• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 864
  • 15
  • 9
  • 8
  • 8
  • 8
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 890
  • 552
  • 358
  • 161
  • 159
  • 157
  • 155
  • 126
  • 122
  • 114
  • 111
  • 106
  • 100
  • 90
  • 87
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tratamento cirúrgico das fraturas zigomáticas, utilizando-se de miniplacas e parafusos do sistema de 1,5mm : estudo clínico-radiográfico em humanos /

Hasse, Paulo Norberto. January 2003 (has links)
Orientador: Idelmo Rangel Garcia Júnior / Banca: Eduardo Hochuli Vieira / Banca: Edevaldo Tadeu Camarini / Resumo: As fraturas do complexo zigomaticomaxilar figuram dentre os traumatismos mais incidentes no arcabouço facial. Baseado na complexidade e grande variedade de diagnóstico e tratamentos relatados, foi proposta desse trabalho avaliar, clinica e radiograficamente, fraturas zigomáticas unilaterais, tratadas através de fixação interna rígida, com miniplacas e parafusos de 1,5mm. Foram analisados 15 pacientes com fraturas unilaterais do complexo zigomaticomaxilar, comparados a 15 pacientes sem fraturas, para que fosse realizada análise comparativa da área e perímetro das cavidades orbitárias, bem como da distância do dorso nasal à proeminência zigomática entre ambos os grupos. Quando comparados os dados dos pacientes portadores de fraturas e os sadios, observou-se que as diferenças não foram estatisticamente significantes. / Abstract: The fractures of the zygomaticmaxillary complex represents among the most incident traumatisms in the facial outline. Based on the complexity and great diagnosis variety and reported treatments, the purpose of this study was to evaluating clinical-radiographic zygomatic unilateral fractures, treated through internal rigid fixation with 1.5mm miniplates and screws. Fifteen patients with unilateral zygomaticmaxillary complex fractures were compared to fifteen patients without fractures, so that it was accomplished comparative analysis of the area and perimeter of the orbital cavities, as well as of the distance of the nasal back to the zygomatic prominence between both the groups. When compared the treated patients' data and the healthy ones, it was observed that the differences were not statistically significant. / Mestre
2

Efeito da pré-deformação e Shot Peening na tenacidade à fratura e propagação de trinca por fadiga da liga de alumínio 7475-T7351, de aplicação aeronáutica.

