1

Avaliação  da estabilidade primária de diferentes implantes, por meio de ensaios biomecânicos, análises radiográficas, tomográficas, histomorfométricas. Estudo in vitro / Evaluation of primary implant stability by biomechanical testing, radiographic, CT, histomorphometric analysis. In vitro study

Dantas, Carolina Delmondes Freitas 22 August 2016 (has links)
A estabilidade primária, após a instalação do implante, é uma condição essencial para a aplicação de carga imediata, situação clínica cada vez mais desejada por profissionais e pacientes. O presente estudo tem como objetivo avaliar a estabilidade primária de cinco diferentes implantes instalados em bases ósseas padronizadas de osso suíno e blocos de poliuretano (modelos in vitro), por meio de ensaios biomecânicos e análise de imagens (microtomográficas e histomorfométricas). Para certificação e padronização dos cilindros de osso suíno, foram realizadas tomadas radiográficas digitais, determinando cilindros ósseos de alta e baixa densidades. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (BV/TV); Separação Trabecular (Tb.Sp); Porcentagem de Poros Abertos (Po.Op); Porcentagem de Poros Fechados (Po.Cl) e Porcentagem de Porosidade Total (Po.Tot). Esses parâmetros foram avaliados em quatro níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N3 distante 0,5 mm a 1,5 mm do final das roscas; N4 área óssea de 0 a 0,5mm da apical do implante). Depois disso, foram selecionados 50 implantes de 5 diferentes modelos, divididos em 5 grupos com 10 implantes cada: Grupo 1 (G1): implantes Xive Plus inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 2 (G2): implantes Ankylos inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 3 (G3): implantes Bone Level inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 4 (G4): implantes AlvimCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 5 (G5): implantes DriveCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5). A instalação de todos implantes seguiu o protocolo recomendado pelos fabricantes, sendo realizada a medida do torque de inserção (IT) e logo após a análise de Coeficiente de Estabilidade do Implante - ISQ (avaliação por Frequência de ressonância - RFA). Após a instalação dos implantes nos cilindros ósseos, estes foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos. Para as análises nos blocos de poliuretano, foram seccionados 50 blocos de alta e baixa densidade (D1 e D3, respectivamente), e inseridos 50 implantes individualmente nos blocos, utilizando 10 de cada e divididos em 5 grupos: Grupo 6 (G6): implantes Xive Plus inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 7 (G7): implantes Ankylos inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 8 (G8): implantes Bone Level inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes AlvimCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes DriveCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5). Após a inserção dos implantes, estes também foram analisados com relação ao torque de inserção, frequência de ressonância e através do ensaio de arrancamento. Os ensaios biomecânicos mostraram que os implantes instalados no G4 (AlvimCM) e G5 (DriveCM) tiveram maior valores de IT e de RFA em ambas as bases ósseas suínas. Nos blocos de poliuretano, tiveram resultados semelhantes entre as bases ósseas para quase todos os implantes nos testes IT e RFA, havendo um maior valor no ensaio de arrancamento para os implantes Bone Level (G8). Os resultados para todas os parâmetros avaliados por MicroCT mostraram que as diferenças dos valores pós e pré-inserção dos implantes revelaram significância estatística principalmente para G4 e G5 em relação aos outros grupos. A análise histomorfométrica mostrou maiores valores de compactação óssea e de Contato Osso-Implante (BIC) para G2, G4 e G5. Para todas as análises de imagem foi observada uma tendência de maior compactação nos N1, N2 e N4; no N3 não houve um aumento significativo da condensação óssea pós-inserção do implante. Concluiu-se que os implantes AlvimCM e DriveCM mostraram melhores resultados nos testes biomecânicos e em relação ao aumento da densidade óssea ao redor do implante, avaliada pelos métodos de imagem, e que estes resultados estiveram correlacionados à estabilidade primária exibida pós-inserção. Os resultados histomorfométricos confirmaram os resultados obtidos pela análise microtomográfica, demonstrando assim a validade do método 3D de análise por imagem. / The primary stability, after implant installation, is an essential condition for the application of immediate loading, clinical situation increasingly desired by professionals and patients. The present study has the objective of evaluating the primary stability of five different implants installed in standard bone bases of swine bone and polyurethane blocks (in vitro models), through biomechanical tests and image analysis (microtomographic and histomorphometric). For the certification and standardization of the swine bone cylinders, digital radiographs were taken, determining bone cylinders of high and low density. After the certification, computerized microtomographies of the bone cylinders were performed for three-dimensional analysis of images prior to implant installation, evaluating the following parameters: Three-dimensional Bone Density (BV / TV); Trabecular Separation (Tb.Sp); Percent of Open Pore (Po.Op); Percent of Closed Pores (Po.Cl) and Percentage of Total Porosity (Po.Tot). These parameters were evaluated in four bone levels (N1 - internal to the threads of the implant to be installed, N2 - adjacent to the end of the threads up to 0.5 mm of these, N3 - distant 0.5 mm to 1.5 mm from the end of the threads ; N4 - bone area 0 to 0.5 mm from the apical of the implant). After that, 50 implants of 5 different models were divided into 5 groups with 10 implants each: Group 1 (G1): Xive Plus implants inserted into high (n = 5) and low density (n = 5) ; Group 2 (G2): Ankylos implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 3 (G3): Bone Level implants inserted into bone cylinders of high (n = 5) and low density (n = 5); Group 4 (G4): AlvimCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 5 (G5): DriveCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders. The implantation of all implants followed the protocol recommended by the manufacturers, and the measurement of the insertion torque (IT) and soon after the analysis of Implantation Stability Coefficient (ISQ (evaluation by Frequency of Resonance - RFA)). After the implants were installed in the bone cylinders, they were submitted to a new three-dimensional analysis with the same parameters and bone levels. 50 blocks of high and low density (D1 and D3, respectively), and 50 implants were inserted individually into the blocks, using 10 of each and divided into 5 groups: Group 6 (G6): implants Xive Plus inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 7 (G7): Ankylos implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 8 (G8): Bone Level implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): AlvimCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): DriveCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5). After insertion of the implants, these were also analyzed with respect to the insertion torque, resonance frequency and through the pullout test. The biomechanical tests showed that the implants installed in G4 (AlvimCM) and G5 (DriveCM) had higher IT and RFA values in both porcine bone bases. In the polyurethane blocks, similar results were found between the bone bases for almost all implants in the IT and RFA tests, with a higher value in the pullout test for Bone Level (G8) implants. The results for all the parameters evaluated by MicroCT showed that the differences in the post-insertion and pre-insertion values of the implants revealed statistical significance mainly for G4 and G5 in relation to the other groups. The histomorphometric analysis showed higher Bone Compaction and Bone Implant (BIC) compaction values for G2, G4 and G5. For all the image analyzes a tendency of greater compaction was observed in N1, N2 and N4; in N3 there was no significant increase in bone post-insertion implant condensation. It was concluded that the AlvimCM and DriveCM implants showed better results in the biomechanical tests and in relation to the increase of the bone density around the implant, evaluated by the imaging methods, and that these results were correlated to the primary stability exhibited post-insertion. The histomorphometric results confirmed the results obtained by the microtomographic analysis, thus demonstrating the validity of the 3D image analysis method.
2

