Spelling suggestions: "subject:"fármacos quiral"" "subject:"ármacos quiral""
1 |
Métodos para a determinação enantiomérica dos fármacos omeprazol, lansoprazol e pantoprazol em águas residuais e de estuário / Methods for the enantiomeric determination of omeprazole, lansoprazole and pantoprazole drugs in estuarine and wastewatersVanzolini, Kenia Lourenço 17 April 2009 (has links)
Made available in DSpace on 2016-06-02T20:36:22Z (GMT). No. of bitstreams: 1
2537.pdf: 7032312 bytes, checksum: 58b8058ab3f086b95831d5fd832c5897 (MD5)
Previous issue date: 2009-04-17 / Universidade Federal de Sao Carlos / The use of restricted access media columns for direct injection of samples chemically complex is consolidated, but not for environmental samples. This work describes the conditions for exclusion of aquatic fulvic and humic acids. The analyses were performed comparing the areas obtained after direct injection of standards in a chromatography column of gel permeation (Tsk gel® G3000PWXL), and those obtained in in-line mode with the RAM-BSA. Through a calibration curve, using standards of sodium polystyrene sulfonates of different molecular weights, in order of the 18000 Da, the molecular weight of eluted fractions were determined. This work reports the development, validation and application of sensitive, precise and accuracy methods, by high performance liquid chromatography with direct injection of samples for the enantioselective determination of omeprazole, lansoprazole and pantoprazole drugs in environmental matrices (wastewater from the city of São Carlos, Brazil and estuarine water of the River Douro, Porto-Portugal). The methods were developed by multidimensional liquid chromatography using an octyl restricted access media bovine serum albumin column (RAM-BSA C8) in the first dimension for the exclusion of macromolecules and extraction of drugs. The enantiomeric separation of omeprazole was achieved in the second dimension with a chiral column, amylose tris (3,5-dimetylphenylcarbamate) coated onto APS-Nucleosil support, and the chiral column amylose tris (3,5- dimethoxyphenylcarbamate) coated onto APS-Nucleosil support it was used for simultaneous enantiomeric separation of lansoprazole and pantoprazole. Aliquots of 500μL of the samples were injected directly into the multidimensional chromatographic system with detection for ultraviolet-visible spectroscopy (UV-vis). The quantification limits obtained for the enantiomers of omeprazole were 15μg.L-1, and for the enantiomers of lansoprazole and pantoprazole 5.0 and 7.5μg.L-1, respectively. Lower quantification limits were obtained for the enantiomers of lansoprazole (0,60μg.L-1) and pantoprazole (0,40μg.L-1) by replacement of the UV-vis detector for the mass spectrometer in a multiple reaction monitoring (MRM) mode and increasing the injection volume for 1000μL. / O uso de colunas de fases de acesso restrito para injeção direta de amostras quimicamente complexas está consolidado, mas não para amostras ambientais. Este trabalho descreve as condições para exclusão de ácidos húmicos e fúlvicos aquáticos. As análises foram feitas comparando as áreas obtidas após injeção direta dos padrões numa coluna cromatográfica de permeação em gel (Tsk gel® G3000PWXL), e as obtidas no modo in-line com as colunas RAM-BSA. Através de uma curva de calibração utilizando padrões de poliestirenos sulfonatos de sódio com diferentes pesos moleculares foi determinado, na ordem de 18000 Da, o peso molecular das frações eluídas. Este trabalho reporta o desenvolvimento, validação e aplicação de métodos sensíveis, precisos e exatos, por cromatografia líquida de alta eficiência com injeção direta de amostras para a determinação enantiosseletiva dos