• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da durabilidade dos diferentes modelos de sondas de troca de gastrostomia / Durability of five different percutaneous endoscopic gastrostomy (PEG) tubes

Villela, Emanuele Lima 22 March 2013 (has links)
Introdução: No acompanhamento diário de pacientes que realizam troca de sonda de gastrostomia endoscópica percutânea (GEP), observa-se a preco- cidade com que ocorrem essas trocas devido à curta durabilidade da sonda, especialmente decorrente da ruptura do balão interno da sonda. Objetivo: Este estudo prospectivo visou à avaliação da durabilidade de cinco diferen- tes marcas de sondas de troca de GEP. Método: Cem procedimentos con- secutivos de troca de sonda de GEP (realizados em 65 pacientes) foram dis- tribuídos, a cada grupo de 20 procedimentos, em cinco grupos determinados pelas marcas de sondas avaliadas (Kangaroo®, Wilson Cook®, Silmag®, Fre- ka® e Bard®). Conforme o protocolo proposto, após a troca, os pacientes fo- ram seguidos ao longo de seis meses, e, nesse período, foram realizadas três avaliações para verificação de eventuais intercorrências. Para avaliação da durabilidade das sondas, foi considerado o período de permanência dos pacientes no protocolo, determinada pelo término do período de estudo ou pela necessidade de troca da sonda por ruptura do balão ou desgaste do tubo ou da tampa. As curvas de durabilidade das sondas foram determina- das pelo Método de Kaplan Meier e pelo Modelo de Regressão de Cox. Resultados: Houve variações importantes na durabilidade das sondas quando considerados os três motivos de troca da sonda associados. Essa diferença não foi observada quando se considerou apenas a ruptura do balão, cujas ocorrências se mostraram associadas com pacientes em uso de GEP por distúrbios neurológicos sem diagnóstico. A durabilidade das sondas foi tanto menor, quanto maior o número de trocas anteriores. Conclusões: A marca da sonda de troca de GEP não influenciou a sua durabilidade quando deter- minada pela ruptura do balão, mas, quando determinada também por des- gaste em tubo e tampa, as sondas Wilson Cook® apresentaram durabilidade significativamente maior do que as sondas Silmag® e Bard®. O número de trocas anteriores se mostrou fator determinante de menor durabilidade das sondas / Introduction: During the follow-up of patients after replacement of percuta- neous endoscopic gastrostomy (PEG) tubes, the early need of new replace- ments seems to be consequence of the short durability of the tubes, espe- cially due to the rupture of their internal balloon. Objectives: In this prospec- tive study, the durability of five different PEG tubes was estimated. Methods: One hundred consecutive procedures (in 65 patients) for replacing PEG tubes were divided into five groups determined by the tubes model: Kanga- roo®, Wilson Cook®, Silmag®, Freka® and Bard®. According to the protocol developed for the study, patients were followed up along six months, and three evaluations for verifying eventual outcomes were carried out during this period. Estimation of the tubes durability considered the time patients re- mained in the protocol, which was determined by the termination of the follow up period or by the need for replacing the tubes due to the balloon rupture or to the loss of use of tube or cover. Curves of tubes durability were estab- lished by applying the Kaplan-Meier Method and the Cox Regression Model. Results: Important variations of the tubes durability were observed when the three causes for replacement were considered all together. Differences were not observed when considered only the balloon rupture, which was associated with patients using PEG in virtue of not specified neurologic disorders. Shorter tubes durability was associated with more previous replacements. Spontaneous opening of the cover and slipping of the external protection were significantly less frequent in the Freka® tubes, although such outcomes did not determined the tubes durability. Conclusion: The model of PEG re- placement tubes did not influence their durability regarding the balloon rup- ture alone. Considering such occurrence associated with problems in tubes or covers, the longest durability was observed in Wilson Cook®, followed by Freka, ® Kangaroo®, Silmag® and Bard® tubes. The number of previous re- placements showed to be determining factor for the tubes durability
2

Avaliação da durabilidade dos diferentes modelos de sondas de troca de gastrostomia / Durability of five different percutaneous endoscopic gastrostomy (PEG) tubes

