Measurement of the efficiency of evacuated tube solar collectors under various operating conditions

Zubriski, Stephanie Erin 10 September 2010 (has links)
The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. The scope of the research project was limited to the efficiency of a single tube, and various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% in general between the different collector configurations.
2

Measurement of the efficiency of evacuated tube solar collectors under various operating conditions

Zubriski, Stephanie Erin 10 September 2010 (has links)
The purpose of this research program was to measure the efficiency of evacuated tube solar collectors under various operating conditions including: the angle of inclination towards the incident solar radiation, heat transfer fluid flow rate, glazing installation, and number of evacuated tubes. The operating conditions and configurations were chosen to represent realistic or probable installation scenarios and environmental conditions. Furthermore, the research aimed to identify the suitability of evacuated tube solar collectors to each of the scenarios. The scope of the research project was limited to the efficiency of a single tube, and various configurations of a 32-tube panel, not the entire solar domestic hot water or space heating system. Thus, factors such as heat loss in the tubing, solar storage tank, and heat exchanger efficiency were not investigated. The findings indicated that efficiency varied by approximately 5% in general between the different collector configurations.
3

Computer Model Verification and Testing of an Apricus AP-30 Evacuated Tube Collector Array

January 2011 (has links)
abstract: Evacuated tube solar thermal collector arrays have a wide range of applications. While most of these applications are limited in performance due to relatively low maximum operating temperatures, these collectors can still be useful in low grade thermal systems. An array of fifteen Apricus AP-30 evacuated tube collectors was designed, assembled, and tested on the Arizona State University campus in Tempe, AZ. An existing system model was reprogrammed and updated for increased flexibility and ease of use. The model predicts the outlet temperature of the collector array based on the specified environmental conditions. The model was verified through a comparative analysis to the data collected during a three-month test period. The accuracy of this model was then compared against data calculated from the Solar Rating and Certification Corporation (SRCC) efficiency curve to determine the relative performance. It was found that both the original and updated models were able to generate reasonable predictions of the performance of the collector array with overall average percentage errors of 1.0% and 1.8%, respectively. / Dissertation/Thesis / M.S. Mechanical Engineering 2011
4

Desenvolvimento de uma bancada para ensaios de coletores solares de tubos de vidro a vácuo

Manea, Tiago Francisco January 2012 (has links)
Sistemas de aquecimento de água que utilizam a conversão de energia solar em energia térmica, além de serem um meio fácil e limpo de geração de energia, trazem benefícios econômicos ao país e principalmente a quem os utiliza. O elemento principal destes sistemas, o coletor solar, é objeto de estudo neste trabalho. Coletores planos são amplamente utilizados e possuem uma tecnologia consolidada, porém, um tipo de coletor composto por tubos de vidro, com isolamento a vácuo e superfície absorvedora seletiva vem se tornando uma opção cada vez mais viável economicamente. Com benefícios evidentes em climas de frio mais intenso, estes coletores devem ter seus parâmetros de desempenho térmico determinados segundo procedimentos normativos, para que possam ser dimensionados de forma correta os sistemas de aquecimento que os utilizarem. Este trabalho descreve o desenvolvimento de uma bancada de ensaios construída no Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul, que tem o intuito de possibilitar o ensaio deste tipo de coletor. Esta bancada contou com uma instrumentação cuidadosamente calibrada e com um dispositivo, desenvolvido neste trabalho, capaz de realizar medidas da diferença de temperatura da água entre as seções de entrada e saída do coletor com uma incerteza inferior a 0,05 °C. Foram realizados ensaios individuais de dois tubos a vácuo de superfícies absorvedoras distintas desacoplados do coletor. Um ensaio determinou seu coeficiente de transferência de calor e outro avaliou as propriedades ópticas de cada tubo. A metodologia experimental utilizada se mostrou válida e possível de determinar alguns parâmetros para utilização em simulações. Um melhor desempenho do tubo com superfície seletiva de (Al-N/SS/Cu) em relação ao que utiliza (Al-N/Al) ficou evidente nestes ensaios. Foi realizado na bancada desenvolvida o ensaio de um coletor de tubos de vidro a vácuo que utiliza o principio de transferência direta. Sua curva de eficiência e seus parâmetros de desempenho foram determinados sob condições de regime permanente. Houve pequena diferença entre os valores obtidos e os fornecidos pelo fabricante, o que deve ter ocorrido, em parte, devido à diferença das condições de realização dos ensaios. A curva de desempenho obtida neste trabalho para o coletor de tubos de vidro a vácuo foi comparada às curvas de dois coletores planos. Nesta comparação ficou evidente que o coletor ensaiado é mais eficiente em situações onde a diferença entre a temperatura da água no interior do coletor e temperatura ambiente são maiores. / The use of solar systems for heating water brings economic benefits to the country and especially to the users. Furthermore, it is an easy and clean form of energy generation. The solar collector, the main element of such systems, is the object of the present study. Flat plane collectors are widely used and have a consolidated technology. However, the market share of tubular evacuated glass collectors is rapidly increasing. These collectors are constituted by elements consisting in two concentrical tubes with vacuum in between. Instead of using a black painted sheet of metal as the absorbing element, the internal glass tube is coated with a selective surface. The vacuum provides a high level insulation, with evident benefits in severe cold climates. In order to allow a correct sizing of systems employing such collectors, their thermal performance parameters must be determined according to standard procedures. This work show the description of a test system, built at Laboratório de Energia Solar of Universidade do Rio Grande do Sul, which enable the testing of this type of collector. This test system features a carefully calibrated instrumentation and a device, developed in this work, for measuring the water temperature difference between the collector inlet and outlet with an accuracy of 0.05 °C. A test for estimating the thermal losses and the optical properties of two evacuated tubes with different selective surfaces (Al-N/SS/Cu e Al-N/Al) was also performed. The better performance of the tube with the selective surface deposited on a copper layer was. The experimental methodology was proven to be valid and useful for determining some parameters used in simulations. A test based on the current Brazilian standard with a solar collector with twenty water-in-glass vacuum tubes was performed. Its efficiency curve and its performance parameters were determined under steady state conditions. Some differences between the obtained values and manufacturer data were detected, probably due to the difference between the test conditions. The efficiency curve obtained for the tubular solar collector was compared to the curves of two flat plane collectors. This comparison indicated that the tested collector is more efficient under situations in which the difference between the temperature of the water inside the collector and the ambient temperature are higher.
5

