• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 159
  • 9
  • 1
  • Tagged with
  • 170
  • 40
  • 34
  • 32
  • 27
  • 26
  • 24
  • 21
  • 21
  • 20
  • 18
  • 18
  • 17
  • 16
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

QUALIFICAÇÃO DOS DISPOSITIVOS DE FACHADA QUANTO À DISPONIBILIDADE DE LUZ NATURAL: O CASO DO INSTITUTO FEDERAL DO ESPÍRITO SANTO CAMPUS COLATINA

FASSINA, S. P. 25 April 2017 (has links)
Made available in DSpace on 2018-08-02T00:17:17Z (GMT). No. of bitstreams: 1 tese_10943_Sirana Palassi Fassina.pdf: 14606630 bytes, checksum: 2ca8662749e7ab656294cfbcdf20251e (MD5) Previous issue date: 2017-04-25 / O uso da luz natural no ambiente interno traz benefícios aos usuários e influencia diretamente no seu comportamento e na sensação de conforto. Essas características, quando aplicadas a ambientes escolares se fazem ainda mais importantes, afetando diretamente o desenvolvimento e o aprendizado dos alunos. Por esse motivo, tem-se buscado otimizar o aproveitamento da luz natural no ambiente interno, aumentando seu desempenho e amenizando os possíveis inconvenientes. Dentre as possíveis estratégias, o uso de dispositivos externos à fachada faz-se importante por auxiliar na distribuição e aumento da luz natural nos espaços internos. Considerando as possibilidades, essa pesquisa buscou qualificar o desempenho de elementos de fachada na disponibilidade de iluminação natural, tendo como base uma sala de aula padrão do Instituto Federal do Espírito Santo (Ifes) campus Colatina. A metodologia de trabalho se baseou em simulações computacionais através do programa Troplux 7, onde foram definidos seis modelos de balcão refletor, ora associado a prateleiras de luz, ora associado aos brises, totalizando doze objetos de estudo. As simulações foram realizadas para todo os dias do ano, das 7h às 17h, para as principais orientações (Norte, Sul, Leste e Oeste) e em três condições de céu: céu encoberto (CIE 3), céu parcialmente nublado (CIE 7) e céu claro (CIE 12). Nas análises observou-se a disponibilidade de luz natural no ambiente interno, com os percentuais de horas do dia nos intervalos das UDI (Useful Daylight Illuminance) ao longo do ano, os percentuais de uniformidade da luz natural no ambiente interno e o comportamento da luz natural com relação à profundidade do ambiente. Os resultados mostraram que a existência de uma superfície refletora próxima aos peitoris das janelas influenciou nos resultados apresentados, independente de sua associação ora a prateleira de luz, ora a brises. Foi possível concluir também que o uso de prateleiras se mostrou superior, havendo maior admissão da luz dentro da faixa desejável (500≤E≤2000lx), com reduções das iluminâncias excessivas e maior uniformidade da iluminância no ambiente interno. Entretanto, os resultados apresentados pelos modelos associados aos brises mostrou-se igual ou pouco inferior ao obtido pelos modelos associados à prateleira de luz, o que demonstra adequabilidade dos dispositivos diante das variáveis analisadas.
12

Tecnologia de tratamentos de fissuras em fachadas de revestimento em pintura: um estudo de caso

Borduni, Charles Nunes January 2018 (has links)
Submitted by Gisely Teixeira (gisely.teixeira@uniceub.br) on 2018-06-18T18:42:41Z No. of bitstreams: 1 51600445.pdf: 13414330 bytes, checksum: 8b8b02e23dbde680f1b424bd49d8b043 (MD5) / Made available in DSpace on 2018-06-18T18:42:41Z (GMT). No. of bitstreams: 1 51600445.pdf: 13414330 bytes, checksum: 8b8b02e23dbde680f1b424bd49d8b043 (MD5) Previous issue date: 2018 / Manifestações de patologias em fachadas estão cada vez mais presentes nas edificações. O presente trabalho pretende relacionar manifestações de patologias em fachadas construídas em paredes de concreto com formas moldadas in loco. Nesse sentido, efetou-se um levantamento das manifestações de patologias, com especial foco para os revestimentos de pintura. Ademais, analisaram-se as obras em paredes de concreto no Riacho Fundo II/ DF, que além de identificar as anomalias existentes, procurou definir uma metodologia de reabilitação/ restauro mantendo a funcionalidade e o aspecto. Verificou-se que as manifestações patológicas analisadas nas fachadas dos edifícios nasceram de anomalias construtivas. Identificou-se também que a fissuração foi a principal anomalia encontrada. Este trabalho contempla ainda, numa fase posterior, um conjunto de recomendações, que indicam soluções para a reabilitação de fachadas dos edifícios, de forma a garantir que as mesmas assegurem resultados satisfatórios a longo prazo.
13

