• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 73
  • 13
  • 7
  • 4
  • 1
  • Tagged with
  • 134
  • 134
  • 134
  • 28
  • 24
  • 15
  • 13
  • 13
  • 12
  • 12
  • 11
  • 11
  • 11
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Load transfer across cracks and joints in concrete slabs on grade

Arnold, Stuart John January 2004 (has links)
This research has investigated the behaviour of joints and cracks under single and multiple cycles of load. This provides an increased understanding of concrete slab on grade performance, enabling more effective design and monitoring procedures. Examination of the geometry of cracks and joints within concrete slabs on grade has demonstrated that the commonly assumed parallel formation is erroneous. Measurements using embedded strain gauges, coring and surface profile levelling have uncovered that a high percentage of joints will contain larger crack widths at the surface than at the base, caused by differential shrinkage. The opening itself is relatively linear; however, the top 50mm of the slab is prone to a higher gradient of movement due to the increased drying effect towards the surface. A series of deflection tests using a Falling Weight Deflectometer and Prima dynamic plate enabled slab response under load to be evaluated. Four sites were examined in total and correlations found between: load transfer, load step, edge cantilever and crack geometry. This produced valuable information regarding the influence of load transfer and crack width on the overall slab behaviour. Foundation voiding and crack face free slip was also shown to influence deflection magnitude. A small-scale test facility was developed for the assessment of deterioration in various 'V' shaped and parallel crack widths under high cycle loading. The data demonstrated that joint/crack failure contains four distinct phases of deterioration, each of which is controlled by a different mechanism. 'V' shaped cracks produced a much greater load transfer than that of a parallel crack with the incorporation of A142 mesh and steel fibres reducing differential displacement. Load magnitude and aggregate size were also shown to have significant effects. The value of reinforcement was found to assist with serviceability requirements, keeping displacement within acceptable levels and preventing the onset of serious degradation A finite element model was developed to enable the load transfer mechanism results from the laboratory test to be used in the assessment of full slab response. Simulations of field testing produced a series of lower bounds in respect to deflections and the associated response calculations. Theoretical behaviour of a typical slab was assessed with subbase support, joint stiffness, slab thickness and the incorporation of a subbase, found to be highly influential in reducing slab deflections. The three main sections of work comprising site data collection, laboratory testing and Finite Element modelling have been used together to provide a much greater understanding of the influence of cracks and joints. This has included the deterioration of cracks over time and an examination of how this and other site-based factors affect overall slab behaviour.
42

Contact deformation of carbon coatings: mechanisms and coating design.