Emanuele Lima Villela 22 March 2013 (has links)
Introdução: No acompanhamento diário de pacientes que realizam troca de sonda de gastrostomia endoscópica percutânea (GEP), observa-se a preco- cidade com que ocorrem essas trocas devido à curta durabilidade da sonda, especialmente decorrente da ruptura do balão interno da sonda. Objetivo: Este estudo prospectivo visou à avaliação da durabilidade de cinco diferen- tes marcas de sondas de troca de GEP. Método: Cem procedimentos con- secutivos de troca de sonda de GEP (realizados em 65 pacientes) foram dis- tribuídos, a cada grupo de 20 procedimentos, em cinco grupos determinados pelas marcas de sondas avaliadas (Kangaroo®, Wilson Cook®, Silmag®, Fre- ka® e Bard®). Conforme o protocolo proposto, após a troca, os pacientes fo- ram seguidos ao longo de seis meses, e, nesse período, foram realizadas três avaliações para verificação de eventuais intercorrências. Para avaliação da durabilidade das sondas, foi considerado o período de permanência dos pacientes no protocolo, determinada pelo término do período de estudo ou pela necessidade de troca da sonda por ruptura do balão ou desgaste do tubo ou da tampa. As curvas de durabilidade das sondas foram determina- das pelo Método de Kaplan Meier e pelo Modelo de Regressão de Cox. Resultados: Houve variações importantes na durabilidade das sondas quando considerados os três motivos de troca da sonda associados. Essa diferença não foi observada quando se considerou apenas a ruptura do balão, cujas ocorrências se mostraram associadas com pacientes em uso de GEP por distúrbios neurológicos sem diagnóstico. A durabilidade das sondas foi tanto menor, quanto maior o número de trocas anteriores. Conclusões: A marca da sonda de troca de GEP não influenciou a sua durabilidade quando deter- minada pela ruptura do balão, mas, quando determinada também por des- gaste em tubo e tampa, as sondas Wilson Cook® apresentaram durabilidade significativamente maior do que as sondas Silmag® e Bard®. O número de trocas anteriores se mostrou fator determinante de menor durabilidade das sondas / Introduction: During the follow-up of patients after replacement of percuta- neous endoscopic gastrostomy (PEG) tubes, the early need of new replace- ments seems to be consequence of the short durability of the tubes, espe- cially due to the rupture of their internal balloon. Objectives: In this prospec- tive study, the durability of five different PEG tubes was estimated. Methods: One hundred consecutive procedures (in 65 patients) for replacing PEG tubes were divided into five groups determined by the tubes model: Kanga- roo®, Wilson Cook®, Silmag®, Freka® and Bard®. According to the protocol developed for the study, patients were followed up along six months, and three evaluations for verifying eventual outcomes were carried out during this period. Estimation of the tubes durability considered the time patients re- mained in the protocol, which was determined by the termination of the follow up period or by the need for replacing the tubes due to the balloon rupture or to the loss of use of tube or cover. Curves of tubes durability were estab- lished by applying the Kaplan-Meier Method and the Cox Regression Model. Results: Important variations of the tubes durability were observed when the three causes for replacement were considered all together. Differences were not observed when considered only the balloon rupture, which was associated with patients using PEG in virtue of not specified neurologic disorders. Shorter tubes durability was associated with more previous replacements. Spontaneous opening of the cover and slipping of the external protection were significantly less frequent in the Freka® tubes, although such outcomes did not determined the tubes durability. Conclusion: The model of PEG re- placement tubes did not influence their durability regarding the balloon rup- ture alone. Considering such occurrence associated with problems in tubes or covers, the longest durability was observed in Wilson Cook®, followed by Freka, ® Kangaroo®, Silmag® and Bard® tubes. The number of previous re- placements showed to be determining factor for the tubes durability
3

Metalografia, análise de oxigênio e nitrogênio e teste de dureza vickers dos materiais de fixação interna usados no esqueleto craniofacial / Metallography, oxygenand nitrogen composition and vickers hardness test of internal fixation materials used in the craniofacial skeleton

Mendes, Marcelo Breno Meneses, 1984- 21 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T14:42:14Z (GMT). No. of bitstreams: 1 Mendes_MarceloBrenoMeneses_M.pdf: 5487742 bytes, checksum: e1f89d1bc60060a4c330175efda763d9 (MD5) Previous issue date: 2012 / Resumo: Este trabalho tem o objetivo de analisar, através de metalografia, análise da composição de gases oxigênio e nitrogênio e por meio de teste de dureza Vickers, 4 marcas de material de fixação interna utilizadas na cirurgia buco-maxilo-facial (grupo I = Leibinger; grupo II = Tóride; grupo III = Engimplan; grupo IV = Medartis). Inicialmente, foram confeccionados três corpos de prova com segmento de placa de três elos e três corpos de prova com parafusos, para cada grupo. Realizou-se preparação e análise metalográfica, de acordo com as normas da ASTM E3-95. Em seguida, as amostras foram submetidas ao teste de dureza Vickers, obedecendo às normas da ASTM E92. Após, foi realizado análise da composição de gases oxigênio e nitrogênio, com um segmento de elo de placa e um parafuso, para cada grupo. Os dados foram submetidos à análise de variância e teste de Tukey para comparação dos resultados. Todas as etapas dos processos foram registradas e fotografadas. De acordo com os resultados encontrados, os parafusos apresentaram maior dureza, em comparação com as placas. Entre estas, as placas do grupo IV apresentaram os grãos de maiores dimensão. A análise da composição dos gases revelou que todos os grupos atendem às normas ASTM / Abstract: This study aims to analyze 04 brands of internal fixation material, used in oral and maxillofacial surgery (Leibinger = group I; Tóride = group II; Engimplan = group III; Medartis = group IV) by metallography, analyzing the composition of gaseous oxygen (O) and nitrogen (N), and Vickers hardness testing. Initially,three specimens with three rings of the plate and three specimens with screws were made for each group. The preparation of the specimens was performed to metallographic analysis, attending the ASTM E3-95 standards. And then the samples were submitted to Vickers hardness test, according to the ASTM E92 standards. Thereafter, the composition analysis of the contents of O and N in all groups was performed with a ring of the plate and a screw for each group. Data were submitted to ANOVA and Tukey's test for result comparison. All steps of the process were recorded and photographed. According to the results, the screws had higher hardness, compared to the plates. Including, the plates of group IV showed the largest grain size. The analysis of the gas composition showed that all groups followed ASTM standards / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
4