Durabilidade na construção : estimativa da vida útil de fachadas ventiladas

Ribeiro, Manuel Maria Loureiro de Bragança Sousa January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Construções Civis). Faculdade de Engenharia. Universidade do Porto. 2010
14

Potencial da aplicação de sistemas pré-fabricados na reabilitação térmica de fachadas

Sousa, Joana Raquel Bastos January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2010
15

Manifestações patológicas em fachadas com revestimentos argamassados

Silva, Armando Felipe da January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Arquitetura e Urbanismo / Made available in DSpace on 2012-10-23T03:35:00Z (GMT). No. of bitstreams: 1 240187.pdf: 3330012 bytes, checksum: 09183abfc2e51f9d78db26870510db55 (MD5) / Este trabalho analisa as manifestações patológicas que interferem nos revestimentos argamassados das fachadas de três edifícios residenciais com múltiplos pavimentos, situados em Florianópolis. Observa-se que, devido aos edifícios serem executados com sistemas construtivos convencionais e apresentarem pouco controle de qualidade nos serviços e materiais empregados, as manifestações patológicas encontradas nas fachadas dessas construções, independentemente de sua idade, costumam ser as mesmas. A falta de informação aos usuários sobre a necessidade de manutenção preventiva e reparativa dos edifícios contribui para a deterioração das fachadas em muitos edifícios situados em Florianópolis. Assim sendo, busca-se demonstrar com esse trabalho que as manifestações patológicas encontradas nesses três casos não estão somente vinculadas à qualidade do reboco, mas, sobretudo, à falhas de projeto e de execução, bem como à falta de manutenção nos sistemas estruturais e em elementos construtivos, tais quais calhas, lajes de cobertura, pingadeiras, box de banheiros e paredes externas.
16

Análise de desempenho térmico e acústico de fachadas ventiladas de porcelanato à luz da norma de desempenho : estudo de caso em Brasília-DF / Analysis of thermal and acoustic performance of porcelain ventilated facades in accordance with the performance standard : case study in Brasilia-DF

