• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 5
  • 4
  • 2
  • 1
  • 1
  • Tagged with
  • 51
  • 51
  • 14
  • 11
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Determining Optimal Fibre-optic Network Architecture using Bandwidth Forecast, Competitve Market, and Infrastructure-efficienct Models used to Study Last Mile Economics

Saeed, Muhammad 20 December 2011 (has links)
The study focuses on building a financial model for a telecommunications carrier to guide it towards profitable network investments. The model shows optimal access-network topography by comparing two broadband delivery techniques over fibre technology. The study is a scenario exploration of how a large telecommunication company deploying fibre will see its investment pay off in a Canadian residential market where cable operators are using competing technology serving the same bandwidth hungry consumers. The comparison is made at the last mile by studying how household densities, bandwidth demand, competition, geographic and deployment considerations affect the economics of fibre technology investment. Case comparisons are made using custom models that extend market forecasts to estimate future bandwidth demand. Market uptake is forecasted using sigmoid curves in an environment where competing and older technologies exist. Sensitivity analyses are performed on each fibre technology to assess venture profitability under different scenarios.
22

Fibre optic pressure transducers for disturbance measurements in transient aerodynamic research facilities

Sharifian, Seyed Ahmad January 2003 (has links)
Experiments in the study of transient aerodynamics typically require pressure measurements with a high spatial and temporal resolution. Existing commercial pressure transducers are expensive and they provide a spatial resolution only on the order of millimetres. The full bandwidth of commercial devices (which extends to around 200 kHz) can only be utilised by exposing the transducer to the flow environment with very little thermal or mechanical protection. If insufficient protection is provided, the expensive commercial devices are likely to be damaged. Inexpensive pressure sensors based on extrinsic Fabry-Perot fibre optic interferometry are capable of measurement with a high spatial and temporal resolution. Thermal protection or isolation for these sensors is still required, but they can be exposed directly to the flow if the sensors are disposable (low cost). Excessive thermal or mechanical protection is not required for these sensors because the damaging heat transfer and particle impacts that may occur in transient aerodynamic facilities generally occur after the useful test flow. In this dissertation, a variety of construction techniques for diaphragm-based Fabry-Perot fibre optic pressure sensors were investigated and the advantages and disadvantages of all techniques are compared. The results indicate that using a zirconia ferrule as the substrate, a liquid adhesive as the bonding layer, and a polished copper foil as the diaphragm provide the best results. It is demonstrated that a spatial resolution on the order of 0.1 mm and a bandwidth to more than 100 kHz can be achieved with such constructions. A variety of problems such as hysteresis, response irregularity, low visibility and sensor non-repeatability were observed. By using a thinner bonding layer, a larger bonding area, longer cavity length, increased calibration period, and applying load cycling to the diaphragm, the hysteresis was minimized. Sensor response irregularity was also minimized using a polished diaphragm. Visibility increased to about 90% using active control of the cavity length during the construction process. Non-repeatability was found to be a consequence of adhesive viscoelasticity and this effect was minimized using a thin layer of adhesive to bond the diaphragm to the substrate. Due to the effects of adhesive viscoelasticity, the pressure sensors indicate an error of up to 10% of mean value for the reflected shock pressure. This error could not be further reduced in the current sensors configuration. Some new configurations are proposed to decrease the effect of sensor non-repeatability. The effect of pretensioning the diaphragm was investigated analytically but the results do not indicate any considerable advantage for the levels of pretension likely to be achieved in practice. However, the results do indicate that pretension effects caused by an environmental temperature change can damage the sensor during storage. The effect of the initial diaphragm deflection on the sensor performance and temperature sensitivity was modelled and the results show that an initial diaphragm deflection can improve the sensor performance. The effect of the thermal isolation layer on the sensor performance was also investigated and the results show that for a shock tube diaphragm bursting pressure ratio up to 5.7, heat transfer does not contribute to sensor errors for the first millisecond after shock reflection. However, it was found that the use of a thin layer of low viscosity grease can protect the sensor for about 20 ms while only decreasing its natural frequency by typically 17%. The grease layer was also found to decrease the settling time of a low damping ratio sensor by 40%. The sensor was successfully employed to identify an acoustic disturbance in a shock tube.
23

Organo-sensitised erbium system for optical amplification at telecommunication wavelength