Desenvolvimento de uma bancada para ensaios de coletores solares de tubos de vidro a vácuo

Manea, Tiago Francisco January 2012 (has links)
Sistemas de aquecimento de água que utilizam a conversão de energia solar em energia térmica, além de serem um meio fácil e limpo de geração de energia, trazem benefícios econômicos ao país e principalmente a quem os utiliza. O elemento principal destes sistemas, o coletor solar, é objeto de estudo neste trabalho. Coletores planos são amplamente utilizados e possuem uma tecnologia consolidada, porém, um tipo de coletor composto por tubos de vidro, com isolamento a vácuo e superfície absorvedora seletiva vem se tornando uma opção cada vez mais viável economicamente. Com benefícios evidentes em climas de frio mais intenso, estes coletores devem ter seus parâmetros de desempenho térmico determinados segundo procedimentos normativos, para que possam ser dimensionados de forma correta os sistemas de aquecimento que os utilizarem. Este trabalho descreve o desenvolvimento de uma bancada de ensaios construída no Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul, que tem o intuito de possibilitar o ensaio deste tipo de coletor. Esta bancada contou com uma instrumentação cuidadosamente calibrada e com um dispositivo, desenvolvido neste trabalho, capaz de realizar medidas da diferença de temperatura da água entre as seções de entrada e saída do coletor com uma incerteza inferior a 0,05 °C. Foram realizados ensaios individuais de dois tubos a vácuo de superfícies absorvedoras distintas desacoplados do coletor. Um ensaio determinou seu coeficiente de transferência de calor e outro avaliou as propriedades ópticas de cada tubo. A metodologia experimental utilizada se mostrou válida e possível de determinar alguns parâmetros para utilização em simulações. Um melhor desempenho do tubo com superfície seletiva de (Al-N/SS/Cu) em relação ao que utiliza (Al-N/Al) ficou evidente nestes ensaios. Foi realizado na bancada desenvolvida o ensaio de um coletor de tubos de vidro a vácuo que utiliza o principio de transferência direta. Sua curva de eficiência e seus parâmetros de desempenho foram determinados sob condições de regime permanente. Houve pequena diferença entre os valores obtidos e os fornecidos pelo fabricante, o que deve ter ocorrido, em parte, devido à diferença das condições de realização dos ensaios. A curva de desempenho obtida neste trabalho para o coletor de tubos de vidro a vácuo foi comparada às curvas de dois coletores planos. Nesta comparação ficou evidente que o coletor ensaiado é mais eficiente em situações onde a diferença entre a temperatura da água no interior do coletor e temperatura ambiente são maiores. / The use of solar systems for heating water brings economic benefits to the country and especially to the users. Furthermore, it is an easy and clean form of energy generation. The solar collector, the main element of such systems, is the object of the present study. Flat plane collectors are widely used and have a consolidated technology. However, the market share of tubular evacuated glass collectors is rapidly increasing. These collectors are constituted by elements consisting in two concentrical tubes with vacuum in between. Instead of using a black painted sheet of metal as the absorbing element, the internal glass tube is coated with a selective surface. The vacuum provides a high level insulation, with evident benefits in severe cold climates. In order to allow a correct sizing of systems employing such collectors, their thermal performance parameters must be determined according to standard procedures. This work show the description of a test system, built at Laboratório de Energia Solar of Universidade do Rio Grande do Sul, which enable the testing of this type of collector. This test system features a carefully calibrated instrumentation and a device, developed in this work, for measuring the water temperature difference between the collector inlet and outlet with an accuracy of 0.05 °C. A test for estimating the thermal losses and the optical properties of two evacuated tubes with different selective surfaces (Al-N/SS/Cu e Al-N/Al) was also performed. The better performance of the tube with the selective surface deposited on a copper layer was. The experimental methodology was proven to be valid and useful for determining some parameters used in simulations. A test based on the current Brazilian standard with a solar collector with twenty water-in-glass vacuum tubes was performed. Its efficiency curve and its performance parameters were determined under steady state conditions. Some differences between the obtained values and manufacturer data were detected, probably due to the difference between the test conditions. The efficiency curve obtained for the tubular solar collector was compared to the curves of two flat plane collectors. This comparison indicated that the tested collector is more efficient under situations in which the difference between the temperature of the water inside the collector and the ambient temperature are higher.
6

