• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 7
  • 5
  • 1
  • Tagged with
  • 53
  • 53
  • 13
  • 12
  • 10
  • 10
  • 10
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

The effect of air velocity on thermal comfort with moderate activity

Hsieh, Kai - An. January 1985 (has links)
Call number: LD2668 .T4 1985 H74 / Master of Science
32

The design of a low-noise rotor-only axial flow fan series

Van der Spuy, Sybrand Johannes 12 1900 (has links)
ENGLISH ABSTRACT: A design routine was derived for designing a series of rotor-only axial flow fans. The routine was applied by designing two different series of axial flow fans. The first design was for a general application rotor-only axial flow fan. This fan series was designed, built and tested in co-operation with Howden Air Industries for both research and commercial purposes. The second design was for a low-noise fan series, which was designed, built and tested by the University of Stellenbosch for research purposes only. The design theory used the principle of blade cropping, meaning that one blade was designed to fit all the different fan sizes. The fan series was designed for diameters ranging from 3 15 mm to 1000 mm. The fan rotors were designed to conform to a velocity profile of minimum exit kinetic flux. The general application fan design was concentrated around the popular fan diameter sizes of 500 rnm, 560 mm and 630 mm and a rotor speed of 1440 rpm, using a commercially available fan series as reference. The low-noise fan design concentrated on one fan size only, namely 630 mm, while also making use of the principle of forward blade sweep. The remaining fan design principles stayed the same as for the general application fan design. The F-series airfoils were used as blade sections for both fan designs. Both fan series were tested for fan noise and performance in accordance with the BS 848 Standards part 1 (1980) and 2 (1985). A selection of fan diameter sizes was tested for the general application fan to verify its perfo!"mance over a range of fan sizes. This indicated a fan series with a wide range of efficient operation, including excellent noise characteristics. A 630 mm diameter fan was used to test the low-noise fan series. It showed both high efficiency and low noise characteristics. The reduction in fan noise achieved with the low-noise fan does not justi1)' the amount of work and costs involved in the designing process, compared to the general application fan. / AFRIKAANSE OPSOMMING: 'n Ontwerpsroetine vir die ontwerp van 'n reeks enkelrotor aksiaalwaaiers is ontwikkel. Die roetine is toegepas deur twee verskillende reekse aksiaalwaaiers te ontwerp. Die eerste ontwerp was vir 'n algemene toepassings enkelrotor aksiaalwaaier. Die waaierreeks is ontwerp, gebou en getoets in samewerking met Howden Air Industries vir beide navorsings - en kommersieIe doeleindes. Die tweede ontwerp was vir 'n lae geraas waaierreeks. Die reeks is ontwerp, gebou en getoets deur die Universiteit van Stellenbosch vir navorsingsdoeleindes. Die onwerpsteorie het gebruik gemaak van die beginsel van lemverkorting, waardeur een lem ontwerp is om op al die groottes waaierdeursnee te pas. Die waaierreekse is ontwerp vir waaierdeursnee tussen 315 mm en 1000 mm. Die rotors is ontwerp om 'n uitlaatsneIheidsprofiel te gee wat 'n minimum verlies in kinetiese energie toelaat. Die algemene toepassings waaierontwerp het gekonsentreer rondom die gewilde waaierdeursnee van 500 mm, 560 en 630 mm. Dit is ontwerp vir 'n rotorspoed van 1440 met 'n kommersieel beskikbare waaierreeks wat as verwysing gebruik is. Die lae geraas waaierreeks het op slegs een waaiergrootte gekonsentreer, naamlik 630 mm. Die lae geraas waaierreeks is ook ontwerp met vorentoe gekurfde lemme. Die res van die ontwerpsbeginsels was dieseIfde as vir die algemene toepassings waaierreeks. Die F-reeks vleuelprofiele is gebruik vir die lemseksies van beide waaierreekse. Beide waaiereekse is getoets vir waaiergeraas en -effektiwiteit deur gebruik te maak van die BS 848 Standaarde deel 1 (] 980) en 2 (] 985). 'n Verskeidenheid van waaierdeursnee van die algemene toepassings waaierreeks is getoets om die waaier se vertoning oor 'n gebied van waaiergroottes te bepaal. Die resuItaat was 'n waaierreeks met 'n wye gebied van effektiewe werking, asook uitstekende geraaseienskappe. 'n 630 mm Deursnee waaier is gebruik om die lae geraas waaier te toets. Die toetse het 'n waaier getoon wat beide hoe effektiwiteit en lae geraaseienskappe het. Die afname in waaiergeraas wat verkry is met die lae geraas waaier, in vergelyking met die algemene toepassings waaier, regverdig egter rue die werk en kostes verbonde aan die ontwerp van die waaierreeks nie.
33

An analysis of the external thermal field of an extra low profile dozer

14 September 2015 (has links)
M.Phil. / The aim of this research is to study the underhood airflow thermal behaviour of the extra low profile (XLP) dozer due to the excessive heat dissipated and observed during testing sessions executed at ground level, using computational fluid dynamics (CFD). The motivation of this project is to identify the reasons of poor cooling performance of this equipment, to develop and to demonstrate the capabilities of CFD in thermal research by validating the CFD result with experiments using a scaled model, prior to analyzing the full-scale dozer ...
34

Development of a scaled down laboratory test bed system for use in the optimisation of centrifugal fan driven air ventilation systems.