Ye, Huanqing January 2014 (has links)
The erbium-based optical amplifier (EDFA) plays a vital role in the global fibre-optic telecommunication network. However, there are two main issues with current EDFAs, their bulky size means that they cannot be integrated into silicon-based photonic devices, and they need high pump power to produce optical gain. Here, a potential organo-erbium gain system has been invented, which could be operated under a low pump power and integrated onto a silicon-based device. The fully-fluorinated organic erbium complex [Er(ftpip)3] was mixed with a fully-fluorinated organic zinc complex [Zn(F-BTZ)2], acting as a chromophore over the visible range. The composite provides extraordinary sensitisation from the Zn(F-BTZ)2 to Er(ftpip)3 over a broad-visible band, which is compatible with high power LEDs, whilst the erbium ions have a new record of IR emission lifetime of ~ 0.8 ms (quantum yield = ~ 7%). The integrated sensitisation is ~ 104 times that of the intrinsic excitation into erbium. This system has been integrated into an organic light emitting diodes (OLEDs) demonstrating that the energy transfer is dominated by triplet states of the Zn(F-BTZ)2. This is used for explaining the photoluminescence saturation and large pump-rate, with the composite being excited by a low power diode laser on the chromophore units. This composite-system was used to fabricate a slab waveguide, in which an relative gain of 3.4 dB/cm was achieved when excited by a diode laser with 3 mW. A microscopic-optic setup was designed to measure IR line strengths of erbium ions in crystals of complexes, which were included in theoretical calculation to obtain accurate quantum yield for IR emission of erbium ions. The inclusion of IR line strengths measured from crystals is found to be crucial for Judd-Ofelt parameterisation on organic erbium complexes. It was demonstrated that fluorination could increase the line strengths of hypersensitive transitions and IR transition for 1.5 μm band.
24

Development of composite cavity fibre lasers for fibre laser hydrophone systems

Leung, Ian Kin-Hay, Electrical Engineering & Telecommunications, Faculty of Engineering, UNSW January 2008 (has links)
In this thesis, my main focus was to establish a novel composite-cavity fibre laser (CCFL) and to apply it in sensing, particularly in the hydrophone application. The CCFL that I have proposed is formed by writing three wavelength matched fibre Bragg gratings directly into a continuous length of doped fibre. I have also examined the relative advantages and disadvantages of interferometric and intensity-based hydrophone systems, and have established a hydrophone system that can be switched between the two modes of operation, by making use of digital signal processing. I have established a theoretical model to study the lasing and spectral characteristics of the CCFL. My analysis showed that whilst the CCFL have significantly different phase and threshold conditions from the common semiconductor diode lasers with external cavity, the CCFL also have mode-limiting properties that are often sought after. Through simulations, I was able to identify that a non-uniform straining scheme, that is, when one of the sub-cavities of the CCFL is restrained from strain, can improve the sensitivity with respect to existing single cavity fibre lasers, in both the frequency and intensity domains. My simulations also showed that the sensitivity of such a straining scheme can be optimised by tuning the reflectivity of the gratings, sub-cavity lengths, doping concentration and pump power. I have fabricated multiple CCFLs using the in-house grating writing facilities, and have experimentally assessed their power and spectral related lasing characteristics. Whilst having a significantly longer total cavity length compared to typical fibre lasers, the CCFLs demonstrated stable single longitudinal mode operation and narrow linewidth in the order for a few tens of kHz. Asymmetric output power and frequency as a result of unequal sub-cavity lengths were also examined. Finally, I conducted sensing experiments by applying the CCFLs in strain monitoring and intensity-based hydrophone. My results showed that the non-uniform straining scheme had significantly improved the intensity response of the CCFL, and that the acoustic pressure and frequency can be determined by directly sampling and applying Fourier transform to the output intensity of the fibre laser.
25

Point-based Ionizing Radiation Dosimetry Using Radiochromic Materials and a Fibreoptic Readout System

