• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do desempenho de ciclistas em exercício isocinético com produção de fadiga : instrumentação, biomecânica e eletromiografia / Evaluation of cyclists's performance in isokinectic exercises with fatigue production : instrumentation, biomechanics and eletromyography

Carvalho, Thiago Raposo Milhomem de 15 December 2012 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, Programa de Pós-Graduação em Engenharia de Sistemas Eletrônicos e Automação, 2012. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2012-06-22T13:15:51Z No. of bitstreams: 1 2012_ThiagoRaposoMilhomemdeCarvalho.pdf: 3767204 bytes, checksum: fe993c0ecaa290f54d08e6f7aab31789 (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2012-06-25T10:42:46Z (GMT) No. of bitstreams: 1 2012_ThiagoRaposoMilhomemdeCarvalho.pdf: 3767204 bytes, checksum: fe993c0ecaa290f54d08e6f7aab31789 (MD5) / Made available in DSpace on 2012-06-25T10:42:46Z (GMT). No. of bitstreams: 1 2012_ThiagoRaposoMilhomemdeCarvalho.pdf: 3767204 bytes, checksum: fe993c0ecaa290f54d08e6f7aab31789 (MD5) / Neste trabalho desenvolveu-se instrumentação dedicada para digitalização e tratamento de sinais biomecânicos e biológicos durante a atividade do ciclismo. Estudaram-se o comportamento mioelétrico e biomecânico durante atividades de contrações cíclicas em exercícios isocinéticos com produção de fadiga. Foram propostos protocolos experimentais e metodologias objetivas para análise do desempenho destes ciclistas, baseando-se nos sinais eletromiográficos e biomecânicos coletados dos mesmos. Na avaliação de desempenho do ciclista, com respeito à técnica particular de pedalar, foi proposta uma metodologia que infere o esforço realizado em prol da geração de torque efetivo em relação ao esforço total despendido durante o exercício. Realizou-se, então, uma análise do comportamento mioelétrico do vasto lateral da perna esquerda de cada ciclista, a partir do processamento e da análise de seu sinal eletromiográfico coletado. Nesta análise foram computados parâmetros descritores da fadiga a partir de segmentos específicos dos sinais de eletromiografia. Seis ciclistas voluntários participaram das coletas, utilizando o mesmo cicloergômetro, as mesmas sapatilhas e eletrodos para a coleta do sinal eletromiográfico. Não foi observada, a princípio, nenhuma relação direta entre a dinâmica da fadiga e o comportamento do desempenho biomecânico ao longo da fase isocinética do exercício. Constituem-se contribuições principais deste trabalho: a definição de um critério objetivo para avaliação de desempenho com instrumentação dedicada; a implementação de um conjunto de técnicas associadas de processamento e condicionamento do sinal eletromiográfico para o cálculo dos descritores e uma análise conjunta dos sinais biomecânicos e eletromiográficos para a verificação da existência de relações diretas entre fadiga e desempenho biomecânico, podendo esta ideia ser estendida a outras modalidades esportivas. _______________________________________________________________________________ ABSTRACT / In this work, dedicated instrumentation for digitizing and biologic and biomechanical signal processing during cycling activities was developed. The myoelectric and biomechanical behaviors during cyclic contractions activities in isokinetic exercises with fatigue production were studied. Experimental protocols and objective methodologies for these cyclists’ performance analysis were proposed, based on the electromyographic and biomechanical signals collected from them. For the cyclist’s performance evaluation, regarding the particular pedaling technique, a methodology that infers the effort made in order to generate effective torque in relation to the total effort made during the exercise was proposed. An analysis of the myoelectric behavior of the left leg’s vastus lateralis of each cyclist was done, from the processing and analysis of their collected electromyographic signal. In such analysis, fatigue descriptor parameters were computed, based on specific segments of the electromyographic signals. Six volunteer cyclists participated in the data acquisition, using the same cycle ergometer, the same shoes and electrodes for the electromyographic signal collection. At first, no direct relationship between the fatigue dynamics and the biomechanical performance behavior during the exercise’s isokinetic phase was observed. This work’s main contributions are: the definition of an objective criterion for performance evaluation with dedicated instrumentation; the implementation of a set of associated electromyographic signal processing and conditioning techniques in order to compute the descriptors, and a joint analysis of the biomechanical and electromyographic signals to verify the existence of direct relationships between fatigue and biomechanical performance, with the possibility to extend this idea to other sport modalities.
2