Harcharan, Ashvir. 12 October 2011 (has links)
This thesis describes work that has been carried out to develop a scaled down laboratory test bed for use in the optimisation of fan driven air ventilation systems found at the various Anglo Coal South African mines. The present system involved in the movement of air underground comprises a fixed speed centrifugal fan driven damper controlled system. National Power Contractors (NPC) together with the University of KwaZulu-Natal (UKZN) proposed a variable speed automated controlled system, but the costs of installing Variable Speed Drives (VSD) and their impact on the energy consumption of a system prior to being installed are important. In addition deliverables required by the industrial partner NPC was to develop a calibrated simulation model where any fan system could be simulated showing potential energy savings. A test bed was therefore constructed to evaluate the power usage of a VSD while driving a simulated fan. The test bed comprised of two Field Oriented Controlled induction machines. A ventilation system at Anglo Coal’s Vlaklaagte colliery was proposed to be simulated by the test bed to develop the Measurement and Verification (M&V) methodology required to represent a business case, but since data from this fan system was not available two other fan systems were studied. One fan system was built at the UKZN whilst the other industrial fan system was at Anglo Coal’s Greenside colliery. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2010.
35

Development and applications of fan airflow station and pump water flow station in heating, ventilating and air-conditioning (HVAC) systems

Liu, Guopeng. January 1900 (has links)
Thesis (Ph.D.)--University of Nebraska-Lincoln, 2006. / Title from title screen (site viewed May 22, 2007). PDF text:xviii, 204 p. : ill. (some col.) ; 2.37Mb UMI publication number: AAT 3237050. Includes bibliographical references. Also available in microfilm and microfiche formats.
36

The design of a single rotor axial flow fan for a cooling tower application

Bruneau, Phillippe Roger Paul, Von Backstrom, T. W. 12 1900 (has links)
Thesis (MEng (Mechanical Engineering))--University of Stellenbosch, 1994. / 213 leaves printed on single pages, preliminary pages i-xix and numbered pages 1-116. Includes bibliography, list of tables, list of figures and nomenclature. / Digitized at 600 dpi grayscale to pdf format (OCR), using a Bizhub 250 Konica Minolta Scanner. / ENGLISH ABSTRACT: A design methodology for low pressure rise, rotor only, ducted axial flow fans is formulated, implemented and validated using the operating point specifications of a 1/6th scale model fan as a reference. Two experimental fans are designed by means of the design procedure and tested in accordance with British Standards 848, Type A. The design procedure makes use of the simple radial equilibrium equations, embodied in a suite of computer programs. The experimental fans have the same hub-tip ratio and vortex distribution, but differ in the profile section used. The first design utilises the well known Clark-Y aerofoil profile whilst the second takes advantage of the high lift characteristics of the more modern NASA LS series. The characteristics of the two designs are measured over the entire operating envelope and compared to the reference fan from which the utility and accuracy of the design procedure is assessed. The performance of the experimental fans compares well with both the reference fan as well as the design intent. / AFRIKAANSE OPSOMMING: 'n Ontwerpmetode vir lae drukstyging, enkel rotor aksiaal waaiers is geformuleer, toegepas en bevestig deur gebruik te maak van die ontwerppunt spesifikasies van 'n 1/6 skaal verwysingswaaier. Twee eksperimentele waaiers is ontwerp deur middel van die ontwerpmetode en getoets volgens die BS 848, Type A kode. Die ontwerpmetode maak gebruik van die eenvoudig radiale ewewigsvergelykings en 'n stel rekenaarprogramme. Die twee eksperimentele waaiers het dieselfde naaf-huls verhouding en werwel verdeling, maar verskil daarin dat verskillende vleuelprofiele gebruik is vir elkeen van die twee waaiers. Die eerste ontwerp maak gebruik van die bekende Clark-Y profiel terwyl die tweede die moderne NASA LS profiel gebruik. Die karakteristieke van die twee eksperimentele waaiers is gemeet oor die hele werkbereik en vergelyk met die verwysings waaier waardeur die geldigheid en akkuraatheid van die ontwerpmetode bepaal is. Die werkverigting van die eksperimentele waaiers vergelyk goed met die verwysingswaaier en bevredig die ontwerpsdoelwitte.
37

