar as condições operacionais e tipos de mantas para viabilizar o tratamento de esgoto na remoção de matéria carbonácea sem a necessidade de aeração artificial. Neste estudo, foi analisada a remoção de sólidos suspensos (SS), turbidez, oxigênio dissolvido, DQO e DBO5. Os resultados médios de remoção de DQO e de DBO nas diferentes fases operacionais variaram de 75 a 86% e de 80 a 86%, respectivamente. As concentrações médias de DQO no efluente final variaram de 81 a 179 mg/L, enquanto as concentrações médias de DBO estiveram entre 47 a 97 mg/L. As médias globais de SST no efluente final foram mantidas em 49 mg/L. Com remoção de turbidez de 92,8%. O sistema PF/FBP (Pré-filtro/Filtro Biológico Percolador) pode se tornar uma alternativa muito promissora para o tratamento de esgoto sanitário de pequenas instalações do Brasil, uma vez que o sistema manifestou baixos tempo de detenção hidráulica e eficiência na remoção de DQO, DBO5 e sólidos suspensos, resultando em uma instalação compacta e de baixos custos. Além disso, o consumo de energia e os custos operacionais são mínimos / Abstract: This work consisted in technological innovation never before tested from conception, design, construction and operation of a trickling biofilter wastewater treatment in pilot scale. The reactor was developed on the premises of the Laboratory Prototypes of the Faculty of Civil Engineering, UNICAMP, Campinas, São Paulo, is constituted of prefilter manufactured with resin-coated acrylic blanket, three biological trickling reactors arranged in series, coated and synthetic nonwoven secondary filter made of the same material pre-filter. The average real power flow of the system was 12,8 L h-1, having been operated hydraulic system with variable hydraulic detention time of 82-100 minutes. The innovation is based on the use of non-synthetic fabric with three functions: a) providing the flow of the substrate under the action of gravity; b) promote gas exchange between the liquid medium and the atmosphere; c) to establish itself as a means of support biomass and to check the operating conditions and types of blankets to enable wastewater treatment for the removal of carbonaceous matter without the need for artificial aeration. In this study, we analyzed the removal of suspended solids (SS), turbidity, dissolved oxygen, COD and BOD5. The average results of COD removal and BOD in the different operational phases ranged 75-86% and 80 to 86%, respectively. The average concentrations of COD in the final effluent ranged 81-179 mg/L, while the average concentrations of BOD were between 47-97 mg/L. Global average of TSS in the final effluent were maintained on 49 mg/L. To remove turbidity of 92.8%. The PF / BTF (Pre-filter / Biological trickling filter) system can become a very promising alternative for treating sewage from small installations from Brazil, once the system showed low hydraulic retention time and removal efficiency of COD , BOD5 and suspended solids, resulting in a compact installation and low costs. Furthermore, the energy consumption and operating costs are minimal / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
30

Avaliação da toxicidade de efluente sanitário tratado e condicionado para aplicação na agricultura, utilizando Allium cepa, Daphnia similis e Vibrio fischeri, como organismos-teste / Toxicity assessment of treated sanitary effluent for application in agriculture, using Allium cepa, Vibrio fischeri and Daphnia similis as test organisms

Torres, Danila de Leone França e Freitas 21 August 2018 (has links)
Orientador: Alexandre Nunes Ponezi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T07:25:38Z (GMT). No. of bitstreams: 1 Torres_DaniladeLeoneFrancaeFreitas_M.pdf: 2036503 bytes, checksum: 068ab775d9c675592e34d0bfdd2ca1e9 (MD5) Previous issue date: 2012 / Resumo: O uso de efluente tratado na agricultura irrigada constitui uma alternativa adequada para a preservação de mananciais, além de ser uma importante fonte de nutrientes. No entanto, os riscos de toxicidade devem ser avaliados. Testes ecotoxicológicos apresentam-se como uma ferramenta apropriada, devido à sensibilidade dos organismos e sua ampla aceitação por órgãos governamentais e científicos. O objetivo do presente estudo foi avaliar a toxicidade aguda na fotobactéria marinha Vibrio fischeri e no microcrustáceo Daphnia similis (CE50) e do potencial citotóxico, genotóxico e mutagênico em Allium cepa (cebola) de um efluente sanitário tratado usado para irrigação. Os ensaios foram realizados no efluente bruto e nos tratados utilizados para irrigação: anaeróbio e pos-tratamento anaeróbio (nitrificado). Os resultados evidenciaram que o efluente bruto, apresentou uma maior variação dos valores de CE50 para ambos os organismos. O efluente anaeróbio apresentou um efeito tóxico agudo maior para V. fischeri que para D. similis. Já o nitrificado (pos-tratamento anaeróbio) apresentou uma toxicidade aguda menor para ambos os organismos testados. Na avaliação das aberrações cromossômicas em A. cepa, os efluentes tratados apresentaram uma redução do potencial citotóxico (p<0,05) em relação ao efluente bruto. Pode-se concluir que os testes escolhidos foram adequados para o monitoramento do efluente. Recomenda-se que o uso de efluente tratado na agricultura seja realizado de forma regrada, atentando para os padrões de Boas Práticas Agrícolas (GAP) e de toxicidade. Além disso, em escala real é necessário um estudo de monitoramento periódico que avalie impactos a longo prazo, incluindo testes de toxicidade crônica / Abstract: The use of the treated effluent in agriculture has proven to be an important alternative, since its preservation of water and its potential as source of nutrients, with low potential for negative impact on the environment. However, toxicity remains an important issue. Ecotoxicological tests are appropriate tools to evaluate the toxicity of effluents. The aim of this study was to evaluate acute toxicity on marine bacteria Vibrio fischeri, on micro crustacean Daphnia similis (EC50) and on Allium cepa (onion) (assessment of cytotoxic, mutagenic and genotoxic potencial) in treated sanitary effluent used for irrigation. We tested the raw effluent, and in its treatments, used for irrigation: anaerobic and anaerobic posttreatment (nitrified). Our results showed that the raw effluent had a greater variation of EC50 for both organisms, due to an intrinsic variability of its composition. The anaerobic effluent had a greater acute toxic effect on V. fischeri than for D. similis. Yet, the nitrified (anaerobic post-treatment stage) showed a lower toxicity for both tested organisms. We found a reduction in the citotoxical potential in A. cepa as compared to the raw efluente. We concluded that the tests chosen were adequate for monitoring the effluent since the organisms showed adequate sensitivity. It is therefore suggested that the use of treated wastewater in agriculture should be standardized, noting Good Agricultural Practices (GAP) and toxicity stardards. Furthermore for larger scale assumption it is necessary a periodic monitoring study to assess long term impacts, including chronic toxicity tests / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil

Page generated in 1.1191 seconds