• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • Tagged with
  • 24
  • 16
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo de métodos de extrapolação superior de curvas-chave

Sefione, André Luiz January 2002 (has links)
A busca de maior precisão nos dados hidrológicos é de fundamental importância no sentido de minimizar as incertezas inerentes aos mesmos e, conseqüentemente, aos estudos e projetos que os têm como base. A curva-chave, ferramenta importante na conversão de dados de cota em vazão, carece de estudos no sentido de aumentar a confiabilidade na sua calibragem e principalmente na sua extrapolação inferior e superior. O objetivo deste trabalho é avaliar os métodos tradicionais de extrapolação superior da curva-chave, a saber: Stevens, Logarítmico, Manning e Velocidade-Área, além de duas variações propostas para os dois últimos (Manning Log e VxA Log). Para tal foram utilizadas 100 estações fluviométricas, a partir de uma metodologia proposta e denominada de Pseudo- Extrapolação. Nesta metodologia, suprimem-se as medições na metade superior da faixa de cotas medidas e extrapola-se a curva-chave nesta faixa utilizando-se os métodos escolhidos. As vazões geradas nesta 'extrapolação' são comparadas com as da curva-chave calibrada para o total das medições. Os resultados mostraram que a metodologia de pseudo-extrapolação proposta é uma ferramenta válida para comparação entre métodos de extrapolação, até onde as características da seção transversal na faixa extrapolada sejam semelhantes às da faixa de pseudoextrapolação. Em relação aos métodos de extrapolação avaliados verificou-se que os métodos de Stevens e Manning Log mostraram resultados ligeiramente melhores que os demais e o método Logarítmico, apesar da inconstância nos erros calculados, mostrou-se como uma opção que deve ser admitida num estudo de extrapolação de curvas-chave. Além disso, as variações propostas, Manning Log e VxA Log, apresentaram resultados que merecem uma investigação mais profunda.
2

Estudo comparativo de métodos de extrapolação superior de curvas-chave

Sefione, André Luiz January 2002 (has links)
A busca de maior precisão nos dados hidrológicos é de fundamental importância no sentido de minimizar as incertezas inerentes aos mesmos e, conseqüentemente, aos estudos e projetos que os têm como base. A curva-chave, ferramenta importante na conversão de dados de cota em vazão, carece de estudos no sentido de aumentar a confiabilidade na sua calibragem e principalmente na sua extrapolação inferior e superior. O objetivo deste trabalho é avaliar os métodos tradicionais de extrapolação superior da curva-chave, a saber: Stevens, Logarítmico, Manning e Velocidade-Área, além de duas variações propostas para os dois últimos (Manning Log e VxA Log). Para tal foram utilizadas 100 estações fluviométricas, a partir de uma metodologia proposta e denominada de Pseudo- Extrapolação. Nesta metodologia, suprimem-se as medições na metade superior da faixa de cotas medidas e extrapola-se a curva-chave nesta faixa utilizando-se os métodos escolhidos. As vazões geradas nesta 'extrapolação' são comparadas com as da curva-chave calibrada para o total das medições. Os resultados mostraram que a metodologia de pseudo-extrapolação proposta é uma ferramenta válida para comparação entre métodos de extrapolação, até onde as características da seção transversal na faixa extrapolada sejam semelhantes às da faixa de pseudoextrapolação. Em relação aos métodos de extrapolação avaliados verificou-se que os métodos de Stevens e Manning Log mostraram resultados ligeiramente melhores que os demais e o método Logarítmico, apesar da inconstância nos erros calculados, mostrou-se como uma opção que deve ser admitida num estudo de extrapolação de curvas-chave. Além disso, as variações propostas, Manning Log e VxA Log, apresentaram resultados que merecem uma investigação mais profunda.
3

