1 |
Avaliação da pré-carga e torque de remoção de três parafusos de pilares para próteses unitárias implantossuportadas após ciclagem mecânicaSilva, Fabrício Dorigon da January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:22Z (GMT). No. of bitstreams: 2
000422731-0.pdf: 4008244 bytes, checksum: 02ec9a1844e8d5ae7be399b6caabc500 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / This study was aimed to compare the preload and removal torque values of three types of screw for transmucosal abutment attachment to single implantsupported prosthesis submitted to cyclic loading test. Ten external hex fixtures (Conexão®, Sistemas de Prótese Ltda. , São Paulo, Brazil) were used, presenting 4,0mm in diameter and 15,0mm in length. Thirty metal crowns were cemented over the abutments Cera One® and attached with its gold, titanium and surface-treated titanium (Torq-Tite®) screws. The screws were attached and the initial preload was recorded. After crown cementation, the samples were placed in a cyclic loading machine and submitted to 400 thousand cycles and a load of 100N. After the test, the preload values were measured through a strain gauge and a measurement cell. Initial and removal torques were measured with an electronic torque control device. Gold screws exhibited the highest preload values (before cyclic 341,00±78,53 N; after cyclic 284,60±72,8 N), followed by surface-treated titanium screws (before cyclic 284,00±70,92 N; after cyclic 195,00±69,28 N) and titanium screws presented the lowest results (before cyclic 235,00±27,39 N after cyclic 196,00±29,66 N). Regarding torque removal values, titanium screws presented the highest values (21,00 ± 0,79 Ncm), followed by gold screws (18,06 ± 1,94 Ncm) and surface-treated titanium screws (16,64 ± 1,38 Ncm). After statistical analysis, ANOVA (p<0,05) e TStudent (p<0,05), significant differences were found between groups for preload, before and after cyclic loading and removal torque. Considering the results, gold screws are the most indicated samples in obtaining joint stability. / Este estudo in vitro teve como objetivo comparar os valores de pré-carga e torque de remoção de três tipos de parafusos de fixação de pilares para próteses unitárias submetidos ao teste de ciclagem mecânica. Foram utilizados 10 implantes hexágono externo (Conexão®, Sistemas de Prótese Ltda. , São Paulo, Brasil) com 4,0mm de diâmetro e 15,0mm de comprimento, nos quais foram cimentadas 30 coroas metálicas sobre abutments Cera One®, fixados com seus respectivos parafusos de ouro, titânio e titânio com tratamento de superfície (Torq-Tite®). Os parafusos foram inseridos e registrou-se a pré-carga inicial. Após cimentação das coroas, as amostras foram posicionadas na cicladora mecânica e submetidas a 400 mil ciclos com freqüência de 1 ciclo/segundo e carga de 100N. Após o teste, foi avaliado o valor de pré-carga produzido com a utilização da célula medidora de carga e extensômetros. Para mensuração dos torques de aperto e remoção, utilizou-se dispositivo eletrônico de controle de torque. Os parafusos de ouro apresentaram os maiores valores de pré-carga (pré-ciclagem 341,00±78,53 N; pós-ciclagem 284,60±72,81 N) em relação aos parafusos de titânio (pré-ciclagem 235,00±27,39 N; pós-ciclagem 196,00±29,66 N) e tratado (pré-ciclagem 284,00±70,92 N; pós-ciclagem 195,00±69,28 N). Para os valores de torque de remoção, os maiores registros foram encontrados para o grupo titânio (21,00 ± 0,79 Ncm), seguido do grupo ouro (18,06±1,94 Ncm) e tratado (16,64±1,38 Ncm). Após análise estatística, ANOVA (p<0,10) e T-Student (p<0,05), foram encontradas diferenças significativas entre os três grupos, para pré-carga, pré e pós-ciclagem e torque de remoção. Devido aos maiores valores de pré-carga obtidos nos resultados do estudo, sugere-se que os parafusos de ouro sejam os mais indicados para obtenção de estabilidade da junta pilar-implante.
