171

Estimating the dynamic sensitive cross section of an FPGA design through fault injection /

Johnson, Darrel E., January 2005 (has links) (PDF)
Thesis (M.S.)--Brigham Young University. Dept. of Electrical and Computer Engineering, 2005. / Includes bibliographical references (p. 105-108).
172

Multivariate fault detection and visualization in the semiconductor industry

Chamness, Kevin Andrew, January 1900 (has links) (PDF)
Thesis (Ph. D.)--University of Texas at Austin, 2006. / Vita. Includes bibliographical references.
173

Fault location for power transmission systems using magnetic field sensing coils

Ferreira, Kurt Josef. January 2007 (has links)
Thesis (M.S.) -- Worcester Polytechnic Institute. / Keywords: power systems; power transmission; fault location. Includes bibliographical references (leaves 83-84).
174

Wireless sensor network fault localization /

Qin, Mian. January 2008 (has links)
Thesis (M.Phil.)--Hong Kong University of Science and Technology, 2008. / Includes bibliographical references (p. 58-62).
175

Localização de faltas em redes de distribuição de energia elétrica com geradores distribuídos /

Levano Vergara, Raul Alejandro January 2017 (has links)
Orientador: José Roberto Sanches Mantovani / Resumo: Neste trabalho apresenta-se uma metodologia para a localização de faltas em alimentadores de distribuição de energia elétrica através do uso de técnicas de análise de redes baseadas na matriz de impedância e circuitos elétricos. A partir de medidas de tensão e corrente na saída do alimentador e medidas de tensão esparsas no alimentador o algoritmo é capaz de identificar e localizar faltas em alimentadores trifásicos radiais ou fracamente malhados, com cargas desequilibradas, ramais laterais trifásicos, bifásicos ou monofásicos e que tenham geração distribuída representada como uma barra de tensão controlada e que possua medidores de tensão. O sistema de diagnóstico e localização de faltas proposto é capaz de auxiliar as concessionárias de energia em sua rotina de trabalho, fornecendo informações importantes para a operação e manutenção dos sistemas elétricos de distribuição de energia, minimizando os tempos de reparos e, consequentemente, obtendo-se menos perdas financeiras devido ao rápido diagnóstico de faltas e restabelecimento das condições normais de operação. Um sistema de distribuição trifásico real de 135 barras, tensão nominal de 13,8 kV e potência nominal de 7,065 MVA foi utilizado para testar o algoritmo proposto, que apresenta resultados satisfatórios, mostrando-se ser um algoritmo eficiente e rápido. / Mestre
176

Distribution Grid Fault Location : An Analysis of Methods for Fault Location in LV and MV Power Distribution Grids

von Euler-Chelpin, Jonas January 2018 (has links)
Outages and power interruptions are a common and unenviable part of power distribution system operations. Growing demands on reliability in distribution systems has opened up for new technological solutions for fault location at MV and LV level in distribution systems, previously reserved for transmission systems. This report compiles and compares available methods for fault location at distribution level and maps the current fault location process at the power distribution company Ellevio, with the aim of reaching a recommendation for a new fault location scheme. The advocated method is an impedance based method motivated by its reliability, applicability and affordability. The performance and implementation procedure is evaluated through a number of case studies where the methods impact on power reliability demonstrated as well as the need for grid analysis before implementation. Fault indicators and fault current, through relay communications, was identified as key factors for a successful implementation of the method.
177

Formulação integrada para a localização de faltas em sistemas de distribuição

Rodríguez Paz, Martín Cruz January 2010 (has links)
Neste trabalho apresentar-se-à um novo método para a localização de faltas em Sistemas de Distribuição de Energia Elétrica. Este combina duas técnicas, uma baseada na Impedância Aparente e outra nas Ondas Viajantes. A técnica de localização por impedância aparente utiliza o sinal armazenado pelo relé, analisando-o na sua frequência fundamental. O resultado desta análise é a estimativa da distância da falta. Esta representa a distância elétrica desde o rele até a falta, o que em sistemas de distribuição radiais, com laterais, pode gerar mais de uma resposta como certa. A técnica das ondas viajantes é utilizada para a localização da seção faltosa utiliza os sinais de alta frequência presentes no sinal. O resultado desta análise é a estimativa da seção onde ocorreu a falta. Assim, estas duas técnicas complementam-se para fornecer a posição da falta. / This work presents a new hybrid method to Fault Location in Power Distribution Systems. This work combines two techniques, one based on Apparent Impedance and the other based on Traveling Waves. Apparent Impedance based methods use the signals stored in the relay. That signals are analyzed in their fundamental frequency. It is obtained as result the distance from sub-station to the fault. This distance represents the electrical distance from the sending end to the fault, but in Power Distribution Systems with several laterals these fault location could be more than one. The Traveling waves method use the high frequencies presents in faulted signals. Obtain with this the faulted section. Thus both techniques are complements, resulting in only one distance to the fault point.
178

Novos desenvolvimentos na localização de faltas em sistemas de distribuição de energia elétrica fundamentada na impedância