Singh, Rajnish Kumar, Materials Science & Engineering, Faculty of Science, UNSW January 2008 (has links)
This thesis presents the results of a study focussed on the elucidation of the mechanisms responsible for determining the structural integrity of carbon coatings on ductile substrates. Through elucidation of these mechanisms, two different coating systems are designed; a multilayered coating and a functionally graded coating. While concentrating upon carbon coatings, the findings of this study are applicable to a broad range of hard coatings on ductile substrates. The thesis concludes with a chapter outlining a brief study of the effects of gold coatings on silicon under contact load at moderate temperatures to complement the major part of the thesis. Carbon coatings with differing mechanical properties were deposited using plasma enhanced chemical vapour deposition (PECVD), filtered assisted deposition (FAD) and magnetron sputtering deposition methods. Combinations of these techniques plus variation of deposition parameters enabled composite multilayered and functionally-graded coatings to also be deposited. Substrates were ductile metals; stainless steel and aluminium. Characterisation of the coating mechanical properties was undertaken using nanoindentation and nano-scratch tests. The same techniques were used to induce fracture within the coatings to allow subsequent analysis of the fracture mechanism. These were ascertained with the assistance of cross-sectional imaging of indents prepared using a focussed ion beam (FIB) mill and transmission electron microscopy (TEM) using specimen preparation techniques also utilising the focussed ion beam mill. A two dimensional axisymmetric finite element model (FEM) was built of the coating systems using the commercial software package, ANSYS. Substrate elastic-plastic properties were ascertained by calibrating load-displacement curves on substrate materials with the finite element model results. Utilising the simulation of spherical indentation, the distribution of stresses and the locations for fracture initiation were ascertained using finite element models. This enabled determination of the influence such factors as substrate mechanical properties, residual stresses in the coatings and importantly the variation of elastic properties of the different coating materials. Based upon the studies of monolithic coatings, simulations were undertaken on multilayer and functionally-graded coatings to optimise design of these coating types. Based on the results of the modelling, multilayered and functionally graded coatings were then deposited and mechanical testing undertaken to confirm the models. Three major crack types were observed to occur as the result of the spherical nanoindentation on the coatings; ring, radial and lateral cracks. Ring cracks were found to initiate from the top surface of the film, usually at some distance from the edge of the spherical contact. Radial cracks usually initiated from the interface between the coating and the substrate directly under the symmetry axis of indentation and propagated outwards in a non symmetrical star-like fashion. Lateral cracks formed either between layers in the multilayer coatings or at the interface with substrate. Ring and radial cracks were found to form upon loading whereas lateral cracks formed upon both loading and unloading depending upon the crack driving mechanism. Pop-in events in the load displacement indentation curve were found to be indicative of the formation of ring cracks, while the formation of the other types of cracks was not signified by pop-ins but rather by variations in the slope of the curve. The substrate yield strength was found to influence the initiation of all crack systems while compressive stresses in the coating were seen to only influence the formation of ring and radial cracks. However, it was also noted that the initiation of one form of crack tended to then hinder the subsequent formation of others. In multilayer coatings, the lateral cracks were suppressed, as opposed to the monolayer coating system, but a ring crack was observed. This drawback in the multilayer system was successfully addressed by the design of a graded coating having the highest Young??s modulus at the middle of the film thickness. In this coating, due to the graded nature of the elastic modulus, the stresses at the deleterious locations (top surface and interface) were guided toward the middle of coating and hence increased the load bearing capabilities. The effect of substrate roughness upon the subsequent surface roughness of the coating and also upon the fracture process of the coating during indentation was also investigated. For the coatings deposited on rough substrates, the radial cracks were observed to form initially and this eventfully delayed the initiation of ring cracks. Also the number of radial cracks observed at the interface was found to be proportional to the distribution of the interfacial asperities. In summary, the study elucidated the fracture mechanisms of monolayer, multilayer and graded carbon coatings on ductile substrates under uniaxial and sliding contact loading. The effects of the yield strength, surface roughness of the substrate, along with the residual stress and elastic modulus of the coatings on the fracture of coatings were investigated. The study utilised finite element modelling to explain the experiments observations and to design coating systems.
43

Modelling Breast Tissue Mechanics Under Gravity Loading

Rajagopal, Vijayaraghavan January 2007 (has links)
This thesis presents research that was conducted to develop anatomically realistic finite element models of breast deformation under a variety of gravity loading conditions to assist clinicians in tracking suspicious tissues across multiple imaging modalities. Firstly, the accuracy of the modelling framework in predicting deformations of a homogeneous body was measured using custom designed silicon gel phantoms. The model predicted surface deformations with an average RMS error of 1.5 mm +/- 0.2 mm and tracked internal marker locations with an average RMS error of 1.4 mm +/- 0.7 mm. A novel method was then developed to determine the reference configuration of a body, when given its mechanical properties, boundary conditions and a deformed configuration. The theoretical validity of the technique was confirmed with an analytic solution. The accuracy of the method was also measured using silicon gel experiments, predicting the reference configuration surface with an average RMS error of 1.3 mm +/- 0.1 mm, and tracking internal marker locations with an average error of 1.5 mm +/- 0.8 mm. Silicon gel composites were then created to measure the accuracy of standard techniques to model heterogeneity. The models did not match the experimentally recorded deformations. This highlighted the need for further validation exercises on modelling heterogeneity before modelling them in the breast. A semi-automated algorithm was developed to fit finite element models to the skin and muscle surfaces of each individual, which were segmented from breast MR images. The code represented the skin with an average RMS error of 1.46 mm +/- 0.32 mm and the muscle with an average RMS error of 1.52 mm +/- 0.3 mm. The framework was then tested using images of the breast obtained under different gravity loading conditions and neutral buoyancy. A homogeneous model was first developed using the neutral buoyancy images as a representation of the reference configuration. The model did not accurately capture the regional deformations of the breast under gravity loading. However, the gross shape of the breast was reproduced, indicating that a biomechanical model of the breast could be useful to reliably track tissues across multiple images for cancer diagnosis. / This research was sponsored by the Top Achiever Doctoral Scholarship and the University of Auckland Doctoral Scholarship. Extra funding for travel was provided by the Graduate Research Fund and the John Logan Campbell Trust Fund.
44