An evaluation of a design method for mixed flow fans

Du Toit, Jacques H. (Jacques Hendrik) 03 1900 (has links)
Thesis (MScEng)--University of Stellenbosch, 2002. / ENGLISH ABSTRACT: Mixed flow fans find application in an operating region between that of axial flow and centrifugal fans. The candidate investigated the working of these mixed flow fans and formulated a design algorithm. The algorithm was based on work done by previous authors, most of which have tried to modify existing axial flow fan design methods to suit the mixed flow case. A fan was designed, built and tested. Tests showed that the fan did not perform as designed, producing a lower pressure rise at a lower flow rate. A five hole probe was used to measure the exit flow vector and the results showed that most of the work was done by the lower half of the blade. Based on this discrepancy between the designed and actual fan performance, a number of changes to the design procedure were recommended. Amongst other things: the use of numerical blade modelling procedures instead of modified cascade correlations and the disregard of the Coriolis work in the design of the blade shape. / AFRIKAANSE OPSOMMING: Gemengde vloei waaiers bevredig die behoefte aan 'n waaier in 'n spesifieke werksgebied waar aksiaal en sentrifugale waaiers minder effektief is. Die projek ondersoek die werking van gemengde vloei waaiers en formuleer 'n ontwerp-algoritme. Die algoritme is gebaseer op bestaande navorsing, waarvan die meeste 'n poging is om aksiaalvloeiwaaiermetodes aan te pas vir die gemengde vloei geval. 'n Waaier is ontwerp, gebou en getoets. Toetsresultate toon dat die waaier 'n laer drukstyging by 'n laer volume vloei gee as wat die ontwerp voorspel. 'n Vyfgat-anemometer is gebruik om die uitlaatvloei-vektor te meet en die resulate het bewys dat die gedeelte van die rotorlem naaste aan die naaf meeste van die werk doen. Hierdie afwyking van die ontwerptoestand is ondersoek en 'n aantal veranderings aan die ontwerp algoritme is voorgestel, naamlik: die gebruik van numeriese lemprofiel simulasie, instede van die glip- en deviasie- modelle, en die ontwerp van die lemprofiel deur die Coriolis werk te Ignoreer.
38

