INFLUENCE OF FAN OPERATION ON FAN ASSESSMENT NUMERATION SYSTEM (FANS) TEST RESULTSMorello, Gabriela Munhoz 01 January 2011 (has links)
The use of velocity traverses to measure in-situ air flow rate of ventilation fans can be subject to significant errors. The Fan Assessment Numeration System (FANS) was developed by the USD-ARS Southern Poultry Research Laboratory and refined at the University of Kentucky to measure air flow of fans in-situ. The procedures for using the FANS unit to test fans in-situ are not completely standardized. This study evaluated the effect of operating fan positions relative to the FANS unit for ten 1.22 m diameter fans in two types of poultry barns, with fans placed immediately next to each other and 1.6 m apart. Fans were tested with the FANS unit placed near both the intake and discharge sides of the tested fans. Data were analyzed as two Generalized Randomized Complete Block designs (GRCB), with a 2 (FANS inside or outside) x 6 (operating fan combinations) factorial arrangement of treatments. Results showed significant differences as much as 12.6 ± 4.4% between air flow values obtained under conditions of different operating fan combinations. Placing the FANS unit outside provided valid fan test results. A standardized procedure for using the FANS unit to test fans in-situ was elaborated and presented in this work.
|
2 |
EVALUATION OF TRANSITIONS FOR TESTING AGRICULTURAL VENTILATION FANS WITH THE FAN ASSESSMENT NUMERATION SYSTEM (FANS)Lopes, Igor Moreira 01 January 2012 (has links)
The Fan Assessment Numeration System (FANS) is an improved air velocity traverse method for measuring in situ fan performance. The FANS has been widely used, but variations of its test procedure are commonly employed to accommodate physical or operational barriers encountered in the field. This laboratory study evaluated the use of transitions to connect a 1.37m FANS unit to two smaller fans (1.22m and 0.91m diameter) and one 1.37m diameter fan. Tests were conducted with the FANS unit positioned on both intake and discharge sides of the fans. Three different transition angles (30o, 45o and 60o) and the use of no transition were evaluated. Discharge tests were also performed with no enclosed connection between FANS and fan housings. A different experiment was conducted for each fan size. Data was analyzed by comparing test results to the control with Dunnett’s procedure. Results showed significant differences as much as 5.3% ± 1.20% for intake treatments, 17.2% ± 3.04% for sealed discharge treatments and 37.1% ± 12.24% for discharge treatments with no enclosed connection. All transition angles produced similar fan test results. Differences between test results from the discharge and control treatments increased as differences between FANS and fan dimensions increased.
|
3 |
Influence of geometric and environmental parameters on air-cooled steam condenser performanceJoubert, Retief 03 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2010. / ENGLISH ABSTRACT: Air-cooled steam condensers (ACSCs) are used in the power generation industry to directly
condense turbine exhaust steam in areas where cooling water is expensive or unavailable.
Large axial flow fans force ambient air through A-frame heat exchanger bundles made up of a
number of rows of finned tubes through which the steam is ducted and consequently
condensed during the heat transfer process to the air. The heat rejection rate or performance
of an ACSC is proportional to the air mass flow rate, determined by fan volumetric
performance, and the temperature difference between the finned tubes and the air.
The air flow through a 30 fan ACSC (termed the generic ACSC) operating under windy
conditions is solved using the commercial computational fluid dynamics (CFD) code FLUENT
and the required data is extracted from the solution to calculate performance trends. It is
found that fan performance is reduced due to a combination of factors. The first is additional
upstream flow losses caused by separated flow occurring primarily at the leading edge of the
ACSC and secondarily at the fan bellmouth inlets. The second factor leading to reduced fan
performance is the presence of distorted flow conditions at the fan inlets. Hot plume air
recirculation is responsible for decreased ACSC thermal performance due to increased fan inlet
air temperatures. It is found that reduced fan performance is the greater contributor to
reduced ACSC performance.