Desenvolvimento de uma bancada para ensaios de coletores solares de tubos de vidro a vácuo

Manea, Tiago Francisco January 2012 (has links)
Sistemas de aquecimento de água que utilizam a conversão de energia solar em energia térmica, além de serem um meio fácil e limpo de geração de energia, trazem benefícios econômicos ao país e principalmente a quem os utiliza. O elemento principal destes sistemas, o coletor solar, é objeto de estudo neste trabalho. Coletores planos são amplamente utilizados e possuem uma tecnologia consolidada, porém, um tipo de coletor composto por tubos de vidro, com isolamento a vácuo e superfície absorvedora seletiva vem se tornando uma opção cada vez mais viável economicamente. Com benefícios evidentes em climas de frio mais intenso, estes coletores devem ter seus parâmetros de desempenho térmico determinados segundo procedimentos normativos, para que possam ser dimensionados de forma correta os sistemas de aquecimento que os utilizarem. Este trabalho descreve o desenvolvimento de uma bancada de ensaios construída no Laboratório de Energia Solar da Universidade Federal do Rio Grande do Sul, que tem o intuito de possibilitar o ensaio deste tipo de coletor. Esta bancada contou com uma instrumentação cuidadosamente calibrada e com um dispositivo, desenvolvido neste trabalho, capaz de realizar medidas da diferença de temperatura da água entre as seções de entrada e saída do coletor com uma incerteza inferior a 0,05 °C. Foram realizados ensaios individuais de dois tubos a vácuo de superfícies absorvedoras distintas desacoplados do coletor. Um ensaio determinou seu coeficiente de transferência de calor e outro avaliou as propriedades ópticas de cada tubo. A metodologia experimental utilizada se mostrou válida e possível de determinar alguns parâmetros para utilização em simulações. Um melhor desempenho do tubo com superfície seletiva de (Al-N/SS/Cu) em relação ao que utiliza (Al-N/Al) ficou evidente nestes ensaios. Foi realizado na bancada desenvolvida o ensaio de um coletor de tubos de vidro a vácuo que utiliza o principio de transferência direta. Sua curva de eficiência e seus parâmetros de desempenho foram determinados sob condições de regime permanente. Houve pequena diferença entre os valores obtidos e os fornecidos pelo fabricante, o que deve ter ocorrido, em parte, devido à diferença das condições de realização dos ensaios. A curva de desempenho obtida neste trabalho para o coletor de tubos de vidro a vácuo foi comparada às curvas de dois coletores planos. Nesta comparação ficou evidente que o coletor ensaiado é mais eficiente em situações onde a diferença entre a temperatura da água no interior do coletor e temperatura ambiente são maiores. / The use of solar systems for heating water brings economic benefits to the country and especially to the users. Furthermore, it is an easy and clean form of energy generation. The solar collector, the main element of such systems, is the object of the present study. Flat plane collectors are widely used and have a consolidated technology. However, the market share of tubular evacuated glass collectors is rapidly increasing. These collectors are constituted by elements consisting in two concentrical tubes with vacuum in between. Instead of using a black painted sheet of metal as the absorbing element, the internal glass tube is coated with a selective surface. The vacuum provides a high level insulation, with evident benefits in severe cold climates. In order to allow a correct sizing of systems employing such collectors, their thermal performance parameters must be determined according to standard procedures. This work show the description of a test system, built at Laboratório de Energia Solar of Universidade do Rio Grande do Sul, which enable the testing of this type of collector. This test system features a carefully calibrated instrumentation and a device, developed in this work, for measuring the water temperature difference between the collector inlet and outlet with an accuracy of 0.05 °C. A test for estimating the thermal losses and the optical properties of two evacuated tubes with different selective surfaces (Al-N/SS/Cu e Al-N/Al) was also performed. The better performance of the tube with the selective surface deposited on a copper layer was. The experimental methodology was proven to be valid and useful for determining some parameters used in simulations. A test based on the current Brazilian standard with a solar collector with twenty water-in-glass vacuum tubes was performed. Its efficiency curve and its performance parameters were determined under steady state conditions. Some differences between the obtained values and manufacturer data were detected, probably due to the difference between the test conditions. The efficiency curve obtained for the tubular solar collector was compared to the curves of two flat plane collectors. This comparison indicated that the tested collector is more efficient under situations in which the difference between the temperature of the water inside the collector and the ambient temperature are higher.
7