Rink, Alexandra 01 August 2008 (has links)
Real-time feedback of absorbed dose at a point within a patient can help with radiological quality assurance and innovation. Two radiochromic materials from GafChromic MD-55 and EBT films have been investigated for applicability in real-time in vivo dosimetry of ionizing radiation. Both films were able to produce a real-time measurement of optical density from a small volume, allowing positioning onto a tip of an optical fibre in the future. The increase in optical density was linear with absorbed dose for MD-55, and non-linear for EBT. The non-linearity of EBT is associated with its increased sensitivity to ionizing radiation compared to MD-55, thus reaching optical saturation at a much lower dose. The radiochromic material in EBT film was also shown to polymerize and stabilize faster, decreasing dose rate dependence in real-time measurements in comparison to MD-55. The response of the two media was tested over 75 kVp – 18 MV range of x-ray beams. The optical density measured for EBT was constant within 3% throughout the entire range, while MD-55 exhibited a nearly 40% decrease at low energies. Both materials were also shown to be temperature sensitive, with the change in optical density generally decreasing when the temperature increased from ~22°C to ~37°C. This was accompanied by a shift in the peak absorbance wavelength. It was illustrated that some of this decrease can be corrected for by tracking the peak position and then multiplying the optical density by a correction factor based on the predicted temperature. Overall, the radiochromic material in GafChromic EBT film was found to be a better candidate for in vivo real-time dosimetry than the material in GafChromic MD-55. A novel mathematical model was proposed linking absorbance to physical parameters and processes of the radiochromic materials. The absorbance at every wavelength in the spectrum was represented as a sum of absorbances from multiple absorbers, where absorbance is characterized by its absorption coefficient, initiation constant, and polymerization constant. Preliminary fits of this model to experimental data assuming two absorbers suggested that there is a trade-off between EBT’s greater sensitivity and its dose linearity characteristics. This was confirmed by experimental results.
26

Point-based Ionizing Radiation Dosimetry Using Radiochromic Materials and a Fibreoptic Readout System

Rink, Alexandra 01 August 2008 (has links)
Real-time feedback of absorbed dose at a point within a patient can help with radiological quality assurance and innovation. Two radiochromic materials from GafChromic MD-55 and EBT films have been investigated for applicability in real-time in vivo dosimetry of ionizing radiation. Both films were able to produce a real-time measurement of optical density from a small volume, allowing positioning onto a tip of an optical fibre in the future. The increase in optical density was linear with absorbed dose for MD-55, and non-linear for EBT. The non-linearity of EBT is associated with its increased sensitivity to ionizing radiation compared to MD-55, thus reaching optical saturation at a much lower dose. The radiochromic material in EBT film was also shown to polymerize and stabilize faster, decreasing dose rate dependence in real-time measurements in comparison to MD-55. The response of the two media was tested over 75 kVp – 18 MV range of x-ray beams. The optical density measured for EBT was constant within 3% throughout the entire range, while MD-55 exhibited a nearly 40% decrease at low energies. Both materials were also shown to be temperature sensitive, with the change in optical density generally decreasing when the temperature increased from ~22°C to ~37°C. This was accompanied by a shift in the peak absorbance wavelength. It was illustrated that some of this decrease can be corrected for by tracking the peak position and then multiplying the optical density by a correction factor based on the predicted temperature. Overall, the radiochromic material in GafChromic EBT film was found to be a better candidate for in vivo real-time dosimetry than the material in GafChromic MD-55. A novel mathematical model was proposed linking absorbance to physical parameters and processes of the radiochromic materials. The absorbance at every wavelength in the spectrum was represented as a sum of absorbances from multiple absorbers, where absorbance is characterized by its absorption coefficient, initiation constant, and polymerization constant. Preliminary fits of this model to experimental data assuming two absorbers suggested that there is a trade-off between EBT’s greater sensitivity and its dose linearity characteristics. This was confirmed by experimental results.
27

