EVALUATION OF TRANSITIONS FOR TESTING AGRICULTURAL VENTILATION FANS WITH THE FAN ASSESSMENT NUMERATION SYSTEM (FANS)

Lopes, Igor Moreira 01 January 2012 (has links)
The Fan Assessment Numeration System (FANS) is an improved air velocity traverse method for measuring in situ fan performance. The FANS has been widely used, but variations of its test procedure are commonly employed to accommodate physical or operational barriers encountered in the field. This laboratory study evaluated the use of transitions to connect a 1.37m FANS unit to two smaller fans (1.22m and 0.91m diameter) and one 1.37m diameter fan. Tests were conducted with the FANS unit positioned on both intake and discharge sides of the fans. Three different transition angles (30o, 45o and 60o) and the use of no transition were evaluated. Discharge tests were also performed with no enclosed connection between FANS and fan housings. A different experiment was conducted for each fan size. Data was analyzed by comparing test results to the control with Dunnett’s procedure. Results showed significant differences as much as 5.3% ± 1.20% for intake treatments, 17.2% ± 3.04% for sealed discharge treatments and 37.1% ± 12.24% for discharge treatments with no enclosed connection. All transition angles produced similar fan test results. Differences between test results from the discharge and control treatments increased as differences between FANS and fan dimensions increased.
2

INFLUENCE OF FAN OPERATION ON FAN ASSESSMENT NUMERATION SYSTEM (FANS) TEST RESULTS

Morello, Gabriela Munhoz 01 January 2011 (has links)
The use of velocity traverses to measure in-situ air flow rate of ventilation fans can be subject to significant errors. The Fan Assessment Numeration System (FANS) was developed by the USD-ARS Southern Poultry Research Laboratory and refined at the University of Kentucky to measure air flow of fans in-situ. The procedures for using the FANS unit to test fans in-situ are not completely standardized. This study evaluated the effect of operating fan positions relative to the FANS unit for ten 1.22 m diameter fans in two types of poultry barns, with fans placed immediately next to each other and 1.6 m apart. Fans were tested with the FANS unit placed near both the intake and discharge sides of the tested fans. Data were analyzed as two Generalized Randomized Complete Block designs (GRCB), with a 2 (FANS inside or outside) x 6 (operating fan combinations) factorial arrangement of treatments. Results showed significant differences as much as 12.6 ± 4.4% between air flow values obtained under conditions of different operating fan combinations. Placing the FANS unit outside provided valid fan test results. A standardized procedure for using the FANS unit to test fans in-situ was elaborated and presented in this work.