• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 74
  • 1
  • Tagged with
  • 78
  • 78
  • 39
  • 22
  • 19
  • 19
  • 17
  • 15
  • 15
  • 15
  • 12
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistemas simplificados de tratamento de águas cinzas :filtros lentos de areia e de resíduo de ardósia com adsorção em carvão ativado /

Zipf, Mariah Siebert, 1986-, Pinheiro, Ivone Gohr, 1960-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2015 (has links) (PDF)
Orientador: Ivone Gohr Pinheiro. / Dissertação (Mestrado em Engenharia Ambiental) - Programa de Pós-Graduação em Engenharia Ambiental, Centro de Ciências Tecnológicas.
2

Aplicação de principios de qualidade total na melhoria do controle do processo de filtração industrial de suco de laranja

Lima, Carla Pereira 20 May 1996 (has links)
Orientador: Jose Antonio D. Rios / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-21T08:38:47Z (GMT). No. of bitstreams: 1 Lima_CarlaPereira_M.pdf: 2344518 bytes, checksum: a044949b6f247daea3048236140a6114 (MD5) Previous issue date: 1996 / Resumo: Apresentamos um método de medida de eficiência de filtração de suco de laranja para "finisher", baseado na diferença de temperatura entre a polpa e o suco na entrada e comparamos com o teste rápido de fibra ou "quick fiber". O acréscimo da temperatura é causado, porque a filtração é realizada por prensagem. Este estudo foi desenvolvido numa linha de produção isolada, com 24 extratoras de suco de laranja, que alimenta dois "finishers" da marca FMC. O "quick fiber" mostrou-se impróprio, pois seu tempo de análise é de 1 O minutos, que é da mesma ordem de grandeza das perturbações na alimentação do "finisher". Existe a necessidade da colocação de um tanque de equilíbrio, antes da alimentação, a fim de reduzir os efeitos das perturbações. Aplicou-se o método de análise e solução de problemas, MASP, preconizado por DEMING, descrito por CAMPOS (1992), para padronizar o método de diferença de temperatura, foi observada consideravel redução das variações de "quick fiber" / Abstract: We presents a method for measuring the efficiency of orange juice filtration before the finisher, based on the difference between pulp and juice temperatures, comparing this method with the quick fiber test. The temperature increment is caused, because the filtration is happned by pressing process. The experiment was developed in an isolated production line, with 24 orange juice extractors sending juice to two FMC. The quick fiber method did not appear to be suitable since it took 10 minutes to analyze, and the finisher feed alteration occurs mainly at the moment of the orange batch changes. There is nicety to installation of the equilibrium tank, before the alimentation, to reduction of pertubation effects. The PDCA (plan, do, check and action) proclaimed by DEMING, and described by CAMPOS was applied to standard the difference between pulp and juice temperatures and considerable reduction in the quick fiber variations, was observed / Mestrado / Mestre em Engenharia de Alimentos
3

