• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 7
  • 7
  • 7
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Optical Fiber Tip Pressure Sensor

Wang, Xingwei 10 November 2004 (has links)
Miniature pressure sensors which can endure harsh environments are a highly sought after goal in industrial, medical and research fields. Microelectromechanical systems (MEMS) are the current methods to fabricate such small sensors. However, they suffer from low sensitivity and poor mechanical properties. To fulfill the need for robust and reliable miniature pressure sensors that can operate under high temperatures, a novel type of optical fiber tip sensor only 125μm in diameter is presented in this thesis. The essential element is a piece of hollow fiber which connects the fiber end and a diaphragm to form a Fabry-Pérot cavity. The all-fused-silica structure fabricated directly on a fiber tip has little temperature dependence and can function very well with high resolution and accuracy at temperatures up to 600 °C. In addition to its miniature size, its advantages include superior mechanical properties, biocompatibility, immunity to electromagnetic interference, disposability and cost-effective fabrication. The principle of operation, design analysis, fabrication implementation and performance evaluation of the sensor are discussed in detail in the following chapters. / Master of Science
2

Miniature fiber-optic multicavity Fabry-Perot interferometric biosensor

Zhang, Yan 22 December 2005 (has links)
Fiber-optic Fabry-Perot interferometric (FFPI) sensors have been widely used due to their high sensitivity, ease of fabrication, miniature size, and capability for multiplexing. However, direct measurement of self-assembled thin films, receptor immobilization process or biological reaction is limited in the FFPI technique due to the difficulty of forming Fabry-Perot cavities by the thin film itself. Novel methods are needed to provide an accurate and reliable measurement for monitoring the thin-film growth in the nanometer range and under various conditions. In this work, two types of fiber-optic multicavity Fabry-Perot interferometric (MFPI) sensors with built-in temperature compensation were designed and fabricated for thin-film measurement, with applications in chemical and biological sensing. Both the tubing-based MFPI sensor and microgap MFPI sensor provide simple, yet high performance solutions for thin-film sensing. The temperature dependence of the sensing cavity is compensated by extracting the temperature information from a second multiplexed cavity. This provides the opportunity to examine the thin-film characteristics under different environment temperatures. To demonstrate the potential of this structure for practical applications, immunosensors were fabricated and tested using these structures. Self-assembled polyelectrolytes served as a precursor film for immobilization of antibodies to ensure they retain their biological activity. This not only provides a convenient method for protein immobilization but also presents the possibility of increasing the binding capacity and sensitivity by incorporating multilayers of antibodies into polyelectrolyte layers. The steady-state measurement demonstrated the surface concentration and binding ratio of the immunoreaction. Analysis of the kinetic binding profile provided a fast and effective way to measure antigen concentration. Monitoring the immunoreaction between commercially available immunoglobulin G (IgG) and anti-IgG demonstrated the feasibility of using the MFPI sensing system for immunosensing applications. / Ph. D.
3

Fiber Optic Pressure Sensor Fabrication Using MEMS Technology

Chen, Xiaopei 27 May 2003 (has links)
A technology for fabricating fiber optic pressure sensors is described. This technology is based on intermediate-layer bonding of a fused silica ferrule to a patterned, micro-machined fused silica diaphragm, providing low temperature fabrication of optical pressure sensor heads that can operate at high temperature. Fused silica ferrules and fused silica diaphragms are chosen to reduce the temperature dependence. The fused silica diaphragms have been micro-machined using wet chemical etching in order to form extrinsic Fabry-Perot (FP) interferometric cavities. Sol-gel is used as an intermediate-layer for both fiber-ferrule bonding and ferrule-diaphragm bonding at relatively low temperature (250 °C). The pressure sensors fabricated in the manner can operate at temperatures as high as 600 °C. The self-calibrated interferometric-intensity-based (SCIIB) technology, which combines fiber interferometry and intensity-based sensing method into a single sensor system, is used to test and monitor the pressure sensor signal. The light returned from the FP cavity is split into two channels. One channel with longer coherence length can test the effective interference generated by the FP cavity, while the other channel with shorter coherence length can get signal proportional only to the source power, fiber attenuation, and other optical losses. The ratio of the signals from the two channels can compensate for all unwanted factors, including source power variations and fiber bending losses. [11] / Master of Science
4

Spectro-imagerie optique à faible flux et comparaison de la cinématique Ha et HI d'un échantillon de galaxies proches