Salim, Rodrigo Hartstein January 2008 (has links)
Apesar do crescente desenvolvimento das metodologias de localização de faltas fundamentadas na impedância para sistemas de distribuição de energia elétrica nas últimas décadas, alguns aspectos ainda carecem de progressos, especialmente frente à crescente necessidade de aumento da qualidade da energia elétrica entregue aos consumidores. Um destes aspectos diz respeito à consideração da capacitância das linhas de distribuição, efeito nunca dantes considerado para este fim pelas metodologias baseadas em impedância aparente. Assim sendo, o presente trabalho apresenta novos desenvolvimentos relativos à consideração do efeito capacitivo para as metodologias de localização de faltas fundamentadas na impedância para sistemas de distribuição de energia elétrica. O principal desenvolvimento apresentado é um novo equacionamento para fins de localização de faltas, que torna necessária a apresentação de outro desenvolvimento, o de um algoritmo de localização de faltas que considere a capacitância da linha. As novas equações são apresentadas para todos os tipos de faltas e constituem-se de equações polinomiais de segunda ordem em relação ao local da falta. De forma a entender a resposta destas equações frente a diferentes casos de faltas e determinar qual a solução fisicamente correta destas equações, as mesmas são analisadas sob três pontos de vista, a saber, matemático, físico, e numérico. Inicialmente estas equações são analisadas de forma analítica considerandose faltas em um mesmo local, mas com resistências diferentes. Posteriormente a mesma análise é realizada numericamente através de simulações computacionais. Os desenvolvimentos propostos são também submetidos a testes de faltas, simuladas computacionalmente em um sistema sem laterais ou cargas intermediárias. Os resultados obtidos são comparados frente a resultados obtidos também para outras metodologias que constituem atualmente o estado da arte em localização de faltas fundamentada na impedância para sistemas de distribuição de energia elétrica. Através destes resultados é possível mostrar a grande influência que o efeito capacitivo possui nestas metodologias, mesmo em sistemas aéreos de distribuição, e elucidar as grandes melhorias obtidas através dos desenvolvimentos propostos. / Despite the increasing development of impedance-based fault location techniques for electric power distribution systems in the last decades, some aspects still require to progress, especially with the increasing necessity of power quality enhancement. One of these aspects regards to the distribution line shunt admittance consideration, effect that has never been considered before by the impedance-based fault location methods for power distribution systems. In this way, this work presents further improvements regarding the capacitive effect consideration for impedance-based fault location methods for power distribution systems. The main improvement presented is the development of new fault location equations, which yield the necessity of another improvement, a modified fault location algorithm that also considers the line shunt admittance. The new equations are presented for all fault types and are constituted by second-order polynomials in relation to the fault location. In order to understand the response from these equations regarding different fault situations and determine which solution is the physically feasible one, these equations are analyzed from three different points of view, i.e., mathematical, physical, and numerical. First, the developed equations are analytically analyzed considering faults in one location with different fault resistances. After, the same analysis is numerically carried out through computational simulations. The performance of the proposed improvements are also evaluated through computational simulations of faults in a power distribution system without laterals or intermediate loads. The obtained results are compared with results from the current state-of-the-art impedance-based fault location methodologies for power distribution systems. Through these results it is possible to show the great effect that the line shunt admittance, even in aerial distribution systems, has on the existing fault location methodologies and also the great improvements brought by the proposed developments.
179

Localização de faltas para sistemas de distribuição ativos : metodologia analítica adaptativa baseada na estimativa da impedância aparente

Orozco-Henao, Cesar Augusto January 2016 (has links)
Este documento apresenta uma metodologia analítica adaptativa para localização de faltas baseada na estimativa da impedância para sistemas de distribuição ativos. A metodologia proposta combina a informação fornecida por dispositivos eletrônicos inteligentes alocados na subestação principal e nos terminais de cada unidade de Recurso Energético Distribuído (do inglês Distributed Energy Resources - DER), o conhecimento da topologia da rede e os seus parâmetros para estimar a localização da falta. A característica adaptativa é dada pelo uso de modelos elétricos lineares para considerar o efeito das DER conectadas à rede, quando a informação fornecida pelos Dispositivos Eletrônicos Inteligentes (do inglês Intelligent Electronic Devices - IED) não é disponível. Adicionalmente, uma estratégia baseada na técnica Ladder é desenvolvida para estimar a contribuição de corrente desde as DER até o ponto de falta. Esta estratégia permite considerar vários geradores conectados e seus diferentes modos de operação. A metodologia proposta foi validada com o sistema IEEE 34 barras. Este sistema foi modelado no Alternative Transients Program (ATP) e modificado pela inserção de várias unidades DER. A metodologia proposta foi validada em vários cenários. Estes cenários avaliam o efeito da distância até a falta, resistência da falta, incerteza na carga, nível de penetração de DER, número de geradores conectados e erros nas medidas ou na estimação dos parâmetros das DER quando seus modelos forem utilizados. Para estas considerações, o desempenho da formulação proposta é satisfatório, apresentando erros menores do que 3%. / This document presents an adaptive analytical impedance-based fault location methodology for active distribution systems. The proposal combines information provided by Intelligent Electronic Devices (IEDs) located in the substation, each Distributed Energy Resources units terminal, the knowledge of the network topology as well as its parameters to estimate the fault location. Its adaptive feature is given by the use of linear analytical equivalent models to consider of DER effect in case the information provided by a local IED is not available. Additionally, a ladder-based technique is proposed to estimate the current contribution from of DER to the fault point. This process allows considering several DER connected and their different operation modes. The proposed methodology is validated on the IEEE 34-node test feeder. This system is modeled on ATP/EMTP and modified with the insertion of several DER units. The methodology is validated by considering several scenarios. These scenarios evaluate the effect of fault distance, fault resistance, load variation, DER penetration level, numbers of DERs connected and errors in the DER parameters. For these considerations, the proposed methodology performance is satisfactory, presenting fault location errors below 3%.
180