Avaliação de um filtro de manta sintetica não tecida para irrigação localizada

Cruz, Leila Beatriz Silva 27 August 1996 (has links)
Orientador: Jose E. Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-25T00:48:58Z (GMT). No. of bitstreams: 1 Cruz_LeilaBeatrizSilva_M.pdf: 1995121 bytes, checksum: 2d637b026752693cc86867f5abaf2d17 (MD5) Previous issue date: 1996 / Resumo: No presente trabalho apresenta-se a avaliação de um filtro de manta sintética não tecidadesenvolvido para a irrigação localizada. Este filtro consiste de um corpo cilíndrico de PVC com0.12 m de diâmetro e 0.40 m de comprimento, sendo instalado no seu interior outro Tubo de PVCcom furos de 8 mm, que durante a primeira etapa do trabalho foi substituído por tubo de inox com diâmetro dos furos de 25 mm, usado como suporte para a manta. Nos ensaios de filtro foram avaliados o seu comportamento hidráulico e carreira de filtrage~ bem como sua eficiência de remoção de sólidos em suspensão. Para efeito de comparação foram ensaiadas sob as mesmas condições, um filtro de Tela e outro de filtro de Disco, ambos de mesh 120 marca AMIAD. A primeira etapa do trabalho visou o desenvolvimento de uma metodologia apropriada para ensaios de filtros em laboratório. Para testar os filtros houve a necessidade de conhecer e controlar a qualidade da água a ser utilizada, e para alcançar este objetivo instalou-se no sistema um bomba injetora tipo Venturi que injetou mistura de água com sólidos suspensos na rede, podendo-se então analisar o afluente e efluente dos filtros. Durante os primeiros ensaios, verificou-se a possibilidade de melhorar a estrutura do filtro de manta. O tubo interno de PVC foi substituído por Inox com diâmetro de furos maior. E a saída de água do filtro que era reta foi substituída por outra de saída cônica, obtendo-se com estas alterações uma grande redução da perda de carga em função da vazão. Os resultados obtidos com os testes de filtragem mostraram que o filtro de manta apresentou duração da carreira de filtração da ordem de 14 minutos, sendo que os filtros de tela e disco apresentaram duração da carreira de filtração em tomo de 3 e 4 minutos, respectivamente. Com relação à remoção de sólidos em suspensão, o filtro de manta apresentou um valor médio de 25%, contra 12% do filtro de disco e 5 % do filtro de tela, para vazão de 6 m3/h.Para a vazão de 9 m3/h,os valores médios percentuais da remoção de sólidos suspenso foram 15% para o filtro de manta contra 10% do filtro tela e disco. O filtro de manta apresentou uma taxa de remo-çãode 18% para vazão de 12 m3/h,nãosendo possível realizar testes com os filtros de tela e disco nestas condições. Com base nesses dados, pode-se afirmar que o filtro de manta mostrou-se mais eficiente do que os de tela e disco. Também ficou evidente _quea manta sintética não tecida é adequada para ser empregada como meio filtrante em filtros para a irrigação localizada / Abstract: A filter of non woven synthetic fabrics developed for localized irrigation wasevaluated. This filter consists of a cylindricalpipe made of PVC with 0.12 m of diameter and 0.40 oflength and in its interior another perforated pipe ofPVC was installed to be used as a holder to the non woven synthetic fabrics. The trials were perfoI1J1edto evaluate the filter regarding its hydraulic behavior and filtration time, as well as its efÍiciencyof removing the solids of water. A. screen filter and disc filter (both of mesh 120 - AMIAD) were tested under the same conditions for comparison purpose. The first work stage aimed at the development of an appropriated methodology to filter trials and other equipments in the laboratory. To test the filter it was necessary to control and find out the quality of water to be used and a Venturi inject pump was installed to inject the mixture of water and solids in the system, with this it was possible to analyze the filter amuent and emuent. During the first trials, it was observed the possibility to improve the structure of the non woven synthetic fabrics filter. The intem pipe of PVC was substituted for inox with a diameter of larger holes. Also the original straight flush of water was substituted for conic flush achieving in this way a great reduction oflost pressure. The results obtained with the trials of filtration showed that the non woven synthetic fabrics filter displayed 14 minutes of duration of filtration time, and the screen and disc filters displayed about 3 and 4 minutes respectively. With regard to removal of solids, the non woven synthetic fabrics filter displayed an average value of 25%, against 12% of disc filter and 5% of screen filter for a rate flow of 6 m3Ih. Based on these data, it is possible to say that the non woven synthetic fabrics filter is more efficient than the screen and disc filters. It was also observed that non woven synthetic fabrics is appropriated as a means for filtration in localized irrigation / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
4

Obtenção e caracterização de filtros de profundidade de crisotilas brasileiras

Comerlato, Maria Helena 14 July 2018 (has links)
Orientador : Ines Joekes / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-14T01:02:55Z (GMT). No. of bitstreams: 1 Comerlato_MariaHelena_M.pdf: 3632202 bytes, checksum: 08a0ba24b3591de52e75b2853c6a50e7 (MD5) Previous issue date: 1989 / Mestrado
5

Analise de perda de carga em filtros de tela e disco de sistemas de irrigação localizada utilizando um sistema de aquisição de dados

Ramos, Jean Paulo Silva 16 October 1992 (has links)
Orientador : Roberto Testezlaf / Dissertação (mestrado)- Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-18T08:08:16Z (GMT). No. of bitstreams: 1 Ramos_JeanPauloSilva_M.pdf: 2932524 bytes, checksum: b9eaad03b6adc6626cca35d351a4d919 (MD5) Previous issue date: 1992 / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
6

Avaliação dos efeitos sobre os estimadores eletromiográficos de diversos métodos de filtragem da interferência da rede elétrica / Evaluation of the effects of various filtering methods on the electromyographic estimators