Avaliação da estabilidade primária de implantes convencionais e modificados por meio de ensaios de desempenho, frequência de ressonância e análise microestrutural / Evaluation of primary stability of conventional and modified implants by the performance tests, resonance frequency and microstructural analysis

Valente, Mariana Lima da Costa 09 October 2014 (has links)
A estabilidade primária dos implantes odontológicos é determinante para a osseointegração e depende dos fatores qualidade, quantidade óssea e tipo de implante. O objetivo desse estudo foi avaliar a influência do formato de implantes convencionais e modificados e do tipo de substrato na estabilidade primária por meio da correlação de ensaios de desempenho e frequência de ressonância e análise microestrutural. No estudo foram utilizados 54 implantes Neodent®: 27 cilíndricos, sendo 9 hexágono externo (Titamax Ti Cortical - 4,0 mm x 11 mm), 9 hexágono interno (Titamax II Plus - 3,75 mm x 11 mm) e 9 cone morse (Titamax CM - 4,0 mm x 11 mm); e 27 implantes cônicos de 4,3 mm x 10 mm, sendo 9 hexágono externo (Alvim Ti), 9 hexágono interno (Alvim II Plus) e 9 cone morse (Alvim CM). Os implantes foram inseridos em osso artificial da marca Nacional® nas densidades de 15, 20 e 40 PCF e osso de costela suína. Para os ensaios de desempenho foi quantificado o torque de inserção com um torquímetro digital e a força máxima de arrancamento utilizando uma Máquina Universal de Ensaios. Para avaliar a frequência de ressonância foi utilizado o aparelho Ostell® e para a análise morfológica um Microscópio Eletrônico de Varredura, sob aumentos de 40 e 100 vezes. Após a realização dos ensaios com os implantes convencionais, os modelos Alvim CM e Titamax Ti Cortical (n=9) tiveram sua morfologia externa alterada com a prolongação dos chanfros desde o terço apical até o nível da plataforma protética e foram submetidos aos mesmos testes propostos para os parafusos originais. Verificada a normalidade dos dados utilizou-se o teste de análise de variância ANOVA, comparação de médias Tukey (α=5%) e correlação de Pearson. Para os implantes convencionais, o Alvim CM apresentou maior média em todos os ensaios realizados, sendo estatisticamente diferente dos implantes cilíndricos quando analisado o torque de inserção no osso (73,33 N.cm) e força de arrancamento na poliuretana de 40 PCF (910,36 N) e osso (553,79 N). Os implantes Titamax II Plus tiveram as menores médias, diferente estatisticamente dos cônicos quando analisado o torque de inserção (22,22 N.cm) e frequência de ressonância no osso (72,83 ISQ) e força de arrancamento na poliuretana de 40 PCF (61,97 N) e osso (86,40 N). A análise dos ensaios de desempenho e frequência de ressonância apresentou correlação moderada de acordo com o p de Pearson (0,30 a 0,70) e a comparação entre as fotomicrografias não mostrou alteração morfológica dos implantes. A modificação realizada no parafuso Alvim CM proporcionou um aumento significativo no torque de inserção (p=0,000), diminuição das médias de arrancamento (p=0,000) e manteve semelhança com as médias de frequência de ressonância (p=0,169) quando comparado ao implante convencional. O Titamax Ti modificado aumentou significativamente o torque de inserção (p=0,043) e provocou diminuição significativa para a frequência de ressonância (p=0,002) e ensaio de arrancamento (p=0,000). Conclui-se que o formato dos implantes interfere na estabilidade primária, sendo os implantes cônicos indutores de maior estabilidade. A análise de correlação das metodologias empregadas demonstrou a associação positiva das mesmas para complementação da análise da estabilidade primária / The primary stability of dental implants is critical for osseointegration and depends on factors quality, bone quantity and type of implant. The aim of this study was to evaluate the influence of conventional and modified implants and the type of substrate shape on primary stability through the correlation of performance tests and frequency of resonance and microstructural analysis. In the study 54 Neodent® implants were used: 27 cylindrical, 9 hexagonal (Titamax Ti Cortical - 4.0 mm x 11 mm), 9 internal hexagon (Titamax II Plus - 3.75 mm x 11 mm) and 9 morse taper (Titamax CM - 4.0 mm x 11 mm); and 27 tapered implants of 4.3 mm x 10 mm and 9 external hexagon (Alvim Ti), 9 internal hexagon (Alvim II Plus) and 9 morse taper (Alvim CM). The implants were inserted into artificial bone of National ® brand at densities of 15, 20 and 40 PCF and pork rib bone. For testing the performance was quantified insertion torque with a digital torque meter and the maximum pullout strength using a universal testing machine. To evaluate the resonance frequency was used Ostell ® device and the morphological parsing an Scanning Electron Microscope under increases of 40 and 100 times. After the tests with conventional implants, models CM Alvim and Titamax Cortical Ti (n=9) had their external morphology changed with the prolongation of the bevels from the apical to the level of prosthetic platform and underwent the same tests proposed for the original screws. Checked for normality of the data used in the test of ANOVA, Tukey comparison (α=5%) and Pearson correlation. For conventional implants, the CM Alvim showed higher average in all tests, with statistically different when analyzed cylindrical implant insertion torque on bone (73.33 N.cm) and pullout strength in polyurethane 40 PCF (910.36 N) and bone (553.79 N). Implants Titamax II Plus had the lowest average, statistically different when analyzed the tapered insertion torque (22.22 N.cm) and resonance frequency in bone (72.83 ISQ) and pullout strength in 40 PCF polyurethane (61.97 N) and bone (86.40 N). The analysis of the performance tests and had moderate resonance frequency correlation according op Pearson (0.30 to 0.70) and comparing the photomicrographs showed no morphological alteration of the implants. The modification made to the screw Alvim CM provided a significant increase in insertion torque (p=0.000), decrease of average pullout (p=0.000) and remained similar to the average resonance frequency (p=0.169) when compared to the implant conventional. The Titamax Ti modified significantly increased insertion torque (p=0.043) and caused a significant decrease in the resonance frequency (p=0.002) and pullout test (p=0.000). It is concluded that the shape of the implants interfere with the primary stability, with the inductors tapered implants stability. Correlation analysis of the methodologies used showed a possible association of these for further analysis of primary stability
3

Avaliação  da estabilidade primária de diferentes implantes, por meio de ensaios biomecânicos, análises radiográficas, tomográficas, histomorfométricas. Estudo in vitro / Evaluation of primary implant stability by biomechanical testing, radiographic, CT, histomorphometric analysis. In vitro study