|
2 |
Estudo comparativo entre a fixação interna rígida com parafuso compressivo tipo neck screw e microplacas com microparafusos nas fraturas do complexo zigomáticoOmizzolo, Guilherme January 2012 (has links)
Submitted by Ginamara Lima (ginaj@pucrs.br) on 2012-08-08T20:40:07Z
No. of bitstreams: 1
440591.pdf: 3736403 bytes, checksum: 8a5e110d9859d4c6d6a19122ed5e0f65 (MD5) / Made available in DSpace on 2012-08-08T20:40:07Z (GMT). No. of bitstreams: 1
440591.pdf: 3736403 bytes, checksum: 8a5e110d9859d4c6d6a19122ed5e0f65 (MD5) / As fraturas tetrapoides do complexo zigomático necessitam de uma exatidão na correção, além de eficiente fixação interna para se obter um bom resultado final. Almejando aprimorar as vantagens e minimizar as desvantagens das técnicas de fixação interna rígida, foi desenvolvido o parafuso neck screw. A estabilidade necessária para a correta fixação vem de um sistema de compressão dinâmica aumentando o contato entre os cotos fraturados. O presente trabalho teve como objetivos avaliar: a fixação e a estabilidade das fraturas do complexo zigomático tipo B proporcionadas pelo parafuso neck screw, aplicado na região da sutura frontozigomática e comparando com uma técnica de microplacas e microparafusos, na região da sutura frontozigomática e no bordo da região orbitária inferior; o conforto ou desconforto pós-operatórios à palpação relatados pelo paciente e o tempo cirúrgico médio empregado. Para avaliar a eficiência do parafuso neck screw, trinta pacientes com fratura tetrapoide de zigoma tiveram realizadas tomografias computadorizadas em cortes axiais e coronais para evidenciação das fraturas e planejamento cirúrgico; os pacientes foram submetidos ao procedimento cirúrgico, com osteossíntese através do parafuso neck screw e a técnica de microplaca e microparafuso na região frontozigomática, com o tempo cirúrgico registrado; após vinte e quatro horas e trinta dias foram submetidos a novo exame tomográfico. Os resultados coletados e mensurados foram submetidos a teste estatístico de Mann Whitney entre as técnicas usadas e teste T para o tempo. O ponto principal desta pesquisa está na proposição de uma técnica para a redução e fixação das fraturas-disjunção do complexo zigomático minimamente invasivo em relação às outras técnicas comparadas na literatura. A técnica com o parafuso neck screw neste trabalho garante estabilidade da fixação pelo acompanhamento tomográfico. A análise da estatística sobre as mensurações se demonstrou altamente significativa. O acompanhamento clínico dos pacientes nos apresentou ausência de assimetria facial, enoftalmo, ou diplopia; o tempo operatório é significativamente reduzido e com a observação da diminuição do desconforto referido pelos pacientes diante da palpação na região frontozigomática, pois o parafuso neck screw tem um alojamento intraósseo. / The tetraploid fractures from the zygomatic complex need accuracy in the correction and an efficient internal fixation for obtaining a good final result. Aiming at improving the advantages and minimizing the disadvantages of the rigid internal techniques, the screw "Neck Screw" was developed. The necessary stability for the correct fixation comes from a dynamic compression sistem increasing the contact between the stumps fractured. This assignment has the objectives to evaluate: the fixation and the stability of the dysjunction-fractures of the zygomatic complex provided by the screw "Neck Screw", applied in the region of the frontozygomatic suture, and to compare with a technique already devoted of micro-plaques and micro-screws applied in the region of the frontozygomatic suture and edge of inferior orbit; the after-operative confort or the disconfort reported by the pacient; the medium medical-surgical time used. To evaluate the efficiency of the screw "Neck Screw", thirty pacients with tetraploid fractures of zygoma had their computerized tomographies done on axial and coronale cuts for evidencing the fractures and for surgical planning. The pacients were subjected to the surgical procedure with osteosynthesis through the "Neck Screw" and the micro-plaque and micro-screw technique in the frontozygomatic region, having the surgical time properly noted. After 24 hours and 30 days, they were subjected to a new tomographic exam. The results gotten and measuremented were subjected to statistical tests of Mann Whitney, among the techniques used, and test T for the time. The importance of this research lies on the proposal of a technique for the reduction and fixation of the disjunction-fractures of the zygomatic complex minimally invasive in relation to the other techniques compared in the literature. The technique with the screw,"Neck Screw", guarantees stability of the fixation through the tomographic follow up. The analysis of the statistic about the measurements was revealed highly significant. The pacients' clinic follow up showed us absense of facial asymmetry, enophthalmos or diplopia. The operating time is significantly reduced and there is decrease of the disconfort reported by the pacients when palpating on the frontzygomatic region, thus the screw,"Neck screw", has an intra-osseous housing.