Barroso, Emerson Kellem Lana January 2004 (has links)
Programa de Pós-Graduação em Engenharia de Materiais. Rede Temática em Engenharia de Materiais, Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal de Ouro Preto. / Submitted by Marise Leite (marise_mg@yahoo.com.br) on 2016-03-02T14:13:44Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) DISSERTAÇÃO_EfeitoPrédeformaçãoShot.pdf: 13622044 bytes, checksum: dab3ed14a28433d0b45e8456ed494120 (MD5) / Approved for entry into archive by Oliveira Flávia (flavia@sisbin.ufop.br) on 2016-04-11T14:12:48Z (GMT) No. of bitstreams: 2 DISSERTAÇÃO_EfeitoPrédeformaçãoShot.pdf: 13622044 bytes, checksum: dab3ed14a28433d0b45e8456ed494120 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-04-11T14:12:49Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO_EfeitoPrédeformaçãoShot.pdf: 13622044 bytes, checksum: dab3ed14a28433d0b45e8456ed494120 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2004 / As ligas de alumínio são largamente utilizadas em projetos aeronáuticos em função da boa resistência mecânica associada com sua baixa densidade. Dentre elas, a liga 7475-T7351 é utilizada devido ao seu bom comportamento em termos de propagação de trinca de fadiga e seus elevados valores de tenacidade à fratura. Os efeitos da pré-deformação e shot peening na propagação de trinca por fadiga e tenacidade à fratura dessa liga foram investigados. Ensaios com amplitude constante foram realizados para duas razões de tensão R objetivando também mostrar os efeitos dessa variável no comportamento do material. Os resultados mostram que, tanto a resistência à propagação de trinca de fadiga quanto a tenacidade à fratura do material, diminuem na medida em que se aumenta a quantidade de pré-deformação. O mesmo efeito é observado para o aumento da razão de tensão R. Por outro lado, o tratamento por shot peening mostrou ser efetivo para a melhoria das características estudadas. Em relação à propagação de trinca, os efeitos da pré-deformação e do shot peening foram mais pronunciados para a região do limiar ΔKth. Apesar da diferença do comportamento para essas condições, não foi observada mudança significativa na microestrutura do material. O material apresentou fratura dúctil típica das ligas de alumínio, com alvéolos associados com inclusões, algumas vezes fraturadas por deformação. A propagação da trinca de fadiga ocorreu de forma transgranular em toda a extensão do corpo-de-prova, apresentando bifurcação para velocidades de propagação correspondentes à região linear da curva da/dN x ΔK, e aspecto mais plano na região do limiar ΔKth. Na região do limiar ΔKth a superfície de fratura apresentou platôs alongados e, na região de transição, a superfície de fratura foi mais plana, com o aparecimento de estrias de fadiga e bifurcações de trincas. A região superficial da amostra tratada por shot peening apresentou um típico travamento de trincas por tensões compressivas. Os modelos de Paris-Erdogan e Collipriest foram empregados e os resultados experimentais mostraram uma boa concordância com os mesmos. A aplicação do modelo de Collipriest confirma a sua relevância, principalmente quando reduções de peso e de custos são considerações importantes de projeto. Além disso, os valores ΔKth encontrados mostraram grande concordância com o mesmo. Este modelo também apresenta uma característica menos conservativa par a região do limiar ΔKth, em relação ao modelo de Paris-Erdogan, no entanto sem comprometer os aspectos de segurança. Além disso, o modelo de Collipriest apresenta recursos matemáticos para ajustar os dados com grande confiabilidade. ____________________________________________________________________________________ / ABSTRACT: Aluminum alloys are widely used in aeronautical designs due to their good mechanical strength associated with low-density values. Among them, the 7475-T7351 alloy is used due to its good fatigue crack propagation behavior and high fracture toughness values. The effects of pre-strain and shot peening on the fatigue crack propagation and fracture toughness of this alloy were investigated. Constant amplitude tests were also performed for two stress ratio in order to show the effects of this variable on the material behavior. The results show that both fatigue crack propagation resistance and fracture toughness decrease when the pre-strain is increased. The same effect is observed with the increasing of stress ratio R. On the other hand, shot peening treatment showed to be effective to improve the characteristics evaluated. Regarding the crack propagation, the effects of pre-strain and shot peening were more pronounced for the ΔKth region. In spite of the differences in the behavior for this condition, it was not observed significant change in the microstructure of material. The material presented typical ductile fracture of aluminum alloys, with dimples associated with inclusions, sometimes fractured by deformation. The fatigue crack propagation was transgranular in the whole extension of specimen, showing bifurcation to propagation in rates corresponding to the region of linear propagation in the da/dN curve, and also more flat aspect in the ΔKth region. At the ΔKth region, the fracture surface presented elongated plateaux and at the transition region the fracture was more plane, with the emergence of fatigue striation and crack bifurcation. The superficial region of specimen treated by shot peening presented a typical crack restrain by compressive stresses. Paris-Erdogan and Collipriest models were used and the experimental results showed a good agreement with them. The use of the Collipriest model confirms its relevance to aeronautical designs, mainly when weight and costs reduction are important design considerations. Beside that, the values of ΔKth found showed a good agreement with the model. This model also presents a less conservative characteristic at ΔKth region, in relation to the Paris-Erdogan model, however without jeopardizing the safety aspects. Furthermore, the Collipriest model presents mathematical resources to adjust data with high reliability.
3

Comparison of nickel-titanium rotary systems longevity using a new mathematical analysis platform (M.A.P.E.R) = Comparação da longevidade de sistemas rotatórios de níquel-titânio utilizando uma nova plataforma de análise matemática (M.A.P.E.R.) / Comparação da longevidade de sistemas rotatórios de níquel-titânio utilizando uma nova plataforma de análise matemática (M.A.P.E.R.)