The performance effects of varying two geometrical parameters of the generic ACSC, namely
the fan platform height and the windwall height, are investigated under windy conditions. It is
found that each parameter is linked to a specific mechanism of performance reduction with
the fan platform height affecting fan performance and the windwall height affecting
recirculation. The respective platform and windwall heights specified for the generic ACSC are
found to provide acceptable performance results.
To mitigate wind induced performance reductions a number of modification and additions to
the ACSC are investigated. These primarily aim at improving fan performance and included the
addition of walkways or skirts, the addition of wind screens beneath the fan platform,
removing the bellmouth fan inlets, using different types of fans and increasing fan power. The
addition of a periphery walkway and windscreens is considered to be the most practical
methods of improving ACSC performance under windy conditions. The generic ACSC is
modified to include both modifications and under high wind conditions the performance is
found to increase measurably. The modifications also resulted in the ACSC performance being
less sensitive to wind direction effects. / AFRIKAANSE OPSOMMING: Lugverkoelde kondensators word in die kragopwekkings industrie gebruik om turbine
uitlaatstoom te kondenseer, veral in gebiede waar verkoelingwater duur of onbeskikbaar is.
Aksiaalvloei-waaiers forseer omgewingslug deur A-raam warmteuitruiler bondels wat bestaan
uit verskeie rye vinbuise. Die uitlaatstoom vloei in die vinbuise en kondenseer as gevolg van
die warmteoordrag na die lug. Die warmteoordragkapasiteit van die lugverkoelde stoom
kondensator is eweredig aan die massavloei-tempo van die lug, wat bepaal word deur die
waaierwerkverigting, en die temperatuur verskil tussen die vinbuise en die lug.
Die lugvloei deur 'n 30 waaier lugverkoelde stoom kondensator (genoem die generiese
lugverkoelde stoom kondensator) onderworpe aan winderige toestande word opgelos deur die
gebruik van die kommersiële vloeidinamika-pakket, FLUENT. Die nodige data is onttrek uit die
oplossing en werkverrigting neigings is bereken. Dit is gevind dat waaierwerkverigting
verminder as gevolg van 'n kombinasie van faktore. Die eerste is bykomende vloeiverliese wat
veroorsaak word deur vloeiwegbreking wat plaasvind primêr by die voorste rand van die
lugverkoelde stoom kondensator asook by die klokvormige waaier-inlate. 'n Tweede faktor wat
lei tot vermindere waaierwerkverigting is die teenwoordigheid van lugvloeiversteurings by die
waaier-inlate. Hersirkulering van warm pluim lug is ook verantwoordelik vir verminderde
lugverkoelde stoom kondensator werkverrigting. Daar word bevind dat die vermindering in
waaierwerkverrigting die grootste bydraende faktor tot vermindere lugverkoelde stoom
kondensator werkverrigting is.
Die effek van verandering van twee geometriese lugverkoelde stoom kondensator parameters,
naamlik die waaierplatformhoogte en die windwandhoogte is ondersoek onder winderige
toestande. Daar word bevind dat elk van die parameters gekoppel is aan 'n spesifieke
meganisme van vermindere lugverkoelde stoom kondensator verrigting: Die
waaierplatformhoogte beïnvloed waaierverrigting terwyl die windwandhoogte hersirkulering
beinvloed. Daar word ook bevind dat die onderskeie waaierplatform- and windwandhoogtes
van die generiese lugverkoelde stoom kondensator, van so 'n aard is dat dit aanvaarbare
werkverrigting tot gevolg het.
