Spelling suggestions: "subject:"case estacionário monolítica"" "subject:"base estacionário monolítica""
1 |
Construção de dispositivos de pressurização e de aquecimento para a preparação e funcionalização de fases estacionárias monolíticas via processo sol-gelRibeiro, Sandro Pereira 06 August 2015 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-09T12:20:47Z
No. of bitstreams: 1
sandropereiraribeiro.pdf: 1843700 bytes, checksum: 116a82b85c5101d893b55d6830abb954 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-01-23T11:18:44Z (GMT) No. of bitstreams: 1
sandropereiraribeiro.pdf: 1843700 bytes, checksum: 116a82b85c5101d893b55d6830abb954 (MD5) / Made available in DSpace on 2018-01-23T11:18:44Z (GMT). No. of bitstreams: 1
sandropereiraribeiro.pdf: 1843700 bytes, checksum: 116a82b85c5101d893b55d6830abb954 (MD5)
Previous issue date: 2015-08-06 / No presente trabalho foi proposto a compreensão das variáveis inerentes à criação de infraestrutura adequada para preparação de fase estacionária monolítica (FEM) utilizando colunas capilares de 100 mm de diâmetro interno para aplicação em electroromatografia capilar (CEC). A fim de alcançar a elucidação do processo de funcionalização do monolíto, as FEM foram produzidas por química de sol-gel. Neste caso, a mistura otimizada de reagentes origina o sol que muda de um estado líquido para o estado de gelificação no interior do tubo capilar, resultando em uma superfície polimérica. Dentro deste contexto, foi desenvolvido um dispositivo manual para alta pressão (DMAP) para a inserção do sol nas colunas capilares. O DMAP à vácuo montado foi desenvolvido no Grupo de Química Analítica e Quimiometria (GQAQ) a fim de tornar possível a produção de colunas monolíticas de maneira otimizada e reprodutível. Este dispositivo tornou possível o preenchimento interno da coluna capilar de forma homogênea através do trabalho forçado em movimento, como capilaridade, na qual o sol é introduzido diretamente do frasco ao capilar, evitando o contato do sol com acessórios e dispositivos, como conexões, seringas e agulhas. Como objetivo secundário, estudos para preparação das FEM modificadas por nanopartículas de ouro- AuNps foram realizadas. As AuNps foram sintetizadas através da reação de redução com o citrato de sódio e a passivação com o uso da quitosana. As nanopartículas foram ancoradas na superficie do monolito para melhorar a funcionalização das FEM e possibilitar testes com diversos analitos. Essa reação foi caracterizada por Microscopia Eletrônica de Transmissão- MET, Microscopia Eletrônica de Varredura- MEV, Ultravioleta Visível- UV-Vis. Nesse mesmo tempo foi montado um segundo dispositivo denominado mini-forno para aquecimento radial homogénea do tubo capilar, a fim de atingir a funcionalização adequada. Finalmente, todas as colunas preparadas e funcionalizadas com sucesso foram submetidas a testes de separação de mistura padrão de HPAs. / In the present work the understanding of the inherent variables to establishment of adequate infrastructure to monolithic stationary phase (MSP) preparation using capillary columns at 100 μm of internal diameter to application in capillary electrocromatography (CEC) was proposed. Thus, in order to achieve the elucidation of the monolithic functionalization process, the MSP were produced by sol-gel chemistry. In this case, the optimized mixture of reagents originates the sol which changes from liquid state to the jellification state inside the capillary tube, resulting in a polymeric surface. Within this context, was developed a manual device to high pressure (MDHP) for sol insertion into the capillaries columns. The vacuum MDHP assembled was developed in the Grupo de Química Analítica e Quimiometria (GQAQ) in order to make possible the optimized and reproducible monolithic columns production. This device made possible the internal fill of the capillary column in homogenous way through of forced moving such as capillarity, in which the sol is introduced direct from the vial to the capillary, avoiding the contact of the sol with accessories and devices such as connections, syringes and needles. This procedure avoids air passage into the capillary tube and the contamination of devices and accessories, providing the operation in presence of any type of solution. Thus, the MDHP became possible a significant advance in the understanding of the MSP preparation mediated by sol-gel chemistry and photopolimerization. As a secondary objective, studies to preparation of MSP modified by gold nanoparticles were carried out. In this same time was assembled a second device called mini oven to homogeneous radial heating of the capillary in order to achieves the adequate functionalization. Finally, all columns prepared and functionalized with success were submitted to tests of HPAs standard mixture separation.