Fadiga e comportamento tensão-deformação cíclico da liga de alumínio 7050-T7451

Fabara Hernández, Karen Viviana 29 April 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2016. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2016-05-17T13:36:13Z No. of bitstreams: 1 2016_KarenVivianaFabaraHernandez.pdf: 2185435 bytes, checksum: 0726fcb5f1846fde5cefba17fee5a10d (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-24T20:09:51Z (GMT) No. of bitstreams: 1 2016_KarenVivianaFabaraHernandez.pdf: 2185435 bytes, checksum: 0726fcb5f1846fde5cefba17fee5a10d (MD5) / Made available in DSpace on 2016-05-24T20:09:51Z (GMT). No. of bitstreams: 1 2016_KarenVivianaFabaraHernandez.pdf: 2185435 bytes, checksum: 0726fcb5f1846fde5cefba17fee5a10d (MD5) / O presente trabalho investiga o comportamento tensão-deformação cíclico e em fadiga da liga de alumínio 7050-T7451. Corpos de prova de seção circular cheia foram submetidos a deformação uniaxial controlada com razão de deformação igual a -1 e 0,01. Nos ensaios com -1, observou-se um pequeno amolecimento cíclico do material para amplitudes de deformação superiores a 0,85%. Para amplitudes de deformação inferiores a 0,85% o material não exibiu encruamento cíclico. A análise dos laços de histerese estabilizados indica que o material investigado exibe comportamento não-Masing para amplitudes de deformação inferiores a 0,6%. Nos ensaios com 0,01 observou-se um pequeno endurecimento cíclico do material para amplitudes de deformação acima de 0,5%. Para amplitudes de deformação inferiores a 0,5% o material não exibiu encruamento cíclico. Observou-se ainda que a tensão média de tração observada no primeiro ciclo de carregamento sofre um relaxamento, sendo este mais pronunciado nos primeiros ciclos de carregamento. Foram determinadas as propriedades cíclicas do material presente no interior e próximo à superfície da placa laminada utilizada para fabricação dos corpos de prova. Não foi observada uma variação significativa das propriedades cíclicas ao longo da espessura do bloco. A correlação entre as vidas observadas e as estimadas com a relação de Smith, Watson e Topper foi bastante satisfatória (todos os dados dentro de uma banda de fator 2). _______________________________________________________________________________________________ ABSTRACT / The cyclic stress-strain and fatigue behaviors of aluminum alloy 7050-T7451 are investigated in this work. Solid cylindrical specimens were subjected to strain-controlled uniaxial loading with strain ratio equal to -1 and 0.01. For , small cyclic softening of the material was observed for strain amplitudes greater than 0.85%. For strain amplitudes less than 0.85%, no cyclic hardening/softening was observed. The stabilized hysteresis loops of the material exhibit non-Masing behavior for strain amplitudes less than 0.6%. For 0.01, small cyclic hardening was observed in the material for strain amplitudes greater than 0.5%. For strain amplitudes less than 0.5%, no cyclic hardening/softening was observed. No significant variation of the cyclic properties along the thickness of the alloy 7050 plate was observed in the range of fatigue lives investigated (10105 cycles to failure). The mithWatsonTopper (SWT) parameter can satisfactorily correlate all the fatigue experiments on 7050-T7451 conducted in this study.

Page generated in 0.0644 seconds