Estudo comparativo de métodos de extrapolação superior de curvas-chave

Sefione, André Luiz January 2002 (has links)
A busca de maior precisão nos dados hidrológicos é de fundamental importância no sentido de minimizar as incertezas inerentes aos mesmos e, conseqüentemente, aos estudos e projetos que os têm como base. A curva-chave, ferramenta importante na conversão de dados de cota em vazão, carece de estudos no sentido de aumentar a confiabilidade na sua calibragem e principalmente na sua extrapolação inferior e superior. O objetivo deste trabalho é avaliar os métodos tradicionais de extrapolação superior da curva-chave, a saber: Stevens, Logarítmico, Manning e Velocidade-Área, além de duas variações propostas para os dois últimos (Manning Log e VxA Log). Para tal foram utilizadas 100 estações fluviométricas, a partir de uma metodologia proposta e denominada de Pseudo- Extrapolação. Nesta metodologia, suprimem-se as medições na metade superior da faixa de cotas medidas e extrapola-se a curva-chave nesta faixa utilizando-se os métodos escolhidos. As vazões geradas nesta 'extrapolação' são comparadas com as da curva-chave calibrada para o total das medições. Os resultados mostraram que a metodologia de pseudo-extrapolação proposta é uma ferramenta válida para comparação entre métodos de extrapolação, até onde as características da seção transversal na faixa extrapolada sejam semelhantes às da faixa de pseudoextrapolação. Em relação aos métodos de extrapolação avaliados verificou-se que os métodos de Stevens e Manning Log mostraram resultados ligeiramente melhores que os demais e o método Logarítmico, apesar da inconstância nos erros calculados, mostrou-se como uma opção que deve ser admitida num estudo de extrapolação de curvas-chave. Além disso, as variações propostas, Manning Log e VxA Log, apresentaram resultados que merecem uma investigação mais profunda.
4

Avaliação de ferramentas e métodos para a elaboração de mapas eólicos

LOUREIRO, Breno de Andrade 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:38:50Z (GMT). No. of bitstreams: 2 arquivo6453_1.pdf: 4622041 bytes, checksum: ed8506dd3b53ef28252dacc7bded0d0c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta uma avaliação de ferramentas e métodos para elaboração de mapas eólicos aplicados a projetos de centrais eólicas. Os mapas eólicos têm como função a determinação do potencial eólico local e servem de base para a locação de turbinas eólicas. Os modelos estudados estão implementados em ferramentas amplamente utilizadas no meio eólico: WAsP e o WindSim. Essas ferramentas apresentam parâmetros de entrada padrão que quando não ajustados podem resultar em extrapolações errôneas, visto a não representação correta do ambiente estudado. Para o estudo foi utilizado um ano de dados de intensidade e direção do vento provenientes da campanha de medição de duas torres anemométricas, com medições em três níveis de altura (20, 50 e 78 metros), localizadas numa região de complexidade topográfica moderada no interior da Paraíba - Brasil. Na primeira análise a comparação é realizada entre os valores calculados através de extrapolações das medições nas torres e os valores medidos nas torres, sem alterar os parâmetros padrão das ferramentas. Nesta análise, o modelo CFD do WindSim apresentou desvio médio quadrático de 2,18%, enquanto o modelo WAsP apresentou desvio médio quadrático de 10,21%, quando comparado com as medições nas torres. Na segunda análise os parâmetros de entrada do WAsP foram corrigidos para que fossem mais representativos para a atmosfera local, com ênfase para o parâmetro que representa a estabilidade atmosférica. A estabilidade atmosférica foi modelada através do gradiente vertical de temperatura medido na região estudada, com medições de temperatura em dois níveis de altura. Com esse ajuste o desvio médio quadrático do WAsP para a segunda análise diminuiu para 6,80%. Na terceira análise foram comparados todos os pontos dos mapas eólicos gerados pelo WAsP e pelo WindSim para área de interesse. Neste caso, verificou-se sobre estimativas na velocidade do vento de até 21% do mapa eólico WAsP em relação ao WindSim e sub estimativas de até 23%
5

