Estudo de sensores de baixo custo para estação meteorológica automática / Assessment of low cost sensors for automatic weather stations

Sugawara, Márcio Takeshi 29 August 2003 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-06-23T16:09:19Z No. of bitstreams: 1 texto completo.pdf: 679683 bytes, checksum: 962f9a82b11145d9527fd9f21f1b75ee (MD5) / Made available in DSpace on 2016-06-23T16:09:19Z (GMT). No. of bitstreams: 1 texto completo.pdf: 679683 bytes, checksum: 962f9a82b11145d9527fd9f21f1b75ee (MD5) Previous issue date: 2003-08-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A utilização de estações meteorológicas automáticas é importante para diversas atividades na agricultura moderna, com destaque para o manejo da irrigação, previsão de safra, previsão de doenças e aplicação de defensivos agrícolas. Apesar dos avanços tecnológicos e de preços, tem-se observado, ainda, dificuldades, por parte dos produtores rurais na instalação de estações meteorológicas automáticas, principalmente em razão dos custos de implantação e de manutenção. Assim, este trabalho objetivou o estudo de sensores com componentes eletrônicos comerciais, visando ao desenvolvimento de uma estação meteorológica automática de baixo custo. Os testes foram realizados no Laboratório de Automação e Irrigação de Precisão do Departamento de Engenharia Agrícola da Universidade Federal de Viçosa. Foram testados sensores para medir a temperatura, a umidade relativa e a irradiação solar. Os sensores foram ligados a circuitos divisores de tensão e conectados a um sistema de aquisição automática de dados, ligado a um microcomputador do tipo PC, por meio da porta serial. No sensor de temperatura foi testado o termistor tipo coeficiente de temperatura negativo (NTC) com resistência de 10kΩ, a 25°C, e constante do material de 4000K (óxido de ferro e titânio). Como sensor de irradiação solar foi testado o transistor 2N3055 (Toshiba e SID). No sensor de umidade relativa foi testado o sensor capacitivo HIH-3610 (Honeywell), enquanto o de temperatura teve desempenho adequado, com ajuste linear com r 2 de 99%, e não foi afetado pelo tipo de abrigo, já o sensor de umidade relativa apresentou erros de 4,9 e 2,31% para os abrigos de polietileno e alumínio, respectivamente. Por sua vez, o sensor de radiação apresentou erros de 0,42 e 1,41Wm -2 , respectivamente para os intervalos de 265 a 1,300Wm -2 e 0 a 265Wm -2 . Os resultados indicaram a viabilidade de uso dos sensores alternativos na estação meteorológica, a fim reduzir custos, ressaltando-se que os sensores-teste e o abrigo de sensores representaram 3,7% do custo do sensor-padrão. / This work was carried out to study commercial sensors assessment for low cost automatic weather stations. Tests were carried out at the Laboratório de Automação e Irrigação de Precisão of the Departamento de Engenharia Agrícola (Department of Agricultural Engineering) at the Universidade Federal de Viçosa. Air temperature, relative humidity, and solar radiation commercial sensors were tested. The sensors were linked to electric tension circuits splitter connected to an automatic data acquisition system, and then connected to a PC by the serial port. For air temperature sensor, a type of negative temperature coefficient (NTC) thermistor was used with an electrical resistance of 10 kΩ at 25°C, and a material constant of 4,000 K (iron and titanium oxide). The sensor for solar radiation was a 2N3055 transistor (Toshiba and SID). For the relative humidity sensor, a capacitive HIH-3610 sensor (Honeywell) was tested. While the air temperature sensor presented satisfactory performance, with determination coefficient (r 2 ) of 0.99, it was not affected by the shelter type. The relative humidity sensor presented errors between 4.90 and 2.31% under polyethylene and aluminum shelters, respectively. On the other hand, the solar radiation sensor presented errors of 0.42 and 1.41 Wm -2 , respectively, within the intervals of 265 to 1.300 Wm -2 and 0 to 265 Wm -2 of solar radiation intensities. Results indicated the feasibility of alternative sensors use in meteorological weather stations for cost reduction. The sensors tested and the sensor shelters together made up 3.7% of the total cost as compared to original automatic weather station standard sensor. / Dissertação antiga
2

Desenvolvimento e avaliação de uma estação meteorológica automática para manejo de irrigação / Development and evaluation of an automatic meteorological station for irrigation management