Carolina Delmondes Freitas Dantas 22 August 2016 (has links)
A estabilidade primária, após a instalação do implante, é uma condição essencial para a aplicação de carga imediata, situação clínica cada vez mais desejada por profissionais e pacientes. O presente estudo tem como objetivo avaliar a estabilidade primária de cinco diferentes implantes instalados em bases ósseas padronizadas de osso suíno e blocos de poliuretano (modelos in vitro), por meio de ensaios biomecânicos e análise de imagens (microtomográficas e histomorfométricas). Para certificação e padronização dos cilindros de osso suíno, foram realizadas tomadas radiográficas digitais, determinando cilindros ósseos de alta e baixa densidades. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (BV/TV); Separação Trabecular (Tb.Sp); Porcentagem de Poros Abertos (Po.Op); Porcentagem de Poros Fechados (Po.Cl) e Porcentagem de Porosidade Total (Po.Tot). Esses parâmetros foram avaliados em quatro níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N3 distante 0,5 mm a 1,5 mm do final das roscas; N4 área óssea de 0 a 0,5mm da apical do implante). Depois disso, foram selecionados 50 implantes de 5 diferentes modelos, divididos em 5 grupos com 10 implantes cada: Grupo 1 (G1): implantes Xive Plus inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 2 (G2): implantes Ankylos inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 3 (G3): implantes Bone Level inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 4 (G4): implantes AlvimCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5); Grupo 5 (G5): implantes DriveCM inseridos em cilindros ósseos de alta (n=5) e de baixa densidades (n=5). A instalação de todos implantes seguiu o protocolo recomendado pelos fabricantes, sendo realizada a medida do torque de inserção (IT) e logo após a análise de Coeficiente de Estabilidade do Implante - ISQ (avaliação por Frequência de ressonância - RFA). Após a instalação dos implantes nos cilindros ósseos, estes foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos. Para as análises nos blocos de poliuretano, foram seccionados 50 blocos de alta e baixa densidade (D1 e D3, respectivamente), e inseridos 50 implantes individualmente nos blocos, utilizando 10 de cada e divididos em 5 grupos: Grupo 6 (G6): implantes Xive Plus inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 7 (G7): implantes Ankylos inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 8 (G8): implantes Bone Level inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes AlvimCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5); Grupo 9 (G9): implantes DriveCM inseridos em blocos de poliuretano de alta densidade - D1 (n=5) e de baixa densidade - D3 (n=5). Após a inserção dos implantes, estes também foram analisados com relação ao torque de inserção, frequência de ressonância e através do ensaio de arrancamento. Os ensaios biomecânicos mostraram que os implantes instalados no G4 (AlvimCM) e G5 (DriveCM) tiveram maior valores de IT e de RFA em ambas as bases ósseas suínas. Nos blocos de poliuretano, tiveram resultados semelhantes entre as bases ósseas para quase todos os implantes nos testes IT e RFA, havendo um maior valor no ensaio de arrancamento para os implantes Bone Level (G8). Os resultados para todas os parâmetros avaliados por MicroCT mostraram que as diferenças dos valores pós e pré-inserção dos implantes revelaram significância estatística principalmente para G4 e G5 em relação aos outros grupos. A análise histomorfométrica mostrou maiores valores de compactação óssea e de Contato Osso-Implante (BIC) para G2, G4 e G5. Para todas as análises de imagem foi observada uma tendência de maior compactação nos N1, N2 e N4; no N3 não houve um aumento significativo da condensação óssea pós-inserção do implante. Concluiu-se que os implantes AlvimCM e DriveCM mostraram melhores resultados nos testes biomecânicos e em relação ao aumento da densidade óssea ao redor do implante, avaliada pelos métodos de imagem, e que estes resultados estiveram correlacionados à estabilidade primária exibida pós-inserção. Os resultados histomorfométricos confirmaram os resultados obtidos pela análise microtomográfica, demonstrando assim a validade do método 3D de análise por imagem. / The primary stability, after implant installation, is an essential condition for the application of immediate loading, clinical situation increasingly desired by professionals and patients. The present study has the objective of evaluating the primary stability of five different implants installed in standard bone bases of swine bone and polyurethane blocks (in vitro models), through biomechanical tests and image analysis (microtomographic and histomorphometric). For the certification and standardization of the swine bone cylinders, digital radiographs were taken, determining bone cylinders of high and low density. After the certification, computerized microtomographies of the bone cylinders were performed for three-dimensional analysis of images prior to implant installation, evaluating the following parameters: Three-dimensional Bone Density (BV / TV); Trabecular Separation (Tb.Sp); Percent of Open Pore (Po.Op); Percent of Closed Pores (Po.Cl) and Percentage of Total Porosity (Po.Tot). These parameters were evaluated in four bone levels (N1 - internal to the threads of the implant to be installed, N2 - adjacent to the end of the threads up to 0.5 mm of these, N3 - distant 0.5 mm to 1.5 mm from the end of the threads ; N4 - bone area 0 to 0.5 mm from the apical of the implant). After that, 50 implants of 5 different models were divided into 5 groups with 10 implants each: Group 1 (G1): Xive Plus implants inserted into high (n = 5) and low density (n = 5) ; Group 2 (G2): Ankylos implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 3 (G3): Bone Level implants inserted into bone cylinders of high (n = 5) and low density (n = 5); Group 4 (G4): AlvimCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders; Group 5 (G5): DriveCM implants inserted into high (n = 5) and low density (n = 5) bone cylinders. The implantation of all implants followed the protocol recommended by the manufacturers, and the measurement of the insertion torque (IT) and soon after the analysis of Implantation Stability Coefficient (ISQ (evaluation by Frequency of Resonance - RFA)). After the implants were installed in the bone cylinders, they were submitted to a new three-dimensional analysis with the same parameters and bone levels. 50 blocks of high and low density (D1 and D3, respectively), and 50 implants were inserted individually into the blocks, using 10 of each and divided into 5 groups: Group 6 (G6): implants Xive Plus inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 7 (G7): Ankylos implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 8 (G8): Bone Level implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): AlvimCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5); Group 9 (G9): DriveCM implants inserted in blocks of high density polyurethane - D1 (n = 5) and low density - D3 (n = 5). After insertion of the implants, these were also analyzed with respect to the insertion torque, resonance frequency and through the pullout test. The biomechanical tests showed that the implants installed in G4 (AlvimCM) and G5 (DriveCM) had higher IT and RFA values in both porcine bone bases. In the polyurethane blocks, similar results were found between the bone bases for almost all implants in the IT and RFA tests, with a higher value in the pullout test for Bone Level (G8) implants. The results for all the parameters evaluated by MicroCT showed that the differences in the post-insertion and pre-insertion values of the implants revealed statistical significance mainly for G4 and G5 in relation to the other groups. The histomorphometric analysis showed higher Bone Compaction and Bone Implant (BIC) compaction values for G2, G4 and G5. For all the image analyzes a tendency of greater compaction was observed in N1, N2 and N4; in N3 there was no significant increase in bone post-insertion implant condensation. It was concluded that the AlvimCM and DriveCM implants showed better results in the biomechanical tests and in relation to the increase of the bone density around the implant, evaluated by the imaging methods, and that these results were correlated to the primary stability exhibited post-insertion. The histomorphometric results confirmed the results obtained by the microtomographic analysis, thus demonstrating the validity of the 3D image analysis method.
4

