• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 103
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 111
  • 111
  • 68
  • 47
  • 42
  • 26
  • 25
  • 25
  • 22
  • 21
  • 19
  • 18
  • 17
  • 16
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de desempenho de misturas betuminosas com adição de lodos de eta e de ete / Performance evaluation of bituminous mixtures with addition of sludge water and sewage sludge

Martinez, Juan Gabriel Bastidas 05 August 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil, 2014. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2014-10-22T17:42:45Z No. of bitstreams: 1 2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5) / Approved for entry into archive by Tania Milca Carvalho Malheiros(tania@bce.unb.br) on 2014-10-31T16:03:20Z (GMT) No. of bitstreams: 1 2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5) / Made available in DSpace on 2014-10-31T16:03:20Z (GMT). No. of bitstreams: 1 2014_JuanGabrielBastidasMartinez.pdf: 1656961 bytes, checksum: 7869b12a771e890895d24b5a7af2d95c (MD5) / As Estações de Tratamento de Água (ETA) e de Esgoto (ETE) geram como subprodutosde sua operação uma grande quantidade de lodo, que é considerado resíduo sólido pela ABNT10.004/2004 (Associação Brasileira de Normas Técnicas). A disposição final dos resíduos, semum adequado gerenciamento, pode resultar em danos aos seres humanos e ao meio ambiente constituindo-se em passivo ambiental a evitar. Este trabalho teve como finalidade verificar a possibilidade de utilização dos referidos resíduos em concreto betuminoso usinado a quente proporcionando a sua melhoria de comportamento, sem levar em conta nessa fase inicial os custos diretos do tratamento e nem do passivo ambiental. Para possibilitar a incorporação dos resíduos lodos de ETA e de ETE no Concreto Asfáltico utilizou-se um moinho mecânico a fim de tornar o material passante pela peneira número 200. Os resíduos foram adicionados à misturas de duas formas: i) via úmida; ii) via seca. Na primeira, se colocaram em várias temperaturas de secagem (200°C, 300°C, 500°C, 800°C e seco ao ar) ao ligante asfáltico, já no segundo caso, realizando secagem a 175 °C para logo ser adicionado ao agregado miúdo. A interação ligante-lodos foi avaliada por meio dos ensaios de massa especifica, consistência e perda de massa ou variação RTFOT. Os lodos de ETA calcinados a 500°C apresentaram melhoria nas propriedades mecânicas e de adesividade. Já os lodos de ETE, secos à temperatura de aquecimento do ligante, e adicionados sobre o agregado miúdo apresentaram incrementos nas propriedades mecânicas. O estudo permitiu concluir que a utilização dos lodos de ETA ede ETE no concreto betuminoso para fins de construção rodoviária é viável quanto aos aspectos técnico e ambiental, sendo que pesquisas futuras serão importantes para um maior entendimento do comportamento dessas misturas e validação das conclusões a que se chegou. _______________________________________________________________________________________ ABSTRACT / Water Treatment Stations (WTS) and Sewage Treatment Stations (STS) generates alarge amount of sludge as products of their operations, these products are considered solid wasteby the ABNT 10004/2004 (Associação Brasileira de Normas Técnicas), and, without a propermanagement, the final disposal of waste can result harmful to the humanity and to theenvironment by cause pollution. So, that is an environmental issue to be avoided. This studyaimed to verify the usability of such waste in asphalt binders for hot asphalt concrete to knowif is this mixture could provide an improvement in its behavior, without taking into account, inthis initial phase, the direct costs of treatment and/or environmental liabilities. To facilitate theincorporation of WTS and STS sludge waste into the asphalt concrete was used a mechanicmill, in order to make the material pass through the sieve number 200. The residues were addedto the mixture by two ways: i) dry, and ii) wet. The first mixture was made subjecting thesamples to several high drying temperatures (200°C, 300°C, 500°C, 800°C and air dried) tothen add the asphalt binder; in the second case, the sludge was dried at 175 °C and added intothe fine aggregate. The sludge-ligand interaction was evaluated by the specific gravity tests, theconsistency and by the weight loss or variation RTFOT. The calcined WTS sludge (500 °C)showed improvement in mechanical and adhesion properties. While the STS sludge, dried atthe binder heating temperature, and added over the fine aggregate, showed increase only inmechanical properties. Therefore, the study conclude that the use of WTS and STS sludge’s inasphalt concrete, for road construction, is viable for technical and environmental aspects,however, future studies are needed to validate these results.
12

Influência da recirculação de água de lavagem de filtros na qualidade da água tratada para consumo humano / Influence of recirculation of water to wash filters in treated water quality for human consumption