fármacos omeprazol, pantoprazol e lansoprazol, em matrizes ambientais (água residual da cidade de São Carlos-Brasil e água do estuário do Rio Douro, Porto-Portugal). Os métodos foram desenvolvidos por cromatografia liquida multidimensional utilizando-se uma coluna de fase acesso restrito de albumina sérica bovina (RAM-BSA C8), na primeira dimensão, para exclusão das macromoléculas e para extração dos fármacos. A separação enantiomérica do omeprazol foi realizada na segunda dimensão com uma coluna quiral, tris (3,5-dimetilfenilcarbamato) de amilose em APS-Nucleosil e, para os métodos envolvendo a separação enantiomérica simultânea do lansoprazol e pantoprazol foi utilizada a coluna quiral tris (3,5- dimetoxifenilcarbamato) de amilose em APS-Nucleosil. Alíquotas de 500μL das amostras foram injetadas diretamente no sistema cromatográfico multidimensional com detecção por espectroscopia na região do ultravioletaxix visível (UV-vis). Os limites de quantificação obtidos para os enantiômeros do omeprazol foram de 15μg.L-1, e para os enantiômeros do lansoprazol e pantoprazol 5,0 e 7,5μg.L-1, respectivamente. Limites inferiores de quantificação foram obtidos para os enantiômeros do lansoprazol (0,60μg.L-1 ) e pantoprazol (0,40μg.L-1), pela substituição do detector de UV-vis por um espectrômetro de massas, no modo MRM (Multiple Reaction Monitoring), e aumento do volume de injeção para 1000μL.
|
2 |
Separação enantiomérica de fármacos em medicamentos por cromatografia líquida com fase estacionária quiral / Direct enantiomeric separation of drugs in pharmaceutical by high performance liquid chromatography with chiral stationary phaseSingh, Anil Kumar 21 January 2002 (has links)
A maioria dos agentes terapêuticos, freqüentemente prescritos, são formulados e comercializados sob a forma racêmica, embora para alguns deles, já tenha sido demonstrado que os efeitos farmacológicos e/ou tóxicos estejam relacionados apenas a um dos enantiômeros. Além disso, é conhecido o fato de que os enantiômeros podem apresentar perfis farmacocinéticos e farmacodinâmicos diferentes. Neste trabalho foram selecionados fármacos que fazem parte de dois grupos importantes no uso clínico. São fármacos freqüentemente prescritos, como os β-bloqueadores (atenolol, metoprolol, pindolol, betaxolol e nadolol) e os antiinflamatórios não-esteróides (ibuprofeno e flurbiprofeno ). Existem na literatura científica várias citações que descrevem o uso da cromatografia líquida de alta eficiência com fases estacionárias quirais (CLAE-FEQ) em estudos farmacológicos, mas não na análise quantitativa dos enantiômeros em preparações farmacêuticas. É conhecido o fato de que o método CLAE-FEQs oferece vantagens sobre as técnicas clássicas de separação e análise de estereoisômeros, especialmente para os enantiômeros. As separações enantioméricas diretas do atenolol, metoprolol, nadolol e betaxolol foram obtidas utilizando-se FEQ Chiralcel OD®. Os enantiômeros do pindolol foram separados com FEQ α-Burke 2® e os do ibuprofeno e do flurbiprofeno com FEQ do tipo WheIk-O 1®. Neste trabalho são apresentados métodos rápidos e sensíveis para determinação estereoespecífica do atenolol (AT), do metoprolol (MT) e do flurbiprofeno (FLU) em formulações farmacêuticas. A determinação quantitativa dos enantiômeros do atenolol e do metoprolol nos comprimidos foi realizada através de método cromatográfico validado. As condições analíticas foram padronizadas através do sistema de cromatografia líquida de alta eficiência, usando coluna do tipo carbamato de celulose tris-3,5-dimetilfenil, Chiralcel OD®, (250x4.6 mm, 10µm) como FEQ. As amostras foram cromatografadas à temperatura ambiente, com um volume de injeção de 20µ L. A detecção foi efetuada