Santos Filho, Vamberto Machado dos 19 June 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2015-12-04T16:54:24Z No. of bitstreams: 1 2015_VambertoMachadodosSantosFilho .pdf: 4240732 bytes, checksum: 41c80f946e3069bc64b8f9693b72a8b4 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-19T19:22:03Z (GMT) No. of bitstreams: 1 2015_VambertoMachadodosSantosFilho .pdf: 4240732 bytes, checksum: 41c80f946e3069bc64b8f9693b72a8b4 (MD5) / Made available in DSpace on 2016-05-19T19:22:03Z (GMT). No. of bitstreams: 1 2015_VambertoMachadodosSantosFilho .pdf: 4240732 bytes, checksum: 41c80f946e3069bc64b8f9693b72a8b4 (MD5) / A entrada de novos sistemas construtivos no mercado brasileiro tem sido acompanhada de diversos questionamentos sobre o seu desempenho. Entre estes novos sistemas estão as Fachadas Ventiladas, que surgem com o apelo de um sistema com o potencial de melhorar os aspectos de habitabilidade da edificação. Esse sistema é caracterizado por uma camada de ventilação entre os painéis externos modulares e o substrato, prevendo um espaço vazio que permite, por efeito chaminé, uma ventilação continua. Neste trabalho foi realizado um estudo de desempenho de fachadas ventiladas com porcelanato (FVPo), comparativamente às fachadas de porcelanato aderido (FPoA). Para isto, foi utilizado um projeto de uma edificação habitacional modelo (EHM) para reproduzir as edificações típicas do Plano Piloto de Brasília-DF. Suas características, materiais e elementos de contorno permaneceram constantes, sendo a variável apenas o tipo da fachada. Para o auxílio dos cálculos do desempenho foram utilizados dois diferentes softwares, o Design Builder, para o desempenho térmico, e o Insul, para o desempenho acústico. Os critérios de análise foram estabelecidos pela norma de desempenho. Em cada critério da norma, os dois sistemas foram comparados e analisados com base nos resultados obtidos da simulação. As fachadas ventiladas de porcelanatos obtiveram melhores resultados de desempenho térmico, em todas as metodologias utilizadas, quando comparados à fachada de porcelanato aderido. Essa melhoria de desempenho pode ser explicada pelo fato de sua camada de ar ventilada renovar o ar aquecido diminuindo a transmissão de calor para o interior da edificação no período de verão, e evitar a transmissão de calor para o exterior da edificação nos períodos de inverno. Nas simulações de acústica os dois sistemas apresentaram o mesmo índice de isolamento sonoro, com um nível mínimo de desempenho, segundo critério da norma. Foi possível verificar a importância da esquadria no isolamento do sistema de fachada, pois ao aumentar a área da esquadria, o índice de isolamento diminui. / The insertion of new construction systems in the Brazilian market has been accompanied by many questions about its performance. Among these new systems are the Ventilated Facades, which come with the appeal of a system with the potential to improve aspects of habitability of the building. In this article, were compared two types of facades, a conventional, adhered facade of porcelain (FPoA), and an innovative one, the ventilated facade of porcelain (FVPo). To achieve the objectives, it was constructed a residential building model (EHM) which has the objective to reproduce the typical buildings of the Plano Piloto in Brasilia-DF. It’s features, materials and boundary element remained constant, changing only the type of the facade. The thermal and acoustic performance of these two systems was verified with the performance standard, using software to aid in the calculations, the Design Builder for thermal and the Insul for acoustics. In each criterion of the standard, the two systems were compared and analyzed based on the results of the simulation. The ventilated facades of porcelain performed better thermal performance in all methodologies used, compared to the facade of joined porcelain. This performance improvement can be explained by the fact that its air layer ventilated renew the heated air reducing heat transfer into the building during the summer and prevents heat transfer to the outside of the building in the winter periods. In acoustic simulations the two systems had the same sound insulation index, with a minimum performance standard. It was possible to verify the importance of squarely in insulation façade system, because by increasing the area of the miter, the isolation index decreases.
17

Manifestações patológicas em revestimentos cerâmicos de fachada em tres estudos de caso na cidade de Balneário Camboriú

Luz, Marcos de Almeida January 2004 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-graduação em Arquitetura e Urbanismo / Made available in DSpace on 2012-10-21T18:14:55Z (GMT). No. of bitstreams: 1 211565.pdf: 6231548 bytes, checksum: ef15e83d4da8204c8ac270d1d0952171 (MD5) / Ainda é grande o número de ocorrências de manifestações patológicas nos sistemas de revestimento cerâmico de fachadas de edifícios. As causas e origens são diversas e é de extrema dificuldade apontar somente uma origem ou causa para estas ocorrências. Na maioria dos casos, uma combinação de causas e origens pode ser a responsável pelo surgimento da manifestação patológica.
18

Avaliação do comportamento higrotérmico de revestimentos exteriores de fachadas devido à acção da chuva incidente

Freitas, Ana Sara Stingl Leal Araújo de Freitas January 2011 (has links)
Tese de mestrado integrado. Engenharia Civil - Especialização em Construções. Universidade do Porto. Faculdade de Engenharia. 2011
19

Reabilitação térmica de fachadas : Estudo de caso através de simulação numérica

Pinto, André Manuel de Jesus January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2010
20

Monomassas : caracterização comparativa dos produtos vigorantes no mercado

Sousa, Ana Catarina Dias de January 2009 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Construções). Faculdade de Engenharia. Universidade do Porto. 2009

Page generated in 0.0375 seconds