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

Silva, Eric Alexandre Brito da 31 March 2011 (has links)
As câmaras de extrapolação são câmaras de ionização com volume variável e são utilizadas principalmente como detectores de radiação beta. Neste trabalho foram caracterizadas duas câmaras de extrapolação, uma comercial da marca PTW, e uma outra desenvolvida no Laboratório de Calibração do IPEN, para aplicação como sistemas de referência em feixes de mamografia, radiodiagnóstico convencional e radioterapia. Os resultados obtidos nos testes de caracterização da resposta das câmaras de extrapolação: corrente de fuga, estabilidade de curto e médio prazos, determinação das correntes de saturação e das eficiências de coleção de íons, dependência angular e energética, mostram que estas câmaras de extrapolação podem ser utilizadas em dosimetria de feixes de radiação X de energias baixas. Os fatores de transmissão no tecido e os fatores de calibração foram também determinados para todas as qualidades de radiação citadas. Finalmente, foi estabelecido um procedimento de calibração de detectores de radiação em feixes padronizados de radiação X, utilizando as câmaras de extrapolação. / The extrapolation chambers are ionization chambers with variable volume, and they are mainly utilized as beta radiation detectors. In this work two extrapolation chambers were characterized, a commercial PTW extrapolation chamber and another extrapolation chamber developed at the Calibration Laboratory of IPEN, for application as reference systems in mammography, conventional diagnostic radiology and radiotherapy beams. The results obtained from the characterization tests of the chamber response: leakage current, short- and medium terms stability, determination of the saturation currents and the ion collection efficiencies, angular and energy dependence, show that these extrapolation chambers may be utilized for low-energy X radiation beam dosimetry. The transmission factors in tissue and the calibration factors were also determined for all cited radiation qualities. Finally, a procedure was established for calibration of radiation detectors in standard X radiation beams, using the extrapolation chambers.
6

Caracterização e aplicação de duas câmaras de extrapolação em feixes padronizados de radiação X / Characterization and application of two extrapolation chambers in standard X radiation beams

Eric Alexandre Brito da Silva 31 March 2011 (has links)
As câmaras de extrapolação são câmaras de ionização com volume variável e são utilizadas principalmente como detectores de radiação beta. Neste trabalho foram caracterizadas duas câmaras de extrapolação, uma comercial da marca PTW, e uma outra desenvolvida no Laboratório de Calibração do IPEN, para aplicação como sistemas de referência em feixes de mamografia, radiodiagnóstico convencional e radioterapia. Os resultados obtidos nos testes de caracterização da resposta das câmaras de extrapolação: corrente de fuga, estabilidade de curto e médio prazos, determinação das correntes de saturação e das eficiências de coleção de íons, dependência angular e energética, mostram que estas câmaras de extrapolação podem ser utilizadas em dosimetria de feixes de radiação X de energias baixas. Os fatores de transmissão no tecido e os fatores de calibração foram também determinados para todas as qualidades de radiação citadas. Finalmente, foi estabelecido um procedimento de calibração de detectores de radiação em feixes padronizados de radiação X, utilizando as câmaras de extrapolação. / The extrapolation chambers are ionization chambers with variable volume, and they are mainly utilized as beta radiation detectors. In this work two extrapolation chambers were characterized, a commercial PTW extrapolation chamber and another extrapolation chamber developed at the Calibration Laboratory of IPEN, for application as reference systems in mammography, conventional diagnostic radiology and radiotherapy beams. The results obtained from the characterization tests of the chamber response: leakage current, short- and medium terms stability, determination of the saturation currents and the ion collection efficiencies, angular and energy dependence, show that these extrapolation chambers may be utilized for low-energy X radiation beam dosimetry. The transmission factors in tissue and the calibration factors were also determined for all cited radiation qualities. Finally, a procedure was established for calibration of radiation detectors in standard X radiation beams, using the extrapolation chambers.
7

Caracterização e estabelecimento de um sistema padrão primário e de um sistema de transferência ou método alternativo/complementar de radiação beta / Characterization and establishment of a primary standard system and a transfer system or alternative/complementary method for beta radiation