Modelling Breast Tissue Mechanics Under Gravity Loading

Rajagopal, Vijayaraghavan January 2007 (has links)
This thesis presents research that was conducted to develop anatomically realistic finite element models of breast deformation under a variety of gravity loading conditions to assist clinicians in tracking suspicious tissues across multiple imaging modalities. Firstly, the accuracy of the modelling framework in predicting deformations of a homogeneous body was measured using custom designed silicon gel phantoms. The model predicted surface deformations with an average RMS error of 1.5 mm +/- 0.2 mm and tracked internal marker locations with an average RMS error of 1.4 mm +/- 0.7 mm. A novel method was then developed to determine the reference configuration of a body, when given its mechanical properties, boundary conditions and a deformed configuration. The theoretical validity of the technique was confirmed with an analytic solution. The accuracy of the method was also measured using silicon gel experiments, predicting the reference configuration surface with an average RMS error of 1.3 mm +/- 0.1 mm, and tracking internal marker locations with an average error of 1.5 mm +/- 0.8 mm. Silicon gel composites were then created to measure the accuracy of standard techniques to model heterogeneity. The models did not match the experimentally recorded deformations. This highlighted the need for further validation exercises on modelling heterogeneity before modelling them in the breast. A semi-automated algorithm was developed to fit finite element models to the skin and muscle surfaces of each individual, which were segmented from breast MR images. The code represented the skin with an average RMS error of 1.46 mm +/- 0.32 mm and the muscle with an average RMS error of 1.52 mm +/- 0.3 mm. The framework was then tested using images of the breast obtained under different gravity loading conditions and neutral buoyancy. A homogeneous model was first developed using the neutral buoyancy images as a representation of the reference configuration. The model did not accurately capture the regional deformations of the breast under gravity loading. However, the gross shape of the breast was reproduced, indicating that a biomechanical model of the breast could be useful to reliably track tissues across multiple images for cancer diagnosis. / This research was sponsored by the Top Achiever Doctoral Scholarship and the University of Auckland Doctoral Scholarship. Extra funding for travel was provided by the Graduate Research Fund and the John Logan Campbell Trust Fund.
45

Modelling Breast Tissue Mechanics Under Gravity Loading

Rajagopal, Vijayaraghavan January 2007 (has links)
This thesis presents research that was conducted to develop anatomically realistic finite element models of breast deformation under a variety of gravity loading conditions to assist clinicians in tracking suspicious tissues across multiple imaging modalities. Firstly, the accuracy of the modelling framework in predicting deformations of a homogeneous body was measured using custom designed silicon gel phantoms. The model predicted surface deformations with an average RMS error of 1.5 mm +/- 0.2 mm and tracked internal marker locations with an average RMS error of 1.4 mm +/- 0.7 mm. A novel method was then developed to determine the reference configuration of a body, when given its mechanical properties, boundary conditions and a deformed configuration. The theoretical validity of the technique was confirmed with an analytic solution. The accuracy of the method was also measured using silicon gel experiments, predicting the reference configuration surface with an average RMS error of 1.3 mm +/- 0.1 mm, and tracking internal marker locations with an average error of 1.5 mm +/- 0.8 mm. Silicon gel composites were then created to measure the accuracy of standard techniques to model heterogeneity. The models did not match the experimentally recorded deformations. This highlighted the need for further validation exercises on modelling heterogeneity before modelling them in the breast. A semi-automated algorithm was developed to fit finite element models to the skin and muscle surfaces of each individual, which were segmented from breast MR images. The code represented the skin with an average RMS error of 1.46 mm +/- 0.32 mm and the muscle with an average RMS error of 1.52 mm +/- 0.3 mm. The framework was then tested using images of the breast obtained under different gravity loading conditions and neutral buoyancy. A homogeneous model was first developed using the neutral buoyancy images as a representation of the reference configuration. The model did not accurately capture the regional deformations of the breast under gravity loading. However, the gross shape of the breast was reproduced, indicating that a biomechanical model of the breast could be useful to reliably track tissues across multiple images for cancer diagnosis. / This research was sponsored by the Top Achiever Doctoral Scholarship and the University of Auckland Doctoral Scholarship. Extra funding for travel was provided by the Graduate Research Fund and the John Logan Campbell Trust Fund.
46