Development of composite cavity fibre lasers for fibre laser hydrophone systems

Leung, Ian Kin-Hay, Electrical Engineering & Telecommunications, Faculty of Engineering, UNSW January 2008 (has links)
In this thesis, my main focus was to establish a novel composite-cavity fibre laser (CCFL) and to apply it in sensing, particularly in the hydrophone application. The CCFL that I have proposed is formed by writing three wavelength matched fibre Bragg gratings directly into a continuous length of doped fibre. I have also examined the relative advantages and disadvantages of interferometric and intensity-based hydrophone systems, and have established a hydrophone system that can be switched between the two modes of operation, by making use of digital signal processing. I have established a theoretical model to study the lasing and spectral characteristics of the CCFL. My analysis showed that whilst the CCFL have significantly different phase and threshold conditions from the common semiconductor diode lasers with external cavity, the CCFL also have mode-limiting properties that are often sought after. Through simulations, I was able to identify that a non-uniform straining scheme, that is, when one of the sub-cavities of the CCFL is restrained from strain, can improve the sensitivity with respect to existing single cavity fibre lasers, in both the frequency and intensity domains. My simulations also showed that the sensitivity of such a straining scheme can be optimised by tuning the reflectivity of the gratings, sub-cavity lengths, doping concentration and pump power. I have fabricated multiple CCFLs using the in-house grating writing facilities, and have experimentally assessed their power and spectral related lasing characteristics. Whilst having a significantly longer total cavity length compared to typical fibre lasers, the CCFLs demonstrated stable single longitudinal mode operation and narrow linewidth in the order for a few tens of kHz. Asymmetric output power and frequency as a result of unequal sub-cavity lengths were also examined. Finally, I conducted sensing experiments by applying the CCFLs in strain monitoring and intensity-based hydrophone. My results showed that the non-uniform straining scheme had significantly improved the intensity response of the CCFL, and that the acoustic pressure and frequency can be determined by directly sampling and applying Fourier transform to the output intensity of the fibre laser.
28

Optical Fibre-Based Hydrophone and Critical Ignition in Detonation Cells

Cheevers, Kevin 06 October 2021 (has links)
This thesis is composed of two distinct parts. The first part of this work addresses the problem of critical ignition behind a decaying shock wave in the context of cellular detonations. Low-pressure (4.1 kPa) shock tube experiments were performed in a thin rectangular channel using the highly-unstable mixture of CH4 + 2O2 and the weakly-unstable mixture of 2H2 + O2 + 7Ar, with Schlieren visualization of the flow field. The dynamics of the lead shock in a detonation cell was reconstructed from measurements of the lead shock position and curvature. The post-shock state and the expansion rate along the path of a Lagrangian particle crossing the lead shock at any given point in the cell cycle were evaluated with the shock jump and shock change equations. The chemical evolution behind the shock was then integrated using a detailed chemistry model. Quenching of the post-shock reaction zone was found within the first half of the detonation cell for both mixtures, with quenching occurring earlier in the highly unstable mixture. Simplified models derived from 1-step and 2-step chemistry models very accurately predict the quenching of the post-shock reactions and the evolution of the ignition delay through the cell. The second part describes the assembly and characterization of a fibre-optic probe hydrophone (FOPH) for the measurement of shock waves associated with blast-induced neuro-trauma. Compared to traditional polyvinylidene difluoride (PVDF) hydrophones, the assembled FOPH has a higher bandwidth and smaller active diameter, which are comparable to the characteristic time and thickness of shock waves associated with blast-induced neuro-trauma. However, the sensitivity of FOPHs are substantially lower than traditional hydrophones. We assemble a FOPH and provide detailed calculations and measurements of its sensitivity (0.66 mV/MPa) , noise floor, and spatial resolution. The 150 MHz bandwidth, limited by the photodetector, is sufficient for resolving shock waves with over-pressures of up to 174 kPa with 3 measurement points. Experimental measurements of the system noise gives a floor of 260 Pa/√Hz . A detailed noise analysis finds that the system is limited by photodetector noise (215 Pa/√Hz), which is 4x the fundamental shot noise limit, closely followed by a laser noise of 150 Pa/√Hz. We conclude that the system noise floor is insufficient for resolved measurements of the post-shock pressure in the range associated with blast-induced neuro-trauma. From our noise analysis, we quantify the sensitivity enhancement required for resolving this regime, and we conclude that sensitivity-enhancing fibre-coatings could provide a sufficient increase in sensitivity.
29