Om verlaging in werksverrigting in winderige toestande te verminder is verskeie modifikasies
en byvoegings tot die lugverkoelde stoom kondensator ondersoek wat primêr gemik is op
verbetering in waaierwerkverigting. Die ondersoek dek die byvoeging van 'n loopvlak, die
byvoeging van windskerms onder die waaierplatform, verwydering van die klokvormige
waaier-inlate, die gebruik van verskillende waaiers en die verhoging van waaierdrywing. Daar
was besluit dat die byvoeging van 'n loopvlak rondom die rand van die lugverkoelde stoom
kondensator en die byvoeging van windskerms die mees praktiese manier was om die
lugverkoelde stoom kondensator verigting te verbeter. Die generiese lugverkoelde stoom
kondensator was aangepas om beide veranderings in te sluit en meetbare verbetering in
werkrigting was verkry. Die veranderings het ook meegebring dat die lugverkoelde stoom
kondensator minder sensitief is vir windrigting effekte.
|
4 |
Edge fan performance in air cooled condensers systemsConradie, P. J. F. 03 1900 (has links)
Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2010. / ENGLISH ABSTRACT: Large air‐cooled heat exchangers and condensers make use of fan arrays to provide cooling. The
performance of the fan arrays are however negatively affected by distorted inlet conditions. Given
the size of these fans, quantifying exactly what the detrimental effects are is practically impossible.
This serves as motivation for developing a scaled multi‐fan testing platform that is able to mimic the
behaviour of a full‐scale array but at a more measureable and manageable scale. This investigation
was conducted in two parts. A Reynolds number investigation was conducted to determine what
effect incorporating Reynolds number effects will have on the scaled fan performance.
Computational fluid dynamics (CFD) was used to determine where turbulent transition onset occurs
on the full‐scale fan blades and trip wires were then sized and positioned appropriately to recreate
the same transition effect. From this initial investigation it was found that the trip wires have an allround
negative impact on fan performance but when compensated for by increasing the blade angle,
the tripped fan static pressure rise performance is comparable with the non‐tripped fan
performance. This suggests that the Reynolds number effects may be ignored for this scaled fan
testing investigation.
Scaled equivalents of the fans in cooling arrays were tested in a three row multi‐fan array which,
using symmetry, represents a typical bay in a full‐scale installation. Various platform heights were
simulated and the corresponding decrease in system performance was compared to a model
formulated to predict how fan volumetric effectiveness decreases with platform height. The model
deviated from the test data at very low platforms heights. A replacement fan for the scaled
equivalent fan was tested while installed as the edge fan of a multi‐fan array, the fan worst affected
by any inlet disturbance, and was found to perform similarly to the scaled equivalent fan for most
platform heights but exceeded the scaled equivalent fan’s performance for the lowest platform
height and the most adverse conditions. This proves the effectiveness of the replacement fan as an
edge fan. / AFRIKAANSE OPSOMMING: Groot lugverkoelde warmteruilers maak gebruik van waaier matrikse om verkoeling te voorsien. Die
verrigting van die waaieropstelling word egter negatief beïnvloed deur versteurde inlaattoestande.
Gegewe die grootte van hierdie waaiers is daar geen praktiese metode om die nadelige invloed van
die versteurde inlaattoestande te kwantifiseer nie. Hierdie dien as motivering vir die ontwikkeling
van ‘n multi‐waaier toetsplatform wat daartoe in staat is om die gedrag van die volskaal opstelling na
te boots maar op ‘n baie meer meetbare en hanteerbare skaal. Hierdie ondersoek was uitgevoer in
twee dele. ‘n Reynoldsgetal ondersoek was uitgevoer om te bepaal watter impak dit sal hê op die
skaalwaaier verrigting indien die Reynolds getaleffekte ingesluit word in die toetswerk. Berekende
vloeidinamka (BVD) was gebruik om te bepaal waar turbulente oorgang voorkom op die volskaal
waaierlemme en pooitjiedrade was geselekteer en geposisioneer hiervolgens om dieselfde oorgang
te herskep. Vanuit hierdie aanvanklike ondersoek was dit gevind dat die pooitjiedrade ‘n algehele
afname in verrigting tot gevolg het, maar wanneer dit oorkom word deur die lemhoek op te stel, die
gedrag en verrigting van die gepooitjiede waaier soortgelyk is aan die van die nie‐gepooitjiede
waaier. Hierdie gedrag stel voor dat die Reynoldsgetalle maar geïgnoreer kan word vir hierdie
skaalwaaier toetswerk.
