Spelling suggestions: "subject:"falha dda prótese dentária"" "subject:"falha daa prótese dentária""
1 |
Comportamento biomecânico de estruturas multicamadas em restaurações protéticas / Biomechanical behavior of multilayer structures in dental prostheticCosta, Anna Karina Figueiredo [UNESP] 28 January 2016 (has links)
Submitted by ANNA KARINA FIGUEIREDO COSTA null (karina_fcosta@yahoo.com.br) on 2016-04-21T11:28:44Z
No. of bitstreams: 1
Anna Karina final 20 abril 2016.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-02T16:35:35Z (GMT) No. of bitstreams: 1
costa_akf_dr_sjc.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5) / Made available in DSpace on 2016-05-02T16:35:35Z (GMT). No. of bitstreams: 1
costa_akf_dr_sjc.pdf: 2862170 bytes, checksum: d49986540a33df5c364771ff7f6659c6 (MD5)
Previous issue date: 2016-01-28 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo desse trabalho foi identificar por meio da utilização de geometrias complexas (pela análise de elemento finito) e simplificadas, se novas tecnologias (sistema CAD/CAM) resultam em um comportamento biomecânico mais favorável na cerâmica de cobertura quando comparado à técnica de aplicação convencional (estratificação). Foram modelados três diferentes estruturas de prótese parcial fixa de três elementos com diferentes técnicas de fabricação: convencional, Rapid Layer (feldspática, cimento resinoso e zircônia) e CAD-on (dissilicato, material vítrio de baixa fusão e zircônia) a fim de analisar a distribuição tensão de tração gerada durante um ensaio mecânico pelo método por elementos finitos. Discos (cerâmica de cobertura e zircônia) foram unidos seguindo as três diferentes técnicas (convencional, Rapid Layer e CAD-on). Foram também confeccionadas próteses parciais fixas de 3 elementos pela técnica de multicamada seguindo as mesmas configurações dos modelos utilizados na análise por elementos finitos. Essas coroas foram cicladas durante 2x106 ciclos para analisar falhas na cerâmica de cobertura, como trincas, lascamento, delaminação e falha catastrófica. Os resultados mostraram que as coroas confeccionadas com cerâmica de dissilicato de lítio e material vítreo na interface infraestrutura/cerâmica de cobertura apresentaram menor concentração de tensão de tração quando comparadas aos modelos confeccionados pela técnica convencional, que demonstraram maior concentração de tensão de tração entre as camadas (cerâmica de cobertura, interface e infraestrutura). Para os discos, o acréscimo de material na interface cerâmica de cobertura e infraestrutura mostrou maior resistência à fratura biaxial e menor propagação da trinca entre as camadas de cerâmica. As coroas cicladas não apresentaram falhas como: trincas, lascamento, delaminação e catastrófica nos primeiros 500.000 ciclos. Porém, as próteses confeccionadas com cerâmica feldspática apresentaram trincas a partir de 1x106 ciclos, diferentemente das coroas confeccionadas na técnica Rapid Layer e CAD-on. As coroas confeccionadas pela técnica RL e CAD-on podem ser consideradas um sistema favorável por prevenir a propagação de trincas radiais em direção à superfície da restauração e melhorar a tenacidade à fratura do material. / The aim was to identify whether the CAD/CAM approach resulted in more favourable stressing patterns in the veneer-ceramic when compared with a conventionally sintered Y-TZP core/veneer-ceramic. Three different designs crowns of prosthesis with three elements and different manufacturing techniques were modeled: conventional technique, Rapid Layer (feldspathic ceramic, resin cement and zirconia) and CAD-on (disilicate, fusion glass ceramic and zirconia) techniques to analyze the distribution stress tensile generated during a mechanical test by the finite element method. Moreover, were made feldspathic ceramic discs, lithium disilicate discs and Y-TZP zirconia discs to analyze the influence of biaxial flexure stress of these three different techniques. These discs (veneer ceramic and zirconia ceramic) were joined following the three different techniques (conventional, Rapid Layer and CAD-on). They were also made FPDs 3 elements: following the same design of models used in finite element analysis. These crowns were cycled during 2x106 cycles to analyze failure at veneer ceramic, such as cracks, chipping, delamination and catastrophic failure. The results showed that the crowns made from ceramic lithium disilicate and low fusion glass ceramic at the interface veneer ceramic/infraestructure showed low concentration of tensile stress when compared to models made by the conventional technique, which showed a greater concentration of tensile stress between layers (veneer ceramic, interface and infrastructure). For the discs samples, the multilayer materials showed lower crack propagation between the ceramic layers. The cycled crowns showed no failure as cracks, chipping, delamination and catastrophic failure for the first 500,000 cycles. However, the prostheses made with feldspathic ceramic showed cracks from 1.106 cycles. The incorporation of functionally and aesthetically graded layers would be realisable, considerable research would be required before the feasibility of the conceptual approach could be accurately assessed. / FAPESP: 2012/11095-0