Polo, Ivón Oramas 23 July 2019 (has links)
O problema da dosimetria beta está ligado a indivíduos que manipulam fontes radioativas a pequenas distâncias ou em contato. O objetivo principal da dosimetria beta é a determinação da dose na pele e no cristalino do olho. A câmara de extrapolação Böhm foi caracterizada em feixes de radiação beta das fontes de 85Kr e 147Pm e ela foi estabelecida como sistema de padronização primária. Foram determinadas as taxas de dose absorvida no ar e no tecido à profundidade nula e de 0,07 mm das fontes de 85Kr e 147Pm e os seus fatores de transmissão. Além disso, foi caracterizado e estabelecido um sistema de transferência ou método alternativo/complementar de dosimetria beta. Foram aplicadas as técnicas de termoluminescência e de luminescência opticamente estimulada, para a caracterização de detectores de SOL-GEL α-Al2O3 em campos padrões de radiação beta, e foram determinados os parâmetros cinéticos do processo termoluminiscente. O material estudado mostrou-se adequado para a dosimetria beta. Foi estabelecido um modelo computacional pelo método Monte Carlo para a câmara de extrapolação e para as fontes de radiação; foram determinadas as taxas de dose absorvida, os fatores de correção de Bremsstrahlung, os fatores de correção pelo retroespalhamento do eletrodo coletor e do anel de guarda da câmara de extrapolação e os fatores de dependência angular. Para o sistema de transferência de dosimetria beta, foram determinados os fatores de correção pela atenuação no ar e o espalhamento da radiação no suporte de irradiação dos detectores pelo método Monte Carlo. Todas os testes de caracterização, assim como o modelo de Monte Carlo, foram também realizados e implementados com a fonte de 90Sr/90Y por ser a fonte de referência da radiação beta e para fins comparativos. / The problem of beta dosimetry is linked to individuals who manipulate radioactive sources at small distances or in contact. The main objective of beta dosimetry is to determine the dose on the skin and in the lens of the eye. The Böhm extrapolation chamber was characterized in beta radiation beams from 85Kr and 147Pm sources, and a primary standard system was established. The absorbed dose rates in air and tissue at null depth and at 0.07 mm for 85Kr and 147Pm sources and the transmission factors were determined. In addition, a transfer system or alternative/complementary beta dosimetry method was characterized and established too. The thermoluminescence and optically stimulated luminescence techniques were applied for the characterization of the SOL-GEL α-Al2O3 detectors in standard beta radiation fields, and the kinetic parameters of the thermoluminescent process were determined. The studied material was shown to be suitable for beta dosimetry. A model by the Monte Carlo method for the extrapolation chamber and the radiation sources was established. The absorbed dose rates, the Bremsstrahlung correction factors, the correction factors for the backscattering of the collecting electrode and the guard ring of the extrapolation chamber, and the angular dependence factors were determined. For the beta dosimetry transfer system, the correction factors by attenuation in air and the scattering of the radiation in the irradiation holder of the detectors were determined by the Monte Carlo method. All the characterization and tests, as well as the Monte Carlo model, were performed and implemented with the 90Sr/90Y source, because it is the reference source for beta radiation and for comparative purposes.
8

Estabelecimento de padronização primária e de métodos relativos com o uso de técnicas luminescentes em dosimetria da radiação beta / Establishment of primary standardization and relative methods with the use of luminescent techniques in beta radiation dosimetry