Avaliação da estabilidade primária de dois tipos de implantes instalados em modelos ósseos suínos padronizados, utilizando ensaios biomecânicos e micro-CT. Estudo piloto in vitro / Evaluation of primary stability of two types of implants installed in standardized porcine bone models, using biomechanical tests and Micro- CT in vitro study

Carolina Delmondes Freitas Dantas 31 May 2012 (has links)
Estabilidade primária adequada em densidades ósseas de resistências variadas é um dos fatores importantes para o sucesso da osseointegração. O objetivo deste estudo foi avaliar comparativamente a estabilidade inicial de diferentes tipos de implantes, utilizando cilindros ósseos padronizados de origem suína, de alta e baixa densidades, em modelo in vitro, por meio de Análises Tri-dimensionais (microtomografia computadorizada); Torque de Inserção e Ensaio de Arrancamento. Os cilindros ósseos foram preparados a partir de osso suíno, retirados do côndilo mandibular ou da cabeça do fêmur, e separados em 2 grupos: Grupo A: cilindros removidos da cabeça do fêmur (alta densidade óssea), e Grupo B: cilindros removidos do côndilo mandibular (baixa densidade óssea). Previamente aos procedimentos experimentais os cilindros ósseos foram certificados por meio de análises de imagens 2D e 3D, para garantir a uniformidade intra-grupos e distinção entre-grupos dos espécimes. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos, para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (DOT); Separação Trabecular (STB); Porcentagem de Poros Abertos (PPA); Porcentagem de Poros Fechados (PPF) e Porcentagem de Porosidade Total (PPT). Esses parâmetros foram avaliados em três níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N distante 0,5 mm a 1,5 mm do final das roscas). Depois disso, foram selecionados 20 implantes (Titaniumfix®) de dois modelos, divididos em 4 grupos, cada um com 05 implantes: Grupo 1 (G1): Implante e-Fix HE instalado em cilindro ósseo de alta densidade; Grupo 2 (G2): Implante e-Fix HE instalado em cilindro ósseo de baixa densidade; Grupo 3 (G3): Implante e-Fix HE Silver instalado em cilindro ósseo de alta densidade; Grupo 4 (G4) : Implante e-Fix HE Silver instalado em cilindro ósseo de baixa densidade. A instalação dos implantes seguiu o protocolo recomendado pelo fabricante, e durante o procedimento foi feita a medida do torque de inserção. Após a instalação dos implantes, todos os cilindros ósseos foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos previamente descritos, e ao ensaio de arrancamento. Os resultados das análises tridimensionais mostraram diferenças estatisticamente significantes intra grupos nas situações pré- e pós-implantes para G3 e G4, em todos os níveis e para todos os parâmetros tomográficos. Observou-se também no Nível 2 diferenças estatisticamente significantes intra grupos para todos os grupos e todos os parâmetros. No nível 3, foi observado um comprometimento nos valores dos parâmetros DOT e PPA, eststisticamente significante para G1, G3 e G4, e numericamente pronunciado no G2 (Teste de Friedman, p<0,05). Os ensaios biomecânicos mostraram que os implantes instalados no G3 (e-Fix HE Silver) tiveram maior torque de inserção e maior resistência ao arrancamento quando comparados ao mesmo tipo de implante instalado no G4 e aos implantes do modelo e-fix HE instalados no G2 (teste de Friedman, p<0,05). Concluiu-se que a metodologia apresentada gera cilindros ósseos padronizados de alta e baixa densidades, o formato dos implantes e-Fix Silver mostrou melhores resultados nos testes biomecânicos e a densidade óssea radiográfica e tomográfica correlacionou-se à estabilidade primária. / This study comparatively evaluated the primary stability of two different implants, placed in standardized porcine bone cylinders of high and low density, analyzing 3D images (computerized micro tomography - micro-CT), insertion torque and pullout strength test. Bone cylinders were prepared from porcine bone and separated into 2 groups: cylinders removed from femur head (high density bone - HDB), and cylinders removed from mandibular condyle (low density bone - LDB). The bone cylinders were previously certificated to guarantee intra-groups standardization and between groups discrimination. Then, 3D analysis evaluated the following tomographic parameters of bone cylinders: Tridimensional bone density (BV/TV), Trabecular Separation (Tb.Sp); Percentage of closed pores (POcl); Percentage of open pores (POop); Percentage of total porosity (POtot). These parameters were evaluated in 3 bone levels (L1 - bone volume internal to the threads; L2 - immediately adjacent to the end of threads until 0.5 mm; L3 - 0.5 mm to 1.5 mm distant to the end of threads). Twenty implants (TitaniumFix®) from two different models were divided in 4 groups (5 implants each): Group 1 (G1) - e-Fix HE implant placed in HDB cylinder; Group 2 (G2) - e-Fix HE implant placed in LDB cylinder; Group 3 (G3) - e-Fix HE Silver implant placed in HDB cylinder; Group 4 (G4) - e-Fix HE Silver implant placed in LDB cylinder. During implant placement the insertion torque was recorded. Following implant installation, bone cylinders were evaluated by micro-CT, as previously described. After that, pullout strength test was performed. The results of 3D analysis showed pre- and post-implants intra-groups statistically significant differences for G3 and G4, in all evaluation levels and for all tomographic parameters. The analysis of L3 showed a significant decrease from pre to post-implant situation in BV/TV and PO.op for G1, G3 and G4. Group 3 showed the higher values for insertion torque and pullout strength test (for all analysis, Friedman Test, p<0.05). It was concluded that this methodology can produce standardized bone cylinders of high and low bone density, e-Fix Silver implants showed better results in biomechanical assays, and different implant designs can promote diverse effects, modifying the bone structure .
5

Avaliação da estabilidade primária de dois tipos de implantes instalados em modelos ósseos suínos padronizados, utilizando ensaios biomecânicos e micro-CT. Estudo piloto in vitro / Evaluation of primary stability of two types of implants installed in standardized porcine bone models, using biomechanical tests and Micro- CT in vitro study