|
3 |
Avaliação histológica tardia da superfície óssea após a fixação de miniplacas e parafusos com diferentes ligas metálicas: estudo in vivo em ratos WistarDolzan, André do Nascimento January 2013 (has links)
Made available in DSpace on 2013-10-29T16:25:19Z (GMT). No. of bitstreams: 1
000451617-Texto+Completo-0.pdf: 638194 bytes, checksum: f2470bb81322e6a32a3d10b371e1182b (MD5)
Previous issue date: 2013 / Objective: To evaluate the histological changes of bone surface after insertion of mini-plates and screws in the bone surface. Material and methods: Eighteen rats of Wistar strain were used, a plate and two screws were inserted in the external cortex of the femur of each animal. The animals were divided into three groups of six animals each, after thirty days of completion of the procedure the implanted material was removed cirurgiacamente after euthanasia of animals, and the bone surface ready to be removed and analyzed histologically. Results: Histological evaluation after marking immunohistochemistry, Group 3, with different materials, showed an increased inflammatory infiltrate in uperfície area analyzed, which indicated a possible area of osteolysis. Groups 1 and 2 showed no statistically significant differences showing an increase of the standard normal reparative inflammation. Conclusions: The results of study indicated that the use of different materials increase the chance of encountering large areas of osteolysis in the bone surface in contact with these materials. / Objetivo: Avaliar as alterações histológicas da superfície óssea após a inserção de miniplacas e parafusos na superfície óssea. Materiais e métodos: Dezoito ratos, da linhagem Wistar, foram utilizados; Uma placa e dois parafusos de fixação foram inseridos na cortical externa do fêmur de cada animal. Os animais foram divididos em três grupos de seis animais cada, após trinta dias da realização do procedimento o material implantado foi removido cirurgicamente após a eutanásia dos animais, e a superfície óssea removida e preparada para ser analisadas histologicamente. Resultados: Na avaliação histológica, após a marcação imunohistoquímica, O grupo 3, com diferentes materiais, apresentou um aumento do infiltrado inflamatório na superfície de área analisada, que indicou uma possível osteólise da região. Os grupos 1 e 2 não apresentaram diferenças estatísticas significantes que demonstrassem um aumento do padrão normal de inflamação reparativa. Conclusões: Os resultados do trabalho indicam que o uso de diferentes materiais aumentam a possibilidade de ocorrer áreas de osteólise na superfície óssea em contato com esses materiais.
|
4 |
Avaliação histológica na interface óssea após a colocação de miniplacas e parafusos com diferentes composições metálicas: estudo in vivoAvelar, Rafael Linard January 2010 (has links)
Made available in DSpace on 2011-12-27T14:14:22Z (GMT). No. of bitstreams: 2
000428173-0.pdf: 3267525 bytes, checksum: 111e79e4715696d409dab4a83d48e6c0 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / OBJECTIVE: The aim of the present study was to assess histological alterations following the placement of miniplates and screws with different metal compositions. MATERIALS AND METHODS: Eighteen Wistar rats were divided into three groups of six animals. A miniplate and two screws were inserted on the external surface of the right femur of each animal. Six received a titanium plate and screws; six received a titanium plate and stainless steel screws; and six received a plate and screws coated with diamond-like carbon. The screws were five mm in length and inserted until the tips projected through the endosteal side. After 30 days, the miniplates and screws were removed and histological analysis was performed on the 0. 5-cm2 interface between the plate, screw and bone defect. RESULTS: A greater inflammatory process occurred in the group with different metal compositions (titanium and steel). In this same group, there was a greater presence of Howship lacunae, indicating possible osteolysis stemming from the onset of galvanic corrosion between the titanium and stainless steel. CONCLUSIONS: When using materials with different metal compositions in blood, the combination of stainless steel and titanium implants leads to a greater possibility of galvanic corrosion than when using components made from the same materials for fixation purposes. / OBJETIVO: Avaliar as alterações histológicas ósseas superficiais após a inserção de miniplacas e parafusos com diferentes composições metálicas. MATERIAL E METODOS: Dezoito ratos, da linhagem Wistar, foram utilizados. Uma miniplaca e dois parafusos foram inseridos na superfície externa do fêmur direito de cada animal. Todos os parafusos foram de 5,0 mm de comprimento e foram inseridos até as pontas serem projetadas pelo lado endosteal. Os animais foram divididos em três grupos com seis animais cada. Nos primeiros seis animais foram colocados uma placa e dois parafusos de titânio, em outros seis animais foram colocados uma placa de titânio e dois parafusos de aço inoxidável, e nos animais restantes foram colocados placa e parafuso revestido com Diamond-Like Carbon (DLC). Após 30 dias da realização do procedimento cirúrgico, as miniplacas e os parafusos foram retirados e foram feitas avaliações histológicas na interface placa parafuso no defeito ósseo, em uma extensão de 0,5 cm2.RESULTADOS: Na avaliação histológica observou-se um maior processo inflamatório no grupo com diferentes composições metálicas (Grupo titânio-aço)(p=0,204), como também uma maior presença de lacunas de Howship que indicam uma possível osteólise em decorrência de um ínicio de corrosão galvânica entre o titânio e o aço inoxidável (p=0. 002).CONCLUSÕES: Os resultados deste estudo indicam que, quando usamos diferentes materiais com diferentes composições metálicas, os componentes de implantes de aço inoxidável quando em associação com o titânio têm uma maior suscetibilidade à provocar osteólise do que quando se utilizam os mesmos componentes como materiais de fixação.