Modelling Breast Tissue Mechanics Under Gravity Loading

Rajagopal, Vijayaraghavan January 2007 (has links)
This thesis presents research that was conducted to develop anatomically realistic finite element models of breast deformation under a variety of gravity loading conditions to assist clinicians in tracking suspicious tissues across multiple imaging modalities. Firstly, the accuracy of the modelling framework in predicting deformations of a homogeneous body was measured using custom designed silicon gel phantoms. The model predicted surface deformations with an average RMS error of 1.5 mm +/- 0.2 mm and tracked internal marker locations with an average RMS error of 1.4 mm +/- 0.7 mm. A novel method was then developed to determine the reference configuration of a body, when given its mechanical properties, boundary conditions and a deformed configuration. The theoretical validity of the technique was confirmed with an analytic solution. The accuracy of the method was also measured using silicon gel experiments, predicting the reference configuration surface with an average RMS error of 1.3 mm +/- 0.1 mm, and tracking internal marker locations with an average error of 1.5 mm +/- 0.8 mm. Silicon gel composites were then created to measure the accuracy of standard techniques to model heterogeneity. The models did not match the experimentally recorded deformations. This highlighted the need for further validation exercises on modelling heterogeneity before modelling them in the breast. A semi-automated algorithm was developed to fit finite element models to the skin and muscle surfaces of each individual, which were segmented from breast MR images. The code represented the skin with an average RMS error of 1.46 mm +/- 0.32 mm and the muscle with an average RMS error of 1.52 mm +/- 0.3 mm. The framework was then tested using images of the breast obtained under different gravity loading conditions and neutral buoyancy. A homogeneous model was first developed using the neutral buoyancy images as a representation of the reference configuration. The model did not accurately capture the regional deformations of the breast under gravity loading. However, the gross shape of the breast was reproduced, indicating that a biomechanical model of the breast could be useful to reliably track tissues across multiple images for cancer diagnosis. / This research was sponsored by the Top Achiever Doctoral Scholarship and the University of Auckland Doctoral Scholarship. Extra funding for travel was provided by the Graduate Research Fund and the John Logan Campbell Trust Fund.
47

Numerical Modelling of Galvanic Structural Joints Subjected to Combined Environmental and Mechanical Loading