Localização de faltas em sistemas de distribuição de energia elétrica : uma abordagem baseada na análise de transitórios de alta frequência

Peñaloza, Ana Karen Apolo January 2017 (has links)
Os Sistemas de Distribuição de Energia Elétrica (SDEE) estão constantemente expostos à ocorrência de faltas, o que torna de primordial importância para as concessionárias que estas sejam localizadas com rapidez e precisão. Com isso, a degradação da confiabilidade do sistema e as perdas econômicas são minimizadas. Com este intuito, diversas pesquisas vêm sendo conduzidas nas últimas décadas tendo em vista o desenvolvimento de métodos computacionais para Localização de Faltas (LF) em SDEE. Embora as técnicas disponíveis atualmente sejam capazes de estimar a distância das faltas com relativa exatidão, algumas características intrínsecas aos SDEE ainda impõem limitações à LF em alimentadores radiais. Em geral, o aspecto econômico requer o uso de dados provenientes de um único terminal de medição. Ainda, a quantidade significativa de ramais laterais tipicamente presentes nos SDEE faz com que o problema das múltiplas estimativas da LF seja considerado como a principal limitação à efetividade das técnicas existentes na atualidade. Neste contexto, este trabalho apresenta uma metodologia baseada na análise dos transitórios de alta frequência gerados pelas faltas, a qual é capaz de fornecer uma estimativa única para a LF em SDEE ramificados a partir de medições somente no terminal local. O ramal em falta e a distância da falta em relação ao terminal de medição são determinados através da comparação entre as frequências características identificadas no espectro do transitório, e as frequências teóricas calculadas para os possíveis caminhos de propagação. Uma das principais contribuições deste trabalho consiste na formulação de um modelo detalhado das linhas de distribuição desequilibradas. A formulação proposta é baseada na modificação nas equações de Carson, considerando a dependência da frequência e a inclusão dos efeitos pelicular e da corrente de retorno pela terra para altas frequências. Como resultado, esta abordagem permite uma maior exatidão na determinação dos parâmetros modais que descrevem a propagação de transitórios em SDEE desequilibrados, eliminando as aproximações adotadas pela maioria das técnicas propostas na literatura atual. A técnica proposta foi avaliada considerando simulações de faltas nos alimentadores IEEE 13 e 34 barras através do ATP/EMTP. Os resultados apresentados incluem diversos cenários de faltas, bem como a comparação com um método de LF para SDEE considerado estado da arte atualmente. / Electric power distribution systems (EPDS) are continuously exposed to faults, therefore fast and accurate fault location is of paramount importance for utilities. Thus, degradation of system reliability and economic losses are minimized. In this sense, several studies have been conducted in the last decades aiming to the development of computational methods for Fault Localization (FL) in EPDS. Although the currently available techniques are able to estimate fault distance with relative accuracy, some intrinsic characteristics of EPDS still impose limitations to FL in radial feeders. In general, the economic aspect requires use of data from one-terminal measurements. Also, typical EPDS have a large number of branches, which makes the problem of multiple FL estimates the main limitation to the effectiveness of the existing techniques. In this context, this work presents a methodology based on the analysis of the high frequency transient generated by faults, which is able to provide a unique FL estimate in branched EPDS by using only one-terminal measurements. The faulted branch and the fault distance from the measurement terminal are determined by correlating the characteristic frequencies identified in the transient spectrum and theoretical frequencies calculated for the possible propagation paths. One of the main contributions of this work is the formulation of a detailed model of unbalanced distribution lines. The proposed formulation is based on the modification of Carson’s equations, considering frequency dependence and inclusion of skin effects and the ground current return at high frequencies. As a result, this approach allows a greater accuracy in determining the modal parameters that describe the transients’ propagation in unbalanced EPDS, thus eliminating the approximations adopted by most of the techniques proposed in the current literature. The proposed technique was evaluated considering fault simulations in the IEEE 13 and 34 nodes feeders through the ATP/EMTP. Results presented include several fault scenarios as well as the comparison with a FL method for SDEE currently considered as the state of the art.

Page generated in 0.0683 seconds