Estudo numérico de características de escoamento e transferência de calor em coletor solar de tubo evacuado

Souza, Fábio Ricardo de Oliveira de 31 January 2013 (has links)
Submitted by Maicon Juliano Schmidt (maicons) on 2015-07-15T13:18:20Z No. of bitstreams: 1 Fábio Ricardo de Oliveira de Souza.pdf: 10103280 bytes, checksum: 4e2fd0c8307348f7e9098749cafe8b73 (MD5) / Made available in DSpace on 2015-07-15T13:18:20Z (GMT). No. of bitstreams: 1 Fábio Ricardo de Oliveira de Souza.pdf: 10103280 bytes, checksum: 4e2fd0c8307348f7e9098749cafe8b73 (MD5) Previous issue date: 2013-01-31 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / PROSUP - Programa de Suporte à Pós-Gradução de Instituições de Ensino Particulares / Este trabalho apresenta um estudo numérico sobre características de escoamento e transferência de calor em tubo evacuado. A abordagem numérica foi realizada com o software comercial ANSYS-CFX. O modelo numérico adotado é tridimensional e é composto pelas equações da conservação da massa, quantidade de movimento e energia. A malha computacional é do tipo hexaédrica, com refinamento nas regiões de maiores gradientes térmicos e fluidodinâmicos. O modelo implementado foi validado com resultados numéricos da literatura e um estudo de caso foi realizado, considerando variações do ângulo de inclinação do tubo, da variação da taxa de transferência de calor para o tubo e da variação da temperatura da água proveniente do reservatório térmico. Também foram avaliadas duas hipóteses: uma considerando propriedades físicas da água constantes e a outra com propriedades variáveis com a temperatura. Comparações são apresentadas para campos de velocidade e temperatura, vazão mássica e números de Nusselt e de Reynolds. O comparativo entre os resultados obtidos com a hipótese de propriedades constantes, com aqueles obtidos com propriedades variáveis mostra diferenças significativas entre eles, apontando a importância do uso de propriedades variáveis neste tipo de simulação numérica. Os resultados dos estudos paramétricos indicam que o incremento da vazão mássica e da temperatura média de saída do fluido é diretamente proporcional ao incremento do ângulo de inclinação, da taxa de transferência de calor e da temperatura do reservatório térmico. / This work presents a numerical study on characteristics of flow and heat transfer in an evacuated tube. The numerical approach was performed with the commercial software ANSYS-CFX. The numerical model adopted is three-dimensional and consists of the mass, momentum and energy equations. The computational mesh is hexaedrical, with refinement in regions of higher thermal and fluid gradients. The implemented model was validated with numerical results of literature and a case study was conducted considering inclination angle, rate of heat transfer and water temperature from the thermal reservoir. Also were evaluated two hypotheses: one considering constant physical properties of water and the other with properties varying with temperature. Comparisons are presented for velocity and temperature fields, mass flow and Nusselt and Reynolds numbers. The comparison between the results obtained with the hypothesis of constant properties, with those obtained with variable properties, shows significant differences between them, pointing out the importance of using variable properties in this type of numerical simulation. The results of the parametric studies indicate that the increment of the mass flow and average temperature of the fluid is directly proportional to the inclination angle, the rate of heat transfer and the temperature of the thermal reservoir.
8