January 2015 (has links)
abstract: Dissimilar metal joints such as aluminum-steel joints are extensively used in automobile, naval and aerospace applications and these are subjected to corrosive environmental and mechanical loading resulting in eventual failure of the structural joints. In the case of aluminum alloys under aggressive environment, the damage accumulation is predominantly due to corrosion and is accelerated in presence of other metals. During recent years several approaches have been employed to develop models to assess the metal removal rate in the case of galvanic corrosion. Some of these models are based on empirical methods such as regression analysis while others are based on quantification of the ongoing electrochemical processes. Here, a numerical model for solving the Nernst- Planck equation, which captures the electrochemical process, is implemented to predict the galvanic current distribution and, hence, the corrosion rate of a galvanic couple. An experimentally validated numerical model for an AE44 (Magnesium alloy) and mild steel galvanic couple, available in the literature, is extended to simulate the mechano- electrochemical process in order to study the effect of mechanical loading on the galvanic current density distribution and corrosion rate in AE44-mild steel galvanic couple through a multiphysics field coupling technique in COMSOL Multiphysics®. The model is capable of tracking moving boundariesy of the corroding constituent of the couple by employing Arbitrary Langrangian Eulerian (ALE) method.Results show that, when an anode is under a purely elastic deformation, there is no apparent effect of mechanical loading on the electrochemical galvanic process. However, when the applied tensile load is sufficient to cause a plastic deformation, the local galvanic corrosion activity at the vicinity of the interface is increased remarkably. The effect of other factors, such as electrode area ratios, electrical conductivity of the electrolyte and depth of the electrolyte, are studied. It is observed that the conductivity of the electrolyte significantly influences the surface profile of the anode, especially near the junction. Although variations in electrolyte depth for a given galvanic couple noticeably affect the overall corrosion, the change in the localized corrosion rate at the interface is minimal. Finally, we use the model to predict the current density distribution, rate of corrosion and depth profile of aluminum alloy 7075-stainless steel 316 galvanic joints, which are extensively used in maritime structures. / Dissertation/Thesis / Masters Thesis Mechanical Engineering 2015
48

Effect of numerical modelling assumptions on the simulated corneal response during Goldmann applanation tonometry

Botha, Natasha January 2014 (has links)
It is widely known that Central Corneal Thickness (CCT) and Radius of Curvature (RoC) in uence the estimated IntraOcular Pressure (IOP) obtained from Goldmann Applanation Tonometry (GAT). However, not much is known about the in uence of corneal material properties, especially in a clinical setting. Several numerical studies have been conducted in an attempt to quantify the in uence of corneal material properties on the IOP. These studies agree that corneal material properties do in uence the estimated IOP, which contradict the initial premise on which GAT was designed, namely that material properties do not in uence the obtained GAT readings. Also, there is no consensus among these studies with respect to corneal material properties, thus a wide range of proposed properties exist. A possible explanation for this range of available corneal properties is the numerical modi elling assumptions used, which seem to be quite different. Different sets of experimental in ation test data were used to calibrate the constitutive models and different limbal boundary conditions were applied to simulate the experimental setup as well as in vivo conditions during GAT simulations. Therefore the purpose of this study is to determine whether these modelling assumptions in uence the obtained IOP and ultimately the overall conclusions. A Finite Element (FE) model of the human cornea is developed, implementing a constitutive model to represent the complex corneal structure and two limbal boundary conditions. This model is then calibrated using two different sets of experimental in ation test data. During calibration of the fibre reinforced elastic constitutive model it is found that independent of the assumptions made regarding the material coe cients, that the numerical in ation data compare well with the experimental data for all cases. Using this model a GAT simulation is conducted to estimate the IOP and the in uence of the modelling assumptions, cornea geometry and material properties are then investigated. The results indicate that the modelling assumptions, cornea geometry and material properties do infuence the estimated IOP. However, when assuming the cornea ground substance stiffness to be constant, it is found that the in uence on IOP due to material properties is not as significant. A correction equation is also proposed to account for the corneal geometric properties by calibrating the numerical model for a numerically normal cornea. This is done by utilising the various data sets which are obtained during the calibration of the constitutive model with the experimental inflation test data. It is concluded that using only inflation data to calibrate the constitutive model is not sufficient to uniquely describe the corneal material. This is evident as different material data sets are obtained, even though the experimental inflation data is matched well for a variety of considered cases. Each of these material data sets, in conjunction with geometric properties, yield different estimates for IOP during GAT simulations. This study therefore recommends the use of additional experimental data, such as strip extensometry, along with inflation test data to adequately calibrate a numerical model. It should also be noted that when modelling GAT care should be taken when considering the choice of limbal boundary condition, experimental data for calibration and assumptions made with regards to material coe cients, as these choices could potentially influence the outcomes and conclusions of a study. / Dissertation (MEng)--University of Pretoria, 2014. / gm2014 / Mechanical and Aeronautical Engineering / unrestricted
49