Antonio, Patrícia de Lara 19 February 2014 (has links)
Devido à inexistência de um laboratório de padronização primária na América Latina, para calibração e dosimetria de fontes de radiação beta, neste trabalho uma câmara de extrapolação Böhm foi caracterizada e estabelecida como um sistema padrão primário no Laboratório de Calibração de Instrumentos (LCI) do IPEN. Como objetivo principal deste trabalho, a câmara de extrapolação Böhm foi caracterizada com relação à sua resposta em feixes padrões secundários de radiação beta de fontes de 90Sr+90Y, com duas janelas de entrada diferentes: Mylar aluminizado e Hostaphan grafitado, e com dois métodos de determinação de taxa de dose absorvida, para verificação do seu desempenho com cada material. Embora se trate do instrumento mais adequado para a calibração de detectores e fontes de radiação beta, a câmara de extrapolação deve ser utilizada apenas em laboratórios de calibração e não em programas de controle de qualidade, pois ela tem 7 kg e é de alto custo. Assim, é importante ter sistemas considerados padrões de trabalho e métodos alternativos para substituir a câmara de extrapolação em medições realizadas em campo, como em hospitais ou clínicas. Por este motivo, foram caracterizadas três câmaras de ionização de placas paralelas, com o objetivo de se verificar a possibilidade de seu uso como sistemas padrões de trabalho em programas de controle de qualidade, e também foram estudados materiais dosimétricos diferentes, em campos de radiação beta de 90Sr+90Y, utilizando-se os fenômenos da termoluminescência (TL) e da luminescência opticamente estimulada (LOE), como métodos alternativos na calibração de fontes de radiação beta. Inclui-se aqui o desenvolvimento de um sistema postal dosimétrico para a calibração de aplicadores clínicos de 90Sr+90Y. Os resultados obtidos com a câmara de extrapolação Böhm permitiram o seu estabelecimento como sistema padrão primário na calibração de fontes de 90Sr+90Y, pois a câmara com as duas janelas de entrada diferentes permitiram a determinação de taxas de dose absorvida no ar e no tecido, à profundidade nula e a 0,07 mm. A caracterização das três câmaras de ionização de placas paralelas mostraram que elas podem ser usadas em programas de controle de qualidade de fontes de radiação beta, pois suas respostas se apresentaram adequadas para esta finalidade. Os materiais dosimétricos testados com relação às suas respostas TL e LOE também se mostraram adequados para uso em campos de radiação beta, pois suas respostas foram satisfatórias. O sistema dosimétrico, utilizando dosímetros TL, foi testado em hospitais e, posteriormente, foi enviado na forma postal a um laboratório, contendo detectores TL e LOE, e o resultado da calibração dos aplicadores clínicos foi adequado. / Due to the lack of a primary standard laboratory at the Latin America, for the calibration and dosimetry of beta radiation sources, it was decided to establish the Böhm extrapolation chamber at the Calibration Laboratory (LCI) at IPEN as a primary standard. As a main objective of this work, the Böhm extrapolation chamber was characterized in relation to its response in beta radiation secondary standard beams of 90Sr+90Y sources, using two different entrance windows: aluminized Mylar and graphited Hostaphan, and using two methods of determination of absorbed dose rates, to verify its performance in each material. Although it is the most adequate instrument for the calibration of beta radiation detectors and sources, the extrapolation chamber should only be used at calibration laboratories, and not in quality control programs, because it weights 7 kg, and it is expensive. Thus, it is important to have systems considered work standards and alternative methods to replace the extrapolation chamber in measurements performed outside laboratories, such as in hospitals and clinics. For this reason, three parallel plate ionization chambers were characterized, with the objective to verify the possibility of their use as work standard systems, and different dosimetric materials were also studied, in beta radiation fields, using the thermoluminescence (TL) and optically stimulated luminescence (OSL) phenomena, as alternative methods for the calibration of beta radiation sources. The development of a dosimetric postal system for the calibration of 90Sr+90Y clinical applicators was included in this objective. The results obtained using the Böhm extrapolation chamber allowed its establishment as a primary standard system at the calibration of 90Sr+90Y sources, because it was possible to determine the absorbed dose rates in air and in the tissue, at null depth and 0.07 mm using the chamber with the two different entrance windows. The characterization of the three parallel plate ionization chambers showed that they can be used in quality control programs of beta radiation sources, because their responses were adequate to this purpose. The dosimetric materials were tested in relation to their TL and OSL response, and their use showed also to be adequate in beta radiation fields. The dosimetric postal system, using TL dosimeters, was tested in hospitals, and afterwards, it was sent to a laboratory, by conventional mail, with TL and OSL detectors, and the results of the calibration of the clinical applicators was adequate.
9

Estabelecimento de padronização primária e de métodos relativos com o uso de técnicas luminescentes em dosimetria da radiação beta / Establishment of primary standardization and relative methods with the use of luminescent techniques in beta radiation dosimetry