|
2 |
Caracterização não invasiva de fase estacionária monolítica para uso em eletrocromatografia capilar e nano-cromatografia a líquidoMarques, Rafael 29 September 2017 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-01-09T14:43:53Z
No. of bitstreams: 1
rafaelmarques.pdf: 2550703 bytes, checksum: 4694887625f47f1d8d4f3dbed5d78f1d (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-01-23T11:20:19Z (GMT) No. of bitstreams: 1
rafaelmarques.pdf: 2550703 bytes, checksum: 4694887625f47f1d8d4f3dbed5d78f1d (MD5) / Made available in DSpace on 2018-01-23T11:20:19Z (GMT). No. of bitstreams: 1
rafaelmarques.pdf: 2550703 bytes, checksum: 4694887625f47f1d8d4f3dbed5d78f1d (MD5)
Previous issue date: 2017-09-29 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta tese de doutorado aborda o preparo, a caracterização e a utilização de
fases estacionárias monolíticas para uso em colunas de separação
cromatográfica em escala capilar. As fases estacionárias foram preparadas pela
polimerização do monômero 3-(metacriloxipropil)-trimetoxisilano em duas etapas
envolvendo primeiramente um processo sol-gel e depois um processo de adição
radicalar fotoiniciado. A fotopolimerização foi feita in situ em capilares de sílica
fundida transparentes à radiação UV com 100 μm de diâmetro interno. As
colunas produzidas foram aplicadas qualitativamente com sucesso na separação
de cinco hidrocarbonetos policíclicos aromáticos e três hormônios esteroides,
tanto por cromatografia a líquido capilar quanto por eletrocromatografia capilar
em um equipamento de eletroforese capilar. A eletrocromatografia foi usada para
analisar quantitativamente uma amostra de emulsão transdérmica contendo
estriol e 17-β-estradiol. Como tentativa de melhorar a separação entre alguns
analitos, foi feita a modificação do polímero adicionando o monômero benzil
metacrilato, porém sem sucesso. As colunas foram caracterizadas com relação
à sua homogeneidade física usando um microscópio óptico e um detector
condutométrico sem contato capacitivamente acoplado. O detector foi usado
como um scanner não invasivo deslocando-se longitudinalmente ao longo da
coluna externamente ao capilar. A caracterização química do polímero foi feita
através da espectroscopia de ressonância magnética nuclear no estado sólido
dos núcleos de 13C e de 29Si. Foi possível propor uma estrutura para o arranjo
da cadeia carbônica e o grau de substituição do grupo silil indicando a reticulação
das cadeias poliméricas através da formação de dímeros e trímeros
condensação de grupos alcoxisilanos. / This doctoral thesis adresses the preparation, characterization and use of
monolithic stationary phases for chromatographic separation columns in capillary
scale. The stationary phases were prepared by polymerizing the 3-
(methacryloxypropyl) trimethoxysilane monomer in two steps involving a sol-gel
process followed by a photoinitiated radical addition. The photopolymerization
was carried out in UV transparent coating fused silica capillaries with 100 μm of
internal diameter. The columns were applied in the qualitative separation of five
polycyclic aromatic hydrocarbons and three steroid hormones, both by capillary
liquid chromatography and capillary electrochromatography in a capillary
electrophoresis equipment. Electrochromatography was used to quantitative
analyzis of a transdermal emulsion sample containing estriol and 17-β-estradiol.
In an attempt to improve the separation between some analytes, the polymer was
modified by adding the benzyl methacrylate monomer, but without success. The
columns were characterized with respect to their physical homogeneity using an
optical microscope and a capacitively coupled contactless conductivity detector.