Dantas, Carolina Delmondes Freitas 31 May 2012 (has links)
Estabilidade primária adequada em densidades ósseas de resistências variadas é um dos fatores importantes para o sucesso da osseointegração. O objetivo deste estudo foi avaliar comparativamente a estabilidade inicial de diferentes tipos de implantes, utilizando cilindros ósseos padronizados de origem suína, de alta e baixa densidades, em modelo in vitro, por meio de Análises Tri-dimensionais (microtomografia computadorizada); Torque de Inserção e Ensaio de Arrancamento. Os cilindros ósseos foram preparados a partir de osso suíno, retirados do côndilo mandibular ou da cabeça do fêmur, e separados em 2 grupos: Grupo A: cilindros removidos da cabeça do fêmur (alta densidade óssea), e Grupo B: cilindros removidos do côndilo mandibular (baixa densidade óssea). Previamente aos procedimentos experimentais os cilindros ósseos foram certificados por meio de análises de imagens 2D e 3D, para garantir a uniformidade intra-grupos e distinção entre-grupos dos espécimes. Após a certificação, foram feitas microtomografias computadorizadas dos cilindros ósseos, para análise tridimensional de imagens prévia à instalação dos implantes, avaliando os seguintes parâmetros: Densidade Óssea Tridimensional (DOT); Separação Trabecular (STB); Porcentagem de Poros Abertos (PPA); Porcentagem de Poros Fechados (PPF) e Porcentagem de Porosidade Total (PPT). Esses parâmetros foram avaliados em três níveis ósseos (N1 interno às roscas do implante a ser instalado; N2 adjacente ao final das roscas até 0,5 mm destas; N distante 0,5 mm a 1,5 mm do final das roscas). Depois disso, foram selecionados 20 implantes (Titaniumfix®) de dois modelos, divididos em 4 grupos, cada um com 05 implantes: Grupo 1 (G1): Implante e-Fix HE instalado em cilindro ósseo de alta densidade; Grupo 2 (G2): Implante e-Fix HE instalado em cilindro ósseo de baixa densidade; Grupo 3 (G3): Implante e-Fix HE Silver instalado em cilindro ósseo de alta densidade; Grupo 4 (G4) : Implante e-Fix HE Silver instalado em cilindro ósseo de baixa densidade. A instalação dos implantes seguiu o protocolo recomendado pelo fabricante, e durante o procedimento foi feita a medida do torque de inserção. Após a instalação dos implantes, todos os cilindros ósseos foram submetidos a nova análise tridimensional com os mesmos parâmetros e níveis ósseos previamente descritos, e ao ensaio de arrancamento. Os resultados das análises tridimensionais mostraram diferenças estatisticamente significantes intra grupos nas situações pré- e pós-implantes para G3 e G4, em todos os níveis e para todos os parâmetros tomográficos. Observou-se também no Nível 2 diferenças estatisticamente significantes intra grupos para todos os grupos e todos os parâmetros. No nível 3, foi observado um comprometimento nos valores dos parâmetros DOT e PPA, eststisticamente significante para G1, G3 e G4, e numericamente pronunciado no G2 (Teste de Friedman, p<0,05). Os ensaios biomecânicos mostraram que os implantes instalados no G3 (e-Fix HE Silver) tiveram maior torque de inserção e maior resistência ao arrancamento quando comparados ao mesmo tipo de implante instalado no G4 e aos implantes do modelo e-fix HE instalados no G2 (teste de Friedman, p<0,05). Concluiu-se que a metodologia apresentada gera cilindros ósseos padronizados de alta e baixa densidades, o formato dos implantes e-Fix Silver mostrou melhores resultados nos testes biomecânicos e a densidade óssea radiográfica e tomográfica correlacionou-se à estabilidade primária. / This study comparatively evaluated the primary stability of two different implants, placed in standardized porcine bone cylinders of high and low density, analyzing 3D images (computerized micro tomography - micro-CT), insertion torque and pullout strength test. Bone cylinders were prepared from porcine bone and separated into 2 groups: cylinders removed from femur head (high density bone - HDB), and cylinders removed from mandibular condyle (low density bone - LDB). The bone cylinders were previously certificated to guarantee intra-groups standardization and between groups discrimination. Then, 3D analysis evaluated the following tomographic parameters of bone cylinders: Tridimensional bone density (BV/TV), Trabecular Separation (Tb.Sp); Percentage of closed pores (POcl); Percentage of open pores (POop); Percentage of total porosity (POtot). These parameters were evaluated in 3 bone levels (L1 - bone volume internal to the threads; L2 - immediately adjacent to the end of threads until 0.5 mm; L3 - 0.5 mm to 1.5 mm distant to the end of threads). Twenty implants (TitaniumFix®) from two different models were divided in 4 groups (5 implants each): Group 1 (G1) - e-Fix HE implant placed in HDB cylinder; Group 2 (G2) - e-Fix HE implant placed in LDB cylinder; Group 3 (G3) - e-Fix HE Silver implant placed in HDB cylinder; Group 4 (G4) - e-Fix HE Silver implant placed in LDB cylinder. During implant placement the insertion torque was recorded. Following implant installation, bone cylinders were evaluated by micro-CT, as previously described. After that, pullout strength test was performed. The results of 3D analysis showed pre- and post-implants intra-groups statistically significant differences for G3 and G4, in all evaluation levels and for all tomographic parameters. The analysis of L3 showed a significant decrease from pre to post-implant situation in BV/TV and PO.op for G1, G3 and G4. Group 3 showed the higher values for insertion torque and pullout strength test (for all analysis, Friedman Test, p<0.05). It was concluded that this methodology can produce standardized bone cylinders of high and low bone density, e-Fix Silver implants showed better results in biomechanical assays, and different implant designs can promote diverse effects, modifying the bone structure .
6

Avaliação da estabilidade primária de implantes convencionais e modificados por meio de ensaios de desempenho, frequência de ressonância e análise microestrutural / Evaluation of primary stability of conventional and modified implants by the performance tests, resonance frequency and microstructural analysis