Hot tearing and constitutive behaviour of semi-solid aluminum alloys

Phillion, André 05 1900 (has links)
The occurrence of hot tearing during solidification is one of the major factors influencing both the quality and productivity of aluminum castings. In order to reduce the formation of hot tears, quantitative information regarding both hot tearing formation and semi-solid deformation is essential. In this study, the mechanisms of hot tearing and semi-solid deformation have been investigated via two novel techniques: x-ray micro-tomography on material deformed in the semi-solid region, and development of a three phase microstructural model based on a geometry derived from a Voronoi diagram with rounded corners and porosity. Numerical techniques were utilized to quantify both the size evolution and orientation of internal damage relative to void growth. In order to conduct the above research, a new semi-solid tensile deformation methodology was devised which uses a two thermocouple control technique to enable accurate measurement of semi-solid tensile strength and ductility. The experimental work was conducted on the aluminum – magnesium alloy AA5182 in the as-cast and hot isostatic pressing (HIP) states. The x-ray micro-tomography technique was used to observe that semi-solid deformation is accommodated by internal damage via growth of as-cast porosity and the nucleation of new damage-based voids. As the volume fraction of damage increases, the growth of voids occurs in an orientation perpendicular to the loading direction, both through expansion within the grain boundary liquid and via coalescence between voids. The damage then localizes, causing failure. The finite element semi-solid microstructural model was used to explore the effects of fraction solid, fraction porosity, and grain size on semi-solid constitutive behaviour. The simulations revealed that increased grain size and fraction porosity lead to a reduction in flow stress for a given fraction solid. Furthermore, local strain accumulation was linked to hot tearing, since strain localizes in the liquid very early in the deformation process. Based on the model predictions, a new constitutive relationship was developed over the range 0.75 < fs < 0.95. Together, these two techniques have provided powerful new insight, such as the critical role played by as-cast porosity, on the phenomena of hot tearing and semi-solid deformation in aluminum alloys. / Applied Science, Faculty of / Materials Engineering, Department of / Graduate
50

Pulsed field magnetization of composite superconducting bulks for magnetic bearing applications

Patel, Anup January 2013 (has links)
Permanent magnets are essential components for many devices such as motors, which currently account for 45 % of global electricity consumption, generators and also superconducting magnetic bearings used for applications such as flywheel energy storage. But even the most powerful rare-earth magnets are limited to a remanent field of 1.4 T, whereas superconducting materials such as YBCO in their bulk form have the extraordinary ability to trap magnetic fields an order of magnitude higher, whilst being very compact. This gives them the potential to increase efficiency and allow significant volume and weight reductions for rotating machines despite the need for cooling. A new design of superconducting magnetic bearing has been developed which uses magnetized bulks as the field source, eliminating permanent magnets. Finite element modelling shows that the bulk – bulk design can achieve much higher force densities than existing permanent magnet – bulk designs, giving it potential to be used as a compact magnetic bearing. A system was created to magnetize bulks using a pulsed magnetic field down to 10 K and then measure levitation force. In proving the concept of the proposed design, the highest levitation forces ever reported between two superconducting bulks were measured, including a levitation force of 500 N between a 1.7 T magnetized YBCO bulk and a coaxial $MgB_{2}$ bulk tube. The biggest factor limiting the use of magnetized bulks in applications is magnetizing them in the first place. Using a pulsed magnetic field is most practical but generates excessive heat dissipation leading to a loss of flux in conventional bulk superconductors, which are 100% superconductor. Although multi-pulse techniques help maximise the trapped field, the poor thermal properties of bulk (RE)BCO are a limiting factor. New composite superconducting structures are reported which can overcome these problems by using high thermal conductivity materials, the motivation for which came from finite element modelling of the critical state coupled with heat transfer. In particular, composite structures created by cutting and stacking 12 mm wide (RE)BCO superconducting tape are shown experimentally to have exceptional field trapping ability due to superior thermal and mechanical properties compared to existing bulks. Up to 2 T was trapped in a stack of commercially available tape produced by SuperPower Inc. in the first reported pulsed magnetization of such a stack. Over 7 T was trapped between two stacks using field cooling at 4.2 K, the highest field yet trapped in such a sample.

Page generated in 0.1905 seconds