Gomes, Nilton Vivacqua, 1977- 11 December 2012 (has links)
Orientador: Francisco José de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T20:11:59Z (GMT). No. of bitstreams: 1 Gomes_NiltonVivacqua_D.pdf: 1924416 bytes, checksum: f0bbe9ce05b0592e2936526ba662b4db (MD5) Previous issue date: 2012 / Resumo: Apesar de a instrumentação mecanizada agregar velocidade e qualidade ao tratamento endodôntico, a não utilização rotineira da mesma pelos endodontistas se deve, em parte, ao custo proveniente das trocas constantes de limas, na intenção de prevenir as fraturas que acometem os sistemas de instrumentação rotatória. Assim, no intuito de minimizar esse problema, torna-se necessário o desenvolvimento de sequências e/ou sistemas que permitam uma margem de segurança maior em relação à fratura. No Capítulo 1 deste estudo, o objetivo foi comparar 15 sistemas de instrumentação rotatória através de um método matemático desenvolvido pelo autor, utilizando o programa Microsoft Excel. Nomeado de "Plataforma de Análise Matemática da Taxa de Alargamento de Canais Radiculares" (M.A.P.E.R.), esse modelo matemático foi usado para calcular a taxa de alargamento, a força e as pressões de cisalhamento atuantes em cada meio milímetro dos instrumentos de todos os sistemas testados, auxiliando na criação de uma nova sequência seguindo a melhor distribuição de tensões possível (nomeada de RS6, Rotatório com Segurança utilizando 6 instrumentos), a qual servirá como parâmetro de comparação. Nesta plataforma, foram inseridos dados de formato, sequência, penetração e torque de cada instrumento, sendo possível assim, calcular essas tensões exercidas em cada um, além de identificar os mais susceptíveis à fratura. Então, 350 molares superiores e inferiores, com curvaturas de raízes até 35º, foram instrumentados por 8 jogos, todos apenas da nova sequência RS6, avaliando a longevidade dos instrumentos nesta nova técnica. A sequência RS6, desenvolvida pelo autor com instrumentos K3 e reduzida ação de forças e pressões de cisalhamento, alcançou uma média de 116,1 condutos instrumentados até a ruptura, corroborando com os valores da plataforma. Analisando os resultados, podemos concluir que a plataforma matemática foi capaz de simular as forças e pressões envolvidas no funcionamento de cada lima em todas as sequências testadas. No Capítulo 2, um método in vitro em dentes humanos extraídos foi utilizado. A nova sequência foi então comparada a outras duas já utilizadas na plataforma matemática (ProTaper e Prodesign), em 200 molares, até a fratura de todos os instrumentos em duplicata. O número de condutos instrumentados por cada lima foi anotado e comparado com as informações calculadas pela plataforma. Na maioria dos casos, a separação ocorreu próxima do ponto de maior concentração de forças nos instrumentos. A sequência RS6, recém projetada, apresentou novamente os melhores resultados, quando comparada às outras duas, com uma média de 110,0 (a) condutos até a fratura, contra 78,5 (b) da ProDesign e 46,6 (c) da ProTaper (p<0,05). Concluindo, a sequência RS6, permitiu a reutilização dos instrumentos com grande segurança, protelando a fratura dos mesmos / Abstract: The rotary instrumentation adds speed and quality to the endodontic treatment; however it is not routinely used. The endodontists are cautious on having the mechanized instrumentation as a resource, due to the cost of constant file reposition that is necessary to avoid the fractures that the systems constantly suffer while using this process. Thus, it is important to develop sequences and/or systems that allow a greater safety margin regarding these fractures. The aim of the first part of this study is to make the comparison of 15 rotary instrumentation systems through a mathematical method, which uses the Microsoft Excel program, developed by author. The mathematical model - named "Mathematical Analysis Platform of Enlargement Rate" (M.A.P.E.R.) - was used to calculate the rate of enlargement, strength and shearing pressure exerted in each half millimeter of the instruments in each one of the tested systems, which aided the creation of a new sequence - named RS6 (Rotary with Safety using 6 files) - that follows the best stress distribution as possible; hence, the RS6 became a benchmark. In this platform, we inserted the data of the shape, sequence, penetration and torque of each instrument, so it was possible for us to calculate the stresses exerted on each of the data and, thereby, identify the ones that are most likely to fracture. Then, to assess the longevity of the instruments using this new technique, 350 maxillary and mandibular molars with until 35? degrees of root canal curvatures were instrumented by 8 matches of this new RS6 sequence. The new developed sequence, RS6 with K3 files, presented the action of forces and shearing pressures reduced, and reached an average of 116.1 root canals instrumented until rupture, which corroborates with the values of the platform. Analyzing the results, we can conclude that the mathematical platform was able to simulate the forces and pressures involved in the functioning of each file, in all the sequences tested. In the second part of this study, we used an in vitro method on extracted human teeth. The new sequence was then compared to the other two previously used in the mathematical platform (ProTaper and ProDesign) in 200 molars, until the fracture of all instruments in duplicate. The number of root canals instrumented by each file was recorded and compared to the information calculated by the platform. In most instances, the separation occurred near the point of highest concentration of forces in the instruments. Once again, the newly designed sequence, RS6, showed the best results when compared to the other two. With an average of 110.0 (a) root canals until fracture, counter 78.5 (b) from the ProDesign and 46.6 (c) from the ProTaper (p <0.05). In conclusion, the sequence RS6 allowed the reuse of the instruments with great safety, avoiding their fracture / Doutorado / Endodontia / Doutor em Clínica Odontológica
4