Patrícia de Lara Antonio 19 February 2014 (has links)
Devido à inexistência de um laboratório de padronização primária na América Latina, para calibração e dosimetria de fontes de radiação beta, neste trabalho uma câmara de extrapolação Böhm foi caracterizada e estabelecida como um sistema padrão primário no Laboratório de Calibração de Instrumentos (LCI) do IPEN. Como objetivo principal deste trabalho, a câmara de extrapolação Böhm foi caracterizada com relação à sua resposta em feixes padrões secundários de radiação beta de fontes de 90Sr+90Y, com duas janelas de entrada diferentes: Mylar aluminizado e Hostaphan grafitado, e com dois métodos de determinação de taxa de dose absorvida, para verificação do seu desempenho com cada material. Embora se trate do instrumento mais adequado para a calibração de detectores e fontes de radiação beta, a câmara de extrapolação deve ser utilizada apenas em laboratórios de calibração e não em programas de controle de qualidade, pois ela tem 7 kg e é de alto custo. Assim, é importante ter sistemas considerados padrões de trabalho e métodos alternativos para substituir a câmara de extrapolação em medições realizadas em campo, como em hospitais ou clínicas. Por este motivo, foram caracterizadas três câmaras de ionização de placas paralelas, com o objetivo de se verificar a possibilidade de seu uso como sistemas padrões de trabalho em programas de controle de qualidade, e também foram estudados materiais dosimétricos diferentes, em campos de radiação beta de 90Sr+90Y, utilizando-se os fenômenos da termoluminescência (TL) e da luminescência opticamente estimulada (LOE), como métodos alternativos na calibração de fontes de radiação beta. Inclui-se aqui o desenvolvimento de um sistema postal dosimétrico para a calibração de aplicadores clínicos de 90Sr+90Y. Os resultados obtidos com a câmara de extrapolação Böhm permitiram o seu estabelecimento como sistema padrão primário na calibração de fontes de 90Sr+90Y, pois a câmara com as duas janelas de entrada diferentes permitiram a determinação de taxas de dose absorvida no ar e no tecido, à profundidade nula e a 0,07 mm. A caracterização das três câmaras de ionização de placas paralelas mostraram que elas podem ser usadas em programas de controle de qualidade de fontes de radiação beta, pois suas respostas se apresentaram adequadas para esta finalidade. Os materiais dosimétricos testados com relação às suas respostas TL e LOE também se mostraram adequados para uso em campos de radiação beta, pois suas respostas foram satisfatórias. O sistema dosimétrico, utilizando dosímetros TL, foi testado em hospitais e, posteriormente, foi enviado na forma postal a um laboratório, contendo detectores TL e LOE, e o resultado da calibração dos aplicadores clínicos foi adequado. / Due to the lack of a primary standard laboratory at the Latin America, for the calibration and dosimetry of beta radiation sources, it was decided to establish the Böhm extrapolation chamber at the Calibration Laboratory (LCI) at IPEN as a primary standard. As a main objective of this work, the Böhm extrapolation chamber was characterized in relation to its response in beta radiation secondary standard beams of 90Sr+90Y sources, using two different entrance windows: aluminized Mylar and graphited Hostaphan, and using two methods of determination of absorbed dose rates, to verify its performance in each material. Although it is the most adequate instrument for the calibration of beta radiation detectors and sources, the extrapolation chamber should only be used at calibration laboratories, and not in quality control programs, because it weights 7 kg, and it is expensive. Thus, it is important to have systems considered work standards and alternative methods to replace the extrapolation chamber in measurements performed outside laboratories, such as in hospitals and clinics. For this reason, three parallel plate ionization chambers were characterized, with the objective to verify the possibility of their use as work standard systems, and different dosimetric materials were also studied, in beta radiation fields, using the thermoluminescence (TL) and optically stimulated luminescence (OSL) phenomena, as alternative methods for the calibration of beta radiation sources. The development of a dosimetric postal system for the calibration of 90Sr+90Y clinical applicators was included in this objective. The results obtained using the Böhm extrapolation chamber allowed its establishment as a primary standard system at the calibration of 90Sr+90Y sources, because it was possible to determine the absorbed dose rates in air and in the tissue, at null depth and 0.07 mm using the chamber with the two different entrance windows. The characterization of the three parallel plate ionization chambers showed that they can be used in quality control programs of beta radiation sources, because their responses were adequate to this purpose. The dosimetric materials were tested in relation to their TL and OSL response, and their use showed also to be adequate in beta radiation fields. The dosimetric postal system, using TL dosimeters, was tested in hospitals, and afterwards, it was sent to a laboratory, by conventional mail, with TL and OSL detectors, and the results of the calibration of the clinical applicators was adequate.
10