The detector was used as a non-invasive scanner moving longitudinally along the
column externally to the capillary. The chemical characterization of the polymer
was done by the solid state 13C and 29Si nuclear magnetic resonance
spectroscopy. It was possible to propose a carbon chain strucuture and the
substitution degree of the silyl group indicating the cross-linking of the polymer
chains through the formation of dimers and trimers by condensation of the
alkoxysilane groups.
|
3 |
Preparação de novas fases estacionárias monolíticas para uso em eletrocromatografia capilarVaz, Fernando Antonio Simas 22 July 2011 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-04-27T12:33:46Z
No. of bitstreams: 1
fernandoantoniosimasvaz.pdf: 40063052 bytes, checksum: f272ddc4d930b7d243c50223436e02b2 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-05-13T13:00:49Z (GMT) No. of bitstreams: 1
fernandoantoniosimasvaz.pdf: 40063052 bytes, checksum: f272ddc4d930b7d243c50223436e02b2 (MD5) / Made available in DSpace on 2017-05-13T13:00:49Z (GMT). No. of bitstreams: 1
fernandoantoniosimasvaz.pdf: 40063052 bytes, checksum: f272ddc4d930b7d243c50223436e02b2 (MD5)
Previous issue date: 2011-07-22 / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Nesta tese é descrita a preparação de novas fases estacionárias monolíticas
(FEM) polimerizadas por fotoiniciação, através do método sol-gel, em capilares de
sílica fundida revestidos com poliacrilato, para aplicação em eletrocromatografia
capilar (ECC). Dentre as principais técnicas de separação em Química Analítica, a
ECC tem despertado grande interesse no meio acadêmico, pelo fato desta combinar
as vantagens tanto da cromatografia a líquido de alta eficiência quanto da
eletroforese capilar. Grande parte do desenvolvimento da ECC se deve ao uso das
FEM, as quais são semelhantemente aplicadas em outras técnicas cromatográficas.
Ao contrário do revestimento de poliimida, amplamente empregado, o revestimento
de poliacrilato, transparente acima de 370 nm e à luz visível, facilita a visualização
da solução de sol no interior do capilar, o que permite controlar a injeção desta e de
outras soluções, bem como observar a formação in situ da FEM. Além disso, é
possível que seja feita a polimerização fotoiniciada sem a necessidade de remoção
do revestimento polimérico que protege a coluna. O objetivo central deste trabalho
foi entender e aprimorar o processo de fabricação das FEM para aplicações em
ECC. Para isso, foram feitas modificações da câmara fotorreatora homemade
utilizada para a polimerização das FEM, como uma correção na faixa espectral de
trabalho de 350 a 700 nm para 350 a 400 nm; e instalação de dispositivos de
segurança tanto para o operador quanto para o sistema elétrico. Para que fosse
alcançado um melhor controle de injeção de fases líquidas no interior de tubos com
dimensões capilares, a construção de um dispositivo de alta pressurização (DAP)
que forneceu, além da pressão, grande precisão foi indispensável. O DAP, além de
simples, teve ótima relação custo-benefício, comparado a modelos comerciais. O
preparo das FEM foi otimizado mediante auxílio de planejamento fatorial fracionário 24-1, onde se buscou analisar propriedades eletrocromatográficas frente diferentes
proporções dos reagentes empregados e tempo de incidência de luz ultravioleta
(UV). Este último fator não apresentou significância e foi desconsiderado, de forma
que o planejamento fosse devidamente reduzido para um planejamento fatorial completo 23, o que possibilitou uma análise mais apurada dos efeitos significativos.