Estudo da reprodutibilidade intra e interobservador das classificações de Frykman, AO e universal para as fraturas distais do radio

Oliveira Filho, Osvaldo Mendes de, 1964- 27 February 2003 (has links)
Orientador: William Dias Belangero / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T18:21:23Z (GMT). No. of bitstreams: 1 OliveiraFilho_OsvaldoMendesde_M.pdf: 975603 bytes, checksum: baee5af490bde08ee070656e702ecf8e (MD5) Previous issue date: 2003 / Resumo: Existem inúmeras classificações para as fraturas da extremidade distal do rádio e todas são abertas para interpretações pessoais ( JOHNSTONE et al., 1993 ). Dessa forma, para ser bem aceita e utilizada para comparação de diferentes séries, qualquer classificação deve ter uma boa reprodutibilidade intra e interobservador. Neste estudo foram selecionadas 40 radiografias de fraturas distais do rádio que foram classificadas por ortopedistas de centros e nível de experiências diferentes, sendo alguns ligados a instituições universitárias e outros não, com o objetivo de determinar o grau de reprodutibilidade intra-observador e interobservador das classificações de Frykman, AO e Universal empregando-se o método estatístico Kappa. Além disso, verificar se a proporção de concordância melhora com os observadores de maior experiência.As classificações foram avaliadas, à princípio, sem simplificações e foi observada concordância intra-observador média moderada para as classificações de Frykman e Universal e leve para o sistema AO.A média de reprodutibilidade interobservador foi leve nas duas leituras para as classificações de Frykman e Universal e desprezível na segunda leitura para a classificação AO.Houve melhora do índice de concordância intra-observador entre os observadores com mais experiência, o que não acorreu com a reprodutibilidade interobservador.Todas as classificações utilizadas apresentaram reprodutibilidade interobservador questionável, comprometendo o uso dos três sistemas avaliados / Abstract: There are numberless classifications to the fractures of the extremity of the distal radius and all of them are open to personal interpretation ( Jonhstone et al., 1993 ). In order to be well accepted and used to the comparison of different series, any classification must, however, have a good intra and interobserver reproducibility.In this study, 40 radiographs of fractures of the distal radius were selected and classified by orthopedists of different centers and levels of experience, with the purpose of determining the intra-observer and interobserver reproductive degree of Frykman, AO and Universal classification using Kappa statistic method. The medium intra-observer concordance observed was moderate to Frykman and Universal classifications and light to the AO system.The medium interobserver reproducibility was light in the two readings to Frykman and Universal classifications and despicable in the second reading of the AO classification.All the classifications used presented questionable interobserver reproducibility compromising the use of the three evaluated systems / Mestrado / Medicina Interna / Mestre em Ciências Médicas
5