|
2 |
Avaliação da microestrutura óssea de sítios implantares e fatores relacionados às alterações no nível ósseo marginal e estabilidade de implantes dentários: estudo clínico prospectivo / Assessment of microstructure of jawbone sites and factors related to the changes on marginal bone level and dental implant stability: prospective clinical studyDias, Danilo Rocha 15 July 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T17:49:23Z
No. of bitstreams: 1
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-12T17:49:32Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-12T19:43:01Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:25:37Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5) / Made available in DSpace on 2014-12-16T09:25:37Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Tese-Danilo Rocha Dias-2013.pdf: 12690993 bytes, checksum: 8af178ce9d242439a10d9aafdd18a329 (MD5)
Previous issue date: 2013-07-15 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Bone characteristics influence surgical/prosthetic planning of implant treatment, but it is not clear their influence on longitudinal outcomes. This study aimed to investigate the association between jawbone microstructure and changes on marginal bone level (MBL) and implant stability (IS) after loading, in a 1-year follow-up. Forty-one volunteers received 97 dental implants, installed in bone sites classified from 1 to 4, according to Leckholm & Zarb (1985). Cortical bone thickness was measured on computed tomography images. Histomorphometric and microtomographic analyses were performed in bone specimens obtained by using a trephine bur, at first drilling. Peak insertion torque (PIT) and implant stability quotient (ISQ) measured by resonance frequency analysis (RFA) were registered at implant insertion. Periapical radiographs were standardized to measure the MBL, and were taken at three moments, when the ISQ was also measured: at uncovering stage, at loading and at 1-year follow-up. Agreement analysis between histomorphometry and microcomputed tomography (microCT) showed that these methods are complementary, but not interchangeably. Association tests revealed that ISQ changes were not affected by MBL changes. Bone type 4 (according L&Z) presented higher changes on ISQ, especially during osseointegration. Microstructure parameters (histomorphometric and microCT parameters) and cortical thickness did not influence ISQ changes and MBL changes. These results suggest that bone characteristics influence primary implant stability, but do not predict implant success after osseointegration. / Características do tecido ósseo influenciam o planejamento cirúrgico/protético dos implantes dentários, mas não está clara sua relação com o resultado longitudinal do tratamento com implantes. O objetivo deste estudo foi investigar a associação entre microestrutura óssea de sítios implantares da maxila e mandíbula, as alterações de nível ósseo marginal (MBL) e a estabilidade dos implantes (IS) até o período de 1 ano após a aplicação de carga oclusal. Quarenta e um pacientes receberam 97 implantes dentários, instalados em sítios ósseos classificados como tipos 1 a 4, de acordo com a classificação de Leckholm & Zarb (1985). A espessura de osso cortical foi mensurada em imagens de tomografia computadorizada. Análises microtomográficas e histomorfométricas foram realizadas em espécimes ósseos obtidos com trefina na primeira perfuração para instalação dos implantes. Torque de inserção final (PIT) e quociente de estabilidade do implante (ISQ) medido por análise de freqüência de ressonância (RFA) foram registrados durante a instalação dos implantes. Radiografias periapicais padronizadas para mensuração do MBL foram obtidas em tres momentos, quando novos registros do ISQ foram também realizados: durante a cirurgia de reabertura, na instalação das próteses e 1 ano após aplicação da carga oclusal. A análise de concordância entre os métodos de microtomografia computadorizada (microCT) e histomorfometria, mostrou que estes métodos são complementares, mas não intercambiáveis. Testes de associação mostraram que as alterações na IS não foram afetadas pelas alterações no MBL. Ossos classificados como tipo 4 apresentaram as maiores alterações da IS, principalmente durante a osseointegração. Os parâmetros microestruturais (parâmetros microtomográficos e histomorfométricos) e a espessura de cortical não influenciaram as alterações de IS e do MBL. Estes resultados sugerem que as características do sítio ósseo influenciam a estabilidade primária, mas não são preditores do sucesso dos implantes após a osseointegração.
|
Page generated in 0.0981 seconds