Pedroso, Luís Júlio de Gusmão Rocha 04 March 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2013. / Submitted by Elna Araújo (elna@bce.unb.br) on 2013-11-21T22:35:29Z No. of bitstreams: 1 2013_LuisJulioDeGusmaoPedroso.pdf: 4833098 bytes, checksum: 3fbfcd5686f9b880b58ece3cddb2383a (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-11-25T12:38:46Z (GMT) No. of bitstreams: 1 2013_LuisJulioDeGusmaoPedroso.pdf: 4833098 bytes, checksum: 3fbfcd5686f9b880b58ece3cddb2383a (MD5) / Made available in DSpace on 2013-11-25T12:38:46Z (GMT). No. of bitstreams: 1 2013_LuisJulioDeGusmaoPedroso.pdf: 4833098 bytes, checksum: 3fbfcd5686f9b880b58ece3cddb2383a (MD5) / Os sinais eletromiográficos (EMG) estão cada vez mais a serem utilizados para diagnósticos clínicos, controle de próteses de membros superiores ou inferiores e auxilio e acompanhamento do treinamento de atletas profissionais. O sucesso do uso da eletromiografia de superfície (EMGs) nessas aplicações é fortemente influenciado pela qualidade das informações obtidas desses sinais que por sua vez sofrem influências do meio, majoritariamente, influencias da rede elétrica de 60 Hz e seus harmônicos. Desta forma, o objetivo deste trabalho é avaliar os efeitos de diversos métodos de filtragem da interferência de 60 Hz e harmônicas provenientes da rede elétrica, sobre os estimadores eletromiográficos calculados com base em sinais eletromiográficos de superfície. Para isso, um sinal eletromiográfico sintético foi contaminado por diferentes sinais de interferência de 60 Hz, que foram em seguida, filtrados por filtros digitais do tipo FIR, IIR e adaptativos. Foram então calculados, para os sinais originais e para todos os sinais filtrados, os seguintes estimadores: valor quadrático médio (RMS), valor retificado médio (AVR), frequência média (MNF), frequência mediana (MDF) e velocidade de condução (CV). Para os resultados dos estimadores foi calculada a reta de regressão e feita a analise comparativa da influência dos filtros sobre o resultado dos estimadores através da comparação do coeficiente angular dessas retas em relação ao coeficiente angular das retas de controle, sinal sem ruído e com ruído, mas sem filtragem. Os valores obtidos demonstraram que não existe um filtro que possa ser aplicado com iguais resultados para todos os estimadores. Nos sinais com ruído jitter os estimadores apresentam inconsistência nos resultados, destacando a interferência do ruído jitter sobre os filtros e sobre os estimadores como consequência da relação da largura de banda do jitter e do corte notch dos filtros. Apesar das limitações do estudo, os resultados apresentam potencial para auxiliar pesquisadores na tomada de decisão do uso ou não de filtros em sinais EMGs e, caso positivo, quais apresentam melhores resultados. _______________________________________________________________________________ ABSTRACT / The surface electromyographic signals (EMGs) are being used for clinical diagnosis, control of prosthetic arms or legs and assisting and monitoring the training of professional athletes. The successful use of surface electromyography (EMGs) in these kind of applications is strongly influenced by the quality of the information obtained from these signals that, in turn, suffer from environmental influences, mainly influences from the electrical grid of 60 Hz and its harmonics. Thus, the objective of this study is to evaluate the effects of various methods of filtering interference of 60 Hz and harmonics from the electrical grid, on electromyographic estimators calculated based on surface electromyographic signals. For this, a synthetic electromyographic signal has been contaminated by different 60 Hz interference signals, which were filtered by FIR type digital filters, IIR and adaptive. So, there were calculated for the original signals and for all filtered signals, the following estimators: root mean square (RMS), average rectified value (AVR), mean frequency (MNF), median frequency (MDF) and conduction velocity (CV). For the results of the estimators, we calculated the regression line and a comparative analysis was made of the influence the filters on the results of estimators by comparing the angular coefficient of these lines in relation to the angular coefficients of the lines of control signal, without noise and with noise, but without filtering. The values obtained demonstrate that there is no filter that can be applied with similar results for all estimators. In signals with noise jitter estimators have had inconsistent results, especially the interference noise jitter on the filters and on the estimators as a result of the relationship of jitter bandwidth jitter and notch cut filters. Despite the limitations of the study, the results have potential to assist researchers in making the decision to use or not of filters in EMGs signals and, if so, which ones show better results.
7