Atualizações sobre biologia e manejo conservacionista em primatas atelídeos da espécie Lagothrix cana

Carneiro, Marcelo Rocha January 2018 (has links)
Orientador: Lígia Souza Lima Silveira da Mota / Resumo: Este trabalho relata preliminarmente, a caracterização genética de primatas da espécie Lagothrix cana (macacos-barrigudos cinza), por meio de sequenciamento genético e análise de DNA mitocondrial do segmento D-Loop, após extração do DNA com a utilização da técnica do fenol/clorofórmio. Aliado a isso, é reportada uma revisão bibliográfica acerca dos dados anatômicos, fisiológicos, clínicos, reprodutivos e comportamentais, já disponíveis em literatura especializada sobre a espécie. Também, é validado um protocolo de contenção farmacológica executável e eficiente para procedimentos da rotina dos profissionais que desenvolvem ações, na área de medicina da conservação e atuam com primatas cativos deste gênero. Foram utilizados 21 primatas adultos da espécie Lagothrix cana (macaco-barrigudo), pesando 5,24 ± 1,66 kg, sendo 14 fêmeas e sete machos, para a validação deste protocolo. Os fármacos utilizados foram a tiletamina, o zolazepam, a atropina e a detomidina, em associação, com suas doses calculadas por meio de extrapolação alométrica interespecífica. Os fármacos foram combinados numa preparação concentrada que foi denominada “ZAD-50” (Zoletil/50® + Atropina + Detomidina), obtendo-se volume final exato de 3,0 ml de ZAD-50, com a associação de fármacos numa concentração que permite a contenção farmacológica de um mamífero placentário que pese 10,0 Kg com um volume de 0,6 ml, por exemplo. 567 pares de bases de DNA mitocondrial foram utilizadas, e conseguiu-se caracterizar os indiví... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This manuscript reports, at first, the genetic characterization of primates Lagothrix cana (“gray wooly-monkeys”), by means of DNA sequencing and mitochondrial DNA analysis of the D-Loop section, after the extraction with the phenol/chloroform method, described by Sambrook e Russel (2001). In addition, is related a wide vision of the scientific data available bibliographic about the anatomical, physiological, medical, reproductive and behavioural existing data, about the specie. Also is related a performable and efficient chemical restraint protocol to permit usual procedures for professionals of conservation medicine, who works with captive primates of Lagothrix sp. genus. The study evaluate the chemical restraint and field anesthesia of 21 wooly-monkeys (Lagothrix cana: Atelidae) weighing 5,24 ± 1,66 kg, being fourteen female and seven male. There was employed the combination of tiletamine, zolazepam, atropine, and detomidine, in allometrically scaled dosages. The drugs were combined in a concentrate preparation called “ZAD-50” (Zoletil/50® + Atropine + Dormiun-V®). and give an accurate final volume of 3.0 mL of ZAD-50, with the combination of drugs at a concentration that allows the pharmacological restraint of a placental mammal weighing 10.0 kg with a volume of 0.6 ml, for example. 567 base pairs of mitochondrial DNA samples was utilized and was realized the classification of the specimens as Lagothrix cana, after the comparison with L. poepigii and L. lagothricha data. ... (Complete abstract click electronic access below) / Doutor

Page generated in 0.0357 seconds