Finholdt, Gustavo 29 July 2008 (has links)
Made available in DSpace on 2015-03-26T13:23:23Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1403387 bytes, checksum: adcffed8a72473707440ee20ce18a3ec (MD5) Previous issue date: 2008-07-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Due to the increasing world population growth, irrigated agriculture is an important strategy to increase food, fiber and agro-energy production. Because of its operationality, irrigation levels determination by means of culture evapotranspiration studies (ETc) has been a widely disseminated and applied technology. Thus, it is necessary to determine a reference evapotranspiration (ETo), which is obtained through data supplied by the Automatic Meteorological Stations (AMS), based on the FAO Penman- Monteith equation, which has a great potential of reducing water consumption and electric energy in irrigation, in addition to reducing potential environmental degradation and labor use. However, the automatic stations are normally imported technologies, with high cost and maintenance, also presenting difficulties in access to maintenance, which is deficient and scarce. Thus, an Automatic Meteorological Station was developed using national technology, designed with five basic sensors (wind velocity, rainfall, air relative humidity, solar irradiance and ambient temperature) to calculate water balance, based on two main parameters: rainfall and ETo. The equipment developed allows data visualization in the equipment itself or in a microcomputer. After the equipment was developed, the sensors were calibrated reaching correlation coefficients (r) of 1,000; 0,998; 0,999; 0,995; and 1,000 for the wind, rainfall, air relative humidity, radiation and temperature sensors, respectively. The equipment was evaluated from 05/17/2008 to 06/12/ 2008 at the meteorological station of the National Instituteof Meteorology (INMET) installed on the Universidade Federal de Viçosa campus. The data were compared taking as reference the INMET s EMA data, model MAWS301 (manufacturer, Vaisala), installed close to the equipment developed. The correlation coefficient estimates (r), mean bias error (MBE) and Root Mean Square Error (RMSE) were used to evaluate the equipment at work. Comparing the equipment data, the following correlation coefficients were obtained: 0.911; 0.999; 0.993; 0.998; and 0.987 of the sensors anemometer, pluviometer, hygrometer, pyranometer and thermometer, respectively. It was concluded that the sensors developed provided adequate results and that the automatic meteorological station developed presented reliable meteorological data measuring and storing conditions. / Devido ao crescente aumento populacional mundial, a agricultura irrigada é uma importante estratégia para maior produção de alimentos, fibras e agroenergia. A determinação da lâmina de irrigação por meio de estudos da evapotranspiração da cultura (ETc) tem sido uma tecnologia amplamente divulgada e utilizada em razão da sua operacionalidade. Para tal, é necessário que se determine a evapotranspiração de referência (ETo) que é obtida com dados advindos de Estações Meteorológicas Automáticas (EMA), com base na equação FAO Penman-Monteith, que tem grande potencial de redução no consumo da água e da energia elétrica nas irrigações, além de reduzir o potencial de degradação ambiental e de utilização da mão-de-obra. No entanto, as estações automáticas são tecnologias normalmente importadas, com alto custo de aquisição e manutenção, que apresentam ainda dificuldades de acesso aos serviços de manutenção, deficientes e pouco disponíveis. Dessa forma, desenvolveu-se uma Estação Meteorológica Automática com tecnologia nacional. A estação foi projetada com os cinco sensores básicos (velocidade do vento, precipitação, umidade relativa do ar, irradiância solar e temperatura ambiente) para calcular o balanço hídrico, sendo dois parâmetros importantes: a precipitação pluvial e a ETo. O equipamento desenvolvido possibilita a visualização dos dados no próprio equipamento ou em um microcomputador. Após o desenvolvimento do equipamento, realizou-se a calibração dos sensores, atingindo coeficientes de correlação (r) de 1,000; 0,998; 0,999; 0,995; e 1,000, para os sensores de vento, chuva, umidade relativa, radiação e temperatura, respectivamente. Em seguida, avaliou-se o equipamento no período de 17/05 a 12/06/2008, na estação meteorológica do Instituto Nacional de Meteorologia (INMET) instalada no campus da Universidade Federal de Viçosa. Os dados foram comparados tomando-se como referência os dados da EMA do INMET, modelo MAWS301 (fabricante Vaisala), instalada ao lado do equipamento desenvolvido. As estimativas de coeficiente de correlação (r), erro de viés médio (MBE) e raiz do erro quadrático médio (RMSE) foram utilizadas para avaliar o funcionamento do equipamento. Com a comparação dos dados dos equipamentos, obtiveram-se os seguintes coeficientes de correlação: 0,911; 0,999; 0,993; 0,998; e 0,987, respectivamente dos sensores anemômetro, pluviômetro, higrômetro, piranômetro e termômetro. Conclui- se que os sensores desenvolvidos proporcionaram resultados adequados e a estação meteorológica automática apresentou condições confiáveis de medição e armazenamento dos dados meteorológicos.