Mariana Lima da Costa Valente 09 October 2014 (has links)
A estabilidade primária dos implantes odontológicos é determinante para a osseointegração e depende dos fatores qualidade, quantidade óssea e tipo de implante. O objetivo desse estudo foi avaliar a influência do formato de implantes convencionais e modificados e do tipo de substrato na estabilidade primária por meio da correlação de ensaios de desempenho e frequência de ressonância e análise microestrutural. No estudo foram utilizados 54 implantes Neodent®: 27 cilíndricos, sendo 9 hexágono externo (Titamax Ti Cortical - 4,0 mm x 11 mm), 9 hexágono interno (Titamax II Plus - 3,75 mm x 11 mm) e 9 cone morse (Titamax CM - 4,0 mm x 11 mm); e 27 implantes cônicos de 4,3 mm x 10 mm, sendo 9 hexágono externo (Alvim Ti), 9 hexágono interno (Alvim II Plus) e 9 cone morse (Alvim CM). Os implantes foram inseridos em osso artificial da marca Nacional® nas densidades de 15, 20 e 40 PCF e osso de costela suína. Para os ensaios de desempenho foi quantificado o torque de inserção com um torquímetro digital e a força máxima de arrancamento utilizando uma Máquina Universal de Ensaios. Para avaliar a frequência de ressonância foi utilizado o aparelho Ostell® e para a análise morfológica um Microscópio Eletrônico de Varredura, sob aumentos de 40 e 100 vezes. Após a realização dos ensaios com os implantes convencionais, os modelos Alvim CM e Titamax Ti Cortical (n=9) tiveram sua morfologia externa alterada com a prolongação dos chanfros desde o terço apical até o nível da plataforma protética e foram submetidos aos mesmos testes propostos para os parafusos originais. Verificada a normalidade dos dados utilizou-se o teste de análise de variância ANOVA, comparação de médias Tukey (&alpha;=5%) e correlação de Pearson. Para os implantes convencionais, o Alvim CM apresentou maior média em todos os ensaios realizados, sendo estatisticamente diferente dos implantes cilíndricos quando analisado o torque de inserção no osso (73,33 N.cm) e força de arrancamento na poliuretana de 40 PCF (910,36 N) e osso (553,79 N). Os implantes Titamax II Plus tiveram as menores médias, diferente estatisticamente dos cônicos quando analisado o torque de inserção (22,22 N.cm) e frequência de ressonância no osso (72,83 ISQ) e força de arrancamento na poliuretana de 40 PCF (61,97 N) e osso (86,40 N). A análise dos ensaios de desempenho e frequência de ressonância apresentou correlação moderada de acordo com o p de Pearson (0,30 a 0,70) e a comparação entre as fotomicrografias não mostrou alteração morfológica dos implantes. A modificação realizada no parafuso Alvim CM proporcionou um aumento significativo no torque de inserção (p=0,000), diminuição das médias de arrancamento (p=0,000) e manteve semelhança com as médias de frequência de ressonância (p=0,169) quando comparado ao implante convencional. O Titamax Ti modificado aumentou significativamente o torque de inserção (p=0,043) e provocou diminuição significativa para a frequência de ressonância (p=0,002) e ensaio de arrancamento (p=0,000). Conclui-se que o formato dos implantes interfere na estabilidade primária, sendo os implantes cônicos indutores de maior estabilidade. A análise de correlação das metodologias empregadas demonstrou a associação positiva das mesmas para complementação da análise da estabilidade primária / The primary stability of dental implants is critical for osseointegration and depends on factors quality, bone quantity and type of implant. The aim of this study was to evaluate the influence of conventional and modified implants and the type of substrate shape on primary stability through the correlation of performance tests and frequency of resonance and microstructural analysis. In the study 54 Neodent® implants were used: 27 cylindrical, 9 hexagonal (Titamax Ti Cortical - 4.0 mm x 11 mm), 9 internal hexagon (Titamax II Plus - 3.75 mm x 11 mm) and 9 morse taper (Titamax CM - 4.0 mm x 11 mm); and 27 tapered implants of 4.3 mm x 10 mm and 9 external hexagon (Alvim Ti), 9 internal hexagon (Alvim II Plus) and 9 morse taper (Alvim CM). The implants were inserted into artificial bone of National ® brand at densities of 15, 20 and 40 PCF and pork rib bone. For testing the performance was quantified insertion torque with a digital torque meter and the maximum pullout strength using a universal testing machine. To evaluate the resonance frequency was used Ostell ® device and the morphological parsing an Scanning Electron Microscope under increases of 40 and 100 times. After the tests with conventional implants, models CM Alvim and Titamax Cortical Ti (n=9) had their external morphology changed with the prolongation of the bevels from the apical to the level of prosthetic platform and underwent the same tests proposed for the original screws. Checked for normality of the data used in the test of ANOVA, Tukey comparison (&alpha;=5%) and Pearson correlation. For conventional implants, the CM Alvim showed higher average in all tests, with statistically different when analyzed cylindrical implant insertion torque on bone (73.33 N.cm) and pullout strength in polyurethane 40 PCF (910.36 N) and bone (553.79 N). Implants Titamax II Plus had the lowest average, statistically different when analyzed the tapered insertion torque (22.22 N.cm) and resonance frequency in bone (72.83 ISQ) and pullout strength in 40 PCF polyurethane (61.97 N) and bone (86.40 N). The analysis of the performance tests and had moderate resonance frequency correlation according op Pearson (0.30 to 0.70) and comparing the photomicrographs showed no morphological alteration of the implants. The modification made to the screw Alvim CM provided a significant increase in insertion torque (p=0.000), decrease of average pullout (p=0.000) and remained similar to the average resonance frequency (p=0.169) when compared to the implant conventional. The Titamax Ti modified significantly increased insertion torque (p=0.043) and caused a significant decrease in the resonance frequency (p=0.002) and pullout test (p=0.000). It is concluded that the shape of the implants interfere with the primary stability, with the inductors tapered implants stability. Correlation analysis of the methodologies used showed a possible association of these for further analysis of primary stability
7

Avaliação da resistência ao arrancamento e do torque de remoção de um novo modelo de implante de zircônia / Analysis of pullout strength and removal torque of a new zirconia dental implants

Renata Espindola Silveira 15 January 2015 (has links)
O objetivo deste estudo foi avaliar comparativamente a estabilidade primária e a longevidade de implantes de zircônia (Y-TZP) e titânio (Grau IV) após ciclagem termomecânica (CTM). Foram obtidos 40 implantes de cada material que foram instalados em osso artificial e separados em grupos (n=10) segundo o material, a realização de ciclagem termomecânica e o ensaio realizado: Titânio - G1 (ensaio de torque de remoção); G2 (ensaio de arrancamento); G3 (CTM + ensaio de torque de remoção); G4 (CFTM + ensaio de arrancamento); e Zircônia - G5 (ensaio de torque de remoção); G6 (ensaio de arrancamento); G7 (CTM + ensaio de torque de remoção); G8 (CTM + ensaio de arrancamento). O equipamento de ciclagem mecânica foi configurado com carga de 133 N, frequência de 120 ciclos por minuto (2 Hz), totalizando 2.000.000 ciclos em cada espécime. A ciclagem térmica foi realizada com temperatura entre 5ºC, 37ºC e 55ºC. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (2-way ANOVA, teste de Bonferroni, p<0,05) e verificou-se que houve diferença estatisticamente significante (p<0,05) entre os implantes de titânio e zircônia, independente do tratamento utilizado, tanto para o torque de remoção quanto para a foça máxima de arrancamento. Os implantes de titânio mostraram maiores valores de torque de remoção e força de arrancamento comparado aos implantes de zircônia (p<0,05). Verificou-se também que a ciclagem termomecânica foi significante apenas para o ensaio de arrancamento quando utilizados implantes de titânio. Conclui-se que a estabilidade primária de implantes de titânio foi maior do que implantes de zircônia e que a ciclagem termomecânica foi um fator significativo apenas para a longevidade dos implantes de titânio. / The aim of this study was to assess comparatively the primary stability and longevity of zirconia (Y-TZP) and titanium (Grade IV) implants after thermomechanical cyclic (CTF). Forty implants to each material were obtained, installed in artificial bone and separated into groups (n=10) according to the material, the conducting of thermomechanical cyclic and the test submitted: Titanium - G1 (removal torque); G2 (pullout test); G3 (CTF + removal torque); G4 (TCF + pullout test); Zirconia - G5 (removal torque); G6 (pullout test); G7 (CTF + removal torque); G8 (CTF + pullout test). The mechanical cyclic testing machine was programmed to apply a load of 133 N, frequency of 120 cycles per minute (2 Hz) and a total of 2,000,000 cycles in each specimen. The thermocycling was set with a temperature between 5°C, 37ºC and 55ºC. After the mechanical tests, the data were subjected to statistical analysis (2-way ANOVA, Bonferroni test, p <0,05) and the results showed statistically significant difference (p <0.05) between zirconia and titanium implants, regardless of treatment used, for both removal torque and pullout tests. Titanium implants showed higher removal torque and pullout strength, which was statistically significant (p <0,05) compared with zirconia implants. It was also found that the thermomechanical cyclic was only significant for pullout test when used titanium implants. It was concluded that primary stability of titanium implants is higher than zirconia implants and the thermomechanical cyclic was a significant factor only for the longevity of titanium implants.
8

Efeito de diferentes tempos de ativação sobre a estabilidade e resposta óssea ao redor de implantes dentários. Estudo por análise de freqüência de ressonância e histomorfométrico em cães / Effect of different loading time on the stabililty and boné response around dental implants. Resonance frequency analysis and histomorphometric study in dogs.