Avaliação numérica e experimental da convecção natural em coletor solar de tubos evacuados

Manea, Tiago Francisco January 2016 (has links)
O coletor solar de tubos evacuados une uma alta absortividade de radiação solar a um ótimo grau de isolamento térmico. Estas características, aliadas a um custo relativamente baixo, fazem deste tipo de coletor o mais utilizado no mundo. Por isso, diversos tipos de abordagens estão sendo adotadas para descrever seu comportamento térmico. Nesta linha, este trabalho foi desenvolvido através de abordagem experimental e teórica, sendo a última subdividida em numérica por CFD e analítica. A abordagem experimental contou com a construção de uma bancada para medida de temperatura e radiação, em um coletor de 24 tubos evacuados acoplados em um reservatório de 178 L. A abordagem por CFD utilizou um modelo tridimensional transiente. Com o modelo numérico validado, utilizando resultados experimentais, simularam-se diferentes condições de operação, em termos de ângulo de inclinação, fluxo de calor sobre o coletor, tamanho do reservatório e temperatura de entrada da água. Em relação à abordagem analítica, esta é dividida em: modelo de irradiância, modelo do tubo e modelo do reservatório. O modelo de irradiância determina a distribuição da radiação solar ao longo da circunferência do tubo. Parte desta radiação é absorvida pelo coletor e transferida para água. Esta quantidade é determinada com o modelo do tubo, que é baseado no método de resistências térmicas. O modelo do reservatório descreve o comportamento térmico da água em seu interior, tanto em aquecimento quanto em resfriamento, analisando a interação energética com o coletor e com o meio externo. O desenvolvimento do modelo do tubo passa pela avaliação da vazão mássica entre o tubo e o reservatório, além disso, o coeficiente de transferência de calor por convecção no interior do tubo deve ser determinado. Tais variáveis são determinadas a partir de uma correlação para o número de Reynolds, a qual foi obtida com resultados da avaliação por CFD e é função dos números de Nusselt, Grashof e Prandtl. A correlação proposta apresentou bom ajuste com os resultados numéricos. Com a bancada de ensaio experimental foram feitas medidas de temperatura da água no reservatório ao longo de alguns dias. Para as mesmas condições do experimento, a temperatura média da água no reservatório foi estimada com resultados da integração dos modelos de irradiância, do tubo e do reservatório. A diferença entre os resultados experimental e teórico foi de 4,8% para a energia acumulada. / The evacuated tube solar collector combines high solar radiation absorptivity to a great thermal insulation degree. These characteristics, combined with a relatively low cost, make this type of collector the most used in the world. Therefore, various types of approaches are being adopted to describe its thermal behavior. In this way, this work was developed through experimental and theoretical approaches, the latter being subdivided into numeric, by CFD, and analytical analysis. For the experimental approach a test bench was built. The tests was carried on a solar collector with 24 evacuated tubes coupled to a 178 L tank, measuring temperature and solar radiation. The CFD approach used a transient three-dimensional model. After the numerical model validation using experimental data, simulations was carried over different operating conditions in terms of angle, heat flux on the collector, tank size and water inlet temperature. The analytical approach is divided into: irradiance model, tube model and tank model. The irradiance model determines the irradiance distribution of solar radiation along the circumference of the tube. Part of this radiation is absorbed by the collector and transferred to water, this amount is determined with the tube model, using the thermal resistance method. The tank model describes the thermal behavior of inside water, both in heating and in cooling, analyzing energy interaction with the collector and the external environment. The development of the tube model involves the assessment of the mass flow rate between the tube and the tank, furthermore the convection heat transfer coefficient inside the tube must be determined. These variables are determined from a correlation for the Reynolds number, which was obtained with evaluation results by CFD. Proposed Reynolds number is a function of the Nusselt, Prandtl and Grashof numbers. The correlation presented a good agreement with the numerical results. Using the experimental test bench the water temperature was measured into the tank over a few days. For the same experiment conditions, the average temperature of the water into the tank was estimated by results of integration of irradiance, tube and tank models. The difference between the experimental and theoretical results was 4.8% for the accumulated energy.
9