Análise fractográfica e de resistência mecânica de duas marcas de placas de titânio em fraturas simuladas em corpo de hemimandíbulas de alumínio / Fractographic and mechanical analysis of two brands of titanium plates in simulated body fractures of aluminum hemimandibles

Moura, Andrezza Lauria de, 1982- 06 April 2013 (has links)
Orientadores: Marcelo Marotta Araújo, Roger William Fernandes Moreira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-23T00:56:38Z (GMT). No. of bitstreams: 1 Moura_AndrezzaLauriade_M.pdf: 4155630 bytes, checksum: 44572134d9e31084a7892cb0866a1d79 (MD5) Previous issue date: 2013 / Resumo: O propósito no estudo foi avaliar comparativamente, através de teste de carregamento linear e análise fractográfica, duas marcas de material de fixação interna estável com dois métodos de fixação em fraturas simuladas em corpo de hemimandíbulas de alumínio. O trabalho foi dividido em dois grupos: Grupo I com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação com duas placas de titânio de quatro furos do sistema 2,0mm, sendo uma placa na zona de compressão e outra zona de tensão, totalizando 20 placas de titânio; e grupo II, com duas estruturas de alumínio semelhantes à hemimandíbulas e fixação de uma placa de titânio de quatro furos do sistema 2,0mm na zona neutra de corpo de mandíbula, totalizando 10 placas de titânio. Testes de carregamento linear foram realizados por meio da máquina para ensaio universal mecânica Instron®, até a fratura do material. Após os testes, foram realizadas as análises fractográficas das superfícies de fratura dos materiais de fixação (grupos I e II) através de microscópio eletrônico de varredura FEI®, com o objetivo de analisar orientações, texturas e falhas dos materiais. Médias e desvio padrão das cargas e deslocamentos foram avaliados aplicando-se a Análise de Variância (ANOVA) two-way e teste de Tukey em nível de significância de 5%. Os resultados mostraram que o método de fixação com duas placas retas de quatro furos apresentou maior resistência à carga (p<0,01), quando comparado ao grupo de apenas uma placa de titânio na zona neutra mandibular. Ainda, a marca Traumec® apresentou maior resistência mecânica (p<0,01) quando utilizada no método com duas placas de fixação e a marca Tóride® (p<0,01) apresentou maior resistência as carga quando utilizada no método com apenas uma placa de fixação. A fractografia informou que todas as fraturas ocorreram por sobrecarga dúctil e micromecanismo alveolar / Abstract: The purpose of the study was to comparatively evaluate, through linear load test and fractographic analysis, two brands of stabel internal fixation in two methods of fixation in simulated body fractures in aluminium hemimandibules. The study was divided into two groups: Group I with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the compression zone and another one in tension zone, totaling 20 miniplates; and group II, with two aluminum structures similar to hemimandibles for fixation of one 2,0mm miniplate in the neutral zone of the mandible, totaling 10 miniplates. Mechanical tests were performed via mechanical universal testing machine Instron¿ until complete failure of the material. After the tests, fractography analysis of fractured surfaces were done in all materials (groups I and II) by a FEI¿ scanning electron microscopy, with the objective of analyzing orientation and textures of materials failures. Means and standard deviations of load and displacement were evaluated by applying the analysis of variance (ANOVA) two-way and the Tukey test at a significance level of 5%. The results showed that the method of fixation with two titanium plates with four holes showed higher resistance loads (p<0,01), when compared to only one titanium plate in the neutral zone of the mandible. Furthermore, the brand Traumec¿ showed higher mechanical strength (p<0,01) when used in the method with two fixing plates and the brand Toride¿ (p<0,01) showed a higher resistance to loads when used in the method with only one miniplate. The fractography reported that all fractures occurred in ductile overload and alveolar micromechanisms / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestra em Clínica Odontológica

Page generated in 0.0868 seconds