Jayme, Sérgio Jorge 16 April 2009 (has links)
Propósito: O objetivo deste estudo foi avaliar a estabilidade primária com análise de freqüência de ressonância e a resposta óssea por histomorfometria em implantes sob tratamento com carga imediata e carga precoce. Material e método: Foram colocados três implantes Replace Select (Nobel Biocare, Suécia) em cada lado da mandíbula de 8 cães, totalizando 48 implantes no estudo. Um par de implantes foi selecionado para o protocolo de carga imediata (CI). Após sete dias, o segundo par de implantes recebeu as próteses para o protocolo de carga precoce (CP). Catorze dias após a colocação dos implantes, o terceiro par de implantes recebeu as próteses para o protocolo de carga precoce tardia (CPT). Em cada período foi medida a estabilidade dos implantes por freqüência de ressonância. Após o período total de doze semanas da colocação das próteses os animais foram sacrificados e os espécimes foram preparados para análise histomorfométrica. As diferenças entre os tempos de carregamento para os seguintes parâmetros: estabilidade, contato ossoimplante (COI), densidade óssea (DO) e perda da crista óssea (PCO) foram avaliadas usando ANOVA. Resultados: Os valores iniciais de estabilidade (ISQ) dos implantes foram: 77,88 ± 4,61 para CI, 79,73 ± 3,55 para CP e 79,64 ± 3,00 para CPT, sem diferença estatisticamente significante (p=0,30). Os valores finais de estabilidade foram 80,46 ± 4,23 para CI, 81,88 ± 3,55 para CP e 81,88 ± 3,42 para CPT, também sem diferença estatística (p=0,47). Para avaliar a estabilidade dos implantes em função do tempo, foi realizada ANOVA para amostras repetidas e para cada grupo foi detectado aumento significativo da estabilidade ao final do experimento (p=0,003). A interação método de carregamento versus tempo não foi significativa (p=0,97). A porcentagem de COI para CI foi 77,9 ± 1,71%, para CP foi 79,25 ± 2,11% e para CPT foi 79,42 ± 1,49%. A porcentagem de DO para CI foi 69,97 ± 3,81%, para CP foi 69,23 ± 5,68% e para CPT foi 69,19 ± 2,90%. A PCO para CI foi 1,57 ± 0,22 mm, para CP foi 1,23 ± 0,19 mm e para CPT foi 1,17 ± 0,32 mm. Não foi observada diferença estatística para nenhum dos parâmetros avaliados (p>0,05). Conclusão: Considerando a estabilidade primária, contato osso-implante, densidade óssea ao redor do implante e perda da crista óssea em cães, conclui-se que não existem diferenças estatisticamente significantes num prazo de até 12 semanas para implantes submetidos à ativação imediata, em 7 dias ou 14 dias após a cirurgia. / Purpose: The aim of this study was to evaluate the implant stability through frequency resonance analysis and the effect that different loading time will have on the bone response around implants through a histomorphometric analysis. Material and Methods: Three Replace Select implants were placed on each side of the mandible in 8 dogs totaling 48 implants in the study. One pair of implants was selected for immediate loading protocol (IL). After seven days the second pair of implants received the prostheses for the early loading protocol (EL). In each period, the implant stability measurements were performed by means of resonance frequency. After 12 weeks, a new reading of the implant stability was performed. Fourteen days after the implant placement the third pair of implants received the prostheses for the advanced early loading (AEL). Following a period totaling twelve weeks of prosthetics, the animals were sacrificed and the specimens were prepared for histomorphometric analysis. The differences between loading time in the following parameters: bone-to-implant contact (BIC), bone density (BD) and crestal bone loss (CBL) were evaluated through ANOVA. Results: The mean values of initial stability (ISQ) in different loading times were 77.88 ± 4.61 (IL), 79.73 ± 3.55 (EL) and 79.64 ± 3.00 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.30). The mean values of final stability in different loading times were 80.46 ± 4.23 (IL), 81.88 ± 3.55 (EL) and 81.88 ± 3.42 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.47). To evaluate the implant stability in function of time, a variance analysis for repeated samples was performed, and there was significant difference (p = 0.003), indicating, for each group, a significant increase in stability at the end of the experiment. The time versus method interaction did not show significant difference (p = 0.97), indicating that the variations are similar in the studied groups. The percentage of BIC for IL was 77.9 ± 1.71%, for EL was 79.25 ± 2.11% and for AEL was 79.42 ± 1.49%. The percentage of BD for IL was 69.97 ± 3.81%, for EL was 69.23 ± 5.68% and for AEL was 69.19 ± 2.90%. The CBL for IL was 1.57 ± 0.22mm, for EL was 1.23 ± 0.19mm and for AEL was 1.17 ± 0.32mm. There was no statistical difference for any of the parameters evaluated (p>0.05). Conclusion: Considering primary stability, bone-to-implant contact, bone density around the implants and crestal bone loss, there are no significant differences until 12 weeks after surgery for the stability of immediate, 7 or 14 days after placement activated implants.
9

Avaliação da resistência ao arrancamento e do torque de remoção de um novo modelo de implante de zircônia / Analysis of pullout strength and removal torque of a new zirconia dental implants