The effectiveness of axial flow fans in a-frame plenums

Venter, Sarel Jacobus, Kroger, D. G. 03 1900 (has links)
Thesis (PhD (Mechanical and Mechatronic Engineering)--University of Stellenbosch, 1990. / 260 leaves printed single pages, preliminary pages i-xxi and numbered pages Chapter 1/1.1-1.3, Chapter 2/2.1-2.17, Chapter 3/3.1.1-3.10, Chapter 4/4.1-4.18, Chapter 5/5.1-5.3, References pages R.1-R.7, Appendix A pages A.1-A.34, Appendix B pages B.1-B.34, Appendix C pages C.1-C.26, Appendix D pages D.1-D.16, Appendix E pages E.1-E.30, Appendix F pages F.1-F.39. Includes bibliography, list of tables, figures and symbols. / Digitized at 600 dpi grayscale to pdf format (OCR), using a Bizhub 250 Konica Minolta Scanner. / ENGLISH ABSTRACT: The ultimate goal of this project is to ensure a better understanding of the governing mechanisms present when flow distorting components are installed in close proximity of an axial flow fan. The effect of different parameters on the operation of axial flow fans is investigated. These parameters are divided into flow enhancing and flow reduction effects. The performance of an axial flow fan can be enhanced by changing the tip clearance, by adding a solid disc to the hub of the fan or by varying the number of fan blades. Flow reductions are caused by components such as inlet grids, walkways and their supporting structures, heat exchangers and windwalls. The effects of flow enhancing components are measured and compared to the results of other authors. The sensitivity of these effects to parameters such as the type of fan rotor and the specific system in which the rotor is installed is highlighted. The system effect (the interaction between the fan rotor and flow resistances in close proximity of each other) of individual components, as well as the combination of different components, is predicted both theoretically and experimentally. These predictions are compared to measured data relevant to the components in an installation where the system effects are present. The results are correlated to the kinetic energy flux coefficient of the flow at different locations within the installation. Experimental data obtained from a full scale unit (inlet shroud diameter of 9,216 m) are used to compare to scaled data from the model (inlet shroud diameter of 1,542 m). The hub to tip ratio of the axial flow fans investigated is 0,15. The most important conclusions are that the performance of the type of axial flow fan under investigation can be improved by reducing its tip clearance and by installing a solid disc to the downstream side of the rotor. An increase in the number of blades of the fan leads to only marginal improvements in the fan performance. The overall performance of the system can also be improved by removing some of the flow resisting components, or by changing their relative positions. All these conclusions are based on the assumption that the power input to the fan rotor remains constant. / AFRIKAANSE OPSOMMING: Die uiteindelike doel van hierdie projek is om te verseker dat die beherende meganismes wat teenwoordig is wanneer vloeiversteurende komponente in die nabyheid van 'n aksiaalwaaier geinstalleer word, beter verstaan word. Die effek van verskillende parameters op die werkverrigting van aksiaalwaaiers word ondersoek. Hierdie parameters word verdeel in vloeiverbeterings- en vloeiverminderingseffekte. Die werkverrigting van 'n aksiaalwaaier kan verbeter word deur die lempuntspeling te verstel, deur 'n soliede skyf aan die naaf van die waaierrotor te installeer, of deur die aantal lemme te verander. Die vloeiverminderings word veroorsaak deur inlaatsiwwe, loopvlakke en hul ondersteuningsstrukture, warmteruilers en windwande. Die effekte van vloeiverbeteringskomponente word gemeet en vergelyk met die resultate van ander outeurs. Die sensitiwiteit van hierdie effekte op parameters soos die tipe rotor en die spesifieke stelsel waarin die rotor geinstalleer is, word uitgelig. Die stelseleffek (die interaksie tussen die rotor van die waaier en vloei weerstande wat naby mekaar geinstalleer is) van individuele, sowel as 'n kombinasie van verskillende komponente, word teoreties en eksperimenteel voorspel. Hierdie voorspellings word dan vergelyk met eksperimentele data wat van toepassing is op die komponente in 'n installasie waar stelseleffekte voorkom. Die resultate word gekoppel aan die kinetiese energievloedkoeffisient van die vloei by verskillende posisies binne die installasie. Eksperimentele data, verkry vanaf 'n volskaaleenheid (inlaatmondstukdiameter van 9,216 m), word met die geskaleerde data van die model (inlaatmondstukdiameter van 1,542 m) vcrgelyk. Die naaf- tot hulsverhouding van die aksiaalwaaiers wat ondersoek word is 0,15. Die belangrikste gevolgtrekkings is dat die werkverrigting van die tipe aksiaalwaaier wat ondersoek word verbeter kan word deur die lempuntspeling te verminder en deur 'n soliede skyf te installeer by die stroomaf kant van die rotor. 'n Toename in die aantal lemme van die waaier lei slegs tot marginale verbeterings in die werkverrigting van die waaier. Die totale werkverrigting van die stesel kan ook verbeter word deur sommige vloeiweerstandskomponente te verwyder, of deur hulle relatiewe posisies te verander. Al hierdie gevolgtrekkings is gebasseer op die aanname dat die drywingsinset na die waaierrotor konstant bly.
39

Using Motor Electrical Signature Analysis to Determine the Mechanical Condition of Vane-Axial Fans

Doan, Donald Scott 08 1900 (has links)
The purpose of this research was a proof of concept using a fan motor stator as transducer to monitor motor rotor and attached axial fan for mechanical motion. The proof was to determine whether bearing faults and fan imbalances could be detected in vane-axial fans using Motor Electrical Signature Analysis (MESA). The data was statistically analyzed to determine if the MESA systems could distinguish between baseline conditions and discrete fault frequencies for the three test conditions: bearing inner race defect, bearing outer race defect, and fan imbalance. The statistical conclusions for these proofs of concept were that MESA could identify all three faulted conditions.
40

Effects of Fan Cooling at Room Temperature on Indoor 20-km Cycling Time Trial Performance

Bloom, Matthew 05 July 2018 (has links)
Aim: The primary purpose of this study was to examine effects of a fan-induced airflow at standard room temperature (20-23°C) on 20-km cycling time trial performance. A secondary purpose was to investigate two fan speeds and whether a difference in performance existed with increased fan speed in intermediate duration indoor cycling tests. Methods: Seven trained cyclists completed three 20-km cycling time trials under three conditions in a randomized crossover design. The 3 conditions were: 1) control (no fan), 2) low speed fan, and 3) high speed fan. Results: A tendency for modest decreases in time to completion (TTC) were noted in the two experimental conditions compared to the control condition (-2.06% low speed fan; -3.29% high speed fan). There was also a tendency for small increases in power output during the experimental conditions, although neither time nor power output differences were statistically significant. No differences in mean heart rate and rating of perceived exertion were observed among the three conditions. Conclusion: These results suggest a relationship between fan use and 20-km indoor cycling time trial performance, specifically TTC and mean power output, but larger samples are needed to provide adequate statistical power. Further investigation into the effects of fan use in standard testing environments is recommended. No additional benefit was observed from increased fan speeds. Differences in the experimental conditions on average resulted in non-significant 1.2% improvement.

Page generated in 0.0552 seconds