• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 106
  • 37
  • 18
  • 14
  • 6
  • 5
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 242
  • 242
  • 53
  • 50
  • 49
  • 48
  • 48
  • 41
  • 32
  • 28
  • 28
  • 28
  • 27
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
241

Contribution au Diagnotic des Défauts de la Machine Asynchrone Doublement Alimentée de l'Eolienne à Vitesse Variable. / Fault diagnosis of a Doubly Fed Induction Generator (DFIG) in a variable speed wind turbine

Idrissi, Imane 21 September 2019 (has links)
Actuellement, les machines Asynchrones à Double Alimentation (MADA) sont omniprésentes dans le secteur éolien, grâce à leur simplicité de construction, leur faible coût d’achat et leur robustesse mécanique ainsi que le nombre faible d’interventions pour la maintenance. Cependant, comme toute autre machine électrique, ces génératrices sont sujettes aux défauts de différent ordre (électrique, mécanique, électromagnétique…) ou de différents types (capteur, actionneur ou composants du système). C’est pourquoi, il est primordial de concevoir une approche de diagnostic permettant de manière anticipée, de détecter, localiser et identifier tout défaut ou anomalie pouvant altérer le fonctionnement sain de ce type de machine. Motivés par les points forts des méthodes de diagnostic de défauts à base d’observateurs, nous proposons d’une part, dans cette thèse, une approche de détection, localisation et identification des défauts de la MADA d’une éolienne à vitesse variable, à base des observateurs de Kalman, performants et largement utilisés. Les erreurs d’estimation d’état du filtre de Kalman linéaire et de ses variantes non-linéaires, à noter : le Filtre de Kalman Etendu (EKF) et le Filtre de Kalman sans-Parfum (UKF), sont utilisés comme résidus sensibles aux défauts. En vue d’éviter les fausses alarmes et de découpler les défauts des perturbations et des bruits, l’analyse des résidus générés est réalisée par des tests statistiques tels que : Test de Page Hinkley (PH) et Test DCS (Dynamic Cumulative Sum). Pour la localisation des défauts multiples et simultanés, la Structure d’Observateurs Dédiés (DOS) et la Structure d’Observateurs Généralisés (GOS) sont appliquées. De plus, l’amplitude du défaut est déterminée dans l’étape d’identification de défaut. Les défauts capteurs, actionneurs et composants de la MADA, sont traités dans ce travail de recherche. D’autre part, une étude comparative entre les différents observateurs de Kalman, est élaborée. La comparaison porte sur les critères suivants : le temps de calcul, la précision et la vitesse de convergence des estimations. / Actually, the Doubly Fed Induction Generators (DFIG) are omnipresent in the wind power market, owing to their construction simplicity, their low purchase cost and their mechanical robustness. However, as any other electrical machine, these generators are subject to defects of different order (electrical, mechanical, electromagnetic ...) or of different type (sensor, actuator or system). That’s why, it is important to design an effective diagnostic approach, able to early detect, locate and identify any defect or abnormal behavior, which could undermine the healthy operation of this machine On the one hand, motivated by the observer-based fault diagnosis methods strengths, we proposed, in this thesis, a diagnostic approach for the faults detection, localization and identification of the DFIG used in variable speed wind turbine. This approach is based on the use of the efficient and widely used Kalman observers. The state estimation errors of the linear Kalman filter and the non-linear Kalman filters, named: The Extended Kalman Filter (EKF) and the Unscented Kalman Filter (UKF) are used as faults sensitive residuals. In order to avoid false alarms and to decouple faults from disturbances and noises, the faults detection is carried out by the analysis of the residuals generated, by the mean of statistical tests such as: Hinkley Page Test (PH) and DCS Test (Dynamic) Cumulative Sum). For the localization step in case of multiple and simultaneous faults, the Dedicated Observer scheme (DOS) and the Generalized Observer scheme (GOS) are applied. In addition, the fault level is determined in the fault identification step. Sensor faults, actuator and system faults of DFIG, are treated in this research work. On the other hand, a comparative study between the three Kalman observers proposed is performed. The comparison was done in terms of (1) the computation time, (2) the estimation accuracy, and (3) the convergence speed.
242

Fault diagnosis of lithium ion battery using multiple model adaptive estimation

Sidhu, Amardeep Singh 12 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Lithium ion (Li-ion) batteries have become integral parts of our lives; they are widely used in applications like handheld consumer products, automotive systems, and power tools among others. To extract maximum output from a Li-ion battery under optimal conditions it is imperative to have access to the state of the battery under every operating condition. Faults occurring in the battery when left unchecked can lead to irreversible, and under extreme conditions, catastrophic damage. In this thesis, an adaptive fault diagnosis technique is developed for Li-ion batteries. For the purpose of fault diagnosis the battery is modeled by using lumped electrical elements under the equivalent circuit paradigm. The model takes into account much of the electro-chemical phenomenon while keeping the computational effort at the minimum. The diagnosis process consists of multiple models representing the various conditions of the battery. A bank of observers is used to estimate the output of each model; the estimated output is compared with the measurement for generating residual signals. These residuals are then used in the multiple model adaptive estimation (MMAE) technique for generating probabilities and for detecting the signature faults. The effectiveness of the fault detection and identification process is also dependent on the model uncertainties caused by the battery modeling process. The diagnosis performance is compared for both the linear and nonlinear battery models. The non-linear battery model better captures the actual system dynamics and results in considerable improvement and hence robust battery fault diagnosis in real time. Furthermore, it is shown that the non-linear battery model enables precise battery condition monitoring in different degrees of over-discharge.

Page generated in 0.0645 seconds