Gelykwaardige skaalwaaiers van die wat in bedryf is in volskaal opstellings was getoets in ‘n drie ry
multi‐waaier opstelling wat, deur simmetrie, verteenwordigend is van ‘n tipiese straat in ‘n volskaal
opstelling. Verskeie platformhoogtes was gesimuleer en die ooreenstemmende afname in stelsel
verrigting was vergelyk met ‘n model wat geformuleer is juis om te voorspel hoe die volumetriese
effektiwiteit afneem met platformhoogte. Die model wyk af van die toetsdata by baie lae platform
hoogtes. ‘n Vervangingswaaier vir die aanvanklike geskalleerde waaier was getoets as ‘n randwaaier,
die waaier wat die ergste benadeel word deur versteurde inlaattoetstande, in die multi‐waaier
opstelling. Die vervangingswaaier het soortgelyk aan die aanvanklike waaier verrig vir meeste
platformhoogtes, maar oortref die aanvanklike waaier se werksverrigting by die laagste
platformhoogte en mees ongunstige toestande. Hierdie bewys die vermoëns van die
vervangingswaaier as ‘n randwaaier.
|
5 |
Cooling Fan Optimization for Heavy Electrified Vehicles : A study on performance and noise / Kylfläktoptimering för Tunga Elektrifierade Fordon : En studie om prestanda och bullerKhiabani, Amir, Acebo Alanis, Daniel January 2020 (has links)
Vehicle electrification plays a significant role in the effort to reduce the environmental impact of the automotive industry. Scania is one of the leading manufacturers ofheavy vehicles which is currently moving towards a sustainable transport system by manufacturing a new generation of heavy vehicles powered by batteries. Oneof the major concerns with these vehicles is related to the noise generated by the electric axial fans used in the cooling system. This project was conducted with thepurpose of investigating the factors that positively affect both noise and performance in the electric fans. Based on two different blade design methods and several noisecontrol techniques, 11 fan models were developed. The fan models created with design method 1 are equipped with cambered-plate blades, while the models madewith design method 2 consist of airfoil-shaped blades. Moreover, the performance of these models was analyzed by using theoretical methods and Computational FluidDynamics (CFD). In addition, two empirical approaches were used to estimate the acoustic energy emitted by the fan models. Furthermore, the developed modelswere compared with two commercially available fans. It was found that both design methods provide similar performance in low pressure differences. On the other hand,the efficiency and acoustic energy are influenced by the choice of the noise control methods. / Fordonselektrifiering har en väsentlig roll i arbetet med att minska bilindustrins miljöpåverkan. Scania är en av de ledande tillverkarna av tunga fordon som för närvarandegår mot ett hållbart transportsystem, genom att tillverka en ny generation tunga fordon drivna med batterier. Ett stort bekymmer med dessa fordon är relaterattill det ljud som genereras av de elektriska axialfläktarna som används i kylsystemet. Detta projekt genomfördes i syfte till att undersöka de faktorer som positivtpåverkar både buller och prestanda hos de elektriska fläktarna. Baserat på två olika bladdesignmetoder och flera brusstyrningstekniker, utvecklades 11 fläktmodeller.Fläktmodellerna som är utformade med konstruktionsmetod 1 är utrustade med krökformade plattor, medan modellerna som skapades med designmetod 2 bestårav vingprofil blad. Dessutom analyserades prestandan för dessa modeller med användning av teoretiska metoder och strömningsmekaniska beräkningar. Ytterligaretvå empiriska tillvägagångssätt användes för att uppskatta den akustiska energin som släppts ut av fläktmodellerna. Utöver det jämfördes de utvecklade modellernamed två kommersiellt tillgängliga fläktar. Detta visade att båda konstruktionsmetoderna resulterar i liknande prestanda vid lågtrycksskillnader, däremot påverkasverkningsgraden och den akustiska energin av valet av brusstyrningsmetoder.
|