|
5 |
Fixação rígida com parafuso tipo Neck Screw em fraturas tetrapóides de zigomaGaziri, Daniel Augusto January 2007 (has links)
Made available in DSpace on 2011-12-27T14:14:28Z (GMT). No. of bitstreams: 2
000401402-0.pdf: 4392102 bytes, checksum: d7e7f2454fdc493ea1493ea0304feae2 (MD5)
license.txt: 581 bytes, checksum: 44ea52f0b7567232681c6e3d72285adc (MD5) / Correct reduction of the tetrapod zygoma fractures and their efficient internal fixation are essential to achieve a good outcome. In this work we developed a type of “neck screw” which improves some advantages of the techniques of rigid internal fixation and minimizes some of their disadvantages. The “neck screw” increases friction between the fractured bone segments, in axial direction, thereby promoting the required stability and adequate bone repair. We evaluated the setting and stabilization of disjunction-fractures of the zygomatic complex corrected by the “neck screw” applied in the region of frontozygomatic butters, the post-surgery comfort or discomfort reported by patients, and the average surgery time spent. To evaluated the efficiency of the “neck screw”, four patients with tetrapod fracture of zygoma were submitted to computed tomography scans for displaying their fractures and guiding surgical planning, were them subjected to surgical osteosynthesis with the “neck screw” applied in the region of the frontozygomatic suture, the surgery time was recorded, and after thirty days new computed tomography images were taken. The patients were evaluated by physical examinations, application of the discomfort questionnaire about the presence of the “neck screw”, and their computed tomography images were processed by the protocol of measurement. Data collected on the questionnaires, the surgical time and diversion of bone segments were subjected to statistical tests. The surgical correction of the tetrapod zygomatic fractures here proposed has the following advantages: it has a lower cost, since it uses only one titanium screw, whereas current methods employ at least one microplate and four screws; the surgery time is shorter than the time spent by the current techniques; it ensures stability of fixation, as evidenced by computed tomography scans and by clinical monitoring of patients, since none of them presented facial asymmetry, enophthalmus, or diplopia; discomfort reported by patients is reduced because the head screw is lodged into the bone. / A correta redução das fraturas tetrapóides do zigoma e sua eficiente fixação interna são primordiais para se obter um bom resultado final. Buscando aprimorar as vantagens e minimizar as desvantagens das técnicas de fixação interna rígida, desenvolvemos o parafuso neck screw, conciliando a técnica do lag screw à das placas minicompressivas. Seu sistema de compressão dinâmica visa aumentas a fricção entre os segmentos ósseos fraturados, no sentido axial, promovendo a estabilidade necessária, para o correto reparo ósseo. O presente trabalho teve como objetivos avaliar: a fixação e a estabilização das fraturas-disjunção do complexo zigomático proporcionadas pelo parafuso neck screw, aplicado na região da sutura frontozigomática; o conforto e/ou desconforto pós-operatórios relatados pelo paciente; o tempo cirúrgico médio empregado. Para avaliar a eficiência do parafuso neck screw, quatro pacientes com fratura tetrapóide de zigoma tiveram realizadas tomografias computadorizadas para evidenciação das fraturas e planejamento cirúrgico; em seguida foram submetidos a procedimento cirúrgico, com osteossíntese através do neck screw aplicado na região da sutura frontozigomática, com o tempo cirúrgico devidamente anotado; após trinta dias foram forma submetidos a novo exame tomográfico. Os pacientes foram avaliados através de exame físico, aplicação de questionário e mensuração das imagens tomográficas, e os dados coletados, a respeito, foram submetidos a testes estatísticos. A importância desta pesquisa esta na proposição de uma rotina de técnica para fixação das fraturas-disjunção do complexo zigomático. O método proposto garante estabilidade da fixação comprovada pelo acompanhamento tomográfico, com análise estatística das mensurações altamente significante e também pelo acompanhamento clínico dos pacientes, que não apresentaram assimetria facial, enoftalmo, ou diplopia; o tempo operatório é significativamente reduzido e há diminuição do desconforto referido pelos pacientes quando da palpação na região frontozigomática, pois o parafuso neck screw teve alojamento intra-ósseo. Esta técnica tem menor custo, por utilizar apenas um parafuso, enquanto o método tradicional emprega, no mínimo, uma microplaca e quatro parafusos.
|
Page generated in 0.0402 seconds