Campos, Marlon Caianelo Dias, 1986- 24 August 2018 (has links)
Orientador: Ricardo de Lima Isaac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T14:00:51Z (GMT). No. of bitstreams: 1 Campos_MarlonCaianeloDias_M.pdf: 3410126 bytes, checksum: bb9db3577d3074777f6ae59b1de2ad29 (MD5) Previous issue date: 2014 / Resumo: A recirculação de água de lavagem de filtro em estação de tratamento de água do tipo convencional (ETA) pode representar economia significativa tanto do recurso hídrico quanto de energia, aspecto fundamental do ponto de vista da sustentabilidade. Contudo, se praticada sem critério, tal prática operacional pode representar risco à saúde do consumidor. O objetivo geral desta pesquisa foi avaliar o impacto da recirculação da água de lavagem de filtros (ALAF) na qualidade da água tratada. O trabalho desenvolveu-se na ETA-3 de Campinas-SP que capta do manancial superficial (rio Atibaia), utiliza pré-cloração e policloreto de alumínio como coagulante no processo de tratamento. Investigou-se em escala de bancada (Jar-test) o impacto da aplicação de taxas de recirculação equivalentes a 2, 4, 6, 8 e 10 % em volume de ALAF em relação ao volume total de água tratada na formação de subprodutos de desinfecção (trihalomeanos e ácidos haloacéticos). Os parâmetros carbono orgânico total (COT), carbono orgânico dissolvido (COD), UV254, turbidez, cor (aparente e verdadeira) e metais (alumínio, bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) foram também avaliados. Em geral, as diferentes taxas de recirculação de ALAF não provocaram inadequações quanto ao padrão de potabilidade para os parâmetros: cor, turbidez, metais (bário, cádmio, chumbo, cobre, cromo, manganês, zinco e níquel) e trihalometanos. Quanto aos ácidos haloáceticos, porém, notou-se que não se atendeu ao valor limite estabelecido na legislação e que o aumento da taxa de recirculação provocou a elevação da concentração deste subproduto da desinfecção na água tratada / Abstract: Filter backwash water recycling at conventional water treatment plants (WTP) certainly contributes to water and energy resources rational use, essential for sustainability. However, if practiced without criteria, such operational practice may pose a risk to users¿ health. The overall objective of this research was to evaluate the impact of recirculating filter backwash water on filtered water quality. The work was carried out at Campinas WTP, Sao Paulo State, Brazil. The plant treats surface raw water from Rio Atibaia (pre-chlorination, polyaluminum chloride as main coagulant). It was investigated in lab scale (jar-test) the effect of applying recirculation flowrate corresponding to 2, 4, 6, 8 and 10 % volume of backwash water ratio to total volume of treated water on the formation of disinfection byproducts (trihalomethane, THM and haloacetic acids, HAA). Metals content (aluminum , barium, cadmium, lead, copper, chromium , manganese, zinc and nickel), total organic carbon (TOC), dissolved organic carbon (DOC) , UV254 , turbidity, apparent and true color were also evaluated . In general, tested recirculation rates did not cause filtered water quality mismatches to drinking water standards for the parameters: color, turbidity, metals (barium, cadmium, lead, copper, chromium, manganese, zinc and nickel) and THM. However, for HAA it was found that recycling led to concentration values upper than the maximum contaminant level in Brazilian drinking water standards. Increasing the rate, higher was the concentration of this disinfection by-product in treated water / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
13

Protótipo de biofiltro percolador com uso de meio suporte sintético / Prototype of biofilter percolator with synthetic support