em 276 nm. Para o atenolol a fase móvel foi constituída de hexano:etanol:dietilamina:ácido acético (60:40:0,2:0,2 v/v/v/v), com vazão de 1,0 rnL/min. As curvas padrões do R-AT e do S-AT apresentaram boa linearidade entre 50,0-130,0µg/rnL, com coeficiente de correlação de 0,9991 e 0,9980 respectivamente. As amostras comerciais A, B, C e D referentes a R-AT analisadas, apresentaram coeficiente de variação e percentual de recuperação de 1,15% e 101,06%; 0,74% e 99,25%; 1,05% e 102,57%; 0,84% e 101,57% respectivamente, já o coeficiente de variação e percentual de recuperação do S- AT nas amostras A, B, C e D foram 1,33% e 98,87%; 0,99% e 100,76%; 1,17% e 101,69%; 1,26% e 100,39%, respectivamente. Para o metoprolol a fase móvel foi constituída de hexano:etanol:dietilamina:ácido acético (40:60:0,2:0,2 v/v/v/v), com vazão de 0,8 rnL/min. As curvas padrões do R-MT e do S-MT apresentaram boa linearidade entre 30,0-110,0µg/rnL, com coeficiente de correlação de 0,9988 e 0,9990 respectivamente. A amostra comercial analisada, apresentou coeficiente de variação e percentual de recuperação de 0,86% e 98,62% para R-MT e de 1,40% e 99,39% para S-MT. Um método cromatográfico foi desenvolvido e validado para separação e quantificação enantiomérica do FLU na forma farmacêutica. As condições analíticas foram padronizadas através do sistema de cromatografia líquida de alta eficiência, usando coluna do tipo Whelk-O 1® (250x4,6 mm, 5,0 µm) como FEQ. As amostras foram cromatografadas à temperatura ambiente, com um volume de injeção de 20µ L. A detecção foi efetuada em 246 nm. A fase móvel foi constituída de hexano:etanol:ácido acético (95:05:0,2 v/v/v), com vazão de 0,9 rnL/min. A curva padrão do S-FLU apresentou boa linearidade entre 2,0-18,0 µg/mL, com coeficiente de correlação de 0,9993. A amostra comercial analisada apresentou coeficiente de variação e percentual de recuperação de 0,16% e 100,1% para R_FLU e 0,14% e 100,4% para S-FLU, respectivamente. Os métodos propostos permitam a separação quantitativa dos enantiômeros de AT, MT e FLU contidos nas formas farmacêuticas analisadas, com precisão e exatidão e que podem ser aplicados no controle de qualidade enantiomérico destes fármacos. / The majority of the therapeutic agents, frequently prescribed, are formulated and commercialized as racemic mixture, even so for some of them, it has been demonstrated that the pharmacological and/or toxic effect are confined only to one of the enantiomer. Besides, it is well known that the enantiomers can present different pharmacokinetic and pharmacodynamic profiles. In the present work we selected drugs belonging to two classes of clínical importance. These pharmaceuticals are widely prescribed in clinical practice such as, the beta-blockers (atenolol, metoprolol, pindoloI, betaxolol and nadolol) and the non-steroid anti-inflammatorydrugs (ibuprofen and flurbiprofen). Several references could be found in scientific literature that describes the use of high performance liquid chromatography with chiral stationary phase (HPLC-CSP) in pharmacological studies, seldom in the quantitative determination of enantiomers in pharmaceutical formulations. It is well known that the HPLC-CSP methods offer distinct advantages over classical techniques of isomeric separation and analysis, especially for the enantiomeric separation. The direct enantiomeric separation of atenolol metoprolol nadolol and betaxolol were obtained using CSP Chiralcel OD®.The enantiomers of pindolol were separate utilizing CSP α-Burke 2® and those of ibuprofen and the flurbiprofen with CSP Whelk-O 1®. In this work are presented efficient and sensitive methods for stereospecific determination of atenolol (AT), metoprolol (MT) and flurbiprofen (FLU) in pharmaceutical formulations. The stereoselective determination of atenolol and metoprolol in pharmaceuticals was performed through validated chromatographic method. The validation of liquid chromatographic methods was done utilizing a cellulose tris- 3,5-dimethylphenyl carbamate, Chiralcel OD®, (250x4.6 mm, 10µm)as CSP. The samples were analyzed at room temperature with injection volume of 20µL and UV detection was made at 276nm. In case of atenolol, the mobile phase was constituted of hexane:ethanol:diethylamine:acetic acid (60:40:0.2:0.2 v/v), with a flow rate of 1.0 mL/min. Separate standard curve for R-AT and S-AT showed good linearity over a concentration range from 50-130 µg/mL, with coefficient of correlation of 0.9991 and 0.998, respectively. The coefficient of variation and average recovery for R-AT in the samples A, B, C, and D were 1.15% and 101.06%; 0.74% and 99.25%; 1.05% and 102.57%; 0.84% and 101.57% respectively. The coefficient of variation and average recovery for S-AT in samples A, B, C and D were 1.33% and 98.87%; 0.99% and 100.76%; 1.17% and 101.69%; 1.26% and 100.39%, respectively. In case of metoprolol, the mobile phase was constituted of hexane:ethanol:diethylamine:acetic acid (40:60:0.2:0.2 v/v), with a flow rate of 0.8 m L/min. Separate standard curve for R-MT and S-MT showed good linearity over a concentration range fIom 30-110 µg/mL, with coefficient of correlation of 0.9988 and 0.9990, respectively. The coefficient of variation and average recovery for R-MT in sample analyzed was 0.86% and 98.62% and for S-MT was 1.40% and 99.39%, respectively. A high performance liquid chromatographic method is developed and validated for enantiomeric separation and quantitative determination of FLU in pharmaceutical preparation. A WheIk-O 1® column (250x4.6 mm, 5µm)was used as chiral stationary phase (CSP). The mobile phase was constituted of hexane:ethanol:acetic acid (95:05:0.2 v/v/v), at a flow rate of 0.9 rnL/min and UV detection at 246nm. All experiments were done at ambient temperature. The S-FLU standard curve showed linearity over a concentration range from 2-18µg/mL, (R2 = 0.9993). The coefficient of variation and average recovery of R-FLU were 0.16% and 100.13% and for S-FLU were 0.14% and 100.4%; respectively. The proposed methods permits quantitative separation of AT, MT and FLU enantiomers in pharmaceutical formulations studied with precision and accuracy. The proposed validated methods can be used in the enantiomeric quality controI of referred pharmaceutical drugs.
|
3 |
Separação enantiomérica de fármacos em medicamentos por cromatografia líquida com fase estacionária quiral / Direct enantiomeric separation of drugs in pharmaceutical by high performance liquid chromatography with chiral stationary phaseAnil Kumar Singh 21 January 2002 (has links)
A maioria dos agentes terapêuticos, freqüentemente prescritos, são formulados e comercializados sob a forma racêmica, embora para alguns deles, já tenha sido demonstrado que os efeitos farmacológicos e/ou tóxicos estejam relacionados apenas a um dos enantiômeros. Além disso, é conhecido o fato de que os enantiômeros podem apresentar perfis farmacocinéticos e farmacodinâmicos diferentes. Neste trabalho foram selecionados fármacos que fazem parte de dois grupos importantes no uso clínico. São fármacos freqüentemente prescritos, como os β-bloqueadores (atenolol, metoprolol, pindolol, betaxolol e nadolol) e os antiinflamatórios não-esteróides (ibuprofeno e flurbiprofeno ). Existem na literatura científica várias citações que descrevem o uso da cromatografia líquida de alta eficiência com fases estacionárias quirais (CLAE-FEQ) em estudos farmacológicos, mas não na análise quantitativa