Thermal Effects on Monitoring and Performance of Reinforced Concrete StructuresDeRosa, DANIELLE 31 October 2012 (has links)
Much of North America’s reinforced concrete infrastructure is reaching the end of its service life and careful inspection and assessment is required to ensure the appropriate capacity is maintained in these structures. The research conducted herein seeks to further the development of two new sensor technologies: fibre optic strain sensors and digital image correlation, which have the potential to provide comprehensive performance data for structures to a level of accuracy previously not possible. The research involves determining the accuracy of these sensor systems to monitor both strain and crack widths in reinforced concrete compared to conventional techniques, such as electrical resistance strain gauges. Preliminary work was also undertaken on correcting the sensor results for temperature. It was determined that temperature variations in the range of +21 °C to 20 °C, result in significant strain errors for both sensor systems. Once the results obtained from the sensors systems are corrected for temperature, crack widths are monitored in four small-scale reinforced concrete tension specimens, and strain and crack width behaviour is monitored in four full-scale beams under four point bending. One of the major problems faced when using the digital image correlation technique is out of plane movement which results in significant error. Techniques to lower this error are addressed. In addition, obtaining a more robust understanding of the effects of temperature on crack widths, stiffness, strength and short term creep behaviour of reinforced concrete elements is explored to improve structural monitoring and numerical models used for analysis. Four full-scale beams, two at room temperature and two at 20 °C, were loaded to failure under four point bending. A comparison of the room temperature and low temperature test results show that the cracks tend to close up at lower temperatures in members that are free to expand and contract. This behaviour results in a potential increase in shear capacity for beams at lower temperatures. The low temperature beams also saw a minor increase in strength, but saw no noticeable increase in stiffness. Lastly, short term creep behaviour was reduced in the low temperature beams once the formation of ice occurred. / Thesis (Master, Civil Engineering) -- Queen's University, 2012-10-31 11:08:32.631
|
2 |
BEHAVIOUR OF DETERIORATED PIPES REHABILITATED WITH GROUTED SLIPLINERSSimpson, Bryan 29 November 2013 (has links)
The goals of this research are to develop and validate the use of distributed fibre optic sensors for use in strain monitoring of buried culverts, and to use full-scale experiments to evaluate the performance of both deteriorated steel and reinforced concrete culverts rehabilitated with grouted slipliners subjected to surface loading. Bench scale experiments were conducted to evaluate the use of fibre optic sensors against conventional strain sensors. Then, fibre optic sensors were attached to a full-scale culvert that was tested in a buried state as a proof of concept. Finally, fibre optic sensors were used in two large scale buried pipe tests to explore the performance of rehabilitated flexible and rigid culverts. A deteriorated steel culvert was tested in a buried state under surface loading, then rehabilitated with a grouted high density polyethylene (HDPE) slipliner while still in a buried state and tested under surface loading at 0.9 m and 0.6 m burial depths. The rehabilitated steel pipe was tested under service loading, and up to 1250 kN of applied load. The results suggested that the grouted annulus stiffened the overall structure, and increased the capacity of the system to over 3 times the fully factored design load. A deteriorated reinforced concrete culvert was tested and rehabilitated in a similar fashion. The grout in the annulus penetrated the cracks at the crown, invert and joint of the concrete pipeline. The lined concrete pipe was tested to 1200 kN under single axle loading, and to 800 kN under single wheel loading. The results suggested that while the concrete pipe was stiffened by the grout, it remained the primary contributor to structural capacity, with the liner contributing little to the capacity. Repair reduced the diameter change by an average of 90%, with the capacity reaching approximately 3.3 and 4.2 times the design loads for single axle and single wheel pair loading, respectively. The maximum response was under single axle loading over the barrels of the concrete pipe. In no instance did the structures reach an ultimate limit state, and the tests were stopped after bearing failure of the soil occurred. / Thesis (Master, Civil Engineering) -- Queen's University, 2013-11-28 17:24:50.815
|
Page generated in 0.0793 seconds