Conformabilidade plastica de fios capilares de ouro na trefilação

Zavaglia, Cecília Amélia de Carvalho, 1954- 24 August 1988 (has links)
Orientador: Ettore Bresciani Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-16T20:08:12Z (GMT). No. of bitstreams: 1 Zavaglia_CeciliaAmeliadeCarvalho_D.pdf: 11187327 bytes, checksum: 1e25a5d6da305701d7f3b8cb258653ec (MD5) Previous issue date: 1988 / Resumo: Este trabalho tem COIID principal objetivo estudar a conformabilidade na trefilação de fios capilares de ouro. Associando-se os conhecimentos sobre a mecânica da conformação, sobre as propriedades do material e sobre os critérios de fratura dúctil, pode-se estabelecer critérios de conformabilidade. A primeira etapa deste trabalho consistiu no desenvolvimento de equipamentos e dispositivos para a obtenção de fios capilares por trefilação. Na segunda etapa foram estudados os mecanismos de fratura dúctil na trefilação de fios de ouro e foram estabelecidos critérios de conformabilidade. Esses critérios foram aplica dos às condições de processamento adotadas neste trabalho. Algumas sugestões foram feitas visando minimizar a ocorrência de rupturas. / Abstract: The main goal of this work is to study workability of u1trafine gold wires in wiredrawing. Putting together the fundamentals of Irechanical plasticity, material properties and ductile fracture criteria , it may be established the workability criteria. The first part of this work involved the development of drawing machines. The second part was the study of the ductile fracture mechanisms of the wires and the establishement of workability criteria , which were applied to the process conditions of this work. Some suggestions were done in order to avoid wire breaks. / Doutorado / Doutor em Engenharia Mecânica
6

Desenvolvimento osseo de tibias e femures, quanto ao comprimento, massa, volume e densidade, em aves (Gallus gallus L.) submetidas a fraturas da tibia durante o periodo de crescimento