dos enantiômeros em preparações farmacêuticas. É conhecido o fato de que o método CLAE-FEQs oferece vantagens sobre as técnicas clássicas de separação e análise de estereoisômeros, especialmente para os enantiômeros. As separações enantioméricas diretas do atenolol, metoprolol, nadolol e betaxolol foram obtidas utilizando-se FEQ Chiralcel OD®. Os enantiômeros do pindolol foram separados com FEQ α-Burke 2® e os do ibuprofeno e do flurbiprofeno com FEQ do tipo WheIk-O 1®. Neste trabalho são apresentados métodos rápidos e sensíveis para determinação estereoespecífica do atenolol (AT), do metoprolol (MT) e do flurbiprofeno (FLU) em formulações farmacêuticas. A determinação quantitativa dos enantiômeros do atenolol e do metoprolol nos comprimidos foi realizada através de método cromatográfico validado. As condições analíticas foram padronizadas através do sistema de cromatografia líquida de alta eficiência, usando coluna do tipo carbamato de celulose tris-3,5-dimetilfenil, Chiralcel OD®, (250x4.6 mm, 10µm) como FEQ. As amostras foram cromatografadas à temperatura ambiente, com um volume de injeção de 20µ L. A detecção foi efetuada em 276 nm. Para o atenolol a fase móvel foi constituída de hexano:etanol:dietilamina:ácido acético (60:40:0,2:0,2 v/v/v/v), com vazão de 1,0 rnL/min. As curvas padrões do R-AT e do S-AT apresentaram boa linearidade entre 50,0-130,0µg/rnL, com coeficiente de correlação de 0,9991 e 0,9980 respectivamente. As amostras comerciais A, B, C e D referentes a R-AT analisadas, apresentaram coeficiente de variação e percentual de recuperação de 1,15% e 101,06%; 0,74% e 99,25%; 1,05% e 102,57%; 0,84% e 101,57% respectivamente, já o coeficiente de variação e percentual de recuperação do S- AT nas amostras A, B, C e D foram 1,33% e 98,87%; 0,99% e 100,76%; 1,17% e 101,69%; 1,26% e 100,39%, respectivamente. Para o metoprolol a fase móvel foi constituída de hexano:etanol:dietilamina:ácido acético (40:60:0,2:0,2 v/v/v/v), com vazão de 0,8 rnL/min. As curvas padrões do R-MT e do S-MT apresentaram boa linearidade entre 30,0-110,0µg/rnL, com coeficiente de correlação de 0,9988 e 0,9990 respectivamente. A amostra comercial analisada, apresentou coeficiente de variação e percentual de recuperação de 0,86% e 98,62% para R-MT e de 1,40% e 99,39% para S-MT. Um método cromatográfico foi desenvolvido e validado para separação e quantificação enantiomérica do FLU na forma farmacêutica. As condições analíticas foram padronizadas através do sistema de cromatografia líquida de alta eficiência, usando coluna do tipo Whelk-O 1® (250x4,6 mm, 5,0 µm) como FEQ. As amostras foram cromatografadas à temperatura ambiente, com um volume de injeção de 20µ L. A detecção foi efetuada em 246 nm. A fase móvel foi constituída de hexano:etanol:ácido acético (95:05:0,2 v/v/v), com vazão de 0,9 rnL/min. A curva padrão do S-FLU apresentou boa linearidade entre 2,0-18,0 µg/mL, com coeficiente de correlação de 0,9993. A amostra comercial analisada apresentou coeficiente de variação e percentual de recuperação de 0,16% e 100,1% para R_FLU e 0,14% e 100,4% para S-FLU, respectivamente. Os métodos propostos permitam a separação quantitativa dos enantiômeros de AT, MT e FLU contidos nas formas farmacêuticas analisadas, com precisão e exatidão e que podem ser aplicados no controle de qualidade enantiomérico destes fármacos. / The majority of the therapeutic agents, frequently prescribed, are formulated and commercialized as racemic mixture, even so for some of them, it has been demonstrated that the pharmacological and/or toxic effect are confined only to one of the enantiomer. Besides, it is well known that the enantiomers can present different pharmacokinetic and pharmacodynamic profiles. In the