Durability of Embedded Fibre Optic Sensors in Composites

Levin, Klas January 2001 (has links)
This thesis concerns various aspects of the durability offibre optic sensors embedded in composite. Since repair orreplacement of embedded sensors is not generally possible, thefunctional reliability of embedded sensors is one of the mostimportant prerequisites for successful use. The main researchobjective was to investigate the interaction between the sensorand the composite, and how this is affecting the mechanical andoptical sensor response. Fibre optic sensors embedded incomposite structures induce local stress concentrations whenthe composite is subjected to mechanical loads andenvironmental changes such as temperature and moisture. Acomplex transfer of stresses through the interfaces between theembedded sensor and the composite occurs and can result inlarge local stresses in the composite and a significant changein the response of the embedded sensor. These stressconcentrations make the interfaces susceptible todebonding. The sensor performance was studied experimentally andnumerically. Some basic results were generated for the EFPI andBragg grating sensors. The phase-strain response was determinedduring static and fatigue loading. The results showed that thesensors were more reliable in compression than in tensilestatic and fatigue loading. Generally, the sensor reliabilityduring loading was significantly improved for the Bragg gratingsensors over that of the EFPI sensor, as an effect of thesensor geometry. This was also demonstrated in theinvestigations on impacts. Impacts do not necessarily result indamage in the composite, but might cause debonding or otherfailure modes in the sensor area. Large, local stressconcentrations occur at several positions in the EFPI sensor,which pointed out that this sensor type was not suitable forembedded applications. The shift in focus from the sensor concept based on the EFPIsensor to that based on the Bragg grating sensor manifesteditself in several studies. The calculated deformation fieldaround an embedded optical fibre was verified in experimentsusing a high-resolution moiré interferometric technique.Furthermore, the improvement in the coating technology wasverified. A significant higher interfacial strength wasobtained with the silane-treated glass surface. The resultsindicated that at least a twofold improvement of the shearstrength was obtained. To simultaneously measure the in-plane strain components andthe temperature change, embedded Bragg grating sensors werearranged in a rosette configuration. The relationship betweenthe optical response from each sensor and the strains in thelaminate was numerically and analytically established. Damage lead to stress redistribution in the sensor region,which may influence the output from the embedded Bragg gratingsensor. The effect was numerically evaluated for interfacialdamage, and was compared to that of a sensor with undamagedinterface. The results showed that debonding might have asignificant influence, in particular for combined thermal andmechanical loading. <b>Keywords</b>: composites, fibre optic sensor, embedded, EFPIsensor, Bragg grating sensor, durability, fatigue, impact,strain measurement, interface, stress analysis
30

Modulation Properties of Vertical Cavity Light Emitters

Stevens, Renaud January 2001 (has links)
It is estimated that, between the year 2000 and 2003, thenumber of online Internet users will grow from 250 millions to500 millions. This growth results in rapidly increasing demandfor fibre-optic communication bandwidth, occurring at alllevels: from access and local area networks (LANs) tometro-area networks (MANs). A now established solution for manyapplications such as interconnects and Gigabit Ethernet is thevertical cavity surface emitting laser (VCSEL). The advantagesof VCSELs are numerous: low fabrication and coupling costs,large modulation bandwidth, array integration and tunability.VCSEL-based modules, with speed up to 2.5 Gbit/s are nowcommercially available for multimode fibre (MMF) basedapplications. However, devices operating at long wavelength andhigher transmission rates (10Gbit/s and more) will be needed inthe near future. The purpose of the work presented in this thesis was toobtain an understanding of the high-speed properties of VCSELs,in order to extend the modulation frequency at which they canbe used in fibre optical communication systems. An approach forsystematic high-speed characterisation of VCSELs is presentedand both its potential benefits and problems are discussed. Itis shown that the VCSEL dynamics, under certain conditions, canbe well described by a small number of parameters that can beextracted from small signal measurements and used forfurtheroptimisation. The calibrated small-signal modulation responsesof VCSELs have been measured and fitted to an analyticaltransfer function allowing the estimation of the resonancefrequency, damping factor and parasitic cut-off at differentbias points. This data can be used to determine the relativeimportance of different bandwidth limiting effects due todamping, thermal heating and parasitics. Small signal analysis and transmission experiments wereperformed with a large sample of VCSELs covering the variousranges of applications. Visible VCSELs and resonant cavitylight emitting diodes (RCLEDs) for very short reach plasticoptical fibre (POF) applications, 850nm datacom VCSELs forshort distance multimode fibre networks, and long wavelengthVCSELs for long haul single mode fibre transmission. <b>Keywords:</b>Semiconductor lasers, VCSEL, high-speedmodulation, fibre optic networks, datacom, RCLED, plasticoptical fibre

Page generated in 0.0407 seconds