Ribeiro, Ricardo Fonseca, 1933- 18 July 2018 (has links)
Tese (livre docencia) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-07-18T02:11:29Z (GMT). No. of bitstreams: 1 Ribeiro_RicardoFonseca_LD.pdf: 1106615 bytes, checksum: a91f7ecf979f4a788bb3b116b561c2cd (MD5) Previous issue date: 1988 / Resumo: A finalidade do presente trabalho foi a de quantificar, ao término do crescimento ósseo, aos 113 dias de vida, as alterações de comprimento, massa, volume e densidade de tíbias e fêmures de pintos machos que haviam sido objeto de fratura de tibia, no terço médio da diáfise, aos 21 dias de idade. As aves com fratura foram divididas em três grupos: com fratura à direita (D), com fratura ã esquerda (E) e com fratura bilateral (B). Um quarto grupo incluiu aves que não sofreram fratura, para fins de controle (C). Para a medida de volume, ideou-se e construiu - se um aparelho que é minuciosamente descrito. Dos resultados das análises realizadas merecem destaque os seguintes: 1. nos grupos D e E, a massa e o volume das tíbias, no lado' fraturado, foram maiores do que no lado não fraturado, enquanto, nos fêmures, tendeu a ocorrer o oposto; 2. o prejuízo, no desenvolvimento corporal das aves com fraturas, provavelmente atribuível à dificuldade de acesso ao alimento, ocorreu menos nos segmentos ósseos estudados do que no corpo globalmente; 3. nos grupos D e E, o desenvolvimento do volume e da massa das tíbias e dos fêmures se processou em proporções aproximadamente iguais, fazendo com que a densidade esses ossos não difira apreciavelmente da dos controles correspondentes. Nos ossos do grupo B, o desenvolvimento da massa foi proporcionalmente maior do que o do volume, resultando densidade que supera a dos controles e dos fraturados, monolateralmente correspondentes / Abstract: The idea of the present research was to quantify, at the final growth of bones, the alterations of lenghtening, weight, volume and density of tibiae and femurs.: ofc male chickens. At the age of 21 days their tibiae were broken at the middle third of the diaphysis and they were sacrified at 113 days af life. The chickens were divided into three groups: D-fracture of the right. side; E - fracture of the left side ; B-bilateral fracture. A fourth group was used without fractures for comparison - C. To measure the volume was designed and built an apparatus which is described in detail. Of the results af the analysis deserve consideration the following: 1. in the groups D and E the weight and volume of tibiae of the fractured side were larger than on the unfractured, while on the femurs tended to occur the opposite; 2. the prejudice of the body development of the birds wrth fractures, probably due to the difficulty of having access to the food occurred with 1ess magnitude at the bones studied than at the body as a whole. 3. 1n the groups D and E the volume and weight of tibiae and femurs developed in approximately equal proportions. As a result, the density of these bones does not differ appreciably from the corresponding controls. In the banes of group B the development of the weight was proportionally larger than the volume. As a result, the density was higher than the contraIs and of the corresponding fractured of one side / Tese (livre docencia) - Univer / Livre-docente em Ciencias Medicas
7

Análise da mecânica da fratura elasto plástico

Dias, Acires January 1983 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Mecânica. / Made available in DSpace on 2012-10-15T22:23:15Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T14:35:19Z : No. of bitstreams: 1 180952.pdf: 11803187 bytes, checksum: cc492f29f2cc2c5a19ad301122feebee (MD5)
8

Análise numérica de problemas de fratura elástica e elastoplástica

Jorge, Paulo Roberto January 1993 (has links)
Este trabalho apresenta o método dos elementos finitos em conjunto com métodos numéricos especificos para a solução de problemas de fratura. Esta é uma poderosa ferramenta para a análise de fraturas e soluções confiáveis são obtidas para problemas complexos de Engenharia tanto no campo linear como no não-linear. O elemento finito. implementado é do tipo isoparamétrico quadrâtico da família Serendipity. Com dois graus de liberdade por nó, permite discretizar em estado plano de tensão ou deformação estruturas com geometrias bastante variadas. Para a análise linear são implementadas quatro técnicas consagradas para a avaliação do fator de intensidade de tensão no modo I de fratura: extrapolação de doslocamentos (usando malha somente com elementos convencionais e malha mesclada com elementos especiais), taxa de liberação de energia de defermação, extensão virtual da trinca e o método da integral J, descartando-se neste caso a hipótese de descarregamento. A linguagem de programação adotada é o FORTRAN 77. A entrada de dados é feita por intermédio de arquivos previamente preparados. Os resultados obtidos são confrontados com resultados experimentais e computacionais fornecidos por outros programas. Analisam-se placas, estruturas de uso na indústria e simulam-se ensaios como o corpo de prova de flexão em três pontos e o corpo de prova de tensão. compacto.
9

Modelagem da formação e propagação de trincas em misturas betuminosas através do método dos elementos finitos