O fator mais influente foi a proporção de porogênio (tolueno), sendo que a melhor
condição obtida foi utilizando 80,0 % (v/v) de solução porogênica; 3,5 % (m/m) de
fotoiniciador óxido de bis(2,4,6-trimetilbenzoil)-fenilfosfino (Irgacure 819); razão
molar água/ metacriloxipropiltrimetoxisilano (MPTMS) igual a 4 e tempo de incidência
de luz UV de 10 minutos. As características morfológicas, espectroscópicas e
porosidade foram avaliadas através de microscopia eletrônica de varredura,
infravermelho e porosimetria por adsorção de nitrogênio, respectivamente. As FEM
foram testadas em ECC pela separação de hidrocarbonetos policíclicos aromáticos
(naftaleno, acenafteno, fluoreno, fenantreno e antraceno) e alquilbenzenos
(etilbenzeno, propilbenzeno, butilbenzeno e hexilbenzeno), todos compostos eletricamente neutros, diluídos em metanol (1 mmol L-1 cada), utilizando tiouréia
como marcador de fluxo. Como fase móvel foi utilizada a mistura de acetato de amônio 16,7 mmol L-1 pH 7,0 (60 %) e acetonitrila (40 %). A voltagem aplicada foi
-20 kV; a temperatura de análise foi 20 ºC; a injeção dos analitos foi -25 mbar por
5 s; e a detecção no UV foram nos comprimentos de onda de 220 nm e 250 nm. Foi
utilizado o modo ECC-rápida, que consiste na inversão do sentido de análise e
injeção de padrões pela extremidade curta do capilar. Este modo se mostrou muito
mais rápido, repetitivo e eficiente do que o modo normal, fornecendo em pouco mais
de 12 minutos de análise, mais de 51400 pratos/m de coluna e desvios padrão
relativos em tempo de migração/retenção entre 0,09 e 3,3 % e em área de pico
relativa entre 0,14 e 1,6 %. Os perfis de separação em ECC corroboraram com os
resultados de porosidade e morfologia obtidos. / This thesis describes the preparation of new monolithic stationary phases
(MSP) polymerized by photoinitiation through sol-gel approach in polyacrylate-coated
fused silica capillary, for application in capillary electrochromatography (CEC). CEC
has been concentrated much attention among the major separation techniques in
analytical chemistry because it combines the advantages of both high performance
liquid chromatography and capillary electrophoresis. Much of the CEC development
is due to the use of MSP, which are similarly applied to other chromatographic
techniques. Unlike polyimide-coating, widely used, the polyacrylate-coating, which is
transparent above 370 nm and visible, enables the visualization of the sol solution
within the capillary, allowing one to control the injection of sol and other solutions, in
addition to observe the in situ formation of the MSP. Furthermore, it is possible to
perform the photoinitiated polymerization without removing this polymeric coating that
protects the capillary. The main purpose of this work was to comprehend and
improve the fabrication process of MSP, for CEC applications. For this, some
changes were set in the homemade photo reactor chamber, used for the MSP
polymerization, like correction in the work range from 350 – 700 nm to 350 – 400 nm;
and installation of security devices for both operator and electric system safeties. For
better control of liquid phases injection within tubes with capillary dimensions, the
build of a high-pressure device (HPD) that provides a great precision, in addition to
the high-pressure, was essential. HPD is simpler and relatively cheaper when
compared to commercial models. The preparation of the MSP has been optimized through assistance of a 24-1 fractional factorial design, with the intention to investigate
electrochromatographic properties with different amounts of employed reagents and
ultraviolet (UV) light incidence time. The later factor did not show significance and was unconsidered, making the design possible to be reduced to a 23 complete
factorial design, which allowed analyzing the significant effects accurately. The most
influent factor was the porogen (toluene) proportion, and the best condition was
obtained using 80.0 % (v/v) of porogenic solution; 3.5 % of photoinitiator bis(2,4,6
trimetylbenzoyl)-phenylphosphine oxide (Irgacure 819); water to
metacryloxypropyltrimethoxysilane (MPTMS) molar ratio equal to 4 and 10 minutes of
UV light incidence time. The MSP morphological, spectroscopic characteristics and
porosity were evaluated through scanning electron microscopy, infrared spectroscopy
and nitrogen adsorption porosimetry, respectively. The MSP has been tested in CEC
through the separation of polycyclic aromatic hydrocarbons (naphthalene,
acenaphthene, fluorene, phenanthrene and anthracene) and alkylbenzenes
(ethylbenzene, propylbenzene, butylbenzene and hexylbenzene), which are electrically neutral compounds, after dilution in methanol (1 mmol L-1 each), using
thiourea as the flow marker. As mobile phase a mixture of ammonium acetate 16.7 mmol L-1 at pH 7.0 (60.0 %) and acetonitrile (40.0 %) was used. The applied
voltage was -20 kV, the temperature of analysis was 20 °C, the analyte injection was
-25 mbar for 5 s, and UV detection was done at 220 and 250 nm. A fast-CEC mode,
which consists to reverse the analysis direction and to introduce the analyte by
capillary short-end injection, was performed. This mode was much more fast,
repetitive and efficient than the normal one, providing in a little more than 12 minutes
over than 51400 plates per meter of column and relative standard deviations ranging
from 0.09 to 3.3 % for migration/retention time and from 0.14 to 1.6 % for relative
peak area. The separation profiles in CEC corroborate with the porosity and
morphology results.
|
Page generated in 0.1094 seconds