Silveira, Renata Espindola 15 January 2015 (has links)
O objetivo deste estudo foi avaliar comparativamente a estabilidade primária e a longevidade de implantes de zircônia (Y-TZP) e titânio (Grau IV) após ciclagem termomecânica (CTM). Foram obtidos 40 implantes de cada material que foram instalados em osso artificial e separados em grupos (n=10) segundo o material, a realização de ciclagem termomecânica e o ensaio realizado: Titânio - G1 (ensaio de torque de remoção); G2 (ensaio de arrancamento); G3 (CTM + ensaio de torque de remoção); G4 (CFTM + ensaio de arrancamento); e Zircônia - G5 (ensaio de torque de remoção); G6 (ensaio de arrancamento); G7 (CTM + ensaio de torque de remoção); G8 (CTM + ensaio de arrancamento). O equipamento de ciclagem mecânica foi configurado com carga de 133 N, frequência de 120 ciclos por minuto (2 Hz), totalizando 2.000.000 ciclos em cada espécime. A ciclagem térmica foi realizada com temperatura entre 5ºC, 37ºC e 55ºC. Após os ensaios mecânicos, os resultados foram submetidos à análise estatística (2-way ANOVA, teste de Bonferroni, p<0,05) e verificou-se que houve diferença estatisticamente significante (p<0,05) entre os implantes de titânio e zircônia, independente do tratamento utilizado, tanto para o torque de remoção quanto para a foça máxima de arrancamento. Os implantes de titânio mostraram maiores valores de torque de remoção e força de arrancamento comparado aos implantes de zircônia (p<0,05). Verificou-se também que a ciclagem termomecânica foi significante apenas para o ensaio de arrancamento quando utilizados implantes de titânio. Conclui-se que a estabilidade primária de implantes de titânio foi maior do que implantes de zircônia e que a ciclagem termomecânica foi um fator significativo apenas para a longevidade dos implantes de titânio. / The aim of this study was to assess comparatively the primary stability and longevity of zirconia (Y-TZP) and titanium (Grade IV) implants after thermomechanical cyclic (CTF). Forty implants to each material were obtained, installed in artificial bone and separated into groups (n=10) according to the material, the conducting of thermomechanical cyclic and the test submitted: Titanium - G1 (removal torque); G2 (pullout test); G3 (CTF + removal torque); G4 (TCF + pullout test); Zirconia - G5 (removal torque); G6 (pullout test); G7 (CTF + removal torque); G8 (CTF + pullout test). The mechanical cyclic testing machine was programmed to apply a load of 133 N, frequency of 120 cycles per minute (2 Hz) and a total of 2,000,000 cycles in each specimen. The thermocycling was set with a temperature between 5°C, 37ºC and 55ºC. After the mechanical tests, the data were subjected to statistical analysis (2-way ANOVA, Bonferroni test, p <0,05) and the results showed statistically significant difference (p <0.05) between zirconia and titanium implants, regardless of treatment used, for both removal torque and pullout tests. Titanium implants showed higher removal torque and pullout strength, which was statistically significant (p <0,05) compared with zirconia implants. It was also found that the thermomechanical cyclic was only significant for pullout test when used titanium implants. It was concluded that primary stability of titanium implants is higher than zirconia implants and the thermomechanical cyclic was a significant factor only for the longevity of titanium implants.
10

Efeito de diferentes tempos de ativação sobre a estabilidade e resposta óssea ao redor de implantes dentários. Estudo por análise de freqüência de ressonância e histomorfométrico em cães / Effect of different loading time on the stabililty and boné response around dental implants. Resonance frequency analysis and histomorphometric study in dogs.

Sérgio Jorge Jayme 16 April 2009 (has links)
Propósito: O objetivo deste estudo foi avaliar a estabilidade primária com análise de freqüência de ressonância e a resposta óssea por histomorfometria em implantes sob tratamento com carga imediata e carga precoce. Material e método: Foram colocados três implantes Replace Select (Nobel Biocare, Suécia) em cada lado da mandíbula de 8 cães, totalizando 48 implantes no estudo. Um par de implantes foi selecionado para o protocolo de carga imediata (CI). Após sete dias, o segundo par de implantes recebeu as próteses para o protocolo de carga precoce (CP). Catorze dias após a colocação dos implantes, o terceiro par de implantes recebeu as próteses para o protocolo de carga precoce tardia (CPT). Em cada período foi medida a estabilidade dos implantes por freqüência de ressonância. Após o período total de doze semanas da colocação das próteses os animais foram sacrificados e os espécimes foram preparados para análise histomorfométrica. As diferenças entre os tempos de carregamento para os seguintes parâmetros: estabilidade, contato ossoimplante (COI), densidade óssea (DO) e perda da crista óssea (PCO) foram avaliadas usando ANOVA. Resultados: Os valores iniciais de estabilidade (ISQ) dos implantes foram: 77,88 ± 4,61 para CI, 79,73 ± 3,55 para CP e 79,64 ± 3,00 para CPT, sem diferença estatisticamente significante (p=0,30). Os valores finais de estabilidade foram 80,46 ± 4,23 para CI, 81,88 ± 3,55 para CP e 81,88 ± 3,42 para CPT, também sem diferença estatística (p=0,47). Para avaliar a estabilidade dos implantes em função do tempo, foi realizada ANOVA para amostras repetidas e para cada grupo foi detectado aumento significativo da estabilidade ao final do experimento (p=0,003). A interação método de carregamento versus tempo não foi significativa (p=0,97). A porcentagem de COI para CI foi 77,9 ± 1,71%, para CP foi 79,25 ± 2,11% e para CPT foi 79,42 ± 1,49%. A porcentagem de DO para CI foi 69,97 ± 3,81%, para CP foi 69,23 ± 5,68% e para CPT foi 69,19 ± 2,90%. A PCO para CI foi 1,57 ± 0,22 mm, para CP foi 1,23 ± 0,19 mm e para CPT foi 1,17 ± 0,32 mm. Não foi observada diferença estatística para nenhum dos parâmetros avaliados (p>0,05). Conclusão: Considerando a estabilidade primária, contato osso-implante, densidade óssea ao redor do implante e perda da crista óssea em cães, conclui-se que não existem diferenças estatisticamente significantes num prazo de até 12 semanas para implantes submetidos à ativação imediata, em 7 dias ou 14 dias após a cirurgia. / Purpose: The aim of this study was to evaluate the implant stability through frequency resonance analysis and the effect that different loading time will have on the bone response around implants through a histomorphometric analysis. Material and Methods: Three Replace Select implants were placed on each side of the mandible in 8 dogs totaling 48 implants in the study. One pair of implants was selected for immediate loading protocol (IL). After seven days the second pair of implants received the prostheses for the early loading protocol (EL). In each period, the implant stability measurements were performed by means of resonance frequency. After 12 weeks, a new reading of the implant stability was performed. Fourteen days after the implant placement the third pair of implants received the prostheses for the advanced early loading (AEL). Following a period totaling twelve weeks of prosthetics, the animals were sacrificed and the specimens were prepared for histomorphometric analysis. The differences between loading time in the following parameters: bone-to-implant contact (BIC), bone density (BD) and crestal bone loss (CBL) were evaluated through ANOVA. Results: The mean values of initial stability (ISQ) in different loading times were 77.88 ± 4.61 (IL), 79.73 ± 3.55 (EL) and 79.64 ± 3.00 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.30). The mean values of final stability in different loading times were 80.46 ± 4.23 (IL), 81.88 ± 3.55 (EL) and 81.88 ± 3.42 (AEL). The data were subject to ANOVA and a significant difference was not detected (p = 0.47). To evaluate the implant stability in function of time, a variance analysis for repeated samples was performed, and there was significant difference (p = 0.003), indicating, for each group, a significant increase in stability at the end of the experiment. The time versus method interaction did not show significant difference (p = 0.97), indicating that the variations are similar in the studied groups. The percentage of BIC for IL was 77.9 ± 1.71%, for EL was 79.25 ± 2.11% and for AEL was 79.42 ± 1.49%. The percentage of BD for IL was 69.97 ± 3.81%, for EL was 69.23 ± 5.68% and for AEL was 69.19 ± 2.90%. The CBL for IL was 1.57 ± 0.22mm, for EL was 1.23 ± 0.19mm and for AEL was 1.17 ± 0.32mm. There was no statistical difference for any of the parameters evaluated (p>0.05). Conclusion: Considering primary stability, bone-to-implant contact, bone density around the implants and crestal bone loss, there are no significant differences until 12 weeks after surgery for the stability of immediate, 7 or 14 days after placement activated implants.