Utilização de mantas não tecidas como elemento filtrante em sistemas de irrigação localizada

Scatolini, Marcos Eduardo 28 July 2018 (has links)
Orientador : Jose Euclides Stipp Paterniani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-28T11:24:15Z (GMT). No. of bitstreams: 1 Scatolini_MarcosEduardo_D.pdf: 2223198 bytes, checksum: e39154c22cf1dcb99ac9bcf78ab91422 (MD5) Previous issue date: 2001 / Doutorado
8

Eficiencia da pre-filtração e filtração lenta no controle das caracteristicas quimicas, fisicas e biologicas da agua para piscicultura

Conceição, Celso Henrique Zuppi da 02 August 2018 (has links)
Orientador : Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-08-02T10:15:25Z (GMT). No. of bitstreams: 1 Conceicao_CelsoHenriqueZuppida_M.pdf: 2954298 bytes, checksum: e1174ed489da7e6ea221ba169c7777af (MD5) Previous issue date: 2002 / Mestrado
9

Desempenho de diferentes tipos de mantas sinteticas não tecidas na filtração da agua para irrigação localizada

Lima, Miller Marani 25 July 2018 (has links)
Orientador: Jose Euclides Stipp Paterniani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agricola / Made available in DSpace on 2018-07-25T11:56:25Z (GMT). No. of bitstreams: 1 Lima_MillerMarani_M.pdf: 1347770 bytes, checksum: 84dd71fa17f5329061804415f00d1db1 (MD5) Previous issue date: 1999 / Mestrado
10

Estudos de limpeza de filtro lento por raspagem e retrolavagem

Pizzolatti, Bruno Segalla 16 July 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2010 / Made available in DSpace on 2013-07-16T04:01:44Z (GMT). No. of bitstreams: 1 278502.pdf: 1087364 bytes, checksum: e3ef6de1b1720897b5c8148cf6c100e5 (MD5) / Este trabalho pretendeu desenvolver e aprimorar a tecnologia da filtração lenta retrolavável no tratamento de água de lago com vistas a suprir as necessidades de consumo humano. Com a adoção da retrolavagem em filtro lento, pode-se ampliar as opções de sistemas de tratamento que apresentam operação facilitada. O objetivo da pesquisa foi avaliar uma alternativa de fornecimento de água adequada para o consumo humano, especialmente em propriedades isoladas, bem como avaliar a eficiência dos filtros submetidos a retrolavagem. O manancial de estudo está localizado no Sul da Ilha de Santa Catarina. Foram construídos três sistemas pilotos em paralelo, sendo eles; filtro lento com limpeza convencional (sistema 1); filtro lento retrolavável com água filtrada (sistema 2); filtro lento retrolavável com água bruta (sistema 3). Os três filtros são cobertos, de escoamento descendente, operaram com taxa de filtração de 4 m3/m2dia e carga hidráulica variável. A limpeza convencional foi realizada no sistema 1, enquanto que nos sistemas 2 e 3 a limpeza foi realizada através de retrolavagem com expansão média de 10%. Durante o trabalho foi realizado: a caracterização da água bruta, dimensionamento dos sistemas piloto, desenvolvimento de um filtro lento retrolavável com água bruta, e avaliação dos diferentes tipos de limpeza nos filtros estudados. Durante o tempo de monitoramento dos sistemas foram realizadas nove carreiras de filtração válidas, com duração média de 13 dias para os sistemas. Estatisticamente o sistema 1 obteve melhor desempenho em termos de remoção de parâmetros de qualidade, produzindo efluente final com turbidez e cor aparente médias de 0,93±0,36 uT e 15±8 uH, respectivamente, alcançando na remoção destes parâmetros percentagens de 81,67±2,83 (turbidez) e 76,56±4,07 (cor aparente). Contudo do ponto de vista operacional o sistema 2, com eficiência de remoção (em %) de 79,33±3,09 (turbidez) e 73,11±5,64 (cor aparente), se demonstrou mais atrativo, tendo em vista a forma de limpeza. A interpretação dos resultados obtidos, em termos de perda de carga no meio filtrante, sugerem mudanças na concepção de desenho dos sistemas 2 e 3. Em função dos resultados obtidos, pode-se considerar que o trabalho contribui para facilitar a operação de filtros lentos o que pode resultar no aumento do uso desta tecnologia principalmente em comunidades isoladas, desprovidas de tratamento e abastecimento público de água.

Page generated in 0.0778 seconds