Avaliação numérica e experimental da convecção natural em coletor solar de tubos evacuados

Manea, Tiago Francisco January 2016 (has links)
O coletor solar de tubos evacuados une uma alta absortividade de radiação solar a um ótimo grau de isolamento térmico. Estas características, aliadas a um custo relativamente baixo, fazem deste tipo de coletor o mais utilizado no mundo. Por isso, diversos tipos de abordagens estão sendo adotadas para descrever seu comportamento térmico. Nesta linha, este trabalho foi desenvolvido através de abordagem experimental e teórica, sendo a última subdividida em numérica por CFD e analítica. A abordagem experimental contou com a construção de uma bancada para medida de temperatura e radiação, em um coletor de 24 tubos evacuados acoplados em um reservatório de 178 L. A abordagem por CFD utilizou um modelo tridimensional transiente. Com o modelo numérico validado, utilizando resultados experimentais, simularam-se diferentes condições de operação, em termos de ângulo de inclinação, fluxo de calor sobre o coletor, tamanho do reservatório e temperatura de entrada da água. Em relação à abordagem analítica, esta é dividida em: modelo de irradiância, modelo do tubo e modelo do reservatório. O modelo de irradiância determina a distribuição da radiação solar ao longo da circunferência do tubo. Parte desta radiação é absorvida pelo coletor e transferida para água. Esta quantidade é determinada com o modelo do tubo, que é baseado no método de resistências térmicas. O modelo do reservatório descreve o comportamento térmico da água em seu interior, tanto em aquecimento quanto em resfriamento, analisando a interação energética com o coletor e com o meio externo. O desenvolvimento do modelo do tubo passa pela avaliação da vazão mássica entre o tubo e o reservatório, além disso, o coeficiente de transferência de calor por convecção no interior do tubo deve ser determinado. Tais variáveis são determinadas a partir de uma correlação para o número de Reynolds, a qual foi obtida com resultados da avaliação por CFD e é função dos números de Nusselt, Grashof e Prandtl. A correlação proposta apresentou bom ajuste com os resultados numéricos. Com a bancada de ensaio experimental foram feitas medidas de temperatura da água no reservatório ao longo de alguns dias. Para as mesmas condições do experimento, a temperatura média da água no reservatório foi estimada com resultados da integração dos modelos de irradiância, do tubo e do reservatório. A diferença entre os resultados experimental e teórico foi de 4,8% para a energia acumulada. / The evacuated tube solar collector combines high solar radiation absorptivity to a great thermal insulation degree. These characteristics, combined with a relatively low cost, make this type of collector the most used in the world. Therefore, various types of approaches are being adopted to describe its thermal behavior. In this way, this work was developed through experimental and theoretical approaches, the latter being subdivided into numeric, by CFD, and analytical analysis. For the experimental approach a test bench was built. The tests was carried on a solar collector with 24 evacuated tubes coupled to a 178 L tank, measuring temperature and solar radiation. The CFD approach used a transient three-dimensional model. After the numerical model validation using experimental data, simulations was carried over different operating conditions in terms of angle, heat flux on the collector, tank size and water inlet temperature. The analytical approach is divided into: irradiance model, tube model and tank model. The irradiance model determines the irradiance distribution of solar radiation along the circumference of the tube. Part of this radiation is absorbed by the collector and transferred to water, this amount is determined with the tube model, using the thermal resistance method. The tank model describes the thermal behavior of inside water, both in heating and in cooling, analyzing energy interaction with the collector and the external environment. The development of the tube model involves the assessment of the mass flow rate between the tube and the tank, furthermore the convection heat transfer coefficient inside the tube must be determined. These variables are determined from a correlation for the Reynolds number, which was obtained with evaluation results by CFD. Proposed Reynolds number is a function of the Nusselt, Prandtl and Grashof numbers. The correlation presented a good agreement with the numerical results. Using the experimental test bench the water temperature was measured into the tank over a few days. For the same experiment conditions, the average temperature of the water into the tank was estimated by results of integration of irradiance, tube and tank models. The difference between the experimental and theoretical results was 4.8% for the accumulated energy.
10