Freitas, Felipe Araújo Colares de 12 1900 (has links)
FREITAS, F. A. C. Modelagem da formação e propagação de trincas em misturas betuminosas através do método dos elementos finitos. 2002. 76 f. Dissertação (Mestrado em Engenharia de Transportes) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2002. / Submitted by Zacarias Barbosa Matias Junior (zaca@det.ufc.br) on 2013-05-24T18:53:45Z No. of bitstreams: 1 2002_dis_facfreitas.pdf: 3621015 bytes, checksum: 8fab56916331e610da9479553c6357f1 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2013-05-28T13:11:53Z (GMT) No. of bitstreams: 1 2002_dis_facfreitas.pdf: 3621015 bytes, checksum: 8fab56916331e610da9479553c6357f1 (MD5) / Made available in DSpace on 2013-05-28T13:11:53Z (GMT). No. of bitstreams: 1 2002_dis_facfreitas.pdf: 3621015 bytes, checksum: 8fab56916331e610da9479553c6357f1 (MD5) Previous issue date: 2002-12 / Cracking in the asphaltic layers has been pointed out as the major pavement distress in Brazilian roadways. Typically, no consideration for the material heterogeneity has been given on previous studies. This work presents a numerical method of analysis, based on the theoryof fracture mechanics, in which the asphaltic mixture is considered heterogeneous. The binder and the aggregates are treated as separate elements. The simulations performed can be verified and calibrated with simple and conventional laboratory tests. The study investigates crack formation and evolution under monotonic loading. Nevertheless, it also outlines a new method of analysis for fatigue of asphaltic mixtures. It is also discussed the use of a multiscale methodology, in which the damage due to cracking in the local scale can be considered in a global analysis at the actual pavement scale. / O trincamento das camadas asfálticas de revestimento (capa e binder) em pavimentos flexíveis é apontado como o principal defeito das rodovias brasileiras. Estudos experimentais e numéricos sobre este fenômeno vêm sendo realizados considerando o material como homogêneo. Este trabalho apresenta uma abordagem numérica baseada na Teoria da Mecânica da Fratura na qual considera-se a heterogeneidade do material, sendo o ligante e os agregados tratados separadamente. As simulações realizadas são verificadas e calibradas através de ensaios laboratoriais simples e convencionais. O estudo trata da formação e propagação de trincas sob carregamentos monotônicos e aponta para uma nova forma de simulação do fenômeno de fadigade misturas. É ainda discutida a utilização de uma abordagem multi -escala, na qual o dano observado na forma da propagação de trincas na escala local pode ser considerado numa escala global compatível com o pavimento real.
10

Análise numérica de problemas de fratura elástica e elastoplástica

Jorge, Paulo Roberto January 1993 (has links)
Este trabalho apresenta o método dos elementos finitos em conjunto com métodos numéricos especificos para a solução de problemas de fratura. Esta é uma poderosa ferramenta para a análise de fraturas e soluções confiáveis são obtidas para problemas complexos de Engenharia tanto no campo linear como no não-linear. O elemento finito. implementado é do tipo isoparamétrico quadrâtico da família Serendipity. Com dois graus de liberdade por nó, permite discretizar em estado plano de tensão ou deformação estruturas com geometrias bastante variadas. Para a análise linear são implementadas quatro técnicas consagradas para a avaliação do fator de intensidade de tensão no modo I de fratura: extrapolação de doslocamentos (usando malha somente com elementos convencionais e malha mesclada com elementos especiais), taxa de liberação de energia de defermação, extensão virtual da trinca e o método da integral J, descartando-se neste caso a hipótese de descarregamento. A linguagem de programação adotada é o FORTRAN 77. A entrada de dados é feita por intermédio de arquivos previamente preparados. Os resultados obtidos são confrontados com resultados experimentais e computacionais fornecidos por outros programas. Analisam-se placas, estruturas de uso na indústria e simulam-se ensaios como o corpo de prova de flexão em três pontos e o corpo de prova de tensão. compacto.

Page generated in 0.03 seconds