Daigle, Olivier 02 1900 (has links)
Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques. / A new EMCCD (Electron multiplying Charge Coupled Device) controller is presented. It allows the EMCCD to be used for photon counting by drastically taking down its dominating source of noise : the clock induced charges. A new EMCCD camera was built using this controller. It has been characterized in laboratory and tested at the observatoire du mont Mégantic. When compared to the previous generation of photon counting cameras based on intensifier tubes, this new camera renders the observation of the galaxies kinematics with an integral field spectrometer with a Fabry-Perot interferometer in Ha light much faster, and allows fainter galaxies to be observed. The integration time required to reach a given signal-to-noise ratio is about 4 times less than with the intensifier tubes. Many applications could benefit of such a camera: fast, faint flux photometry, high spectral and temporal resolution spectroscopy, earth-based diffraction limited imagery (lucky imaging), etc. Technically, the camera is dominated by the shot noise for flux higher than 0.002 photon/pixel/image. The 21 cm emission line of the neutral hydrogen (HI) is often used to map the galaxies kinematics. The extent of the distribution of the neutral hydrogen in galaxies, which goes well beyond the optical disk, is one of the reasons this line is used so often. However, the spatial resolution of such observations is limited when compared to their optical equivalents. When comparing the HI data to higher resolution ones, some differences were simply attributed to the beam smearing of the HI caused by its lower resolution. The THINGS (The HI Nearby Galaxy Survey) project observed many galaxies of the SINGS (Spitzer Infrared Nearby Galaxies Survey) project. The kinematics of THINGS will be compared to the kinematic data of the galaxies obtained in Ha light. The comparison will try to determine whether the sole beam smearing is responsible of the differences observed. The results shows that intrinsic dissimilarities between the kinematical tracers used are responsible of some of the observed disagreements. The understanding of theses differences is of a high importance as the dark matter distribution, inferred from the rotation of the galaxies, is a test to some cosmological models.
5

Analyse cinématique de l'hydrogène ionisé et étude du gaz ionisé diffus de trois galaxies du Groupe Sculpteur : NGC253, NGC300 et NGC247

Hlavacek-Larrondo, Julie January 2009 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
6

Spectro-imagerie optique à faible flux et comparaison de la cinématique Ha et HI d'un échantillon de galaxies proches

Daigle, Olivier 02 1900 (has links)
Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques. / A new EMCCD (Electron multiplying Charge Coupled Device) controller is presented. It allows the EMCCD to be used for photon counting by drastically taking down its dominating source of noise : the clock induced charges. A new EMCCD camera was built using this controller. It has been characterized in laboratory and tested at the observatoire du mont Mégantic. When compared to the previous generation of photon counting cameras based on intensifier tubes, this new camera renders the observation of the galaxies kinematics with an integral field spectrometer with a Fabry-Perot interferometer in Ha light much faster, and allows fainter galaxies to be observed. The integration time required to reach a given signal-to-noise ratio is about 4 times less than with the intensifier tubes. Many applications could benefit of such a camera: fast, faint flux photometry, high spectral and temporal resolution spectroscopy, earth-based diffraction limited imagery (lucky imaging), etc. Technically, the camera is dominated by the shot noise for flux higher than 0.002 photon/pixel/image. The 21 cm emission line of the neutral hydrogen (HI) is often used to map the galaxies kinematics. The extent of the distribution of the neutral hydrogen in galaxies, which goes well beyond the optical disk, is one of the reasons this line is used so often. However, the spatial resolution of such observations is limited when compared to their optical equivalents. When comparing the HI data to higher resolution ones, some differences were simply attributed to the beam smearing of the HI caused by its lower resolution. The THINGS (The HI Nearby Galaxy Survey) project observed many galaxies of the SINGS (Spitzer Infrared Nearby Galaxies Survey) project. The kinematics of THINGS will be compared to the kinematic data of the galaxies obtained in Ha light. The comparison will try to determine whether the sole beam smearing is responsible of the differences observed. The results shows that intrinsic dissimilarities between the kinematical tracers used are responsible of some of the observed disagreements. The understanding of theses differences is of a high importance as the dark matter distribution, inferred from the rotation of the galaxies, is a test to some cosmological models.
7

Analyse cinématique de l'hydrogène ionisé et étude du gaz ionisé diffus de trois galaxies du Groupe Sculpteur : NGC253, NGC300 et NGC247

Hlavacek-Larrondo, Julie January 2009 (has links)
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal

Page generated in 0.0724 seconds