Avaliação numérica e experimental da convecção natural em coletor solar de tubos evacuados

Manea, Tiago Francisco January 2016 (has links)
O coletor solar de tubos evacuados une uma alta absortividade de radiação solar a um ótimo grau de isolamento térmico. Estas características, aliadas a um custo relativamente baixo, fazem deste tipo de coletor o mais utilizado no mundo. Por isso, diversos tipos de abordagens estão sendo adotadas para descrever seu comportamento térmico. Nesta linha, este trabalho foi desenvolvido através de abordagem experimental e teórica, sendo a última subdividida em numérica por CFD e analítica. A abordagem experimental contou com a construção de uma bancada para medida de temperatura e radiação, em um coletor de 24 tubos evacuados acoplados em um reservatório de 178 L. A abordagem por CFD utilizou um modelo tridimensional transiente. Com o modelo numérico validado, utilizando resultados experimentais, simularam-se diferentes condições de operação, em termos de ângulo de inclinação, fluxo de calor sobre o coletor, tamanho do reservatório e temperatura de entrada da água. Em relação à abordagem analítica, esta é dividida em: modelo de irradiância, modelo do tubo e modelo do reservatório. O modelo de irradiância determina a distribuição da radiação solar ao longo da circunferência do tubo. Parte desta radiação é absorvida pelo coletor e transferida para água. Esta quantidade é determinada com o modelo do tubo, que é baseado no método de resistências térmicas. O modelo do reservatório descreve o comportamento térmico da água em seu interior, tanto em aquecimento quanto em resfriamento, analisando a interação energética com o coletor e com o meio externo. O desenvolvimento do modelo do tubo passa pela avaliação da vazão mássica entre o tubo e o reservatório, além disso, o coeficiente de transferência de calor por convecção no interior do tubo deve ser determinado. Tais variáveis são determinadas a partir de uma correlação para o número de Reynolds, a qual foi obtida com resultados da avaliação por CFD e é função dos números de Nusselt, Grashof e Prandtl. A correlação proposta apresentou bom ajuste com os resultados numéricos. Com a bancada de ensaio experimental foram feitas medidas de temperatura da água no reservatório ao longo de alguns dias. Para as mesmas condições do experimento, a temperatura média da água no reservatório foi estimada com resultados da integração dos modelos de irradiância, do tubo e do reservatório. A diferença entre os resultados experimental e teórico foi de 4,8% para a energia acumulada. / The evacuated tube solar collector combines high solar radiation absorptivity to a great thermal insulation degree. These characteristics, combined with a relatively low cost, make this type of collector the most used in the world. Therefore, various types of approaches are being adopted to describe its thermal behavior. In this way, this work was developed through experimental and theoretical approaches, the latter being subdivided into numeric, by CFD, and analytical analysis. For the experimental approach a test bench was built. The tests was carried on a solar collector with 24 evacuated tubes coupled to a 178 L tank, measuring temperature and solar radiation. The CFD approach used a transient three-dimensional model. After the numerical model validation using experimental data, simulations was carried over different operating conditions in terms of angle, heat flux on the collector, tank size and water inlet temperature. The analytical approach is divided into: irradiance model, tube model and tank model. The irradiance model determines the irradiance distribution of solar radiation along the circumference of the tube. Part of this radiation is absorbed by the collector and transferred to water, this amount is determined with the tube model, using the thermal resistance method. The tank model describes the thermal behavior of inside water, both in heating and in cooling, analyzing energy interaction with the collector and the external environment. The development of the tube model involves the assessment of the mass flow rate between the tube and the tank, furthermore the convection heat transfer coefficient inside the tube must be determined. These variables are determined from a correlation for the Reynolds number, which was obtained with evaluation results by CFD. Proposed Reynolds number is a function of the Nusselt, Prandtl and Grashof numbers. The correlation presented a good agreement with the numerical results. Using the experimental test bench the water temperature was measured into the tank over a few days. For the same experiment conditions, the average temperature of the water into the tank was estimated by results of integration of irradiance, tube and tank models. The difference between the experimental and theoretical results was 4.8% for the accumulated energy.