present work we selected drugs belonging to two classes of clínical importance. These pharmaceuticals are widely prescribed in clinical practice such as, the beta-blockers (atenolol, metoprolol, pindoloI, betaxolol and nadolol) and the non-steroid anti-inflammatorydrugs (ibuprofen and flurbiprofen). Several references could be found in scientific literature that describes the use of high performance liquid chromatography with chiral stationary phase (HPLC-CSP) in pharmacological studies, seldom in the quantitative determination of enantiomers in pharmaceutical formulations. It is well known that the HPLC-CSP methods offer distinct advantages over classical techniques of isomeric separation and analysis, especially for the enantiomeric separation. The direct enantiomeric separation of atenolol metoprolol nadolol and betaxolol were obtained using CSP Chiralcel OD®.The enantiomers of pindolol were separate utilizing CSP α-Burke 2® and those of ibuprofen and the flurbiprofen with CSP Whelk-O 1®. In this work are presented efficient and sensitive methods for stereospecific determination of atenolol (AT), metoprolol (MT) and flurbiprofen (FLU) in pharmaceutical formulations. The stereoselective determination of atenolol and metoprolol in pharmaceuticals was performed through validated chromatographic method. The validation of liquid chromatographic methods was done utilizing a cellulose tris- 3,5-dimethylphenyl carbamate, Chiralcel OD®, (250x4.6 mm, 10µm)as CSP. The samples were analyzed at room temperature with injection volume of 20µL and UV detection was made at 276nm. In case of atenolol, the mobile phase was constituted of hexane:ethanol:diethylamine:acetic acid (60:40:0.2:0.2 v/v), with a flow rate of 1.0 mL/min. Separate standard curve for R-AT and S-AT showed good linearity over a concentration range from 50-130 µg/mL, with coefficient of correlation of 0.9991 and 0.998, respectively. The coefficient of variation and average recovery for R-AT in the samples A, B, C, and D were 1.15% and 101.06%; 0.74% and 99.25%; 1.05% and 102.57%; 0.84% and 101.57% respectively. The coefficient of variation and average recovery for S-AT in samples A, B, C and D were 1.33% and 98.87%; 0.99% and 100.76%; 1.17% and 101.69%; 1.26% and 100.39%, respectively. In case of metoprolol, the mobile phase was constituted of hexane:ethanol:diethylamine:acetic acid (40:60:0.2:0.2 v/v), with a flow rate of 0.8 m L/min. Separate standard curve for R-MT and S-MT showed good linearity over a concentration range fIom 30-110 µg/mL, with coefficient of correlation of 0.9988 and 0.9990, respectively. The coefficient of variation and average recovery for R-MT in sample analyzed was 0.86% and 98.62% and for S-MT was 1.40% and 99.39%, respectively. A high performance liquid chromatographic method is developed and validated for enantiomeric separation and quantitative determination of FLU in pharmaceutical preparation. A WheIk-O 1® column (250x4.6 mm, 5µm)was used as chiral stationary phase (CSP). The mobile phase was constituted of hexane:ethanol:acetic acid (95:05:0.2 v/v/v), at a flow rate of 0.9 rnL/min and UV detection at 246nm. All experiments were done at ambient temperature. The S-FLU standard curve showed linearity over a concentration range from 2-18µg/mL, (R2 = 0.9993). The coefficient of variation and average recovery of R-FLU were 0.16% and 100.13% and for S-FLU were 0.14% and 100.4%; respectively. The proposed methods permits quantitative separation of AT, MT and FLU enantiomers in pharmaceutical formulations studied with precision and accuracy. The proposed validated methods can be used in the enantiomeric quality controI of referred pharmaceutical drugs.
|
Page generated in 0.0352 seconds