Bergamini, Natália Cedran, 1984- 26 August 2018 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T02:02:33Z (GMT). No. of bitstreams: 1 Bergamini_NataliaCedran_M.pdf: 5745897 bytes, checksum: 69560c23a66d8d968b36f4b34e17bc8d (MD5) Previous issue date: 2014 / Resumo: Este trabalho consistiu em inovação tecnológica antes nunca testada desde a concepção, projeto, construção e operação de um biofiltro percolador de tratamento de esgoto sanitário em escala piloto. O reator foi desenvolvido nas instalações do Laboratório de Protótipos da Faculdade de Engenharia Civil da UNICAMP, cidade de Campinas, estado de São Paulo, é constituído de pré-filtro fabricado com a manta acrílica resinada, 3 reatores biológicos percoladores dispostos em séries, revestidos de não tecido sintético e filtro secundário confeccionado do mesmo material do pré-filtro. A vazão real média de alimentação do sistema era de 12,8 L h-1, tendo sido operado em regime hidráulico com tempo de detenção hidráulico variável de 82 a 100 minutos. A inovação baseou-se no uso de não tecido sintético com tripla função: a) proporcionar o fluxo do substrato sob ação da gravidade; b) promover a troca gasosa entre o meio líquido e a atmosfera; e c) constituir-se como meio suporte da biomassa, além de verificar as condições operacionais e tipos de mantas para viabilizar o tratamento de esgoto na remoção de matéria carbonácea sem a necessidade de aeração artificial. Neste estudo, foi analisada a remoção de sólidos suspensos (SS), turbidez, oxigênio dissolvido, DQO e DBO5. Os resultados médios de remoção de DQO e de DBO nas diferentes fases operacionais variaram de 75 a 86% e de 80 a 86%, respectivamente. As concentrações médias de DQO no efluente final variaram de 81 a 179 mg/L, enquanto as concentrações médias de DBO estiveram entre 47 a 97 mg/L. As médias globais de SST no efluente final foram mantidas em 49 mg/L. Com remoção de turbidez de 92,8%. O sistema PF/FBP (Pré-filtro/Filtro Biológico Percolador) pode se tornar uma alternativa muito promissora para o tratamento de esgoto sanitário de pequenas instalações do Brasil, uma vez que o sistema manifestou baixos tempo de detenção hidráulica e eficiência na remoção de DQO, DBO5 e sólidos suspensos, resultando em uma instalação compacta e de baixos custos. Além disso, o consumo de energia e os custos operacionais são mínimos / Abstract: This work consisted in technological innovation never before tested from conception, design, construction and operation of a trickling biofilter wastewater treatment in pilot scale. The reactor was developed on the premises of the Laboratory Prototypes of the Faculty of Civil Engineering, UNICAMP, Campinas, São Paulo, is constituted of prefilter manufactured with resin-coated acrylic blanket, three biological trickling reactors arranged in series, coated and synthetic nonwoven secondary filter made of the same material pre-filter. The average real power flow of the system was 12,8 L h-1, having been operated hydraulic system with variable hydraulic detention time of 82-100 minutes. The innovation is based on the use of non-synthetic fabric with three functions: a) providing the flow of the substrate under the action of gravity; b) promote gas exchange between the liquid medium and the atmosphere; c) to establish itself as a means of support biomass and to check the operating conditions and types of blankets to enable wastewater treatment for the removal of carbonaceous matter without the need for artificial aeration. In this study, we analyzed the removal of suspended solids (SS), turbidity, dissolved oxygen, COD and BOD5. The average results of COD removal and BOD in the different operational phases ranged 75-86% and 80 to 86%, respectively. The average concentrations of COD in the final effluent ranged 81-179 mg/L, while the average concentrations of BOD were between 47-97 mg/L. Global average of TSS in the final effluent were maintained on 49 mg/L. To remove turbidity of 92.8%. The PF / BTF (Pre-filter / Biological trickling filter) system can become a very promising alternative for treating sewage from small installations from Brazil, once the system showed low hydraulic retention time and removal efficiency of COD , BOD5 and suspended solids, resulting in a compact installation and low costs. Furthermore, the energy consumption and operating costs are minimal / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
14

Estratégias de gestão de lamas das estações de tratamento de águas residuais (ETAR) : estrusão de lamas para aplicação na agricultura

Sousa, Ricardo José Vieira de January 2005 (has links)
Tese de mestrado. Engenharia do Ambiente (Ramo de Gestão e Tratamento de Resíduos Industriais). Faculdade de Engenharia. Universidade do Porto. 2005
15

Acompanhamento do arranque/exploração de uma ETAR

Cerdeira, Lara Alexandra Brioso Moreno January 2008 (has links)
Estágio realizado na EFACEC-Ambiente e orientado pelo Eng.ª Isabel saraiva e Eng.ª Maria Amélia Fonseca / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2008
16

Estudo das emissões gasosas por processos de desodorização

Sousa, Vera Mónica Almeida de January 2009 (has links)
Estágio realizado na EFACEC Ambiente, S. A. e orientado pelo Eng.ª Amélia Fonseca / Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2009
17

Aplicação da avaliação do ciclo de vida a duas estações de tratamento de água da região Norte : ETA de Queimada e ETA de Areias de Vilar

Sousa, Ana Luísa Seixas January 2009 (has links)
Estágio realizado na Águas do Ave, S.A. e orientado pelo Eng.ª Rita Emília Silva Oliveira / Tese de mestrado integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2009
18

Impacto de descargas de efluentes agro-alimentares nas ETAR da ATMAD

Costa, Eurico Manuel Pinho da January 2009 (has links)
Estágio realizado na ATMAD e orientado pelo Eng.ª Isabel Pereira / Tese de mestrado integrado. Engenharia do Ambiente (Especialização em gestão). Faculdade de Engenharia. Universidade do Porto. 2009
19

Estudo da hidrodinâmica do processo de ozonização da ETA de Lever

Cavalheiro, Catarina Ferreira das Neves January 2005 (has links)
Tese de mestrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2005
20

Modelação e avaliação do impacto das descargas de efluente tratado nas ETAR da Bacia do Rio Lima

Restivo, João Monteiro de Oliveira January 2009 (has links)
Estágio realizado nas Águas do Minho e Lima e orientado pelo Eng.º Pedro Bastos / Tese de mestrado integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2009

Page generated in 0.3287 seconds